MC14029BF - 4-Bit Binary/Decade Up-Down Counter | onsemi
MPN: MC14029BF ✓ نشطMC14029BF نظرة عامة
A binary/decade up-down counter is a synchronous logic circuit that increments or decrements a four-bit numerical state when clocked. Binary mode represents values from 0 through 15, while decade mode supports decimal counting from 0 through 9. In the broader electronics hierarchy, the MC14029BF is a counter IC, which belongs to the logic IC and digital semiconductor categories. Its architecture combines D-type flip-flop stages with gating that permits counting in either direction, making it useful for modular arithmetic, stepper-motor position tracking, frequency division, and programmable event sequencing.
The principal feature of the MC14029BF is its bidirectional counting capability. A separate up/down control determines the counting direction, while the clock input advances the selected state on the active edge. The four parallel outputs Q0 through Q3 expose the current count for direct observation, decoding, display, or control. A cascade input allows multiple counters to form larger counting systems, and the carry and borrow outputs identify overflow or underflow conditions. A parallel load input supports initialization to a predefined count, while master reset provides a common clearing mechanism.
Because the device is implemented in complementary MOS technology, it combines low-power operation with the voltage-level behavior expected from the MC14029B logic family. The counter can be used either as a binary counter or as a decade counter, allowing the same physical circuit to serve digital clocks, industrial sequence counters, and modular arithmetic functions. Because a cascade connection introduces propagation delay between stages, designers should account for settling time when interpreting overflow signals or when several stages must transition coherently.
Typical uses include digital frequency dividers, programmable event counters, bidirectional position indicators, decade timing chains, and four-bit arithmetic sequences. In a cascaded display or timing system, one MC14029BF can count units while additional devices count tens and higher groups. The carry output can advance the next stage during an up-count, while the borrow output can decrement it during a down-count. A parallel-load path can also initialize the counter to a nonzero value, which is useful in presettable timers and sequence generators.
PCB implementation should preserve the pin assignments of the 16-pin SOIC footprint and route clock and control signals away from sensitive analog or high-speed nets. The clock input is especially important in a counter because excessive clock-edge noise can cause false increments or decrements. Keep traces short, provide a low-impedance ground reference, and avoid placing slow control inputs immediately beside the clock net when the layout permits. Follow the manufacturer’s application information for recommended decoupling and unused-input treatment.
This product page combines the manufacturer’s function description with package, pinout, sourcing, and engineering guidance. It also distinguishes the MC14029BF from related ordering codes while emphasizing that final replacement decisions require checking the complete truth table, timing limits, voltage limits, and operating-temperature requirements for the specific design.
بدائل مباشرة لـ MC14029BF — نفس الحزمة، متوافق دبوس بدبوس. تُستثنى القطع ذات الحزم المختلفة التي تتطلب تعديل PCB.
MC14029BD
✅ بديل مباشرتواصل لمعرفة السعر
عرض ورقة البيانات ←MC14029BCPG
✅ بديل مباشر📋 بديل مرجعي (غير موجود في الكتالوج)
MC14029BFELG
✅ بديل مباشر📋 بديل مرجعي (غير موجود في الكتالوج)
MC14029BF الحدود القصوى والخصائص الكهربائية
| Counter Type | Binary/Decade Up/Down Counter |
| Number of Bits | 4 bit |
| Counting Direction | Up or Down |
| Triggering | Positive edge |
| Counter Elements | 1 element |
| Logic Technology | Complementary MOS (P-channel and N-channel enhancement-mode devices) |
| Counting Modes | Binary or BCD |
| العلبة | 16-pin SOIC |
| عدد الأطراف | 16 pins |
| نوع التركيب | Surface mount |
تكوين أطراف MC14029BF
| دبوس 1 | CLK — Clock input |
| دبوس 2 | UP/DOWN — Counting-direction control input |
| دبوس 3 | Q0 — Least-significant counter output |
| دبوس 4 | Q1 — Counter output |
| دبوس 5 | Q2 — Counter output |
| دبوس 6 | Q3 — Most-significant counter output |
| دبوس 7 | LOAD — Parallel load control input |
| دبوس 8 | CARRY — Carry output |
| دبوس 9 | MR — Master reset input |
| دبوس 10 | C0 — Parallel data input C0 |
| دبوس 11 | C1 — Parallel data input C1 |
| دبوس 12 | C2 — Parallel data input C2 |
| دبوس 13 | C3 — Parallel data input C3 |
| دبوس 14 | VDD — Positive power supply |
| دبوس 15 | VSS — Ground reference |
| دبوس 16 | PL — Parallel load input |
التطبيقات النموذجية
MC14029BF مناسب لـ 6 التطبيقs: Bidirectional Position Counter, Digital Frequency Divider, Decimal Display Timing, Programmable Event Sequencer, Stepper-Motor Step Counting, Modular Arithmetic Unit.
Bidirectional Position Counter
The MC14029BF is suitable for a four-bit bidirectional position counter because it counts upward or downward according to the UP/DOWN control and exposes four parallel count outputs, Q0 through Q3. A position sensor or switch event can drive the clock after debouncing, while the counter state records movement in either direction. The carry and borrow outputs identify transitions beyond the counter’s programmed range, which can support rollover or travel-limit handling. Because the device is only four bits wide, larger travel values require cascading additional stages. Designers should also account for switch bounce and asynchronous input timing so that one physical movement produces exactly one valid count event.
موصى به
Digital Frequency Divider
The MC14029BF can divide an incoming clock into lower-frequency count events by advancing a 4-bit state on each active edge. The four Q outputs provide binary division values, allowing a downstream system to select a factor of 2, 4, 8, or 16 through decoding logic. This arrangement is useful for low-rate timing, sampling strobes, and sequencing tasks in digital control equipment. The cascade input permits larger division ratios when one stage is insufficient. Timing margin must be checked across the cascade path, especially if the next stage is expected to change immediately after the carry signal becomes valid.
موصى به
Decimal Display Timing
In decade mode, the MC14029BF can form one decimal digit of a counting display or timer because its ten-state sequence represents 0 through 9. The four output bits drive the corresponding display-decoder logic, while the carry output indicates that the next decimal position must advance. Cascading counters permits groups of three or more decimal digits, with each stage receiving the carry from the lower-order device. Parallel load provides a convenient way to preset an initial value, and master reset establishes a known zero state. Layout should keep display drivers and counter outputs logically separated to reduce simultaneous switching noise in the display circuitry.
موصى به
Programmable Event Sequencer
The MC14029BF can serve as the state-counting element in a programmable event sequencer because it combines a four-bit count with up, down, load, and reset controls. The Q outputs can be decoded into discrete steps for machinery, test equipment, or industrial controls, while parallel load allows a sequence to restart from a chosen point. The carry output can trigger an adjacent event when a step boundary is reached. For reliable operation, decoded outputs should be registered or filtered if they drive slow mechanical loads, and the clock source should remain free of ringing or switch-contact bounce.
موصى به
Stepper-Motor Step Counting
The MC14029BF can count commanded stepper-motor steps when the UP/DOWN input reflects the commanded travel direction. This creates a compact digital position record with four bits of resolution, corresponding to 16 states before wraparound or cascade is required. A directional control and the four parallel outputs can be decoded by a motion controller or supervisory logic. The clock should be generated only after each accepted step, and input filtering must prevent multiple counts from one electrical transition. For motors requiring more than 16 positions, cascade additional counters and use the carry or borrow output to extend the effective counting range.
موصى به
Modular Arithmetic Unit
The MC14029BF supports modular arithmetic because its four-bit counter can operate in binary or decade mode and can be loaded with a preset value. The UP/DOWN control permits subtraction or addition of count events, while parallel outputs make the current residue available to a controller. This function is useful in modular timing, cyclic scheduling, and compact arithmetic-state machines. Carry and borrow outputs indicate whether the operation crossed the active count boundary. The application should define how these outputs are sampled, since they are synchronous state signals and their interpretation must follow the manufacturer’s truth table and propagation-delay limits.
موصى به
ملخص المنتجات الموصى بها
بيانات مرجعية هندسية لـ MC14029BF — المقارنة وإرشادات التصميم ومعلومات الامتثال.
دليل الاختيار
المقارنة مع البدائل
| المعامل | هذا المنتج | MC14029BD | MC14029BCPG | MC14029BFELG |
|---|---|---|---|---|
| Package | SOIC-16 | SOIC-16 | SOIC-16 | SOIC-16 |
| Brand | onsemi | onsemi | onsemi | onsemi |
| Counter Type | Binary/Decade Up/Down Counter | Binary/Decade Up/Down Counter | Binary/Decade Up/Down Counter | Binary Counter, Decade |
| Number of Bits | 4 bit | 4 bit | 4 bit | 4 bit |
| Triggering | Positive edge | Positive edge | Positive edge | Positive edge |
| Counting Direction | Up/Down | Up/Down | Up/Down | Up/Down |
| Logic Technology | Complementary MOS | Complementary MOS | Complementary MOS | Complementary MOS |
| Counting Modes | Binary or BCD | Binary or BCD | Binary or BCD | Binary or BCD |
| Surface-Mount Package | 16-pin SOIC | 16-pin SOIC | 16-pin SOIC | 16-pin SOIC |
| Carrier Ordering Code | MC14029BF | MC14029BD | MC14029BCPG | MC14029BFELG |
أبرز الفروقات
- Bidirectional four-bit counting in one counter (مقابلMC14029BD)
- Parallel load, carry, borrow, and cascade functions (مقابلMC14029BFELG)
- Surface-mount implementation in a standard 16-pin footprint (مقابلMC14029BCPG)
ملاحظات التصميم
Treat CLK as a timing-critical digital input. Route it away from the UP/DOWN, LOAD, and parallel-data traces, keep the ground return continuous beneath the device, and minimize stubs on the clock net. If a mechanical switch or sensor generates the count event, add appropriate debouncing so contact bounce cannot create unintended increments. Check setup and hold requirements in the onsemi MC14029B datasheet before using a slow control signal to trigger a counter edge.
Do not treat every MC14029B ordering code as automatically interchangeable. Verify the package drawing, pin names, electrical limits, temperature grade, qualification status, and marking requirements for MC14029BD, MC14029BCPG, or MC14029BFELG before approving a substitution. Also preserve the distinction between binary and decade operation; a design that expects rollover after ten states will behave differently if the mode-control state is incorrect.
Place the device close to the logic that decodes Q0 through Q3 to minimize output trace length and ringing on high-speed count transitions. Keep the VDD and VSS connections short and follow the manufacturer’s decoupling recommendations. In cascaded counters, preserve a consistent clock distribution strategy and check propagation delay from the first stage’s carry or borrow output to the next stage’s clock input.
معلومات الامتثال
No definitive compliance declarations are stated in the manufacturer information or product listings for MC14029BF. Review the current onsemi product declaration, material compliance report, and ordering documentation before requiring a specific compliance status.