INA2128UA - Dual Precision Instrumentation Amplifier | Texas Instruments
N.º de pieza: INA2128UA ✓ ActivoINA2128UA Descripción general
An instrumentation amplifier is a differential-input amplifier optimized for measuring small signals superimposed on larger common-mode voltages. Its internal three-op-amp architecture provides matched input stages, high differential input impedance, accurate gain control, and strong common-mode rejection. This makes the INA2128 suitable for sensor interfaces where a low-level differential signal must be amplified accurately in the presence of substantial DC voltage, industrial noise, or ground-potential differences.
The INA2128 combines low offset and drift with a minimum 120 dB CMRR. Input overload protection extends to plus or minus 40 V, helping the amplifier tolerate accidental large input transients. Its supply range of 2.25 V to 18 V supports single-supply and dual-supply instrumentation systems. A single external resistor selects the gain, reducing the number of precision components needed for adjustable measurement channels.
The versatile three-op-amp design uses current-feedback input circuitry to preserve bandwidth at higher gains. According to the Texas Instruments datasheet, bandwidth remains 200 kHz at a gain of 100. This combination of precision DC behavior and usable high-gain bandwidth makes the device suitable for bridge sensors, current measurement, biomedical instrumentation, and industrial data-acquisition systems.
Typical uses include low-voltage pressure and strain-signal conditioning, thermocouple and RTD amplification, current-shunt measurement, battery-cell monitoring, and precision analog-front-end designs. The two-channel configuration is especially useful when a system must process two related sensor inputs while maintaining consistent gain-setting and supply architecture across both channels.
Choose gain resistors with suitable tolerance and temperature coefficient, and verify common-mode headroom at the lowest supply voltage. Input and reference pins require careful layout because leakage, parasitic resistance, and asymmetric copper can degrade CMRR. The gain-setting resistor should be placed close to the device, with symmetrical input routing where practical.
This product overview combines manufacturer specifications, package details, application guidance, and drop-in replacement information to support faster component selection and PCB planning. It also identifies the trade-offs involved when changing amplifier families, including gain range, bandwidth, offset performance, supply voltage, and protection requirements.
Alternativas directas para INA2128UA — mismo encapsulado, compatible pin a pin. Se excluyen las piezas de otro encapsulado que requieren retrabajo de la PCB.
Variantes de esta serie
Modelos de la misma serie compatibles directamente con INA2128UA (mismo factor de forma y huella) — difiere en Package.
INA2128U
✅ Sustitución directaConsulte el precio
Ver hoja de datos →INA2128UA-1
✅ Sustitución directa📋 Alternativa de referencia (no en el catálogo)
INA2128UA Valores máximos y características eléctricas
| Amplifier Type | Dual instrumentation amplifier |
| Number of Channels | 2 channels |
| Gain Range | 1 to 10,000 |
| Gain Setting Method | 1 external resistor |
| Bandwidth at Gain 100 | 200 kHz |
| Maximum Offset Voltage | 50 uV |
| Maximum Offset Drift | 0.5 uV/degree C |
| Maximum Input Bias Current | 5 nA |
| Minimum Common-Mode Rejection | 120 dB |
| Input Overload Protection | plus or minus 40 V |
| Supply Voltage Range | 2.25 V to 18 V |
| Internal Architecture | 3-op-amp design |
| Input Circuitry | Current-feedback |
| Encapsulado | 16-pin SOIC (DW) |
| Tipo de montaje | Surface mount |
Guía de configuración de pines de INA2128UA 16-pin soic (dw)
Configuración de pines para INA2128UA (encapsulado 16-pin soic (dw)). Este componente analógico presenta pines de entrada, salida y alimentación. Consulte la hoja de datos del fabricante para conocer las configuraciones de los pines de ajuste de offset, compensación y habilitación. Ideal para circuitos de acondicionamiento de señal y amplificadores.
No hay datos detallados de patillaje disponibles para INA2128UA.
Consulte la hoja de datos para ver la configuración completa de patillas.
Aplicaciones típicas
INA2128UA es adecuado para 6 aplicacións: Strain-Gauge Bridge Measurement, Current-Shunt Monitoring, Battery-Cell Voltage Acquisition, Precision Pressure Sensor Interface, Biomedical Sensor Signal Conditioning, Industrial Data Acquisition.
Strain-Gauge Bridge Measurement
The INA2128UA fits strain-gauge and resistive bridge front ends that produce small differential signals on a substantial common-mode voltage. Its two independently adjustable channels can process complementary bridge outputs or two related sensing elements, while the 1 to 10,000 gain range accommodates both millivolt-level and low-level volt signals. Maximum offset voltage of 50 uV and maximum drift of 0.5 uV/degree C help stabilize measurements over temperature, and 120 dB minimum CMRR suppresses common-mode excitation and coupled industrial noise. Gain is established with one resistor, allowing the design to use matched high-precision resistors while retaining a straightforward calibration structure.
Recomendado
Current-Shunt Monitoring
The INA2128UA is appropriate for bidirectional or unidirectional current measurement using a low-ohm shunt in the high-current path. Its maximum input bias current of 5 nA limits the error introduced into high-impedance sensing nodes, while plus or minus 40 V input protection improves tolerance of transient voltage during fault conditions. Two channels allow simultaneous measurement of two shunt sections or power-rail currents, and gains up to 10,000 provide useful amplification for low-value shunts. The 200 kHz bandwidth at gain 100 permits measurement of current waveforms beyond static DC without requiring a higher-speed alternative.
Recomendado
Battery-Cell Voltage Acquisition
The dual-channel INA2128UA can monitor adjacent battery cells or divided high-voltage bus sections in a battery-management system. Its 2.25 V to 18 V supply range supports low-voltage sensing rails, and the 120 dB minimum common-mode rejection helps isolate small voltage differences from the much larger potential shared by series-connected cells. Maximum offset of 50 uV and drift of 0.5 uV/degree C are particularly valuable when accurate cell balancing depends on measuring small voltage differences. The two-channel architecture reduces the number of separate amplifiers needed for redundant or differential cell measurements.
Recomendado
Precision Pressure Sensor Interface
The INA2128UA supports pressure and force sensors that generate a differential millivolt output on a common-mode baseline. The 5 nA maximum input bias current minimizes loading of high-impedance sensor outputs, and the 50 uV maximum offset reduces errors in pressure readings that depend on detecting small differential signals. Adjustable gains from 1 to 10,000 allow the same amplifier family to serve different sensor sensitivities. With 200 kHz bandwidth at gain 100, the device can also handle dynamic pressure events while retaining low DC error for static measurements.
Recomendado
Biomedical Sensor Signal Conditioning
The INA2128UA can condition low-amplitude differential signals from biomedical and diagnostic sensors where offset, drift, and common-mode rejection determine measurement quality. Its 50 uV maximum offset and 0.5 uV/degree C maximum drift limit temperature-dependent baseline errors, while 120 dB minimum CMRR helps reject mains-coupled interference and body-coupled common-mode voltage. The dual-channel configuration supports two sensors or a differential and reference channel. Plus or minus 40 V input protection is useful for robust connector interfaces, provided signal amplitude and duration remain within the device's absolute-maximum ratings.
Recomendado
Industrial Data Acquisition
The INA2128UA is well suited to industrial data-acquisition modules that combine slow precision measurements with occasional higher-bandwidth signals. Two channels support redundant sensors, bridge measurements, or gain stages feeding multiplexed converters, while the 120 dB minimum CMRR reduces errors from long cables and grounded machinery. The 200 kHz bandwidth at gain 100 provides useful signal bandwidth, and gain selection through one external resistor simplifies calibration across multiple board variants. Plus or minus 40 V input protection improves robustness at connector-exposed inputs, although protection-network design must preserve accuracy and bandwidth.
Recomendado
Resumen de productos recomendados
Datos de referencia de ingeniería para INA2128UA — comparación, orientación de diseño e información de cumplimiento.
Guía de selección
Comparación con alternativas
| Parámetro | Este producto | INA2128U | INA2128UA-1 |
|---|---|---|---|
| Brand | Texas Instruments | Texas Instruments | Texas Instruments |
| Package | SOIC-16 (DW) | SOIC-16 (DW) | SOIC-16 (DW) |
| Channel Count | 2 channels | 2 channels | 2 channels |
| Gain Range | 1 to 10,000 | 1 to 10,000 | 1 to 10,000 |
| Bandwidth at Gain 100 | 200 kHz | 200 kHz | 200 kHz |
| Supply Voltage Range | 2.25 V to 18 V | 2.25 V to 18 V | 2.25 V to 18 V |
| Input Protection | plus or minus 40 V | plus or minus 40 V | plus or minus 40 V |
Diferenciadores clave
- High accuracy for low-level differential measurements (frente a INA2128U)
- Dual-channel instrumentation amplification (frente a INA2128U)
- Strong common-mode rejection (frente a INA2128UA-1)
Notas de diseño
Keep the gain-setting resistor close to the INA2128UA gain pin, and route each input channel symmetrically. Use a common ground reference for both amplifier channels and avoid placing long, high-impedance input traces next to switching nodes. Refer to the manufacturer datasheet pin-description and application diagrams when assigning the 16-pin SOIC connections.
Do not assume the input-protection rating changes the normal operating range. The plus or minus 40 V protection rating describes tolerance of input voltage, while valid measurement operation still requires compliance with the specified common-mode and absolute-maximum limits. Also verify output swing at the selected supply voltage before choosing a gain that could saturate the amplifier.
For maximum CMRR, use equal input impedance and matched resistor networks on both sides of each differential input. Keep leakage from PCB contamination and flux residue under control because the 5 nA maximum input bias current makes high-impedance nodes sensitive to contamination. A protective resistor can limit transient current, but its value should preserve bandwidth and input impedance at the intended gain.
Place input and reference components adjacent to their corresponding pins, with the shortest practical return path to the exposed supply and ground structure. The SOIC-16 package benefits from stable ground-plane continuity beneath the device. Avoid adding test-point loops that increase parasitic capacitance on high-gain input nodes, particularly when 200 kHz bandwidth at gain 100 is a system requirement.
Información de cumplimiento
Compliance claims require confirmation for the exact INA2128UA ordering code and package. The manufacturer product and datasheet links should be reviewed during production qualification.