INA2128U/1K - Dual Instrumentation Amplifier | Texas Instruments
MPN: INA2128U/1K ✓ সক্রিয়INA2128U/1K সারাংশ
An instrumentation amplifier is a specialized amplifier-and-op-amp category designed to amplify small differential signals while rejecting common-mode interference. Its internal three-op-amp architecture provides high input impedance, symmetrical differential inputs, accurate gain control, and straightforward scaling of sensor outputs. Within the broader semiconductor hierarchy, the INA2128 belongs to the precision analog amplifier class and is used as a front-end signal-conditioning component between sensors or measurement networks and data converters.
Key features include two independent amplifiers on one die, a gain range of 1 to 10,000, and current-feedback input circuitry that maintains useful bandwidth at higher gain. The 200 kHz bandwidth quoted at gain 100 makes the device suitable for sensors whose signals must be measured with limited filtering. Its dual-channel arrangement also reduces board area when two independent measurements are required, such as sensing a bridge output and a reference voltage.
The three-op-amp architecture uses external gain-setting resistors and internal precision circuitry. Because the signal path is differential, common-mode voltage and gain errors can be rejected more effectively than with a single ordinary op-amp stage. Designers must nevertheless consider resistor tolerance, input common-mode range, output swing, supply headroom, and stability when adding input and output filtering capacitors.
Typical applications include bridge and strain-gauge front ends, industrial pressure and temperature measurement, portable instrumentation, biomedical instrumentation, and precision current sensing. The dual-channel configuration is particularly useful when a system must amplify two low-level differential signals with closely matched electrical characteristics.
For reliable operation, keep input and output components close to their associated pins, use a low-noise supply arrangement, and verify that the common-mode and output voltages remain inside the device operating limits. The gain resistor should use an appropriate tolerance and temperature coefficient for the required measurement accuracy. Stable reference or sensor grounding is also essential because excessive ground gradients can appear directly as measurement error.
This page combines manufacturer specifications, package and ordering information, validated replacement candidates, application guidance, and design notes to provide a practical engineering reference for the INA2128U/1K.
এর জন্য ড্রপ-ইন বিকল্প INA2128U/1K — একই package, pin-to-pin compatible। ভিন্ন package-এর যেসব পার্টে PCB rework প্রয়োজন সেগুলো বাদ দেওয়া হয়েছে।
এই সিরিজের ভ্যারিয়েন্ট
একই সিরিজের মডেল যেগুলো drop-in compatible INA2128U/1K (একই form factor এবং footprint) — পার্থক্য রয়েছে Architecture, Package.
INA2128U
✅ ড্রপ-ইনমূল্যের জন্য যোগাযোগ করুন
ডেটাশিট দেখুন →INA2128U/1KG4
✅ ড্রপ-ইন📋 রেফারেন্স বিকল্প (ক্যাটালগে নেই)
INA2128UA
✅ ড্রপ-ইনমূল্যের জন্য যোগাযোগ করুন
ডেটাশিট দেখুন →INA2128U/1K সর্বোচ্চ রেটিং ও বৈদ্যুতিক বৈশিষ্ট্য
| Amplifier Type | Dual instrumentation amplifier |
| Number of Channels | 2 channels |
| Architecture | Three-op-amp instrumentation amplifier |
| Gain Range | 1 to 10,000 |
| Gain Configuration | One external resistor per channel |
| Bandwidth at Gain 100 | 200 kHz |
| Input Circuitry | Current-feedback |
| সাপ্লাই ভোল্টেজ | ±18 V maximum |
| Maximum Supply Voltage | 36 V total |
| Input Offset Voltage | 25 uV |
| Input Type | Differential |
| প্যাকেজ | 16-pin SOIC, DW package |
INA2128U/1K 16-pin soic, dw package পিন কনফিগারেশন গাইড
INA2128U/1K (16-pin soic, dw package প্যাকেজ)-এর পিন কনফিগারেশন। এই অ্যানালগ কম্পোনেন্টে ইনপুট, আউটপুট ও পাওয়ার সাপ্লাই পিন রয়েছে। অফসেট নাল, কম্পেনসেশন ও এনেবল পিন কনফিগারেশনের জন্য প্রস্তুতকারকের ডেটাশিট দেখুন। সিগন্যাল কন্ডিশনিং ও অ্যামপ্লিফায়ার সার্কিটের জন্য আদর্শ।
এর জন্য বিস্তারিত পিনআউট ডেটা পাওয়া যায়নি INA2128U/1K.
দেখুন ডেটাশিট সম্পূর্ণ পিন কনফিগারেশনের জন্য।
সাধারণ ব্যবহার
INA2128U/1K এর জন্য উপযুক্ত 6 অ্যাপ্লিকেশনs: Bridge and Strain-Gauge Measurement, Industrial Pressure and Temperature Sensing, Portable Instrumentation, Precision Current Sensing, Biomedical and Diagnostic Instrumentation, Test and Measurement Signal Conditioning.
Bridge and Strain-Gauge Measurement
The INA2128U/1K is well suited to bridge-based strain-gauge and load-cell front ends because its differential three-op-amp architecture amplifies small sensor outputs while rejecting common-mode voltage. Two independent channels can measure two bridge or gauge channels, or one sensing channel and one temperature-compensation channel. Gain is selected from 1 to 10,000 with an external resistor, while the 200 kHz bandwidth at gain 100 supports practical mechanical and process-control bandwidths. The design must verify common-mode range, output swing, excitation stability, resistor tolerance, and sensor grounding.
সুপারিশকৃত
Industrial Pressure and Temperature Sensing
The INA2128U/1K can condition low-level differential outputs from industrial pressure, temperature, and position sensors when common-mode rejection and accurate gain control are essential. Its two channels allow a compact implementation that processes the sensor signal and a reference or compensation signal with consistent amplifier characteristics. Selectable gains from 1 to 10,000 accommodate different transducer sensitivities, and 200 kHz bandwidth at gain 100 is suitable for many industrial monitoring loops. Validate the input common-mode range and output swing against the selected sensor excitation and supply rails.
সুপারিশকৃত
Portable Instrumentation
The dual, low-power architecture of the INA2128U/1K helps reduce component count in portable measurement instruments that acquire two low-level channels. Two independent differential amplifiers share one 16-pin SOIC package, simplifying board allocation while retaining the high input impedance and common-mode rejection expected from an instrumentation amplifier. Gain settings from 1 to 10,000 cover many sensor ranges, and the 200 kHz bandwidth at gain 100 supports moderate-speed acquisition. Battery-powered designs should verify quiescent current and active current from the manufacturer electrical table before sizing the power supply.
সুপারিশকৃত
Precision Current Sensing
The INA2128U/1K can amplify differential voltages produced by current-sensing resistors when the measured current is small and common-mode transients are present. Its differential input arrangement avoids referencing one sensor terminal to ground, while selectable gain permits a useful output range for downstream conversion or processing. The dual-channel configuration can monitor two current paths or combine a current measurement with a voltage reference. Designers should check input common-mode limits during switching events, provide low-resistance grounding, and ensure that gain-bandwidth requirements satisfy the measurement bandwidth.
সুপারিশকৃত
Biomedical and Diagnostic Instrumentation
The INA2128U/1K is appropriate for low-level biomedical signal conditioning when the circuit requires differential inputs, high input impedance, and accurate gain selection. Its two channels can process related physiological signals or one signal and a reference, helping reduce board area in compact diagnostic equipment. Gains from 1 to 10,000 can amplify weak sensor outputs, and the differential architecture helps suppress common-mode pickup. The complete signal chain must still satisfy applicable medical-device requirements, including isolation, leakage current, patient protection, noise, and safety validation outside the amplifier itself.
সুপারিশকৃত
Test and Measurement Signal Conditioning
The INA2128U/1K can serve as the analog input stage in laboratory and field test equipment that measures small differential voltages. Two channels permit simultaneous acquisition of a DUT output and a reference or auxiliary measurement without duplicating the complete instrumentation-amplifier circuit. A single external resistor per channel establishes gains from 1 to 10,000, while 200 kHz bandwidth at gain 100 supports many general-purpose measurement tasks. For precision work, select low-tolerance gain resistors, minimize ground-potential differences, and verify input and output limits across the full test range.
সুপারিশকৃত
সুপারিশকৃত পণ্যের সারসংক্ষেপ
এর জন্য ইঞ্জিনিয়ারিং রেফারেন্স ডেটা INA2128U/1K — তুলনা, ডিজাইন গাইডেন্স এবং কমপ্লায়েন্স তথ্য।
নির্বাচন গাইড
বিকল্পের সাথে তুলনা
| পারামিটার | এই পণ্য | INA2128U | INA2128U/1KG4 | INA2128UA |
|---|---|---|---|---|
| Brand | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments |
| Package | 16-pin SOIC (DW) | 16-pin SOIC (DW) | 16-pin SOIC (DW) | 16-pin SOIC |
| Amplifier Configuration | Dual instrumentation amplifier | Dual instrumentation amplifier | Dual instrumentation amplifier | Dual instrumentation amplifier |
মূল পার্থক্যসমূহ
- Two independent precision channels in one package (বনামINA2128U)
- Wide gain range with one-resistor setting (বনামINA2128UA)
- Documented high-gain bandwidth (বনামINA2128U/1KG4)
ডিজাইন নোট
Route each differential input pair as a compact, symmetric path and connect the gain-setting resistor close to the appropriate device pins. Avoid shared copper geometry between sensitive input nodes and keep the instrumentation-amplifier ground return separate from high-current return currents where practical. Ground-potential differences appear directly as input error, so a clean star-ground or carefully controlled return plane can be as important as the amplifier itself.
Verify the common-mode input range, output swing, and supply limits before selecting the gain. A differential amplifier can still clip when either input exceeds its allowable common-mode range, even if the measured difference is small. Also avoid exceeding the recommended external resistor values or omitting the required feedback and gain-network components. Recheck the circuit across minimum supply voltage, maximum sensor output, and temperature extremes.
Use short input traces, a stable reference connection, and filtering located so that capacitor current does not flow through sensitive gain-network traces. The INA2128U/1K provides 200 kHz bandwidth at gain 100, which allows fast-edge noise to propagate into the measurement path. Add input filtering only after checking its effect on settling time and phase margin; excessive capacitance directly at the inputs can alter stability and bandwidth.
কমপ্লায়েন্স তথ্য
Compliance status must be confirmed from the current manufacturer product documentation or declarations for the exact INA2128U/1K ordering code. AEC-Q100 qualification is not applicable to this general-purpose instrumentation amplifier.