TJA1054T/S900/VM:5 - Fault-Tolerant CAN Transceiver | NXP
MPN: TJA1054T/S900/VM:5 ✗ پایان تولیدTJA1054T/S900/VM:5 نمای کلی
A CAN transceiver is the interface IC between a host controller and the physical bus wires. The hierarchy is CAN transceiver > bus transceiver > interface IC > semiconductor. In a CAN network, the controller generates and interprets CAN frames, while the transceiver converts those logic signals into the dominant and recessive levels used on the bus. The TJA1054T emphasizes dependable operation in electrically demanding vehicle environments where wiring faults, ground offsets, and bus termination issues can impair communication.
The principal features include one CAN driver and one CAN receiver, operation from 4.75 V to 5.25 V, and a specified ambient operating range of -40 °C to +150 °C. The TJA1054T supports local wake-up detection through its WAKE input and indicates a wake-up request by setting INH high, allowing an external regulator to be activated. Its fault-tolerant interface is intended to preserve communication despite common bus faults encountered in automotive wiring systems.
The TJA1054T is pin-compatible and functionally compatible with the PCA82C252T and TJA1053T according to the manufacturer product information, making those devices relevant upgrade paths for existing designs. This compatibility does not make every related TJA105x device electrically equivalent; the selected replacement must be checked against supply voltage, fault behavior, wake-up timing, bus data rate, pin functions, and package dimensions before approval.
Typical applications include low-speed CAN networks in passenger vehicles, commercial vehicles, industrial transport equipment, body controllers, door modules, instrumentation clusters, and embedded diagnostic systems. Its 125 kbit/s capability aligns with low-speed CAN networks, while its extended temperature range and fault-tolerant bus interface suit applications where environmental robustness is important.
A key PCB consideration is the SOIC-14 footprint and correct implementation of the CAN bus termination, common-mode choke, connector protection, and transceiver supply decoupling. Follow the pin-description table and recommended application circuit in the manufacturer datasheet when assigning tracks. Confirm that the PCB accommodates the specified body width and lead spacing before treating the device as a drop-in replacement.
This page combines the manufacturer interface and compatibility information with packaging details, replacement guidance, application context, and design checks for engineers evaluating the TJA1054T/S900/VM:5 in fault-tolerant CAN bus designs.
جایگزینهای drop-in برای TJA1054T/S900/VM:5 — همان پکیج، سازگار پینبهپین. قطعات با پکیج متفاوت که نیاز به تغییر PCB دارند مستثنی هستند.
گونهها در این سری
مدلهای همسری که جایگزین مستقیم هستند برای TJA1054T/S900/VM:5 (همان فرمفاکتور و فوتپرینت) — متفاوت در Package.
TJA1053T/N1
✅ جایگزین مستقیمبرای قیمت تماس بگیرید
مشاهده دیتاشیت ←PCA82C252T
✅ جایگزین مستقیم📋 جایگزین مرجع (خارج از کاتالوگ)
TJA1055T/C,518
✅ جایگزین مستقیم📋 جایگزین مرجع (خارج از کاتالوگ)
TJA1054T/S900/VM:5 مشخصات
| Number of Drivers | 1 |
| Number of Receivers | 1 |
| Transceiver Type | CAN transceiver |
| Protocol | CAN |
| Supply Voltage Range | 4.75 V to 5.25 V |
| Maximum CAN Data Rate | 125 kbit/s |
| محدوده دمای کاری | -40 °C to +150 °C |
| بستهبندی | 14-pin SOIC |
| Package Width | 3.90 mm |
| نوع نصب | Surface mount |
| Packing Method | Tube |
| Local Wake-Up Input | WAKE pin |
| Wake-Up Indicator | INH output set high |
| Fault-Tolerant Interface | Yes |
| وضعیت RoHS | Compliant |
راهنمای پیکربندی پین TJA1054T/S900/VM:5 3.90 mm
پیکربندی پین برای TJA1054T/S900/VM:5 (پکیج 3.90 mm). شمارهگذاری پایهها، عملکردها و نمودارهای اتصال در دیتاشیت سازنده تعریف شده است. برای footprint دقیق و دستورالعملهای لحیمکاری به آن مراجعه کنید.
داده پینآوت تفصیلی موجود نیست برای TJA1054T/S900/VM:5.
به دیتاشیت برای پیکربندی کامل پینها.
کاربردهای معمول
TJA1054T/S900/VM:5 مناسب است برای 6 کاربردs: Low-Speed Automotive CAN Network, Commercial Vehicle Body Control, Industrial Transport CAN Module, Vehicle Door and Accessory Module, Diagnostics and Service Interface, Embedded Low-Speed CAN Sensor Network.
Low-Speed Automotive CAN Network
The TJA1054T/S900/VM:5 is suitable for a low-speed vehicle CAN network because it combines a fault-tolerant CAN interface with operation from 4.75 V to 5.25 V and a data rate of up to 125 kbit/s. Place the transceiver between the CAN controller and differential bus wiring, with bus protection and termination implemented according to the manufacturer application circuit. The -40 °C to +150 °C rating supports harsh vehicle environments, while the fault-tolerant interface is intended to improve behavior under common bus wiring errors. Because this ordering code is obsolete, it is mainly appropriate for maintenance, continuity, or previously qualified production rather than unrestricted new-platform sourcing.
پیشنهادی
Commercial Vehicle Body Control
The TJA1054T/S900/VM:5 can support CAN communication in truck, bus, and trailer body-control modules where long wiring routes increase exposure to shorts, opens, and ground-offset conditions. Its fault-tolerant CAN interface is designed for such automotive networks, while the 125 kbit/s limit matches low-speed body and comfort systems. The 14-pin SOIC footprint permits conventional surface-mount assembly, and local wake-up through WAKE and INH can coordinate recovery of an external supply. System designers should confirm that the transceiver’s protection assumptions match the vehicle’s ISO 11898 wiring environment and that the selected obsolete-device supply plan covers the product lifecycle.
پیشنهادی
Industrial Transport CAN Module
The TJA1054T/S900/VM:5 fits low-speed CAN networks in rail, agricultural, and material-handling equipment where controllers, sensors, and operator modules exchange diagnostic or control data. The 4.75 V to 5.25 V operating range integrates with regulated 5 V electronics, and the extended -40 °C to +150 °C range covers demanding equipment environments. Use the transceiver’s TXD and RXD connections to a suitable CAN controller, terminate the bus at its physical endpoints, and add transient protection for external wiring. The 125 kbit/s rate and fault-tolerant interface are useful for short, moderately noisy industrial networks where higher-speed CAN transceivers are unnecessary.
پیشنهادی
Vehicle Door and Accessory Module
The TJA1054T/S900/VM:5 can provide the physical CAN connection for door, latch, lighting, or sensor-accessory modules that participate in a low-speed vehicle network. The single-transmitter, single-receiver arrangement is appropriate for a conventional CAN node, and the wide temperature range supports electronic environments near the vehicle exterior. Connect the transceiver to the module controller, place termination where required by the network topology, and protect the external bus interface against automotive transients. Local wake-up support can reduce standby power by allowing the node to reactivate an external regulator after a bus or WAKE event.
پیشنهادی
Diagnostics and Service Interface
The TJA1054T/S900/VM:5 is appropriate for a legacy CAN diagnostic interface that bridges a service connector or tester to a 125 kbit/s vehicle network. Its fault-tolerant CAN interface helps maintain operation in environments where diagnostic cables can introduce connection faults. The transceiver requires a regulated 5 V supply within 4.75 V to 5.25 V, while the CAN controller handles frame interpretation and diagnostic requests. A robust implementation should include proper bus termination, common-mode filtering or protection where required, and separation from high-energy ignition and motor circuits.
پیشنهادی
Embedded Low-Speed CAN Sensor Network
The TJA1054T/S900/VM:5 can serve as the bus interface for a compact embedded network of industrial sensors communicating at 125 kbit/s or below. A microcontroller-based node can use the transceiver for dominant and recessive bus signaling while handling arbitration, message filtering, and diagnostics locally. The 14-pin SOIC package supports standard surface-mount assembly, and the 5 V operating range simplifies integration with sensors and controllers that already use regulated 5 V. Validate cable length, topology, termination, common-mode margin, and protection against conducted noise because transceiver specifications alone do not guarantee network-level performance.
پیشنهادی
خلاصه محصولات پیشنهادی
دادههای مرجع مهندسی برای TJA1054T/S900/VM:5 — مقایسه، راهنمای طراحی و اطلاعات انطباق.
راهنمای انتخاب
مقایسه با جایگزینها
| پارامتر | این محصول | TJA1053T | PCA82C252T | TJA1055T/C,518 |
|---|---|---|---|---|
| Brand | NXP Semiconductors | NXP Semiconductors | NXP Semiconductors | NXP Semiconductors |
| Package | 14-SOIC | 14-SOIC | 14-SOIC | 14-SOIC |
| Protocol | CAN | CAN | CAN | CAN |
تفاوتهای کلیدی
- Documented compatibility with two established CAN interface devices (در مقابلTJA1053T)
- Fault-tolerant CAN physical-layer implementation (در مقابلPCA82C252T)
- Local system wake-up through dedicated WAKE and INH functions (در مقابلTJA1055T/C,518)
یادداشتهای طراحی
Assign the PCB footprint from the 14-SOIC mechanical drawing rather than relying only on the generic package name. Keep the CANH and CANL routes short, symmetrical where practical, and away from high-current switching nodes. Place the transceiver close to the bus connector or protection network so transient-current paths do not cross sensitive logic traces. Confirm pin 1 orientation, body width, lead pitch, and solder-mask clearance against the latest NXP package drawing before releasing artwork.
Provide a regulated 5 V supply that remains within the TJA1054T’s 4.75 V to 5.25 V operating range under temperature, load, and supply-line variation. Place the required local bypass capacitor at the transceiver supply pins with a short return path to ground. Use the manufacturer recommended values and layout because excessive trace resistance or inductance can reduce local noise margin. The WAKE and INH functions must also be evaluated against the external regulator’s enable thresholds and leakage behavior.
Treat CANH and CANL as a differential pair and route them together without unrelated branch stubs. Install the specified termination only at the intended physical endpoints of the bus, and evaluate common-mode choke placement according to the manufacturer application guidance. Keep protection-device capacitance low enough to preserve bus timing at 125 kbit/s. Separate the CAN pair from antenna, relay, motor, and power-converter wiring to reduce fault-induced and radiated coupling.
Do not substitute a TJA105x device solely because it is labeled as a 14-pin CAN transceiver. Compare TXD polarity, RXD behavior, standby and wake-up logic, INH implementation, bus fault behavior, loopback and test functions, timing, supply range, temperature grade, and package dimensions. The manufacturer explicitly identifies compatibility with TJA1053T and PCA82C252T, but every selected alternate still requires a schematic and PCB review against the complete pin table.
اطلاعات انطباق
RoHS compliance is identified by an obsolete-stock listing. REACH, AEC-Q100, lead-free, halogen-free, and conflict-minerals status require confirmation for the exact ordering code and remaining manufacturer lot.