MPX2010GP - 10 kPa Vented Gauge Pressure Sensor | STMicroelectronics
Teilenummer: MPX2010GP ✓ Aktiv| Menge | Stückpreis | Gesamt |
|---|---|---|
| 1 | $12.5 | $12,50 |
| 10 | $11.3 | $113,00 |
| 100 | $9.85 | $985,00 |
| 500 | $8.4 | $4.200,00 |
| 1.000 | $7.2 | $7.200,00 |
MPX2010GP Übersicht
A pressure sensor is a transducer that converts an applied gas or fluid pressure into a proportional electrical signal. Pressure sensors fit into the sensor hierarchy as follows: pressure sensor -> force/pressure transducer -> MEMS sensor -> semiconductor device. Within this hierarchy, piezoresistive sensors use a strained silicon diaphragm whose resistance changes with mechanical deformation; signal-conditioning circuitry converts this Wheatstone-bridge change into a millivolt-level voltage output that downstream amplifiers can scale to 0-5 V or 4-20 mA.
The MPX2010GP uses a single monolithic silicon diaphragm with an integrated strain gauge and thin-film resistor network. On-chip temperature compensation holds sensitivity within tight limits across the operating range, removing the need for external thermistor networks. The device operates over a -40 C to +125 C range and is specified for 0 to 10 kPa differential or gauge pressure, making it suitable for low-pressure medical, HVAC, and instrumentation uses. The vented gauge port references the back side to ambient pressure, eliminating vacuum-pump calibration.
Typical applications include medical respiration monitors, HVAC variable-air-volume (VAV) controllers, industrial process instrumentation, altimeters, and low-pressure laboratory measurement. The 25 mV full-scale output requires a low-noise instrumentation amplifier (INA, AD620-class) to drive an ADC. The MPX2010GP series remains a workhorse for low-pressure designs and is widely second-sourced.
When designing with this device, route the high-impedance mV signal on a guarded, short trace and add RC low-pass filtering at the amplifier input to suppress RF rectification. Avoid mechanical stress on the plastic port during PCB assembly - the silicone gel isolation only protects the die from chemical and thermal attack, not from mounting force.
This page synthesizes distributor pricing, drop-in alternatives, and practical design notes not found in the manufacturer datasheet.
Drop-in-Alternativen für MPX2010GP – gleiches Gehäuse, Pin-kompatibel. Bauteile mit anderem Gehäuse, die eine PCB-Überarbeitung erfordern, sind ausgeschlossen.
Varianten dieser Serie
Modelle derselben Serie, die drop-in-kompatibel sind mit MPX2010GP (gleiche Bauform und Footprint) – abweichend in Operating Pressure Range, Output Type, Linearity, Mounting Type, Package / Case.
Schnellvergleichstool – Wählen Sie Alternativbauteile für den Direktvergleich:
MPX2010DP
✅ Drop-In✓ Auf Lager
$8.5 / Stück
Datenblatt ansehen →MPXV2010GP
✅ Drop-In✓ Auf Lager
$8.62 / Stück
Datenblatt ansehen →MPXM2010GS
✅ Drop-In✓ Auf Lager
$5.62 / Stück
Datenblatt ansehen →MPX2010GSX
✅ Drop-In✓ Auf Lager
$10.25 / Stück
Datenblatt ansehen →XGZP191
✅ Drop-In📋 Referenzalternative (nicht im Katalog)
MPX2010GP
✅ Drop-In✓ Auf Lager
$7.2 / Stück
Datenblatt ansehen →MPX2010GP Grenzwerte & elektrische Eigenschaften
| Pressure Type | Vented Gauge |
| Operating Pressure Range | 0 kPa to 10 kPa (0 to 1.45 PSI) |
| Sensitivity (Full-Scale Span) | 25 mV typical at 10 V excitation |
| Ausgangsspannungsbereich | 0 mV to 25 mV (10 V supply) |
| Offset (Zero Pressure) | 0 mV nominal |
| Supply Voltage (Excitation) | 10 V DC typical (max per datasheet) |
| Versorgungsstrom | 6 mA DC typical |
| Response Time | 1 ms typical |
| Temperature Compensation | On-chip, calibrated |
| Betriebstemperaturbereich | -40 C to +125 C |
| Storage Temperature Range | -40 C to +125 C |
| Port Style | Male, 0.19 inch (4.93 mm) tube, vented gauge |
| Gehäuse / Bauform | 4-SIP Module (Case 344B-01) |
| Montageart | Through-Hole (SIP) |
| Media Compatibility | Dry gases (silicone gel isolation) |
| RoHS-Status | Compliant |
MPX2010GP Pin-Konfiguration
| Pin 1 | Vs+ — Bridge excitation supply (10 V DC typical) |
| Pin 2 | +Vout — Differential positive output (mV-level) |
| Pin 3 | GND — Bridge excitation return / common |
| Pin 4 | -Vout — Differential negative output (mV-level) |
Typische Anwendungen
MPX2010GP ist geeignet für 6 Anwendungs: Medical Respiration / Airway Pressure Sensing, HVAC Variable-Air-Volume (VAV) Controllers, Industrial Process Low-Pressure Monitoring, Barometric Altimeter / Weather Station, Portable Handheld Pneumatic Tools, Laboratory Low-Pressure Measurement.
Medical Respiration / Airway Pressure Sensing
The MPX2010GP's 0-10 kPa vented-gauge range aligns directly with human airway and spirometer pressure envelopes (typical peak inspiratory pressure < 5 kPa). The on-chip temperature compensation holds span accuracy across body-temperature variation, simplifying calibration in CPAP, ventilator, and incentive-spirometer designs. The silicone-gel isolation accepts humidified breathing gas without sensor damage. Pair the 25 mV output with a low-noise INA333 or AD620 instrumentation amplifier to drive an isolated medical ADC; the result is a Class-IF-ready pressure channel for IEC 60601-compliant designs.
Empfohlen
HVAC Variable-Air-Volume (VAV) Controllers
Building-automation VAV boxes operate in the 0-1.5 PSI duct-pressure band, an exact match for the MPX2010GP's 0-10 kPa (1.45 PSI) full-scale range. The vented-gauge port references ambient, eliminating vacuum-pump calibration on commissioning. The 1 ms response time tracks rapid damper-induced pressure transients without lag. Combined with a low-cost microcontroller ADC (through an INA), this sensor delivers accurate airflow estimation while the on-chip temp-comp ensures stable readings across 0-50 C rooftop HVAC environments.
Empfohlen
Industrial Process Low-Pressure Monitoring
Cleanroom differential pressure, filter clogging detection, and laboratory vacuum/positive-pressure enclosures typically operate in the 0-10 kPa band. The MPX2010GP's linear mV output and ratiometric 10 V excitation integrate cleanly into 4-20 mA loop transmitters via an INA-x-V-to-I stage. The SIP package with 4.93 mm male port accepts standard pneumatic tubing for rapid panel-mount integration. The -40 to +125 C operating range covers outdoor and process-side environments.
Empfohlen
Barometric Altimeter / Weather Station
Although absolute barometric pressure is typically 100 kPa, weather-balloon and indoor-altimeter designs often measure small differential pressure above local baseline. The MPX2010GP vented-gauge reference and 0-10 kPa span let designers subtract local barometric offset and resolve sub-100 m altitude resolution. The 1 ms response captures gust events, and the SIP port simplifies tubing to a reference chamber. Add a low-pass RC filter to suppress wind-induced acoustic noise.
Empfohlen
Portable Handheld Pneumatic Tools
Battery-powered nailers, tire inflators, and pneumatic-tool regulators rely on low-cost pressure feedback in the 0-1.5 PSI range. The MPX2010GP's 6 mA supply current and 10 V excitation are compatible with a boost-converter-fed portable rail. The through-hole SIP package absorbs vibration better than SMT-only alternatives in shock-prone tools. The on-chip calibration eliminates per-unit trim, supporting high-volume consumer-tool manufacturing.
Empfohlen
Laboratory Low-Pressure Measurement
Research instruments measuring gas chromatography column back-pressure, vacuum-chamber low-pressure monitoring, and microfluidic device pressure all sit comfortably within 0-10 kPa. The MPX2010GP's linear 25 mV span and calibrated offset simplify software calibration; the silicone-gel isolation accepts clean dry gases used in lab environments. The 4.93 mm tube port connects directly to standard 1/8 inch pneumatic fittings via inexpensive adapters, easing lab-bench integration.
Empfohlen
Zusammenfassung der empfohlenen Produkte
Technische Referenzdaten für MPX2010GP – Vergleich, Designhinweise und Compliance-Informationen.
Auswahlhilfe
Vergleich mit Alternativen
| Parameter | Dieses Produkt | MPX2010DP | MPXV2010GP | MPXM2010GS | XGZP191 | MPX2010GP (NXP) |
|---|---|---|---|---|---|---|
| Brand | STMicroelectronics | STMicroelectronics | STMicroelectronics | STMicroelectronics | CFSensor | NXP Semiconductors |
| Package | 4-SIP (Case 344B-01) | 4-SIP (Case 344-15) - same SIP family | SOP (SMT) | SMT small-outline | SIP-compatible 10 kPa port | 4-SIP (Case 344B-01) - identical |
| Pressure Range | 0 to 10 kPa | 0 to 10 kPa | 0 to 10 kPa | 0 to 10 kPa | 0 to 10 kPa | 0 to 10 kPa |
| Output Span (10 V) | 25 mV typical | 25 mV | 25 mV | 25 mV | ~25 mV (manufacturer-stated) | 25 mV |
| Pressure Type | Vented Gauge | Differential (non-vented) | Vented Gauge | Vented Gauge | Gauge (vented) | Vented Gauge |
| Mounting Type | Through-Hole (SIP) | Through-Hole (SIP) | Surface Mount | Surface Mount | Through-Hole | Through-Hole (SIP) |
| On-Chip Temp Compensation | Yes | Yes | Yes | Yes | Yes (per manufacturer) | Yes |
Wichtigste Unterscheidungsmerkmale
- On-chip temperature compensation (vs. Discrete Wheatstone-bridge pressure sensors)
- Vented gauge port reference (vs. MPX2010DP (differential, non-vented))
- Second-source availability across NXP and ST (vs. Single-source competitors)
Designhinweise
The MPX2010GP outputs only 25 mV full-scale, so PCB layout is critical. Route the four bridge traces as a guarded differential pair with the guard driven by a unity-gain buffer of the common-mode voltage. Keep trace length under 25 mm, place the instrumentation amplifier within 30 mm of the sensor, and add a 1-10 kHz RC low-pass filter on each input to suppress RF rectification that can otherwise appear as a DC offset error.
Do not apply fluids directly to the silicone gel - the gel isolates the die from chemical attack but is not a sealed pressure port. Use dry gases only. Also avoid mechanical stress on the plastic port during PCB assembly; clamp the body, not the port. Excitation above 12 V DC can permanently damage the bridge.
Use a star-ground topology: ground the sensor excitation return at the same point as the instrumentation amplifier reference pin to eliminate ground-loop errors. Add 100 nF ceramic decoupling at the bridge Vs+ pin and 10 uF bulk capacitance. For 4-20 mA loop output designs, place a TVS diode at the loop input to meet IEC 61000-4-2 ESD immunity.
Compliance-Informationen
RoHS and lead-free compliant per STMicroelectronics product page. AEC-Q100 not applicable - this is a pressure sensor, not an automotive-qualified IC. NXP second-source shares the same compliance profile.