INA2128U/1K - Dual Instrumentation Amplifier | Texas Instruments
MPN: INA2128U/1K ✓ 啟用中INA2128U/1K 概覽
An instrumentation amplifier is a specialized amplifier-and-op-amp category designed to amplify small differential signals while rejecting common-mode interference. Its internal three-op-amp architecture provides high input impedance, symmetrical differential inputs, accurate gain control, and straightforward scaling of sensor outputs. Within the broader semiconductor hierarchy, the INA2128 belongs to the precision analog amplifier class and is used as a front-end signal-conditioning component between sensors or measurement networks and data converters.
Key features include two independent amplifiers on one die, a gain range of 1 to 10,000, and current-feedback input circuitry that maintains useful bandwidth at higher gain. The 200 kHz bandwidth quoted at gain 100 makes the device suitable for sensors whose signals must be measured with limited filtering. Its dual-channel arrangement also reduces board area when two independent measurements are required, such as sensing a bridge output and a reference voltage.
The three-op-amp architecture uses external gain-setting resistors and internal precision circuitry. Because the signal path is differential, common-mode voltage and gain errors can be rejected more effectively than with a single ordinary op-amp stage. Designers must nevertheless consider resistor tolerance, input common-mode range, output swing, supply headroom, and stability when adding input and output filtering capacitors.
Typical applications include bridge and strain-gauge front ends, industrial pressure and temperature measurement, portable instrumentation, biomedical instrumentation, and precision current sensing. The dual-channel configuration is particularly useful when a system must amplify two low-level differential signals with closely matched electrical characteristics.
For reliable operation, keep input and output components close to their associated pins, use a low-noise supply arrangement, and verify that the common-mode and output voltages remain inside the device operating limits. The gain resistor should use an appropriate tolerance and temperature coefficient for the required measurement accuracy. Stable reference or sensor grounding is also essential because excessive ground gradients can appear directly as measurement error.
This page combines manufacturer specifications, package and ordering information, validated replacement candidates, application guidance, and design notes to provide a practical engineering reference for the INA2128U/1K.
直接替換替代品,適用於 INA2128U/1K — 相同封裝,腳位對腳位相容。需重新設計 PCB 的不同封裝零件不列入。
此系列的變體
與下列產品可直接替換的同系列型號: INA2128U/1K (相同外形與佔位) — 差異在於 Architecture, Package.
INA2128U
✅ 直接替換聯絡詢價
查看資料表 →INA2128U/1KG4
✅ 直接替換📋 參考替代品(不在目錄中)
INA2128U/1K 最大額定值與電氣特性
| Amplifier Type | Dual instrumentation amplifier |
| Number of Channels | 2 channels |
| Architecture | Three-op-amp instrumentation amplifier |
| Gain Range | 1 to 10,000 |
| Gain Configuration | One external resistor per channel |
| Bandwidth at Gain 100 | 200 kHz |
| Input Circuitry | Current-feedback |
| 供應電壓 | ±18 V maximum |
| Maximum Supply Voltage | 36 V total |
| Input Offset Voltage | 25 uV |
| Input Type | Differential |
| 封裝 | 16-pin SOIC, DW package |
INA2128U/1K 16-pin soic, dw package 腳位配置指南
INA2128U/1K(16-pin soic, dw package 封裝)的腳位配置。 此類比元件具有輸入、輸出與電源腳位。偏移歸零、補償與致能腳位配置請參閱製造商資料表。適用於訊號調理與放大器電路。
無詳細腳位定義資料: INA2128U/1K.
請參閱 資料表 以查看完整腳位配置。
典型應用
INA2128U/1K 適用於 6 應用s: Bridge and Strain-Gauge Measurement, Industrial Pressure and Temperature Sensing, Portable Instrumentation, Precision Current Sensing, Biomedical and Diagnostic Instrumentation, Test and Measurement Signal Conditioning.
Bridge and Strain-Gauge Measurement
The INA2128U/1K is well suited to bridge-based strain-gauge and load-cell front ends because its differential three-op-amp architecture amplifies small sensor outputs while rejecting common-mode voltage. Two independent channels can measure two bridge or gauge channels, or one sensing channel and one temperature-compensation channel. Gain is selected from 1 to 10,000 with an external resistor, while the 200 kHz bandwidth at gain 100 supports practical mechanical and process-control bandwidths. The design must verify common-mode range, output swing, excitation stability, resistor tolerance, and sensor grounding.
推薦
Industrial Pressure and Temperature Sensing
The INA2128U/1K can condition low-level differential outputs from industrial pressure, temperature, and position sensors when common-mode rejection and accurate gain control are essential. Its two channels allow a compact implementation that processes the sensor signal and a reference or compensation signal with consistent amplifier characteristics. Selectable gains from 1 to 10,000 accommodate different transducer sensitivities, and 200 kHz bandwidth at gain 100 is suitable for many industrial monitoring loops. Validate the input common-mode range and output swing against the selected sensor excitation and supply rails.
推薦
Portable Instrumentation
The dual, low-power architecture of the INA2128U/1K helps reduce component count in portable measurement instruments that acquire two low-level channels. Two independent differential amplifiers share one 16-pin SOIC package, simplifying board allocation while retaining the high input impedance and common-mode rejection expected from an instrumentation amplifier. Gain settings from 1 to 10,000 cover many sensor ranges, and the 200 kHz bandwidth at gain 100 supports moderate-speed acquisition. Battery-powered designs should verify quiescent current and active current from the manufacturer electrical table before sizing the power supply.
推薦
Precision Current Sensing
The INA2128U/1K can amplify differential voltages produced by current-sensing resistors when the measured current is small and common-mode transients are present. Its differential input arrangement avoids referencing one sensor terminal to ground, while selectable gain permits a useful output range for downstream conversion or processing. The dual-channel configuration can monitor two current paths or combine a current measurement with a voltage reference. Designers should check input common-mode limits during switching events, provide low-resistance grounding, and ensure that gain-bandwidth requirements satisfy the measurement bandwidth.
推薦
Biomedical and Diagnostic Instrumentation
The INA2128U/1K is appropriate for low-level biomedical signal conditioning when the circuit requires differential inputs, high input impedance, and accurate gain selection. Its two channels can process related physiological signals or one signal and a reference, helping reduce board area in compact diagnostic equipment. Gains from 1 to 10,000 can amplify weak sensor outputs, and the differential architecture helps suppress common-mode pickup. The complete signal chain must still satisfy applicable medical-device requirements, including isolation, leakage current, patient protection, noise, and safety validation outside the amplifier itself.
推薦
Test and Measurement Signal Conditioning
The INA2128U/1K can serve as the analog input stage in laboratory and field test equipment that measures small differential voltages. Two channels permit simultaneous acquisition of a DUT output and a reference or auxiliary measurement without duplicating the complete instrumentation-amplifier circuit. A single external resistor per channel establishes gains from 1 to 10,000, while 200 kHz bandwidth at gain 100 supports many general-purpose measurement tasks. For precision work, select low-tolerance gain resistors, minimize ground-potential differences, and verify input and output limits across the full test range.
推薦
推薦產品摘要
工程參考資料,適用於 INA2128U/1K — 比較、設計指引及合規資訊。
選型指南
與替代品比較
| 參數 | 本產品 | INA2128U | INA2128U/1KG4 | INA2128UA |
|---|---|---|---|---|
| Brand | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments |
| Package | 16-pin SOIC (DW) | 16-pin SOIC (DW) | 16-pin SOIC (DW) | 16-pin SOIC |
| Amplifier Configuration | Dual instrumentation amplifier | Dual instrumentation amplifier | Dual instrumentation amplifier | Dual instrumentation amplifier |
主要差異化特點
- Two independent precision channels in one package (對比INA2128U)
- Wide gain range with one-resistor setting (對比INA2128UA)
- Documented high-gain bandwidth (對比INA2128U/1KG4)
設計說明
Route each differential input pair as a compact, symmetric path and connect the gain-setting resistor close to the appropriate device pins. Avoid shared copper geometry between sensitive input nodes and keep the instrumentation-amplifier ground return separate from high-current return currents where practical. Ground-potential differences appear directly as input error, so a clean star-ground or carefully controlled return plane can be as important as the amplifier itself.
Verify the common-mode input range, output swing, and supply limits before selecting the gain. A differential amplifier can still clip when either input exceeds its allowable common-mode range, even if the measured difference is small. Also avoid exceeding the recommended external resistor values or omitting the required feedback and gain-network components. Recheck the circuit across minimum supply voltage, maximum sensor output, and temperature extremes.
Use short input traces, a stable reference connection, and filtering located so that capacitor current does not flow through sensitive gain-network traces. The INA2128U/1K provides 200 kHz bandwidth at gain 100, which allows fast-edge noise to propagate into the measurement path. Add input filtering only after checking its effect on settling time and phase margin; excessive capacitance directly at the inputs can alter stability and bandwidth.
合規資訊
Compliance status must be confirmed from the current manufacturer product documentation or declarations for the exact INA2128U/1K ordering code. AEC-Q100 qualification is not applicable to this general-purpose instrumentation amplifier.