Texas Instruments

INA2128U/1K - Dual Instrumentation Amplifier | Texas Instruments

料号: INA2128U/1K ✓ 量产中
±18 V maximum Vdss 16-pin SOIC, DW package Package
最小起订量: 1 |

INA2128U/1K 概述

The Texas Instruments INA2128U/1K is a dual, low-power instrumentation amplifier with two independent signal channels, selectable gain from 1 to 10,000, and a 16-pin SOIC package. It accepts bipolar input signals, provides a bandwidth of 200 kHz at a gain of 100, and operates from dual power supplies up to ±18 V. A single external gain resistor sets the gain of each channel.

An instrumentation amplifier is a specialized amplifier-and-op-amp category designed to amplify small differential signals while rejecting common-mode interference. Its internal three-op-amp architecture provides high input impedance, symmetrical differential inputs, accurate gain control, and straightforward scaling of sensor outputs. Within the broader semiconductor hierarchy, the INA2128 belongs to the precision analog amplifier class and is used as a front-end signal-conditioning component between sensors or measurement networks and data converters.

Key features include two independent amplifiers on one die, a gain range of 1 to 10,000, and current-feedback input circuitry that maintains useful bandwidth at higher gain. The 200 kHz bandwidth quoted at gain 100 makes the device suitable for sensors whose signals must be measured with limited filtering. Its dual-channel arrangement also reduces board area when two independent measurements are required, such as sensing a bridge output and a reference voltage.

The three-op-amp architecture uses external gain-setting resistors and internal precision circuitry. Because the signal path is differential, common-mode voltage and gain errors can be rejected more effectively than with a single ordinary op-amp stage. Designers must nevertheless consider resistor tolerance, input common-mode range, output swing, supply headroom, and stability when adding input and output filtering capacitors.

Typical applications include bridge and strain-gauge front ends, industrial pressure and temperature measurement, portable instrumentation, biomedical instrumentation, and precision current sensing. The dual-channel configuration is particularly useful when a system must amplify two low-level differential signals with closely matched electrical characteristics.

For reliable operation, keep input and output components close to their associated pins, use a low-noise supply arrangement, and verify that the common-mode and output voltages remain inside the device operating limits. The gain resistor should use an appropriate tolerance and temperature coefficient for the required measurement accuracy. Stable reference or sensor grounding is also essential because excessive ground gradients can appear directly as measurement error.

This page combines manufacturer specifications, package and ordering information, validated replacement candidates, application guidance, and design notes to provide a practical engineering reference for the INA2128U/1K.

直接替换替代料: INA2128U/1K ——相同封装,引脚兼容。需要 PCB 改动的不同封装料号已排除。

本系列中的变体

可与以下型号直接替换的同系列型号: INA2128U/1K (相同外形与封装尺寸) ——差异在于 Architecture, Package.

Texas Instruments
Architecture: Three-op-amp instrumentation-amplifier design
Package: 16-pin SOIC

INA2128U

✅ 直接替换
Texas Instruments
📦 16-pin SOIC (DW)
Dual instrumentation amplifier · Three-op-amp instrumentation-amplifier design · 2 channels · 1 to 10,000 · 1 external resistor · 200 kHz · Current-feedback · Single-ended and differential

联系询价

查看数据手册 →

INA2128U/1KG4

✅ 直接替换
📦 16-pin SOIC (DW)
Same INA2128 dual architecture and 16-pin SOIC footprint; identified as an industrial-temperature ordering variant, with no quantified core electrical difference stated.

📋 参考替代料(不在目录中)

INA2128UA

✅ 直接替换
Texas Instruments
📦 16-pin SOIC
Dual instrumentation amplifier · 2 channels · 1 to 10,000 · 1 external resistor · 200 kHz · 50 uV · 0.5 uV/degree C · 5 nA

联系询价

查看数据手册 →

INA2128U/1K 最大额定值与电气特性

Amplifier Type Dual instrumentation amplifier
Number of Channels 2 channels
Architecture Three-op-amp instrumentation amplifier
Gain Range 1 to 10,000
Gain Configuration One external resistor per channel
Bandwidth at Gain 100 200 kHz
Input Circuitry Current-feedback
电源电压 ±18 V maximum
Maximum Supply Voltage 36 V total
Input Offset Voltage 25 uV
Input Type Differential
封装 16-pin SOIC, DW package

INA2128U/1K 16-pin soic, dw package 引脚配置指南

INA2128U/1K(16-pin soic, dw package 封装)的引脚配置。 该模拟元件具有输入、输出和电源引脚。请参阅制造商数据手册以了解失调调零、补偿和使能引脚配置。适用于信号调理和放大器电路。

INA2128U/1K 的 16-pin soic, dw package 封装引脚图

暂无详细引脚数据: INA2128U/1K.

请参阅 数据手册 以查看完整引脚配置。

典型应用

INA2128U/1K 适用于 6 应用s: Bridge and Strain-Gauge Measurement, Industrial Pressure and Temperature Sensing, Portable Instrumentation, Precision Current Sensing, Biomedical and Diagnostic Instrumentation, Test and Measurement Signal Conditioning.

🏭

Bridge and Strain-Gauge Measurement

The INA2128U/1K is well suited to bridge-based strain-gauge and load-cell front ends because its differential three-op-amp architecture amplifies small sensor outputs while rejecting common-mode voltage. Two independent channels can measure two bridge or gauge channels, or one sensing channel and one temperature-compensation channel. Gain is selected from 1 to 10,000 with an external resistor, while the 200 kHz bandwidth at gain 100 supports practical mechanical and process-control bandwidths. The design must verify common-mode range, output swing, excitation stability, resistor tolerance, and sensor grounding.

🏭

Industrial Pressure and Temperature Sensing

The INA2128U/1K can condition low-level differential outputs from industrial pressure, temperature, and position sensors when common-mode rejection and accurate gain control are essential. Its two channels allow a compact implementation that processes the sensor signal and a reference or compensation signal with consistent amplifier characteristics. Selectable gains from 1 to 10,000 accommodate different transducer sensitivities, and 200 kHz bandwidth at gain 100 is suitable for many industrial monitoring loops. Validate the input common-mode range and output swing against the selected sensor excitation and supply rails.

📱

Portable Instrumentation

The dual, low-power architecture of the INA2128U/1K helps reduce component count in portable measurement instruments that acquire two low-level channels. Two independent differential amplifiers share one 16-pin SOIC package, simplifying board allocation while retaining the high input impedance and common-mode rejection expected from an instrumentation amplifier. Gain settings from 1 to 10,000 cover many sensor ranges, and the 200 kHz bandwidth at gain 100 supports moderate-speed acquisition. Battery-powered designs should verify quiescent current and active current from the manufacturer electrical table before sizing the power supply.

⚡

Precision Current Sensing

The INA2128U/1K can amplify differential voltages produced by current-sensing resistors when the measured current is small and common-mode transients are present. Its differential input arrangement avoids referencing one sensor terminal to ground, while selectable gain permits a useful output range for downstream conversion or processing. The dual-channel configuration can monitor two current paths or combine a current measurement with a voltage reference. Designers should check input common-mode limits during switching events, provide low-resistance grounding, and ensure that gain-bandwidth requirements satisfy the measurement bandwidth.

💊

Biomedical and Diagnostic Instrumentation

The INA2128U/1K is appropriate for low-level biomedical signal conditioning when the circuit requires differential inputs, high input impedance, and accurate gain selection. Its two channels can process related physiological signals or one signal and a reference, helping reduce board area in compact diagnostic equipment. Gains from 1 to 10,000 can amplify weak sensor outputs, and the differential architecture helps suppress common-mode pickup. The complete signal chain must still satisfy applicable medical-device requirements, including isolation, leakage current, patient protection, noise, and safety validation outside the amplifier itself.

🔧

Test and Measurement Signal Conditioning

The INA2128U/1K can serve as the analog input stage in laboratory and field test equipment that measures small differential voltages. Two channels permit simultaneous acquisition of a DUT output and a reference or auxiliary measurement without duplicating the complete instrumentation-amplifier circuit. A single external resistor per channel establishes gains from 1 to 10,000, while 200 kHz bandwidth at gain 100 supports many general-purpose measurement tasks. For precision work, select low-tolerance gain resistors, minimize ground-potential differences, and verify input and output limits across the full test range.

What are the key specifications of INA2128U/1K that engineers should know?
The INA2128U/1K is a dual instrumentation amplifier with two independent channels, selectable gain from 1 to 10,000, and 200 kHz bandwidth at gain 100. According to the Texas Instruments INA2128 datasheet, each channel uses a three-op-amp architecture and one external gain-setting resistor. The device is packaged in a 16-pin SOIC and supports dual supplies up to ±18 V, making it appropriate for bipolar sensor signals, bridge transducers, and precision differential measurements.
What is the operating voltage of INA2128U/1K?
The INA2128U/1K operates from dual power supplies up to ±18 V, equivalent to 36 V across the supply pins. According to the Texas Instruments INA2128 datasheet, the instrument amplifier requires positive and negative supply rails for normal bipolar operation. Exact minimum supply voltages, quiescent current, and undervoltage behavior must be confirmed from the electrical-characteristics table before finalizing a power-supply design or operating from a reduced rail.
How is the gain set on the INA2128U/1K?
Each INA2128U/1K channel sets its gain with one external resistor, supporting gains from 1 to 10,000. According to the Texas Instruments INA2128 datasheet, the differential input stage and internal feedback network determine the closed-loop gain. For accurate measurements, select the resistor tolerance and temperature coefficient appropriate to the required gain error, and place the gain resistor close to the corresponding device pins to minimize parasitic effects.
Where can I download the INA2128U/1K datasheet PDF?
The official INA2128U/1K datasheet PDF is available from the Texas Instruments document link at https://www.ti.com/lit/ds/symlink/ina2128.pdf. It contains the electrical characteristics, gain-setting information, pin configuration, typical performance curves, and application guidance for the complete INA2128 family. Use the ordering information on the manufacturer INA2128 product page to confirm that the INA2128U/1K suffix corresponds to the required 16-pin SOIC configuration.
Where can I find the INA2128U/1K pinout?
The INA2128U/1K pin configuration is shown in the pin-configuration section of the official Texas Instruments INA2128 datasheet. The device uses a 16-pin SOIC package. Because the complete pin-description table is not reproduced on this page, use the manufacturer drawing to assign supply, input, output, reference, gain-resistor, and feedback connections. Verify the exact package code and exposed-pad requirements before laying out or assembling the PCB.
Where can I buy INA2128U/1K and check its current price?
Use the Request a Quote form on this page to request the current INA2128U/1K price, stock position, minimum order quantity, and lead time. The part is listed as a dual, 2-circuit, 16-pin SOIC instrumentation amplifier by Texas Instruments. A request through the form allows the exact INA2128U/1K ordering code, reel packaging, and delivery requirements to be confirmed before an order is placed.
What is the lead time for INA2128U/1K?
The current lead time for INA2128U/1K should be requested through the Request a Quote form on this page. Lead time can vary with order quantity, packaging format, inventory, and production scheduling. When requesting a quotation, identify the required reel quantity, authorized shipment destination, and target delivery date so that supply and logistics can be confirmed for the exact Texas Instruments ordering code.
Is INA2128U/1K currently available for purchase?
INA2128U/1K availability should be confirmed through the Request a Quote form on this page. The manufacturer product page identifies INA2128U/1K as a dual, low-power instrumentation amplifier in a 16-pin SOIC package, while inventory and delivery schedules can change over time. A quotation request provides the current stock status, lot availability, packaging details, and expected lead time for the exact MPN.
What can replace INA2128U/1K?
The closest listed replacements are INA2128U and INA2128U/1KG4 because both use the same 16-pin SOIC configuration and belong to the INA2128 family. The INA2128U differs primarily in ordering or packaging notation, while INA2128U/1KG4 is identified as an industrial-temperature variant. A valid drop-in substitution must still match the gain-setting method, supply limits, common-mode range, output swing, bandwidth, and exact pin assignments before production use.
What is the best drop-in replacement for INA2128U/1K?
INA2128U is the closest listed drop-in candidate for INA2128U/1K because both are Texas Instruments dual INA2128 devices in a 16-pin SOIC package. The family supports gain from 1 to 10,000 with a three-op-amp architecture and current-feedback input circuitry. Confirm the ordering suffix, reel configuration, temperature grade, and supply lifecycle for the assembled quantity before treating the substitution as final.
Is INA2128U/1K suitable for bridge and strain-gauge measurement?
Yes, the INA2128U/1K is suitable for bridge and strain-gauge front ends when the excitation, common-mode range, and output swing remain within its operating limits. Its differential three-op-amp architecture is designed to reject common-mode voltage and amplify small transducer outputs, while selectable gain from 1 to 10,000 supports a broad range of sensor sensitivities. Use stable excitation, grounding, and gain-resistor practices to control measurement error.
When should I choose INA2128U/1K over a single op-amp signal conditioner?
Choose INA2128U/1K when the source is a low-level differential signal, common-mode rejection is important, and the gain must be set accurately from one resistor. Its three-op-amp instrumentation-amplifier architecture provides high input impedance and matched differential behavior that a single ordinary op-amp stage does not reproduce as directly. Two channels also reduce board area when the system must process two independent sensor outputs with consistent scaling.
When should I choose INA2128U/1K over a higher-bandwidth instrumentation amplifier?
Choose INA2128U/1K when the measurement bandwidth can remain within its 200 kHz performance at gain 100 and the required gain falls between 1 and 10,000. A higher-bandwidth amplifier is preferable for faster transients, video-like waveforms, or very high closed-loop gains requiring greater bandwidth. The final choice must be based on the sensor bandwidth, noise target, settling requirements, and usable output range rather than bandwidth alone.
What is the difference between INA2128U/1K and INA2128U/1KG4?
Both INA2128U/1K and INA2128U/1KG4 are 16-pin SOIC dual instrumentation amplifiers in the same INA2128 family, and their ordering references identify an industrial temperature grade. Their practical differences may concern orderable packaging, traceability, or commercial program designation rather than the core amplifier architecture. Confirm the manufacturer ordering table and current product status before substituting one suffix for the other in production.
Is there a verified cross-brand replacement for INA2128U/1K?
No verified cross-brand drop-in replacement is identified for the INA2128U/1K. A suitable substitute must preserve the 16-pin SOIC footprint, differential inputs, external-resistor gain network, ±18 V maximum supply capability, and required bandwidth and common-mode performance. Use the manufacturer cross-reference search to evaluate candidates, then compare the complete electrical tables and pin descriptions before approving a second-source part for a precision measurement design.

工程参考数据: INA2128U/1K ——对比、设计指导和合规信息。

选型指南

Choose INA2128U/1K when the design requires two independent low-level differential channels, resistor-programmed gains from 1 to 10,000, and operation from dual supplies up to ±18 V in a 16-pin SOIC. Its three-op-amp instrumentation-amplifier architecture is especially useful for bridges, strain gauges, pressure sensors, and current-sensing resistors where common-mode rejection and input impedance matter. Choose INA2128U when the non-reel or alternate ordering code better matches procurement and manufacturing requirements. Choose INA2128U/1KG4 when the industrial-temperature ordering designation matches the product qualification plan. Choose INA2128UA only after confirming the full electrical table and pin description. For a cross-brand substitution, verify the footprint, gain network, common-mode range, output swing, bandwidth, noise, accuracy, and supply limits rather than relying only on the instrumentation-amplifier description.

与替代料对比

参数 本产品 INA2128U INA2128U/1KG4 INA2128UA
Brand Texas Instruments Texas Instruments Texas Instruments Texas Instruments
Package 16-pin SOIC (DW) 16-pin SOIC (DW) 16-pin SOIC (DW) 16-pin SOIC
Amplifier Configuration Dual instrumentation amplifier Dual instrumentation amplifier Dual instrumentation amplifier Dual instrumentation amplifier

关键差异点

  • Two independent precision channels in one package (对比 INA2128U)
  • Wide gain range with one-resistor setting (对比 INA2128UA)
  • Documented high-gain bandwidth (对比 INA2128U/1KG4)

设计说明

Route each differential input pair as a compact, symmetric path and connect the gain-setting resistor close to the appropriate device pins. Avoid shared copper geometry between sensitive input nodes and keep the instrumentation-amplifier ground return separate from high-current return currents where practical. Ground-potential differences appear directly as input error, so a clean star-ground or carefully controlled return plane can be as important as the amplifier itself.

Verify the common-mode input range, output swing, and supply limits before selecting the gain. A differential amplifier can still clip when either input exceeds its allowable common-mode range, even if the measured difference is small. Also avoid exceeding the recommended external resistor values or omitting the required feedback and gain-network components. Recheck the circuit across minimum supply voltage, maximum sensor output, and temperature extremes.

Use short input traces, a stable reference connection, and filtering located so that capacitor current does not flow through sensitive gain-network traces. The INA2128U/1K provides 200 kHz bandwidth at gain 100, which allows fast-edge noise to propagate into the measurement path. Add input filtering only after checking its effect on settling time and phase margin; excessive capacitance directly at the inputs can alter stability and bandwidth.

合规信息

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
无铅
Unknown
无卤
Unknown
冲突矿物
Unknown

Compliance status must be confirmed from the current manufacturer product documentation or declarations for the exact INA2128U/1K ordering code. AEC-Q100 qualification is not applicable to this general-purpose instrumentation amplifier.

相关搜索

INA2128U/1K datasheet INA2128U/1K pinout INA2128U/1K datasheet pdf INA2128U/1K replacement INA2128U/1K equivalent INA2128U/1K drop-in substitute INA2128U/1K price INA2128U/1K stock INA2128U vs INA2128UA INA2128 dual instrumentation amplifier INA2128 16-SOIC pinout INA2128 bridge amplifier application

相关元器件 & 术语

Texas Instruments INA2128U/1K INA2128U INA2128U/1KG4 INA2128UA instrumentation amplifier precision analog amplifier amplifier IC semiconductor three-op-amp architecture differential input current-feedback input common-mode rejection gain resistor 16-pin SOIC SOIC family surface-mount package bridge transducer strain gauge pressure sensor current sensing industrial instrumentation portable instrumentation medical instrumentation
快速报价
填写完整信息——我们的销售团队将在 24 小时内回复
料号 制造商 封装 QTY 目标价 小计
✓
报价已提交!

我们将在 24 小时内回复您的邮件

1
询价已提交
2
已收到报价
3
已下单
4
支付
5
已发货
6
已送达
查看询价详情