NXP Semiconductors

TJA1054T/S900/VM:5 - Fault-Tolerant CAN Transceiver | NXP

MPN: TJA1054T/S900/VM:5 ✗ انتهى عمره الإنتاجي
4.75 V to 5.25 V Vdss 14-pin SOIC Package
الحد الأدنى للطلب: 1 |

TJA1054T/S900/VM:5 نظرة عامة

NXP Semiconductors TJA1054T/S900/VM:5 is a fault-tolerant Controller Area Network transceiver with one transmitter and one receiver, a 4.75 V to 5.25 V supply range, and a 14-pin SOIC package. Designed as the physical-layer interface between a CAN protocol controller and the differential CAN bus, the device supports CAN communication at rates up to 125 kbit/s.

A CAN transceiver is the interface IC between a host controller and the physical bus wires. The hierarchy is CAN transceiver > bus transceiver > interface IC > semiconductor. In a CAN network, the controller generates and interprets CAN frames, while the transceiver converts those logic signals into the dominant and recessive levels used on the bus. The TJA1054T emphasizes dependable operation in electrically demanding vehicle environments where wiring faults, ground offsets, and bus termination issues can impair communication.

The principal features include one CAN driver and one CAN receiver, operation from 4.75 V to 5.25 V, and a specified ambient operating range of -40 °C to +150 °C. The TJA1054T supports local wake-up detection through its WAKE input and indicates a wake-up request by setting INH high, allowing an external regulator to be activated. Its fault-tolerant interface is intended to preserve communication despite common bus faults encountered in automotive wiring systems.

The TJA1054T is pin-compatible and functionally compatible with the PCA82C252T and TJA1053T according to the manufacturer product information, making those devices relevant upgrade paths for existing designs. This compatibility does not make every related TJA105x device electrically equivalent; the selected replacement must be checked against supply voltage, fault behavior, wake-up timing, bus data rate, pin functions, and package dimensions before approval.

Typical applications include low-speed CAN networks in passenger vehicles, commercial vehicles, industrial transport equipment, body controllers, door modules, instrumentation clusters, and embedded diagnostic systems. Its 125 kbit/s capability aligns with low-speed CAN networks, while its extended temperature range and fault-tolerant bus interface suit applications where environmental robustness is important.

A key PCB consideration is the SOIC-14 footprint and correct implementation of the CAN bus termination, common-mode choke, connector protection, and transceiver supply decoupling. Follow the pin-description table and recommended application circuit in the manufacturer datasheet when assigning tracks. Confirm that the PCB accommodates the specified body width and lead spacing before treating the device as a drop-in replacement.

This page combines the manufacturer interface and compatibility information with packaging details, replacement guidance, application context, and design checks for engineers evaluating the TJA1054T/S900/VM:5 in fault-tolerant CAN bus designs.

بدائل مباشرة لـ TJA1054T/S900/VM:5 — نفس الحزمة، متوافق دبوس بدبوس. تُستثنى القطع ذات الحزم المختلفة التي تتطلب تعديل PCB.

الطرازات في هذه السلسلة

طرازات من نفس السلسلة متوافقة تمامًا مع TJA1054T/S900/VM:5 (نفس عامل الشكل والبصمة) — يختلف في Package.

NXP Semiconductors
Package: 14-SO

TJA1053T/N1

✅ بديل مباشر
NXP Semiconductors
📦 14-SOIC
Half CANbus transceiver · 1 transmit / 1 receive · 4.75 V to 5.25 V · 5 V · Up to 36 V · Controller Area Network (CAN) · 14-SO · 14 pins

تواصل لمعرفة السعر

عرض ورقة البيانات ←

PCA82C252T

✅ بديل مباشر
📦 14-SOIC
The NXP manufacturer states pin compatibility and retained functions; exact fault-tolerance, timing, and auxiliary-pin differences require datasheet verification and were not quantified in the cited product-page snippet.

📋 بديل مرجعي (غير موجود في الكتالوج)

TJA1055T/C,518

✅ بديل مباشر
📦 14-SOIC
Cross-reference information describes a 14-pin SO, 5 V CAN transceiver in the same automotive class; fault-handling, wake-up, timing, and temperature differences were not quantified in the cited record.

📋 بديل مرجعي (غير موجود في الكتالوج)

TJA1054T/S900/VM:5 المواصفات

Number of Drivers 1
Number of Receivers 1
Transceiver Type CAN transceiver
Protocol CAN
Supply Voltage Range 4.75 V to 5.25 V
Maximum CAN Data Rate 125 kbit/s
نطاق درجة حرارة التشغيل -40 °C to +150 °C
العلبة 14-pin SOIC
Package Width 3.90 mm
نوع التركيب Surface mount
Packing Method Tube
Local Wake-Up Input WAKE pin
Wake-Up Indicator INH output set high
Fault-Tolerant Interface Yes
حالة RoHS Compliant

دليل تكوين أطراف TJA1054T/S900/VM:5 3.90 mm

تكوين الأطراف لـ TJA1054T/S900/VM:5 (حزمة 3.90 mm). يتم تعريف ترقيم الأطراف والوظائف ومخططات التوصيل في ورقة البيانات الفنية من الشركة المصنعة. راجعها للحصول على البصمة الدقيقة وإرشادات اللحام.

مخطط توزيع أطراف حزمة 3.90 mm لـ TJA1054T/S900/VM:5

لا تتوفر بيانات مفصلة لمخطط التوصيلات لـ TJA1054T/S900/VM:5.

راجع ورقة البيانات للحصول على تكوين الأطراف الكامل.

التطبيقات النموذجية

TJA1054T/S900/VM:5 مناسب لـ 6 التطبيقs: Low-Speed Automotive CAN Network, Commercial Vehicle Body Control, Industrial Transport CAN Module, Vehicle Door and Accessory Module, Diagnostics and Service Interface, Embedded Low-Speed CAN Sensor Network.

🚗

Low-Speed Automotive CAN Network

The TJA1054T/S900/VM:5 is suitable for a low-speed vehicle CAN network because it combines a fault-tolerant CAN interface with operation from 4.75 V to 5.25 V and a data rate of up to 125 kbit/s. Place the transceiver between the CAN controller and differential bus wiring, with bus protection and termination implemented according to the manufacturer application circuit. The -40 °C to +150 °C rating supports harsh vehicle environments, while the fault-tolerant interface is intended to improve behavior under common bus wiring errors. Because this ordering code is obsolete, it is mainly appropriate for maintenance, continuity, or previously qualified production rather than unrestricted new-platform sourcing.

🚗

Commercial Vehicle Body Control

The TJA1054T/S900/VM:5 can support CAN communication in truck, bus, and trailer body-control modules where long wiring routes increase exposure to shorts, opens, and ground-offset conditions. Its fault-tolerant CAN interface is designed for such automotive networks, while the 125 kbit/s limit matches low-speed body and comfort systems. The 14-pin SOIC footprint permits conventional surface-mount assembly, and local wake-up through WAKE and INH can coordinate recovery of an external supply. System designers should confirm that the transceiver’s protection assumptions match the vehicle’s ISO 11898 wiring environment and that the selected obsolete-device supply plan covers the product lifecycle.

🏭

Industrial Transport CAN Module

The TJA1054T/S900/VM:5 fits low-speed CAN networks in rail, agricultural, and material-handling equipment where controllers, sensors, and operator modules exchange diagnostic or control data. The 4.75 V to 5.25 V operating range integrates with regulated 5 V electronics, and the extended -40 °C to +150 °C range covers demanding equipment environments. Use the transceiver’s TXD and RXD connections to a suitable CAN controller, terminate the bus at its physical endpoints, and add transient protection for external wiring. The 125 kbit/s rate and fault-tolerant interface are useful for short, moderately noisy industrial networks where higher-speed CAN transceivers are unnecessary.

🚗

Vehicle Door and Accessory Module

The TJA1054T/S900/VM:5 can provide the physical CAN connection for door, latch, lighting, or sensor-accessory modules that participate in a low-speed vehicle network. The single-transmitter, single-receiver arrangement is appropriate for a conventional CAN node, and the wide temperature range supports electronic environments near the vehicle exterior. Connect the transceiver to the module controller, place termination where required by the network topology, and protect the external bus interface against automotive transients. Local wake-up support can reduce standby power by allowing the node to reactivate an external regulator after a bus or WAKE event.

🔧

Diagnostics and Service Interface

The TJA1054T/S900/VM:5 is appropriate for a legacy CAN diagnostic interface that bridges a service connector or tester to a 125 kbit/s vehicle network. Its fault-tolerant CAN interface helps maintain operation in environments where diagnostic cables can introduce connection faults. The transceiver requires a regulated 5 V supply within 4.75 V to 5.25 V, while the CAN controller handles frame interpretation and diagnostic requests. A robust implementation should include proper bus termination, common-mode filtering or protection where required, and separation from high-energy ignition and motor circuits.

🧩

Embedded Low-Speed CAN Sensor Network

The TJA1054T/S900/VM:5 can serve as the bus interface for a compact embedded network of industrial sensors communicating at 125 kbit/s or below. A microcontroller-based node can use the transceiver for dominant and recessive bus signaling while handling arbitration, message filtering, and diagnostics locally. The 14-pin SOIC package supports standard surface-mount assembly, and the 5 V operating range simplifies integration with sensors and controllers that already use regulated 5 V. Validate cable length, topology, termination, common-mode margin, and protection against conducted noise because transceiver specifications alone do not guarantee network-level performance.

What is the TJA1054T/S900/VM:5?
The TJA1054T/S900/VM:5 is an NXP Semiconductors fault-tolerant CAN transceiver with one transmitter, one receiver, a 4.75 V to 5.25 V supply range, and a 14-pin SOIC package. According to the NXP manufacturer datasheet, it is intended primarily for low-speed CAN systems operating up to 125 kbit/s. The device connects a CAN protocol controller to the physical differential bus and includes local wake-up support through the WAKE and INH pins.
What is the maximum CAN data rate of TJA1054T/S900/VM:5?
The TJA1054T/S900/VM:5 supports CAN communication up to 125 kbit/s. The NXP manufacturer datasheet identifies the TJA1054 as a low-speed CAN physical-layer interface, so it is intended for networks operating at 125 kbit/s or below. This rating applies to the transceiver and bus implementation as a whole, so controller timing, cable length, termination, and fault-protection components must also satisfy the system requirements.
What supply voltage does TJA1054T/S900/VM:5 require?
The TJA1054T/S900/VM:5 operates from a 4.75 V to 5.25 V supply. According to the NXP manufacturer datasheet, this range supports regulated 5 V CAN transceiver implementations. The PCB should provide local decoupling close to the device supply pins, and the selected regulator should remain within its tolerance across temperature and load conditions. Connecting a supply outside the stated interval can impair transceiver operation and should be prevented by design verification.
Where can I download the TJA1054T datasheet PDF?
The official TJA1054 datasheet PDF is available from NXP at https://www.nxp.com/docs/en/data-sheet/TJA1054.pdf. Use the manufacturer document for the pin-description table, electrical characteristics, timing diagrams, fault behavior, and recommended application circuit. The TJA1054T/S900/VM:5 ordering code identifies the tube-packed version of the TJA1054T, so verify that the document revision covers the selected package and temperature grade.
Where is the pinout for TJA1054T/S900/VM:5?
The TJA1054T/S900/VM:5 pinout is shown in the pin-description table of the NXP TJA1054 manufacturer datasheet. The device uses a 14-pin SOIC package, designated 14-SO, with a 3.90 mm body width. Use the manufacturer diagram when assigning CANH, CANL, TXD, RXD, VCC, GND, WAKE, INH, and related signals. Do not infer pin functions from similarly named TJA105x devices because auxiliary-pin assignments can vary.
Is TJA1054T/S900/VM:5 suitable for automotive applications?
The TJA1054T/S900/VM:5 is suitable for many automotive CAN applications because it provides a fault-tolerant interface, 125 kbit/s CAN operation, and an operating temperature range of -40 °C to +150 °C. According to the NXP manufacturer information, its bus interface is intended to withstand common automotive wiring conditions. For a released safety- or automotive-qualified product, confirm the exact AEC-Q100 qualification status and production requirements before release.
What can replace TJA1054T/S900/VM:5?
The NXP TJA1054T/S900/VM:5 can be replaced by the TJA1053T or PCA82C252T where the manufacturer’s stated compatibility applies. According to the NXP product page, the TJA1054T is pin-compatible with the PCA82C252T and TJA1053T and retains their functions. Because the specified VM:5 order code is obsolete, engineers should also check package dimensions, temperature grade, supply requirements, wake-up behavior, and lifecycle status before approving a substitution.
Is TJA1054T the same as PCA82C252T?
The TJA1054T is not identical to the PCA82C252T, but the NXP manufacturer states that it is pin-compatible and can replace the PCA82C252T while retaining all functions. The TJA1054T adds the fault-tolerant CAN interface characteristics of the TJA1054 family. For a production replacement, verify the complete pin table, electrical limits, bus timing, sleep and wake behavior, and any different qualification requirements rather than relying only on package compatibility.
What is the best drop-in replacement for TJA1054T/S900/VM:5?
The strongest documented replacement path is the NXP TJA1053T or PCA82C252T because the manufacturer identifies the TJA1054T as pin-compatible with both. The TJA1054T/S900/VM:5 itself is listed as obsolete, making lifecycle availability an important selection criterion. Before choosing a replacement, compare the 4.75 V to 5.25 V supply range, 125 kbit/s bus capability, operating temperature, wake-up functions, fault behavior, and 14-pin SOIC footprint.
When should I choose TJA1054T/S900/VM:5 over TJA1053T?
Choose the TJA1054T/S900/VM:5 when the design specifically benefits from its fault-tolerant CAN interface and broad -40 °C to +150 °C operating range. Choose the TJA1053T when its lifecycle availability and exact behavior better match the target design and no TJA1054-specific fault-tolerance requirement exists. The manufacturer states that the TJA1054T can retain the TJA1053T functions, but final selection still requires a complete electrical and timing comparison.
What is the difference between TJA1054T and TJA1053T?
The principal documented difference is the TJA1054T’s fault-tolerant CAN transceiver implementation and its stated compatibility with the TJA1053T’s functions and pin arrangement. Both are associated with low-speed CAN interfaces and 5 V operation, but the TJA1054 also provides local wake-up detection through WAKE and indication through INH. The TJA1054T/S900/VM:5 is obsolete, so lifecycle and qualification constraints may outweigh the functional benefits in a new design.
Is TJA1055T/C,518 a replacement for TJA1054T/S900/VM:5?
The TJA1055T/C,518 should be treated as a conditional replacement candidate rather than an automatic drop-in substitute. Cross-reference information identifies it as a 14-pin SO CAN transceiver in the 5 V automotive class, but that description does not by itself establish equivalent wake-up behavior, fault handling, timing, or pin mapping. Compare the complete NXP datasheets and pin tables, and verify supply, data rate, temperature, package dimensions, and lifecycle status before schematic approval.
Where can I buy TJA1054T/S900/VM:5?
Use the Request a Quote form on this page to request the TJA1054T/S900/VM:5, current inventory, and lot traceability. The part is listed as obsolete, so availability may depend on remaining factory inventory, authorized-channel stock, or qualified aftermarket inventory. State the required tube quantity, date-code preference, inspection level, and target quantity on the request so the supplier can match the exact ordering code and delivery conditions.
What is the price of TJA1054T/S900/VM:5?
The current commercial price for TJA1054T/S900/VM:5 should be requested through the Request a Quote form on this page. Because the device is obsolete, pricing can depend on remaining lot size, date code, traceability, and inspection requirements. The structured pricing information on this page is intended to update independently; request a formal quotation for the exact MPN and quantity rather than relying on a historical unit-price reference.
What is the lead time and stock status for TJA1054T/S900/VM:5?
Request the current stock position and lead time for TJA1054T/S900/VM:5 through the Request a Quote form on this page. The manufacturer has discontinued this ordering code, so standard lead times associated with active production parts may not apply. A supplier must confirm whether any inventory is factory-new, date-code controlled, or traceable, and should also identify the shipment quantity and any inspection or compliance documentation that can be supplied.
What are the key specifications of TJA1054T/S900/VM:5 that engineers should know?
The key TJA1054T/S900/VM:5 specifications are one CAN transmitter, one CAN receiver, a 4.75 V to 5.25 V supply, operation up to 125 kbit/s, and a -40 °C to +150 °C ambient range. The NXP manufacturer datasheet also describes fault-tolerant CAN operation, local wake-up through the WAKE pin, and INH wake-up indication. The physical package is 14-pin SOIC, supplied in a tube for the specified ordering code.

بيانات مرجعية هندسية لـ TJA1054T/S900/VM:5 — المقارنة وإرشادات التصميم ومعلومات الامتثال.

دليل الاختيار

Choose the TJA1054T/S900/VM:5 for maintaining an existing low-speed CAN design that specifically relies on its fault-tolerant bus interface, 125 kbit/s operation, extended temperature range, and WAKE/INH behavior. For an existing board using TJA1053T or PCA82C252T, those parts are the best-supported replacement paths because the NXP manufacturer states pin compatibility and retained functions; verify the complete electrical and timing tables before approval. Consider TJA1055T/C,518 when lifecycle availability is favorable and its datasheet confirms that its fault handling, auxiliary pins, and timing satisfy the system. Do not choose a replacement by package number alone. Check the 4.75 V to 5.25 V supply, 125 kbit/s limit, operating temperature, wake-up logic, CANH/CANL behavior, test functions, and automotive qualification. Because the target ordering code is obsolete, sourcing continuity, traceability, and long-term maintenance requirements may make an active-family redesign more practical than a direct substitution.

المقارنة مع البدائل

المعامل هذا المنتج TJA1053T PCA82C252T TJA1055T/C,518
Brand NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors
Package 14-SOIC 14-SOIC 14-SOIC 14-SOIC
Protocol CAN CAN CAN CAN

أبرز الفروقات

  • Documented compatibility with two established CAN interface devices (مقابلTJA1053T)
  • Fault-tolerant CAN physical-layer implementation (مقابلPCA82C252T)
  • Local system wake-up through dedicated WAKE and INH functions (مقابلTJA1055T/C,518)

ملاحظات التصميم

Assign the PCB footprint from the 14-SOIC mechanical drawing rather than relying only on the generic package name. Keep the CANH and CANL routes short, symmetrical where practical, and away from high-current switching nodes. Place the transceiver close to the bus connector or protection network so transient-current paths do not cross sensitive logic traces. Confirm pin 1 orientation, body width, lead pitch, and solder-mask clearance against the latest NXP package drawing before releasing artwork.

Provide a regulated 5 V supply that remains within the TJA1054T’s 4.75 V to 5.25 V operating range under temperature, load, and supply-line variation. Place the required local bypass capacitor at the transceiver supply pins with a short return path to ground. Use the manufacturer recommended values and layout because excessive trace resistance or inductance can reduce local noise margin. The WAKE and INH functions must also be evaluated against the external regulator’s enable thresholds and leakage behavior.

Treat CANH and CANL as a differential pair and route them together without unrelated branch stubs. Install the specified termination only at the intended physical endpoints of the bus, and evaluate common-mode choke placement according to the manufacturer application guidance. Keep protection-device capacitance low enough to preserve bus timing at 125 kbit/s. Separate the CAN pair from antenna, relay, motor, and power-converter wiring to reduce fault-induced and radiated coupling.

Do not substitute a TJA105x device solely because it is labeled as a 14-pin CAN transceiver. Compare TXD polarity, RXD behavior, standby and wake-up logic, INH implementation, bus fault behavior, loopback and test functions, timing, supply range, temperature grade, and package dimensions. The manufacturer explicitly identifies compatibility with TJA1053T and PCA82C252T, but every selected alternate still requires a schematic and PCB review against the complete pin table.

معلومات الامتثال

RoHS
Compliant
REACH
Unknown
AEC-Q100
Unknown
خالٍ من الرصاص
Unknown
خالٍ من الهالوجين
Unknown
المعادن المتنازع عليها
Unknown

RoHS compliance is identified by an obsolete-stock listing. REACH, AEC-Q100, lead-free, halogen-free, and conflict-minerals status require confirmation for the exact ordering code and remaining manufacturer lot.

تم التحقق من البيانات في: 2026-11-22 — تم التحقق من البيانات وتنسيقها بواسطة فريق هندسة المكونات في XAIPART

عمليات بحث ذات صلة

tja1054t datasheet tja1054t pdf nxp tja1054t TJA1054T/S900/VM:5 datasheet TJA1054T/S900/VM:5 pinout TJA1054T/S900/VM:5 equivalent TJA1054T/S900/VM:5 replacement TJA1054T/S900/VM:5 price TJA1054T/S900/VM:5 stock TJA1054T 14-SOIC CAN transceiver TJA1054T low-speed CAN application TJA1054T vs TJA1053T

المكونات والمصطلحات ذات الصلة

NXP Semiconductors TJA1054T/S900/VM:5 TJA1054T TJA1053T PCA82C252T TJA1055T/C,518 CAN transceiver Controller Area Network physical-layer interface interface IC semiconductor fault-tolerant CAN 125 kbit/s CAN 5 V CAN transceiver 4.75 V to 5.25 V supply 14-SOIC SOIC package family surface-mount technology WAKE pin INH output automotive CAN network industrial CAN RoHS REACH AEC-Q100
عرض سعر سريع RFQ
املأ التفاصيل الكاملة — سيرد فريق المبيعات لدينا خلال 24 ساعة
رقم القطعة الشركة المصنعة الحزمة QTY السعر المستهدف الإجمالي
✓
تم إرسال عرض السعر!

سنرد على بريدك الإلكتروني خلال 24 ساعة

1
تم إرسال طلب عرض السعر
2
تم استلام عرض السعر
3
تم تقديم الطلب
4
الدفع
5
تم الشحن
6
تم التسليم
عرض تفاصيل طلب عرض السعر