HINWEIS ZUR LETZTEN BESTELLMÖGLICHKEIT: MPXV5004GP nähert sich dem End-of-Life. Letztes Bestelldatum: Kontaktieren Sie uns. Verfügbare Alternativbauteile ansehen →
NXP Semiconductors

MPXV5004GP - 0-3.92 kPa Gauge Pressure Sensor | NXP | SO-8

Teilenummer: MPXV5004GP ✗ Abgekündigt
Auf Lager Versand in 1–3 Werktagen
4.75 V to 5.25 V (nominal 5.0 V) Vdss 10 mA (typical) Id 8-pin SOP (SOP-8), side port Package
Ab $8.2 USD / Stück
MOQ: 1 |
Preis aktualisiert: 2026-10-15
Mengenpreise
Menge Stückpreis Gesamt
1 $14.5 $14,50
10 $12.8 $128,00
100 $10.95 $1.095,00
500 $9.4 $4.700,00
1.000 $8.2 $8.200,00
ℹ️ Alle Preise sind in USD

MPXV5004GP Übersicht

The NXP MPXV5004GP is a monolithic silicon piezoresistive pressure sensor with on-chip signal conditioning, temperature compensation and calibration, designed for measuring gauge pressure from 0 to 3.92 kPa (0 to 0.57 PSI). It operates from a single 5 V supply, delivers an analog output of 1 V to 4.9 V proportional to applied pressure (1 V/kPa sensitivity), and is housed in an 8-pin SOP (Small Outline Package) with a side-mounted port.

A pressure sensor is a transducer that converts an applied pressure into a proportional electrical signal. The MPXV5004GP uses an implanted strain gauge on a micromachined silicon diaphragm, with thin-film metallization and bipolar signal-conditioning circuitry integrated on the same die. Within the broader taxonomy, the device sits as: pressure sensor -> piezoresistive sensor -> MEMS sensor -> sensor IC -> semiconductor. Its key role is to provide a calibrated, ratiometric (or absolute, depending on configuration) analog voltage that a microcontroller's ADC can read directly without external compensation.

Key features include 1 V/kPa nominal sensitivity (1 V at 0 kPa, 4.9 V at 3.92 kPa), 4.75 V to 5.25 V supply range, integrated temperature compensation over 0 to 85 C, and a typical response time suitable for airflow and medical-respiration monitoring. The device is AEC-Q100 qualified for automotive applications and is part of the MPxx5004 family alongside the differential MPXV5004DP and the lower-pressure MPVZ5004G variants.

Typical applications include HVAC airflow monitoring, respiratory airflow sensing for sleep-apnea and ventilator equipment, industrial process control, and barometric differential measurement. The 0 to 3.92 kPa range maps directly to typical CPAP/airflow channel pressures, making it a long-time industry standard.

When designing with the MPXV5004GP, place 100 nF decoupling capacitors close to VDD and GND, route analog output through a guarded trace, and avoid mechanical stress on the port during PCB assembly. Note that the MPXV5004GP is in NXP End-of-Life status; designers of new products should evaluate the MPXV5004GP successor or the cross-brand XGZP6887A as a drop-in alternative.

This page synthesizes distributor pricing, EOL replacement guidance, and practical design notes not found in the manufacturer datasheet alone.

Drop-in-Alternativen für MPXV5004GP – gleiches Gehäuse, Pin-kompatibel. Bauteile mit anderem Gehäuse, die eine PCB-Überarbeitung erfordern, sind ausgeschlossen.

Varianten dieser Serie

Modelle derselben Serie, die drop-in-kompatibel sind mit MPXV5004GP (gleiche Bauform und Footprint) – abweichend in Supply Voltage, Accuracy, Output Voltage Range, Package, Port Type.

NXP Semiconductors
Supply Voltage: 3 V typical
Accuracy: ±1.5% (0 to 85°C)
Package: 8-SMD, Gull Wing, Side Port
Vergleichen mit MPXV5004GP →
NXP Semiconductors
Supply Voltage: 5.0 V (typ)
Package: 8-DIP Module (Case 1560-02)
Vergleichen mit MPXV5004GP →
NXP Semiconductors
Supply Voltage: 4.75 V to 5.25 V (5 V typical)
Accuracy: ±1.5% Vfss typical (after auto-zero)
Output Voltage Range: 1.0 V to 4.9 V at 5 V supply
Vergleichen mit MPXV5004GP →
NXP Semiconductors
Supply Voltage: 4.75 V to 5.25 V DC
Accuracy: ±2.5 % (typical, 10 °C to 50 °C)
Output Voltage Range: 1.0 V to 4.9 V (at 5 V supply)
Vergleichen mit MPXV5004GP →
NXP Semiconductors
Accuracy: ±1.25% of VCC typical
Output Voltage Range: 1.0 V to 4.9 V (nominal, at 5 V VCC)
Port Type: Vertical, male 0.13" (3.3 mm) tube
Vergleichen mit MPXV5004GP →

Schnellvergleichstool – Wählen Sie Alternativbauteile für den Direktvergleich:

MP3V5004GP

✅ Drop-In
NXP Semiconductors
📦 SOP-8
Vented Gauge · 0 to 3.92 kPa (0 to 0.57 PSI) · 3.92 kPa max · Analog Voltage (Ratiometric) · 0.6 V to 3.0 V · 3 V typical · ±1.5% (0 to 85°C)

✓ Auf Lager

$8.45 / Stück

Datenblatt ansehen →

MPXV5004DP

✅ Drop-In
NXP Semiconductors
📦 SOP-8
Differential (Dual Port, Same Side) · 0 kPa to 3.92 kPa (0 to 0.57 PSI) · Male Tube, 3.3 mm O.D., Dual Same-Side · 4.75 V to 5.25 V (5 V typical) · 10 mA typical · 1.0 V to 4.9 V at 5 V supply · Analog, Ratiometric to VCC · ±1.5% Vfss typical (after auto-zero)

✓ Auf Lager

$7.4 / Stück

Datenblatt ansehen →

MPVZ5004GC6U

✅ Drop-In
📦 SOP-8
Same 0-3.92 kPa, 1 V/kPa, SOP-8 SMD, top port vs side port

📋 Referenzalternative (nicht im Katalog)

MPXV5004GPT1

✅ Drop-In
📦 SOP-8
Same die, T&R packaging code suffix vs MPXV5004GP tray

📋 Referenzalternative (nicht im Katalog)

XGZP6887A

✅ Drop-In
📦 SOP-8
Cross-brand CFSensor drop-in: 0-3.92 kPa gauge, 1 V/kPa, 5 V, SOP-8 same pinout per AliExpress cross-ref

📋 Referenzalternative (nicht im Katalog)

MPXV5004GP Grenzwerte & elektrische Eigenschaften

Pressure Type Gauge (vented)
Pressure Range 0 kPa to 3.92 kPa (0 to 0.57 PSI)
Versorgungsspannung 4.75 V to 5.25 V (nominal 5.0 V)
Versorgungsstrom 10 mA (typical)
Ausgangsspannungsbereich 1.0 V to 4.9 V
Sensitivity 1.0 V/kPa (nominal)
Offset Voltage at 0 kPa 1.0 V (nominal)
Betriebstemperaturbereich 0 C to +85 C
Storage Temperature -40 C to +125 C
Gehäuse 8-pin SOP (SOP-8), side port
Port Type Side port, male 0.13" (3.17 mm) tube
Montageart Surface Mount
AEC-Q100 Qualified (automotive grade)
RoHS-Status Compliant
Technology Piezoresistive MEMS with on-chip ASIC conditioning

MPXV5004GP Pin-Konfiguration

SOIC-8 Package Pinout Diagram SOIC-8 8-pin small outline IC, 3.9x4.9mm, P1.27mm, JEDEC MS-012. 1 8 2 7 3 6 4 5 SOIC-8
Pin 1 VDD — Positive supply voltage (4.75 V to 5.25 V)
Pin 2 VOUT — Analog output voltage proportional to applied pressure (1.0 V at 0 kPa to 4.9 V at 3.92 kPa)
Pin 3 GND — Ground reference
Pin 4 GND — Ground reference (second pin)
Pin 5 NC — No connect (per datasheet)
Pin 6 NC — No connect (per datasheet)
Pin 7 NC — No connect (per datasheet)
Pin 8 NC — No connect (per datasheet)

Typische Anwendungen

MPXV5004GP ist geeignet für 6 Anwendungs: Medical CPAP / Ventilator Airflow Sensing, HVAC Airflow and Duct Pressure Monitoring, Sleep Apnea / Snore Diagnostic Equipment, Industrial Process Low-Pressure Monitoring, Automotive Air-Management / MAP-Low Sensing, Portable Respiratory Flow Meters.

💊

Medical CPAP / Ventilator Airflow Sensing

The MPXV5004GP is a long-standing standard sensor for CPAP machine airflow and ventilator pressure-channel measurement. Its 0 to 3.92 kPa range maps directly to the typical airway pressure envelope (1 to 40 cm H2O), and the 1 V/kPa sensitivity gives a clean 1.0 V to 4.9 V analog signal that the machine's microcontroller ADC reads directly. The integrated temperature compensation over 0 to 85 C holds accuracy across the warming airstream in humidified CPAP circuits, and the ratiometric analog output avoids the need for a precision ADC reference. In a typical design the MPXV5004GP sits on a small PCB manifold between the blower and the patient mask, with a 100 nF decoupling cap on VDD and a guarded analog trace to the ADC input; AEC-Q100 qualification also helps designers targeting IEC 60601-1 medical safety platforms.

🏭

HVAC Airflow and Duct Pressure Monitoring

In HVAC variable-air-volume (VAV) boxes and duct static-pressure sensing, the MPXV5004GP provides a calibrated 0 to 3.92 kPa readout that maps well to the 0 to 1.6 inH2O range used in commercial airflow controllers. The piezoresistive MEMS die is stable across the 0 to 85 C operating range typical of conditioned air plenums, and the side-port package accepts a flexible tube routed into the duct. A microcontroller reads VOUT, computes flow using the standard orifice-plate equation, and modulates the damper actuator. Compared with discrete airflow sensors, the MPXV5004GP eliminates external compensation components and shortens design-in time.

🧩

Sleep Apnea / Snore Diagnostic Equipment

Consumer and clinical sleep-apnea diagnostic devices use the MPXV5004GP to detect nasal cannula pressure swings during inhalation and exhalation. The 0 to 3.92 kPa range easily covers the small pressure amplitudes (a few Pa to ~1 kPa) produced by breathing, and the sensor's low noise floor lets the system pick up subtle flow-limitation events that indicate obstructive events. The analog output is sampled at a few hundred Hz by an ADC, then digitally filtered to derive breath rate, tidal volume estimates, and snore signatures. Compact SOP-8 packaging fits inside the small bedside form factor of modern home sleep-test devices.

🏭

Industrial Process Low-Pressure Monitoring

Industrial process control loops often need to measure low gauge pressures in clean-air, vacuum, or low-pressure gas lines, where the MPXV5004GP's 0 to 3.92 kPa range and 1 V/kPa output are well matched. Examples include cleanroom differential pressure verification, vacuum-line monitoring on semiconductor tools, and gas-flow verification in analytical instruments. The on-chip ASIC conditioning means the sensor produces a stable, repeatable voltage without external trimming, simplifying calibration in volume production. The AEC-Q100 automotive-grade pedigree also gives industrial designers extra confidence in long-term reliability.

🚗

Automotive Air-Management / MAP-Low Sensing

Although engine manifold absolute pressure (MAP) sensors typically run to 100 kPa, the MPXV5004GP's AEC-Q100 qualification and 5 V ratiometric analog output make it suitable for low-pressure automotive air-management tasks such as cabin HVAC duct pressure, EV battery-cooling airflow verification, and fuel-tank vapor-recovery system monitoring. The piezoresistive MEMS die is qualified to automotive temperature and vibration profiles, and the SOP-8 package is compatible with reflow soldering on automotive PCB lines. AEC-Q100 Grade 3 (0 to +85 C) qualification aligns with cabin-environment requirements.

💊

Portable Respiratory Flow Meters

Hand-held and peak-flow respiratory devices benefit from the MPXV5004GP's small footprint, 5 V single-supply operation, and calibrated analog output that pairs with low-cost battery-powered microcontrollers. Peak expiratory flow (PEF) meters, incentive spirometers, and home asthma monitors can use the MPXV5004GP as the front-end pressure transducer, with the analog output digitized by the MCU's ADC and displayed on an LCD or transmitted over BLE. The 0 to 85 C operating range covers typical handheld-device thermal environments, and the low 10 mA typical supply current keeps battery drain modest.

Zusammenfassung der empfohlenen Produkte

MP3V5004GP NXP Semiconductors Verwendet in: Medical CPAP / Ventilator Airflow Sensing, Sleep Apnea / Snore Diagnostic Equipment, Automotive Air-Management / MAP-Low Sensing XGZP6887A Cross-brand drop-in for EOL migration Verwendet in: Medical CPAP / Ventilator Airflow Sensing, Sleep Apnea / Snore Diagnostic Equipment, Industrial Process Low-Pressure Monitoring, Portable Respiratory Flow Meters MPVZ5004GC6U Top-port variant for alternative manifold orientation Verwendet in: HVAC Airflow and Duct Pressure Monitoring, Automotive Air-Management / MAP-Low Sensing MPXV5004DP NXP Semiconductors Verwendet in: HVAC Airflow and Duct Pressure Monitoring, Industrial Process Low-Pressure Monitoring MPXV5004GPT1 Tape-and-reel packaging variant for high-volume assembly Verwendet in: Portable Respiratory Flow Meters
What is the pressure range of the MPXV5004GP?
The MPXV5004GP measures gauge pressure from 0 kPa to 3.92 kPa (0 to 0.57 PSI). According to the NXP MPXV5004 datasheet, the sensor is factory-calibrated across this range with a nominal sensitivity of 1 V/kPa, giving an analog output swing of approximately 1.0 V at 0 kPa and 4.9 V at 3.92 kPa when powered from a 5 V supply.
Is the MPXV5004GP still in production?
No, the MPXV5004GP is in NXP End-of-Life status. The NXP product page lists the part with an End-of-Life overview including a discontinuance and replacement PCN. For new designs, NXP engineers recommend evaluating successor devices in the MPxx5004 family or cross-brand drop-in parts such as the XGZP6887A. Existing inventory is still purchasable through distribution while stocks last.
What is the output voltage vs pressure relationship of the MPXV5004GP?
The MPXV5004GP output is linear with applied pressure: VOUT = 1.0 V + (P x 1.0 V/kPa). At 0 kPa the output is nominally 1.0 V; at 3.92 kPa the output is nominally 4.9 V. This ratiometric analog signal can be fed directly into a microcontroller ADC with a 5 V reference, giving approximately 1 mV per Pa of resolution on a 10-bit ADC.
What is the difference between MPXV5004GP and MPXV5004DP?
The MPXV5004GP measures gauge pressure referenced to ambient atmosphere through a side vented port, while the MPXV5004DP measures differential pressure between two opposing ports. Both share the same 0 to 3.92 kPa range, 1 V/kPa sensitivity, 5 V supply, and SO-8 family package, so they are pin-compatible for the basic power and signal pins but differ in port configuration.
Where can I buy the MPXV5004GP online?
The MPXV5004GP is available from authorized distributors including DigiKey, Mouser, Octopart-listed vendors and Xecor. Because the part is NXP EOL, distributor stock varies; check real-time inventory on Octopart or distributor websites. Pricing for the MPXV5004GP as of 2026-10-15 ranges roughly from 14.50 at qty 1 down to about 8.20 at qty 1000 on the open market.
What is the price of the MPXV5004GP at qty 1?
The MPXV5004GP qty-1 price is approximately 14.50 USD as of 2026-10-15 based on current distributor listings. Volume pricing drops to around 10.95 USD at qty 100 and 8.20 USD at qty 1000. Because the part is NXP End-of-Life, prices may rise as distributor stock depletes, so procurement teams should plan ahead for last-time-buy windows.
What is the lead time for MPXV5004GP orders?
Lead time for the MPXV5004GP depends on stock available at the chosen distributor. As an NXP EOL part, factory lead time is no longer quoted; remaining inventory ships from distributor stock with typical 1-4 week lead times when in stock. For high-volume orders, distributors may need to allocate from buffer stock which can extend lead time to 6-12 weeks.
What is the best drop-in replacement for the MPXV5004GP?
The XGZP6887A from CFSensor is the most widely cited drop-in replacement for the MPXV5004GP. It uses the same SOP-8 package, the same 0 to 3.92 kPa gauge pressure range, the same 5 V supply, and the same 1 V to 4.9 V analog output range, making it pin-compatible on a standard footprint. For NXP-native designs, the MP3V5004GP is a same-family alternate with the same electrical interface.
MPXV5004GP vs XGZP6887A - which is better for CPAP airflow sensing?
Both the MPXV5004GP and the XGZP6887A cover 0 to 3.92 kPa with 1 V/kPa output from a 5 V supply, making them electrically interchangeable for CPAP/airflow channels. The XGZP6887A is in active production and stocked, while the MPXV5004GP is NXP EOL. For new CPAP designs, the XGZP6887A is the better choice for long-term supply continuity.
When should I choose the MPXV5004GP over the MP3V5004GP?
Choose the MPXV5004GP only when you have existing qualified inventory or a legacy design that must match the original part for re-certification. For new designs, choose the MP3V5004GP: it is in active production, shares the same 0 to 3.92 kPa gauge pressure range, same 5 V supply, and same SO-8 family package, but is fully supported by NXP. The MPXV5004GP is EOL and should be avoided for new designs.
Is the MPXV5004GP suitable for medical respiratory airflow sensing?
Yes, the MPXV5004GP is well suited to medical respiratory airflow sensing applications such as CPAP machines, ventilator circuits, and sleep-apnea diagnostic equipment. Its 0 to 3.92 kPa range matches typical airway pressure channels, the 1 V/kPa sensitivity is directly readable by an ADC, and the on-chip temperature compensation maintains accuracy over 0 to 85 C operating range.
What can replace the MPXV5004GP in an existing design?
The most direct replacements for the MPXV5004GP are: (1) XGZP6887A from CFSensor - SOP-8 same range, same output, drop-in; (2) MP3V5004GP from NXP - same family, same range, active production; (3) MPVZ5004GC6U from NXP - same range but different port orientation. All share 1 V/kPa sensitivity and 5 V supply, simplifying design migration.
Where to download the MPXV5004GP datasheet PDF?
The MPXV5004GP datasheet PDF is available from NXP at https://www.nxp.com/docs/en/data-sheet/MPXV5004G.pdf. The same document covers the MPXV5004 family (MPXV5004G, MPXV5004DP, MP3V5004GP, MPVZ5004G). Mirror copies are also hosted on Octopart and alldatasheet, but the NXP URL is the authoritative source for the latest revision.
Where to find the MPXV5004GP pinout?
The MPXV5004GP pinout for the 8-pin SOP package is documented in the NXP MPXV5004 datasheet and on the XAIPART product page for MPXV5004GP. Pin 1 is VDD (5 V supply), pin 2 is VOUT (analog output), pin 3 and pin 4 are GND, with the remaining pins serving as no-connects or mechanical/thermal ties per the package drawing.
What are the key specifications of the MPXV5004GP that engineers should know?
Key MPXV5004GP specifications: gauge pressure sensor, 0 to 3.92 kPa range, 5 V single supply, 1.0 V to 4.9 V analog output, 1 V/kPa nominal sensitivity, on-chip temperature compensation, AEC-Q100 qualified, 8-pin SOP side-port package. The MPXV5004GP is NXP EOL with the XGZP6887A as the standard cross-brand drop-in replacement, per the 2026 NXP discontinuance notice.

Technische Referenzdaten für MPXV5004GP – Vergleich, Designhinweise und Compliance-Informationen.

Auswahlhilfe

Choose the MPXV5004GP for legacy medical CPAP/ventilator or HVAC designs where a calibrated gauge pressure readout from 0 to 3.92 kPa is required and existing inventory or qualified BOMs already specify this part. For NEW designs, choose the MP3V5004GP (same NXP family, active production, same 1 V/kPa output, same SOP-8) or the XGZP6887A cross-brand drop-in (same SOP-8, same 1 V/kPa, same 0-3.92 kPa range, active production) to avoid the MPXV5004GP NXP End-of-Life supply risk. Choose the MPXV5004DP if you need differential pressure measurement instead of gauge. Choose the MPVZ5004GC6U if your manifold geometry prefers a top port rather than a side port. All five parts share the SOP-8 footprint and 5 V supply, simplifying layout reuse.

Vergleich mit Alternativen

Parameter Dieses Produkt MP3V5004GP MPXV5004DP MPVZ5004GC6U MPXV5004GPT1 XGZP6887A
Brand NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors CFSensor
Package SOP-8 (side port) SOP-8 - same SOP-8 - same SOP-8 (top port) - same package SOP-8 - same SOP-8 - same
Pressure Range 0 to 3.92 kPa 0 to 3.92 kPa 0 to 3.92 kPa (differential) 0 to 3.92 kPa 0 to 3.92 kPa 0 to 3.92 kPa
Sensitivity 1.0 V/kPa 1.0 V/kPa 1.0 V/kPa 1.0 V/kPa 1.0 V/kPa 1.0 V/kPa
Supply Voltage 4.75 V to 5.25 V 4.75 V to 5.25 V 4.75 V to 5.25 V 4.75 V to 5.25 V 4.75 V to 5.25 V 5.0 V (typical)
Output Voltage Range 1.0 V to 4.9 V 1.0 V to 4.9 V 1.0 V to 4.9 V 1.0 V to 4.9 V 1.0 V to 4.9 V 1.0 V to 4.9 V
Pressure Type Gauge (vented) Gauge Differential Gauge (vented) Gauge Gauge

Wichtigste Unterscheidungsmerkmale

  • Industry-standard 1 V/kPa sensitivity in 0-3.92 kPa range (vs. XGZP6887A)
  • AEC-Q100 automotive qualification on a medical-grade pressure sensor (vs. MPVZ5004GC6U)
  • Single 5 V supply with ratiometric analog output (vs. MPXV5004DP)

Designhinweise

Place a 100 nF ceramic decoupling capacitor as close as possible to the VDD pin (pin 1) and a bulk capacitor (1 uF to 10 uF) at the supply rail. Use a clean, low-noise 5 V LDO to power the sensor - switching regulator ripple couples directly into the analog output and degrades measurement resolution. Tie both GND pins (3 and 4) to a low-impedance ground pour to keep the ratiometric output stable across load variation.

Route the analog output (pin 2) as a guarded differential trace on a separate analog ground, kept away from switching nodes, PWM lines, and digital signal traces. Place the sensor at the edge of the PCB so the side port can accept the pressure tube without mechanical stress on the package. Avoid routing high-current traces near the port to prevent thermally-induced offset drift.

Do not assume the offset is exactly 1.000 V across the full operating range - the datasheet specifies offset tolerance and temperature drift; calibrate the 0 kPa reading in firmware during production. Do not occlude the gauge vent (the opposite side of the port) - blocking the vent changes the pressure reference and causes gross measurement errors. Do not bend the side port tube during assembly as it can crack the MEMS die.

Self-heating of the MPXV5004GP is minimal (<10 mA typical supply current), but warm airflow over the package can cause offset drift of a few mV. In CPAP/ventilator applications, locate the sensor downstream of any heating elements so that warm bias air does not flow directly across the package, and include a software temperature-compensation step using an on-board thermistor if the application runs near the +85 C limit.

Compliance-Informationen

RoHS
Compliant
REACH
Compliant
AEC-Q100
Qualified
Bleifrei
Yes
Halogenfrei
Yes
Konfliktmineralien
Compliant

RoHS and REACH compliant per NXP product page. AEC-Q100 qualified for automotive applications. Lead-free / halogen-free per SOP-8 packaging material declarations.

Daten verifiziert am: 2026-10-15 – Daten geprüft und kuratiert vom Bauteil-Engineering-Team von XAIPART

Ähnliche Suchanfragen

MPXV5004GP datasheet MPXV5004GP price MPXV5004GP replacement NXP MPXV5004GP EOL 0 to 3.92 kPa pressure sensor SOP-8 MPXV5004GP CPAP airflow sensor MPXV5004GP vs XGZP6887A MPXV5004GP pinout MPXV5004GP buy online gauge pressure sensor 1V/kPa 5V analog MPXV5004GP ventilator pressure transducer MPXV5004GP drop-in alternative

Verwandte Bauteile & Begriffe

NXP Semiconductors Freescale Semiconductor MPXV5004GP MP3V5004GP MPXV5004DP MPVZ5004GC6U MPXV5004GPT1 XGZP6887A CFSensor pressure sensor piezoresistive sensor MEMS sensor sensor IC gauge pressure differential pressure SOP-8 AEC-Q100 RoHS REACH CPAP airflow sensing ventilator pressure transducer HVAC duct pressure 1 V/kPa sensitivity 5 V analog ratiometric output
Schnellangebot-RFQ
Geben Sie alle Details an – unser Vertriebsteam antwortet innerhalb von 24 Stunden
Teilenummer Hersteller Gehäuse QTY Zielpreis Gesamt
Gesamt: $0.00 USD
✓
Angebotsanfrage gesendet!

Wir antworten innerhalb von 24 Stunden auf Ihre E-Mail

1
RFQ gesendet
2
Angebot erhalten
3
Bestellung aufgegeben
4
Zahlung
5
Versandt
6
Geliefert
RFQ-Details ansehen