TJA1054T/S900/VM:5 - Fault-Tolerant CAN Transceiver | NXP
MPN: TJA1054T/S900/VM:5 ✗ Tapus ng BuhayTJA1054T/S900/VM:5 Ulas
A CAN transceiver is the interface IC between a host controller and the physical bus wires. The hierarchy is CAN transceiver > bus transceiver > interface IC > semiconductor. In a CAN network, the controller generates and interprets CAN frames, while the transceiver converts those logic signals into the dominant and recessive levels used on the bus. The TJA1054T emphasizes dependable operation in electrically demanding vehicle environments where wiring faults, ground offsets, and bus termination issues can impair communication.
The principal features include one CAN driver and one CAN receiver, operation from 4.75 V to 5.25 V, and a specified ambient operating range of -40 °C to +150 °C. The TJA1054T supports local wake-up detection through its WAKE input and indicates a wake-up request by setting INH high, allowing an external regulator to be activated. Its fault-tolerant interface is intended to preserve communication despite common bus faults encountered in automotive wiring systems.
The TJA1054T is pin-compatible and functionally compatible with the PCA82C252T and TJA1053T according to the manufacturer product information, making those devices relevant upgrade paths for existing designs. This compatibility does not make every related TJA105x device electrically equivalent; the selected replacement must be checked against supply voltage, fault behavior, wake-up timing, bus data rate, pin functions, and package dimensions before approval.
Typical applications include low-speed CAN networks in passenger vehicles, commercial vehicles, industrial transport equipment, body controllers, door modules, instrumentation clusters, and embedded diagnostic systems. Its 125 kbit/s capability aligns with low-speed CAN networks, while its extended temperature range and fault-tolerant bus interface suit applications where environmental robustness is important.
A key PCB consideration is the SOIC-14 footprint and correct implementation of the CAN bus termination, common-mode choke, connector protection, and transceiver supply decoupling. Follow the pin-description table and recommended application circuit in the manufacturer datasheet when assigning tracks. Confirm that the PCB accommodates the specified body width and lead spacing before treating the device as a drop-in replacement.
This page combines the manufacturer interface and compatibility information with packaging details, replacement guidance, application context, and design checks for engineers evaluating the TJA1054T/S900/VM:5 in fault-tolerant CAN bus designs.
Mga alternatibo na pwedeng ilagay na TJA1054T/S900/VM:5 — parehas na package, pin-to-pin na katugmang. Hindi kasama ang mga bahagi ng iba't-ibang package na nangangailangan ng pagpapaayos ng PCB.
Variante sa Seri na ito
Katulad na modelo sa serye na katugma sa pagpasok TJA1054T/S900/VM:5 (parehas na form factor at footprint) — pagkakaiba sa Package.
TJA1053T/N1
✅ Drop-InMagkontak para sa presyo
Tingnan ang Datasheet →PCA82C252T
✅ Drop-In📋 Alternatibo na Reference (hindi sa katalogo)
TJA1055T/C,518
✅ Drop-In📋 Alternatibo na Reference (hindi sa katalogo)
TJA1054T/S900/VM:5 Mga Spesipikasyon
| Number of Drivers | 1 |
| Number of Receivers | 1 |
| Transceiver Type | CAN transceiver |
| Protocol | CAN |
| Supply Voltage Range | 4.75 V to 5.25 V |
| Maximum CAN Data Rate | 125 kbit/s |
| Hanay ng Temperature na Operasyon | -40 °C to +150 °C |
| Packhaging | 14-pin SOIC |
| Package Width | 3.90 mm |
| Uri ng Pagpapasok | Surface mount |
| Packing Method | Tube |
| Local Wake-Up Input | WAKE pin |
| Wake-Up Indicator | INH output set high |
| Fault-Tolerant Interface | Yes |
| Tindminan RoHS | Compliant |
Gabay sa Pin Configuration ng TJA1054T/S900/VM:5 3.90 mm
Pin configuration para sa TJA1054T/S900/VM:5 (3.90 mm package). Ang pagnunumero ng pin, mga function, at connection diagram ay tinukoy sa datasheet ng manufacturer. Sumangguni dito para sa eksaktong footprint at mga alituntunin sa soldering.
Wala ng detalyadong pinout data na magagamit para sa TJA1054T/S900/VM:5.
Sumangguni sa datasheet para sa buong pin configuration.
Tipikal na mga Gamit
TJA1054T/S900/VM:5 ay nararapat para sa 6 aplikasyons: Low-Speed Automotive CAN Network, Commercial Vehicle Body Control, Industrial Transport CAN Module, Vehicle Door and Accessory Module, Diagnostics and Service Interface, Embedded Low-Speed CAN Sensor Network.
Low-Speed Automotive CAN Network
The TJA1054T/S900/VM:5 is suitable for a low-speed vehicle CAN network because it combines a fault-tolerant CAN interface with operation from 4.75 V to 5.25 V and a data rate of up to 125 kbit/s. Place the transceiver between the CAN controller and differential bus wiring, with bus protection and termination implemented according to the manufacturer application circuit. The -40 °C to +150 °C rating supports harsh vehicle environments, while the fault-tolerant interface is intended to improve behavior under common bus wiring errors. Because this ordering code is obsolete, it is mainly appropriate for maintenance, continuity, or previously qualified production rather than unrestricted new-platform sourcing.
Inirekomenda
Commercial Vehicle Body Control
The TJA1054T/S900/VM:5 can support CAN communication in truck, bus, and trailer body-control modules where long wiring routes increase exposure to shorts, opens, and ground-offset conditions. Its fault-tolerant CAN interface is designed for such automotive networks, while the 125 kbit/s limit matches low-speed body and comfort systems. The 14-pin SOIC footprint permits conventional surface-mount assembly, and local wake-up through WAKE and INH can coordinate recovery of an external supply. System designers should confirm that the transceiver’s protection assumptions match the vehicle’s ISO 11898 wiring environment and that the selected obsolete-device supply plan covers the product lifecycle.
Inirekomenda
Industrial Transport CAN Module
The TJA1054T/S900/VM:5 fits low-speed CAN networks in rail, agricultural, and material-handling equipment where controllers, sensors, and operator modules exchange diagnostic or control data. The 4.75 V to 5.25 V operating range integrates with regulated 5 V electronics, and the extended -40 °C to +150 °C range covers demanding equipment environments. Use the transceiver’s TXD and RXD connections to a suitable CAN controller, terminate the bus at its physical endpoints, and add transient protection for external wiring. The 125 kbit/s rate and fault-tolerant interface are useful for short, moderately noisy industrial networks where higher-speed CAN transceivers are unnecessary.
Inirekomenda
Vehicle Door and Accessory Module
The TJA1054T/S900/VM:5 can provide the physical CAN connection for door, latch, lighting, or sensor-accessory modules that participate in a low-speed vehicle network. The single-transmitter, single-receiver arrangement is appropriate for a conventional CAN node, and the wide temperature range supports electronic environments near the vehicle exterior. Connect the transceiver to the module controller, place termination where required by the network topology, and protect the external bus interface against automotive transients. Local wake-up support can reduce standby power by allowing the node to reactivate an external regulator after a bus or WAKE event.
Inirekomenda
Diagnostics and Service Interface
The TJA1054T/S900/VM:5 is appropriate for a legacy CAN diagnostic interface that bridges a service connector or tester to a 125 kbit/s vehicle network. Its fault-tolerant CAN interface helps maintain operation in environments where diagnostic cables can introduce connection faults. The transceiver requires a regulated 5 V supply within 4.75 V to 5.25 V, while the CAN controller handles frame interpretation and diagnostic requests. A robust implementation should include proper bus termination, common-mode filtering or protection where required, and separation from high-energy ignition and motor circuits.
Inirekomenda
Embedded Low-Speed CAN Sensor Network
The TJA1054T/S900/VM:5 can serve as the bus interface for a compact embedded network of industrial sensors communicating at 125 kbit/s or below. A microcontroller-based node can use the transceiver for dominant and recessive bus signaling while handling arbitration, message filtering, and diagnostics locally. The 14-pin SOIC package supports standard surface-mount assembly, and the 5 V operating range simplifies integration with sensors and controllers that already use regulated 5 V. Validate cable length, topology, termination, common-mode margin, and protection against conducted noise because transceiver specifications alone do not guarantee network-level performance.
Inirekomenda
Buod ng mga Inirekomendang Produkto
Impormasyon ng Talumpati sa Engineering for TJA1054T/S900/VM:5 — ikabit, gabay sa disenyo, at impormasyon ng pagsunod sa kautusan.
Paunawang Hanapin
Ikabit sa Mga Alternatibo
| Parametro | Ito ang Producto | TJA1053T | PCA82C252T | TJA1055T/C,518 |
|---|---|---|---|---|
| Brand | NXP Semiconductors | NXP Semiconductors | NXP Semiconductors | NXP Semiconductors |
| Package | 14-SOIC | 14-SOIC | 14-SOIC | 14-SOIC |
| Protocol | CAN | CAN | CAN | CAN |
Pangunahing mga Pagkakaiba
- Documented compatibility with two established CAN interface devices (kumpara saTJA1053T)
- Fault-tolerant CAN physical-layer implementation (kumpara saPCA82C252T)
- Local system wake-up through dedicated WAKE and INH functions (kumpara saTJA1055T/C,518)
Talaan ng Disenyo
Assign the PCB footprint from the 14-SOIC mechanical drawing rather than relying only on the generic package name. Keep the CANH and CANL routes short, symmetrical where practical, and away from high-current switching nodes. Place the transceiver close to the bus connector or protection network so transient-current paths do not cross sensitive logic traces. Confirm pin 1 orientation, body width, lead pitch, and solder-mask clearance against the latest NXP package drawing before releasing artwork.
Provide a regulated 5 V supply that remains within the TJA1054T’s 4.75 V to 5.25 V operating range under temperature, load, and supply-line variation. Place the required local bypass capacitor at the transceiver supply pins with a short return path to ground. Use the manufacturer recommended values and layout because excessive trace resistance or inductance can reduce local noise margin. The WAKE and INH functions must also be evaluated against the external regulator’s enable thresholds and leakage behavior.
Treat CANH and CANL as a differential pair and route them together without unrelated branch stubs. Install the specified termination only at the intended physical endpoints of the bus, and evaluate common-mode choke placement according to the manufacturer application guidance. Keep protection-device capacitance low enough to preserve bus timing at 125 kbit/s. Separate the CAN pair from antenna, relay, motor, and power-converter wiring to reduce fault-induced and radiated coupling.
Do not substitute a TJA105x device solely because it is labeled as a 14-pin CAN transceiver. Compare TXD polarity, RXD behavior, standby and wake-up logic, INH implementation, bus fault behavior, loopback and test functions, timing, supply range, temperature grade, and package dimensions. The manufacturer explicitly identifies compatibility with TJA1053T and PCA82C252T, but every selected alternate still requires a schematic and PCB review against the complete pin table.
Impormasyon ng Pagsunod sa Kautusan
RoHS compliance is identified by an obsolete-stock listing. REACH, AEC-Q100, lead-free, halogen-free, and conflict-minerals status require confirmation for the exact ordering code and remaining manufacturer lot.