INA2128U/1K - Dual Instrumentation Amplifier | Texas Instruments
MPN: INA2128U/1K ✓ Hoạt độngINA2128U/1K Tóm tắt
An instrumentation amplifier is a specialized amplifier-and-op-amp category designed to amplify small differential signals while rejecting common-mode interference. Its internal three-op-amp architecture provides high input impedance, symmetrical differential inputs, accurate gain control, and straightforward scaling of sensor outputs. Within the broader semiconductor hierarchy, the INA2128 belongs to the precision analog amplifier class and is used as a front-end signal-conditioning component between sensors or measurement networks and data converters.
Key features include two independent amplifiers on one die, a gain range of 1 to 10,000, and current-feedback input circuitry that maintains useful bandwidth at higher gain. The 200 kHz bandwidth quoted at gain 100 makes the device suitable for sensors whose signals must be measured with limited filtering. Its dual-channel arrangement also reduces board area when two independent measurements are required, such as sensing a bridge output and a reference voltage.
The three-op-amp architecture uses external gain-setting resistors and internal precision circuitry. Because the signal path is differential, common-mode voltage and gain errors can be rejected more effectively than with a single ordinary op-amp stage. Designers must nevertheless consider resistor tolerance, input common-mode range, output swing, supply headroom, and stability when adding input and output filtering capacitors.
Typical applications include bridge and strain-gauge front ends, industrial pressure and temperature measurement, portable instrumentation, biomedical instrumentation, and precision current sensing. The dual-channel configuration is particularly useful when a system must amplify two low-level differential signals with closely matched electrical characteristics.
For reliable operation, keep input and output components close to their associated pins, use a low-noise supply arrangement, and verify that the common-mode and output voltages remain inside the device operating limits. The gain resistor should use an appropriate tolerance and temperature coefficient for the required measurement accuracy. Stable reference or sensor grounding is also essential because excessive ground gradients can appear directly as measurement error.
This page combines manufacturer specifications, package and ordering information, validated replacement candidates, application guidance, and design notes to provide a practical engineering reference for the INA2128U/1K.
Bộ thay thế dễ dàng lắp đặt cho INA2128U/1K — cùng gói, chân-to-chân tương thích. Các bộ phận yêu cầu hàn PCB bị loại trừ.
Các biến thể trong loạt này
Các mẫu cùng loạt có thể lắp đặt dễ dàng tương thích với INA2128U/1K (cùng hình factor và footprint) — khác nhau ở Architecture, Package.
INA2128U
✅ Drop-InLiên hệ để biết giá
Xem tài liệu →INA2128U/1KG4
✅ Drop-In📋 Tham chiếu thay thế (không có trong danh mục)
INA2128UA
✅ Drop-InLiên hệ để biết giá
Xem tài liệu →INA2128U/1K Tỷ lệ tối đa & tính chất điện
| Amplifier Type | Dual instrumentation amplifier |
| Number of Channels | 2 channels |
| Architecture | Three-op-amp instrumentation amplifier |
| Gain Range | 1 to 10,000 |
| Gain Configuration | One external resistor per channel |
| Bandwidth at Gain 100 | 200 kHz |
| Input Circuitry | Current-feedback |
| Điện áp cung cấp | ±18 V maximum |
| Maximum Supply Voltage | 36 V total |
| Input Offset Voltage | 25 uV |
| Input Type | Differential |
| Hộp | 16-pin SOIC, DW package |
Hướng dẫn cấu hình chân INA2128U/1K 16-pin soic, dw package
Cấu hình chân cho INA2128U/1K (16-pin soic, dw package gói). Thành phần số hiệu này có chân đầu vào, đầu ra và nguồn cung cấp. Tham khảo tài liệu thông số kỹ thuật của nhà sản xuất để biết cấu hình chân bù, bù trừ và chân kích hoạt. Hoàn hảo cho điều kiện tín hiệu và mạch khuếch đại.
Không có dữ liệu chân cụ thể sẵn có cho INA2128U/1K.
Tham khảo: tài liệu kỹ thuật cho cấu hình chân đầy đủ.
Ứng dụng tiêu biểu
INA2128U/1K phù hợp cho 6 Áp dụngs: Bridge and Strain-Gauge Measurement, Industrial Pressure and Temperature Sensing, Portable Instrumentation, Precision Current Sensing, Biomedical and Diagnostic Instrumentation, Test and Measurement Signal Conditioning.
Bridge and Strain-Gauge Measurement
The INA2128U/1K is well suited to bridge-based strain-gauge and load-cell front ends because its differential three-op-amp architecture amplifies small sensor outputs while rejecting common-mode voltage. Two independent channels can measure two bridge or gauge channels, or one sensing channel and one temperature-compensation channel. Gain is selected from 1 to 10,000 with an external resistor, while the 200 kHz bandwidth at gain 100 supports practical mechanical and process-control bandwidths. The design must verify common-mode range, output swing, excitation stability, resistor tolerance, and sensor grounding.
Được đề xuất
Industrial Pressure and Temperature Sensing
The INA2128U/1K can condition low-level differential outputs from industrial pressure, temperature, and position sensors when common-mode rejection and accurate gain control are essential. Its two channels allow a compact implementation that processes the sensor signal and a reference or compensation signal with consistent amplifier characteristics. Selectable gains from 1 to 10,000 accommodate different transducer sensitivities, and 200 kHz bandwidth at gain 100 is suitable for many industrial monitoring loops. Validate the input common-mode range and output swing against the selected sensor excitation and supply rails.
Được đề xuất
Portable Instrumentation
The dual, low-power architecture of the INA2128U/1K helps reduce component count in portable measurement instruments that acquire two low-level channels. Two independent differential amplifiers share one 16-pin SOIC package, simplifying board allocation while retaining the high input impedance and common-mode rejection expected from an instrumentation amplifier. Gain settings from 1 to 10,000 cover many sensor ranges, and the 200 kHz bandwidth at gain 100 supports moderate-speed acquisition. Battery-powered designs should verify quiescent current and active current from the manufacturer electrical table before sizing the power supply.
Được đề xuất
Precision Current Sensing
The INA2128U/1K can amplify differential voltages produced by current-sensing resistors when the measured current is small and common-mode transients are present. Its differential input arrangement avoids referencing one sensor terminal to ground, while selectable gain permits a useful output range for downstream conversion or processing. The dual-channel configuration can monitor two current paths or combine a current measurement with a voltage reference. Designers should check input common-mode limits during switching events, provide low-resistance grounding, and ensure that gain-bandwidth requirements satisfy the measurement bandwidth.
Được đề xuất
Biomedical and Diagnostic Instrumentation
The INA2128U/1K is appropriate for low-level biomedical signal conditioning when the circuit requires differential inputs, high input impedance, and accurate gain selection. Its two channels can process related physiological signals or one signal and a reference, helping reduce board area in compact diagnostic equipment. Gains from 1 to 10,000 can amplify weak sensor outputs, and the differential architecture helps suppress common-mode pickup. The complete signal chain must still satisfy applicable medical-device requirements, including isolation, leakage current, patient protection, noise, and safety validation outside the amplifier itself.
Được đề xuất
Test and Measurement Signal Conditioning
The INA2128U/1K can serve as the analog input stage in laboratory and field test equipment that measures small differential voltages. Two channels permit simultaneous acquisition of a DUT output and a reference or auxiliary measurement without duplicating the complete instrumentation-amplifier circuit. A single external resistor per channel establishes gains from 1 to 10,000, while 200 kHz bandwidth at gain 100 supports many general-purpose measurement tasks. For precision work, select low-tolerance gain resistors, minimize ground-potential differences, and verify input and output limits across the full test range.
Được đề xuất
Tóm tắt các sản phẩm được đề xuất
Dữ liệu tham khảo kỹ thuật cho INA2128U/1K — so sánh, hướng dẫn thiết kế và thông tin tuân thủ.
Hướng dẫn chọn lựa
So sánh với các sản phẩm thay thế
| Tham số | Sản phẩm này | INA2128U | INA2128U/1KG4 | INA2128UA |
|---|---|---|---|---|
| Brand | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments |
| Package | 16-pin SOIC (DW) | 16-pin SOIC (DW) | 16-pin SOIC (DW) | 16-pin SOIC |
| Amplifier Configuration | Dual instrumentation amplifier | Dual instrumentation amplifier | Dual instrumentation amplifier | Dual instrumentation amplifier |
Bảo phân biệt quan trọng
- Two independent precision channels in one package (vsINA2128U)
- Wide gain range with one-resistor setting (vsINA2128UA)
- Documented high-gain bandwidth (vsINA2128U/1KG4)
Ghi chú thiết kế
Route each differential input pair as a compact, symmetric path and connect the gain-setting resistor close to the appropriate device pins. Avoid shared copper geometry between sensitive input nodes and keep the instrumentation-amplifier ground return separate from high-current return currents where practical. Ground-potential differences appear directly as input error, so a clean star-ground or carefully controlled return plane can be as important as the amplifier itself.
Verify the common-mode input range, output swing, and supply limits before selecting the gain. A differential amplifier can still clip when either input exceeds its allowable common-mode range, even if the measured difference is small. Also avoid exceeding the recommended external resistor values or omitting the required feedback and gain-network components. Recheck the circuit across minimum supply voltage, maximum sensor output, and temperature extremes.
Use short input traces, a stable reference connection, and filtering located so that capacitor current does not flow through sensitive gain-network traces. The INA2128U/1K provides 200 kHz bandwidth at gain 100, which allows fast-edge noise to propagate into the measurement path. Add input filtering only after checking its effect on settling time and phase margin; excessive capacitance directly at the inputs can alter stability and bandwidth.
Thông tin tuân thủ