MCP3422A3-E/SN - 18-Bit Dual-Channel Delta-Sigma ADC
Teilenummer: MCP3422A3-E/SN ✓ AktivMCP3422A3-E/SN Übersicht
A sigma-delta ADC is a voltage regulator that is designed for high-resolution measurement. In this architecture, the analog input is continuously sampled and converted through noise shaping and digital filtering before being transferred over a serial interface. Within the signal-chain hierarchy, the MCP3422A3-E/SN is an ADC, a data-acquisition IC, and ultimately a signal-conditioning and measurement component.
The converter combines two differential measurement channels with up to 18 bits of resolution. Low-noise delta-sigma conversion is particularly useful when the target signal changes slowly and the required performance emphasizes resolution, linearity, and noise performance rather than high sampling bandwidth. The integrated precision reference removes the need for an external reference supply, helping simplify instrument design and preserve measurement consistency.
The MCP3422A3-E/SN uses a two-wire I²C-compatible serial interface and operates from a single supply in the 2.7 V to 5 V range. These characteristics make it practical for industrial monitoring, portable instrumentation, and embedded sensor systems where low power, small PCB area, and deterministic digital communication are more important than rapid transient sampling.
Typical uses include bridge or ratiometric sensor measurement, current-shunt monitoring, battery-cell voltage acquisition, laboratory data logging, and low-frequency process-control instrumentation. Differential inputs help reject common-mode disturbance when the transducer is referenced near the converter ground, although the input source impedance and settling behavior must be considered in the analog front end.
PCB implementation should keep the analog input traces compact, provide a low-impedance return path, and decouple the supply close to the device. Allow adequate settling time after changing the I²C configuration or channel selection, and confirm that the selected conversion mode satisfies the required measurement bandwidth. This page combines device specifications, same-package alternatives, application guidance, and practical design notes to support component selection and PCB implementation.
Drop-in-Alternativen für MCP3422A3-E/SN – gleiches Gehäuse, Pin-kompatibel. Bauteile mit anderem Gehäuse, die eine PCB-Überarbeitung erfordern, sind ausgeschlossen.
Varianten dieser Serie
Modelle derselben Serie, die drop-in-kompatibel sind mit MCP3422A3-E/SN (gleiche Bauform und Footprint) – abweichend in Package, Differential Input Range, Operating Temperature Range, Digital Interface, Supply Voltage Range.
MCP3422A0-E/SN
✅ Drop-InPreis auf Anfrage
Datenblatt ansehen →MCP3422A1-E/SN
✅ Drop-InPreis auf Anfrage
Datenblatt ansehen →MCP3422A6-E/SN
✅ Drop-InPreis auf Anfrage
Datenblatt ansehen →MCP3422A2-E/SN
✅ Drop-In ⚠️ Spezifikationen ungeprüftPreis auf Anfrage
Datenblatt ansehen →MCP3422A3T-E/SN
✅ Drop-In ⚠️ Spezifikationen ungeprüft📋 Referenzalternative (nicht im Katalog)
MCP3422A3-E/SN Grenzwerte & elektrische Eigenschaften
| ADC Resolution | 18 bit |
| Number of Input Channels | 2 channels |
| Input Architecture | Differential input |
| Conversion Topology | 1 sigma-delta converter |
| Conversion Rate | 3.75 samples/s |
| Internal Reference Voltage | 2.048 V |
| Differential Input Range | ±2.048 V |
| Supply Voltage Range | 2.7 V to 5 V |
| Digital Interface | 2-wire I²C-compatible serial interface |
| Gehäuse | 8-pin SOIC |
| Montageart | Surface mount |
| Automotive Classification | Automotive |
MCP3422A3-E/SN 8-pin soic Pinbelegungsleitfaden
Pinbelegung für MCP3422A3-E/SN (8-pin soic-Gehäuse). Dieses analoge Bauteil verfügt über Eingangs-, Ausgangs- und Versorgungspins. Offset-Null-, Kompensations- und Enable-Pin-Konfigurationen entnehmen Sie dem Herstellerdatenblatt. Ideal für Signalaufbereitung und Verstärkerschaltungen.
Keine detaillierten Pinbelegungsdaten verfügbar für MCP3422A3-E/SN.
Siehe die Datenblatt für die vollständige Pin-Konfiguration.
Typische Anwendungen
MCP3422A3-E/SN ist geeignet für 6 Anwendungs: Industrial Pressure Sensor Acquisition, Battery Cell Voltage Monitoring, Current Shunt Measurement, Portable Environmental Monitoring, Precision Temperature Instrumentation, Laboratory Data Logging.
Industrial Pressure Sensor Acquisition
The MCP3422A3-E/SN fits slow industrial pressure measurements where 18-bit resolution is more useful than high conversion bandwidth. Its two differential input channels can support a sensor front end that rejects common-mode voltage, while the onboard 2.048 V reference provides a defined differential range of ±2.048 V. With a 3.75-sample-per-second rate, the converter is appropriate for pressure, vacuum, and hydraulic monitoring where values change on a seconds-scale basis. The designer should use low-noise sensor excitation, maintain a low-impedance analog return, and verify that the complete signal remains within the converter's input limits.
Empfohlen
Battery Cell Voltage Monitoring
The MCP3422A3-E/SN is suitable for low-rate battery monitoring when the system needs high-resolution voltage measurements without rapid sampling. Its 18-bit converter can resolve small changes in cell voltage, while the 2.7 V to 5 V operating range supports embedded battery-monitoring electronics. The onboard 2.048 V reference and differential inputs help establish repeatable measurements. However, series resistance, cell-connection error, and the ADC input network can dominate accuracy, so the PCB and calibration process should account for those effects rather than treating converter resolution as total system accuracy.
Empfohlen
Current Shunt Measurement
The MCP3422A3-E/SN can measure low-frequency current through a shunt when the differential voltage across the shunt remains inside the ±2.048 V range. Differential input handling helps suppress supply and ground disturbances that would otherwise appear in the measurement. The device's 18-bit resolution supports high sensitivity, and its 3.75-sample-per-second rate is appropriate for energy accounting, motor-current trends, and thermal supervision rather than waveform protection. A Kelvin connection, careful shunt placement, and an RC input network are important for achieving useful accuracy and avoiding pickup from adjacent switching nodes.
Empfohlen
Portable Environmental Monitoring
The MCP3422A3-E/SN suits portable temperature, humidity, and gas-sensor systems that report slowly changing environmental values. Its low conversion rate of 3.75 samples per second reduces the demand on battery capacity compared with continuous high-rate acquisition, while the 18-bit result can preserve fine sensor changes. The 2.7 V to 5 V supply flexibility supports both 3.3 V and 5 V embedded designs. A practical implementation should keep the analog sensor path away from display and wireless circuitry, use local reference and supply decoupling, and avoid adding capacitive loading that would upset the converter's acquisition behavior.
Empfohlen
Precision Temperature Instrumentation
The MCP3422A3-E/SN is appropriate for resistance-based temperature probes and low-level thermocouple front ends when very slow measurements are acceptable. Its 18-bit sigma-delta conversion and differential inputs support accurate bridge or ratiometric measurements, while the onboard 2.048 V reference helps define excitation and conversion behavior. The device's 3.75-sample-per-second rate is suitable for thermal monitoring and calibration stations, not fast thermal-transient analysis. Designers should use matched input filtering, verify cold-junction or reference-junction compensation, and include calibration coefficients appropriate to the probe and analog network.
Empfohlen
Laboratory Data Logging
The MCP3422A3-E/SN can form the measurement core of a compact laboratory logger for slowly varying voltages. Two differential channels, 18-bit resolution, an integrated 2.048 V reference, and an I²C-compatible interface make it useful for recording control outputs, sensor conditions, and test-fixture voltages. Its 3.75-sample-per-second rate is adequate for many environmental and process measurements. For dependable logs, the host should timestamp each conversion, handle I²C bus errors, implement input-overrange detection, and preserve calibration information with the recorded data.
Empfohlen
Zusammenfassung der empfohlenen Produkte
Technische Referenzdaten für MCP3422A3-E/SN – Vergleich, Designhinweise und Compliance-Informationen.
Auswahlhilfe
Vergleich mit Alternativen
| Parameter | Dieses Produkt | MCP3422A0-E/SN | MCP3422A1-E/SN | MCP3422A6-E/SN |
|---|---|---|---|---|
| Brand | Microchip Technology | Microchip Technology | Microchip Technology | Microchip Technology |
| Package | 8-pin SOIC | 8-pin SOIC | 8-pin SOIC | 8-pin SOIC |
| ADC Resolution | 18 bit | 18 bit | 18 bit | 18 bit |
| Input Channels | 2 differential channels | 2 differential channels | 2 differential channels | 2 differential channels |
Wichtigste Unterscheidungsmerkmale
- Low-rate high-resolution conversion mode (vs. MCP3422A1-E/SN)
- Integrated precision measurement reference (vs. MCP3422A0-E/SN)
- Direct SOIC-8 family interchangeability (vs. MCP3422A6-E/SN)
Designhinweise
Route the two differential analog-input paths as short, symmetrical traces and provide a continuous ground reference close to the converter. Place supply-decoupling capacitors at the device's supply and ground pins, and keep the I²C routing separate from sensitive input traces where practical. Differential symmetry helps reduce conversion of PCB-induced disturbance into the measured result.
Do not select the converter solely from its 18-bit nominal resolution. Input noise, source impedance, reference error, PCB leakage, and calibration error can dominate the final measurement accuracy. Also account for the 3.75-sample-per-second conversion rate when configuring acquisition timing. A design that requires faster updates must use a faster converter or a different acquisition strategy.
Apply matched input filtering to both sides of a differential channel and verify the settling behavior at the selected gain and conversion mode. The differential pair should share comparable source impedances and geometry. If the sensor is remote, bring the signals close to the converter before amplification and use guarding or shielding as required to prevent common-mode pickup from becoming a measurement error.
Operate the MCP3422A3-E/SN from a clean 2.7 V to 5 V source and place local decoupling at the IC rather than relying on a distant bulk capacitor. Because the device includes an onboard 2.048 V reference, avoid noisy or high-impedance supply arrangements that could degrade reference stability. Validate the complete rail under the analog load and ensure power-up sequencing does not expose any input beyond its permitted limits.
Compliance-Informationen
The component is identified as automotive in a product listing, but no explicit RoHS, REACH, AEC-Q100, lead-free, halogen-free, or conflict-minerals declaration was found. Confirm compliance for the exact ordering code with the manufacturer before release.