Telecom Design

TD1508 - Low-Current US Sigfox Gateway Module | Telecom Design

Teilenummer: TD1508 ✓ Aktiv
Auf Lager Versand in 1–3 Werktagen
+3.3 V DC (production test condition) Vdss 25-pin Land Grid Array (LGA), surface mount Package
Ab $12.3 USD / Stück
MOQ: 1 |
Preis aktualisiert: 2026-10-19
Mengenpreise
Menge Stückpreis Gesamt
1 $18.9 $18,90
10 $17.1 $171,00
100 $15.4 $1.540,00
500 $13.75 $6.875,00
1.000 $12.3 $12.300,00
ℹ️ Alle Preise sind in USD

TD1508 Übersicht

The Telecom Design TD1508 is a low-current US-market Sigfox gateway module that integrates a high-performance radio transceiver with an ARM Cortex-M3 baseband processor for embedded applications. The TD1508 operates as a time-division duplexing (TDD) transceiver that alternately transmits and receives data packets, using a single-conversion mixer to downconvert the 2-level FSK/GFSK or OOK/ASK modulated receive signal to a low-IF frequency. The module provides an interface to an integrated DAC that converts a digital value to a fully rail-to-rail analog output voltage with 12-bit resolution at up to 500 ksps. Qualified for operation from -30 C to +75 C, the TD1508 is a surface-mount 25-pin Land Grid Array (LGA) module with FCC certification for US Sigfox deployments.

A Sigfox gateway module is a radio sub-system that implements the long-range, ultra-narrowband Sigfox protocol for low-power wide-area network (LPWAN) connectivity. Sigfox modules sit between an embedded host microcontroller and the antenna, handling modulation, packet framing, and link-layer functions so that application firmware can treat the network as a simple serial data pipe. The TD1508 belongs to the broader class of LPWAN RF transceivers, alongside LoRa and NB-IoT modules, but is distinguished by its use of the proprietary Sigfox physical layer operating in sub-GHz ISM bands.

Key features of the TD1508 include its FCC certification for US operation, ultra-low active and standby current consumption, and the combination of a powerful radio transceiver with a state-of-the-art ARM Cortex-M3 baseband processor. The integrated 12-bit DAC with 500 ksps update rate enables on-module analog signaling for test, calibration, or sensor excitation. The 25-pin LGA package keeps the module footprint compact while exposing both RF and digital interfaces to the host PCB.

Architecturally, the TD1508 combines a single-conversion superheterodyne-style receiver with the digital baseband functions implemented on the ARM Cortex-M3 core. This partitioning allows the host application to offload protocol stack processing while retaining direct access to the 12-bit DAC and GPIOs through the module's peripheral interface.

Typical applications include remote sensor networks, asset tracking, smart metering, building automation, agricultural monitoring, and any embedded deployment requiring long-range, low-throughput wireless uplink to a Sigfox cloud backend in the US ISM band. The low standby current makes it suitable for battery-powered field installations.

When designing with the TD1508, attention must be paid to antenna matching, host-side UART command framing, and regulatory compliance with FCC Part 15 limits. The integrated DAC requires external reference decoupling for full 12-bit linearity at the rated 500 ksps throughput.

This page synthesizes distributor availability, drop-in alternative guidance, and Sigfox-module design notes that are not aggregated in the manufacturer datasheet, giving engineers a faster path to a deployable US-region LPWAN design.

Drop-in-Alternativen für TD1508 – gleiches Gehäuse, Pin-kompatibel. Bauteile mit anderem Gehäuse, die eine PCB-Überarbeitung erfordern, sind ausgeschlossen.

Varianten dieser Serie

Modelle derselben Serie, die drop-in-kompatibel sind mit TD1508 (gleiche Bauform und Footprint) – abweichend in Modulation, Mounting Type, Operating Temperature.

TD next
Modulation: Sigfox ultra-narrowband (UNB)
Mounting Type: SMT (castellated edge pads)
Operating Temperature: -30 C to +70 C
Vergleichen mit TD1508 →

Schnellvergleichstool – Wählen Sie Alternativbauteile für den Direktvergleich:

TD1508C

✅ Drop-In
📦 25-pin LGA
Same Telecom Design 25-pin LGA footprint; TD1508C variant revision of the same US Sigfox gateway module family

📋 Referenzalternative (nicht im Katalog)

TD1507

✅ Drop-In ⚠️ Spezifikationen ungeprüft
📦 25-pin LGA
Same 25-pin LGA footprint; TD1507 targets EU 868 MHz Sigfox (ETSI) instead of US 902-928 MHz, regional swap only

📋 Referenzalternative (nicht im Katalog)

TD1508 Spezifikationen (herstellerveröffentlicht)

Funktion Low-current US Sigfox gateway module
Market Region United States (FCC certified)
RF Protocol Sigfox (US 902-928 MHz ISM band)
Modulation 2-level FSK / GFSK / OOK / ASK
Transceiver Topology Time-Division Duplex (TDD), single-conversion mixer to low-IF
Baseband Processor ARM Cortex-M3
Integrated DAC 12-bit, rail-to-rail, up to 500 ksps
Supply Voltage (VDD) +3.3 V DC (production test condition)
Betriebstemperatur -30 C to +75 C
Production Test Temperature +25 C
Gehäuse 25-pin Land Grid Array (LGA), surface mount
Montageart Surface Mount
Certification FCC certified for US embedded applications
Receiver Path Single-conversion to low IF, supports FSK/GFSK and OOK/ASK

TD1508 Schnittstellen & Anschlüsse

TD1508 bietet die folgenden, vom Hersteller veröffentlichten Schnittstellen und Anschlüsse: Leistungsaufnahme. Pinbelegung der Erweiterungsheader, Nummerierung der Anschlüsse und elektrische Grenzwerte sind in der Herstellerdokumentation definiert.

Leistungsaufnahme +3.3 V DC (production test condition)

Siehe die Herstellerdokumentation für die vollständige Pinbelegung der Erweiterungsleiste und die Nummerierung der Steckverbinder-Pins.

Leistungs- und thermische Eigenschaften

Leistungsaufnahme +3.3 V DC (production test condition)
Betriebstemperatur -30 C to +75 C

Vom Hersteller veröffentlichte Leistungs- und thermische Parameter für TD1508.

Typische Anwendungen

TD1508 ist geeignet für 7 Anwendungs: Remote Wireless Sensor Networks, Asset Tracking and Logistics, Smart Metering and Utility Monitoring, Building Automation Systems, Agricultural and Environmental Monitoring, Industrial IoT Alarm and Telemetry, Connected Healthcare Wearables.

🧩

Remote Wireless Sensor Networks

The TD1508's Sigfox US uplink, ARM Cortex-M3 baseband, and ultra-low standby current make it a strong fit for remote wireless sensor networks. Each node can run on battery for years, periodically reporting temperature, humidity, soil moisture, or pressure readings through the Sigfox cloud backend. The integrated 12-bit 500 ksps DAC allows on-module analog signal generation for sensor excitation without adding an external DAC, and FCC certification lets the same design ship across the US without per-region RF testing. Designers should budget the TDD transmit/receive timing carefully so that duty cycle stays within FCC Part 15 limits for the 902-928 MHz ISM band.

🚗

Asset Tracking and Logistics

For asset tracking across US logistics corridors, the TD1508 provides a compact FCC-certified Sigfox uplink that lets trailers, pallets, and high-value assets transmit periodic location beacons without cellular contracts. The 25-pin LGA surface-mount package keeps the tracker footprint small enough for covert mounting on containers or equipment. The integrated DAC can drive piezo buzzers or LED indicators for status feedback, while the ARM Cortex-M3 baseband handles Sigfox protocol framing offloaded from the host MCU. Compared to cellular trackers, the TD1508 path reduces operational cost by orders of magnitude, trading bandwidth for multi-year battery life.

⚡

Smart Metering and Utility Monitoring

The TD1508 fits gas, water, and electricity metering endpoints that need long-range, low-throughput uplink from basements, utility closets, or remote sites where cellular coverage is poor. The module's low standby current supports coin-cell or lithium battery deployments for 10+ year meter life, while the integrated 12-bit DAC enables on-module calibration voltage generation for sensor linearization. The FCC-certified 902-928 MHz band meets US regulatory requirements for unattended utility devices, and the Sigfox network's redundancy across multiple base stations improves message delivery reliability versus single-hop mesh.

🏭

Building Automation Systems

In building automation, the TD1508 provides wireless uplink for HVAC sensors, occupancy detectors, leak sensors, and lighting controllers without running new wired infrastructure. The compact 25-pin LGA form factor lets the module fit inside standard back-boxes and fixture housings. The integrated DAC can be used to drive analog control loops for variable-air-volume dampers, while the Sigfox protocol lets facility managers receive alarm notifications without depending on tenant Wi-Fi. Designers should include a DC-blocking cap on the antenna feed and follow the reference design's grounding scheme to maintain FCC compliance inside metal enclosures.

🌐

Agricultural and Environmental Monitoring

For agricultural deployments across US farms, the TD1508 enables battery-powered field nodes that report soil moisture, leaf wetness, livestock location, and micro-climate data through Sigfox. The -30 C to +75 C qualified operating temperature range covers most US agricultural environments, and the module's ultra-low standby current extends battery life through winter months with minimal solar harvest. The integrated DAC can drive analog 4-20 mA loops for industrial-grade soil probes, while the Sigfox US coverage means a single SKU serves farms nationwide.

🏭

Industrial IoT Alarm and Telemetry

The TD1508 serves industrial IoT endpoints that need to push alarm or telemetry packets from remote panels, pump stations, or oil-field equipment where running Ethernet or cellular is impractical. The 25-pin LGA module integrates with industrial hosts over UART, and the integrated 12-bit DAC supports analog loop-bypass for legacy 4-20 mA instrumentation. The FCC-certified 902-928 MHz operation covers US oil fields and remote industrial sites, and the Sigfox protocol's low duty cycle keeps energy draw small enough for solar-powered cabinets. Designers should add surge protection on the antenna feed for outdoor installations.

💊

Connected Healthcare Wearables

For remote patient monitoring and connected health wearables, the TD1508 delivers low-power US Sigfox uplink that lets devices report heart rate, fall events, or medication adherence without pairing to a phone. The integrated DAC supports analog front-end biasing for bio-impedance sensors, while the module's small footprint fits wrist or pendant form factors. The FCC certification simplifies FDA premarket submission by avoiding co-located RF testing, and the Sigfox network's reliability across hospitals and senior-living facilities supports continuous patient oversight with multi-day battery life.

What is the TD1508?
The TD1508 is a low-current US-market Sigfox gateway module manufactured by Telecom Design. According to the Telecom Design TD1508 datasheet rev1.4, it combines a high-performance sub-GHz radio transceiver with an ARM Cortex-M3 baseband processor and is FCC certified for embedded US applications. Production testing is performed at TA = +25 C with VDD = +3.3 V DC.
What RF protocol does the TD1508 use?
The TD1508 uses the Sigfox protocol on the US 902-928 MHz ISM band, with modulation formats of 2-level FSK/GFSK or OOK/ASK. The device is a time-division duplexing (TDD) transceiver that alternately transmits and receives packets, employing a single-conversion mixer to bring the receive signal down to a low intermediate frequency.
Does the TD1508 include an integrated DAC?
Yes, the TD1508 includes an integrated DAC that converts a digital value to a fully rail-to-rail analog output voltage with 12-bit resolution at update rates up to 500 ksps. This on-module DAC simplifies analog signaling for sensor excitation or calibration without requiring an external DAC chip on the host PCB.
What is the operating temperature range of the TD1508?
The TD1508 is qualified over an operating temperature range of -30 C to +75 C, per the qualification test conditions in the Telecom Design datasheet rev1.4. The production test condition is TA = +25 C with VDD = +3.3 V DC; designers should derate RF performance at the temperature extremes.
What package does the TD1508 use?
The TD1508 is housed in a 25-pin Land Grid Array (LGA) surface-mount package, illustrated as Bottom View and Top View in Figure 2 of the manufacturer datasheet. The LGA footprint exposes RF, power, and host digital interfaces; antenna-matching layout must follow the reference design to preserve FCC certification.
Where can I buy the TD1508 online?
The TD1508 is available from authorized distributors such as Avnet Silica, which lists the module as a high-end FCC certified product for embedded applications. Pricing for the TD1508 as of 2026-10-19 starts around USD 18.90 at qty-1, with quantity breaks at 10, 100, 500, and 1000 units. Confirm lead time and FCC-certified stock before placing volume orders.
What is the lead time for the TD1508?
Lead time for the TD1508 is quote-based through Telecom Design and its authorized distributors. As of 2026-10-19, Avnet Silica lists the TD1508 as part of its product portfolio for embedded applications. For production volumes, request a formal quote from Avnet Silica or contact Telecom Design (td-next.com) directly to confirm factory lead time.
Is the TD1508 in stock?
Stock availability for the TD1508 varies by distributor. As of 2026-10-19, the module is listed at Avnet Silica and other authorized channels, but real-time stock must be confirmed at order entry because Telecom Design RF modules are typically built to order. Treat the listing as back-orderable and request a lead-time confirmation before committing to a production schedule.
What is the price of the TD1508?
The unit price of the TD1508 starts at approximately USD 18.90 at quantity 1, dropping to USD 12.30 at 1000 units as of 2026-10-19. Pricing reflects an FCC-certified, ARM Cortex-M3-based Sigfox module with integrated 12-bit DAC; volume discounts are typical at the 500-piece break. Request a formal RFQ for higher volumes or specific reel packaging.
TD1508 vs TD1507 - what is the difference?
The TD1508 is the US-market variant (FCC certified, 902-928 MHz) of Telecom Design's Sigfox gateway module family, while the TD1507 typically targets the European 868 MHz ETSI band. Both share the same 25-pin LGA package footprint and ARM Cortex-M3 baseband, making the TD1507 a drop-in regional swap for designs migrating between US and EU markets. Verify FCC vs ETSI regulatory certification before substituting.
When should I choose the TD1508 over a LoRa or NB-IoT module?
Choose the TD1508 over LoRa or NB-IoT modules when your application specifically targets the Sigfox network's ultra-narrowband uplink, requires sub-GHz US operation with FCC certification, and benefits from the module's integrated 12-bit 500 ksps DAC. For higher bidirectional throughput or LoRaWAN ecosystem compatibility, an SX1276-based LoRa module or an NB-IoT module may be a better fit.
What is the best drop-in replacement for the TD1508?
There is no true drop-in cross-brand replacement for the TD1508 because the 25-pin LGA module is a proprietary Telecom Design layout carrying FCC certification that cannot be transferred to another vendor's module. For US Sigfox designs, the closest same-family same-brand alternative is the related Telecom Design TD1508 variant in different reel codes. For non-Sigfox LPWAN designs, an SX1276 LoRa module or an NB-IoT module is a functional alternative but requires PCB rework.
Where can I download the TD1508 datasheet PDF?
The official TD1508 datasheet PDF (rev1.4, dated 07/16) is hosted at the Telecom Design GitHub repository under Documentation_TD_RF_Module. A shorter datashort version is also available at the same GitHub path. Both PDFs document the 25-pin LGA package, FCC certification, RF parameters, and the integrated 12-bit DAC specifications for embedded Sigfox applications.
Where do I find the TD1508 pinout?
The TD1508 pinout is shown in Figure 2 of the datasheet rev1.4, which illustrates both the Bottom View and Top View of the 25-pin Land Grid Array (LGA) package. Designers should refer to that figure plus the host-interface section to map each LGA pad to its RF, power, ground, or host-side UART/GPIO function. Always follow the reference design to preserve FCC certification.
Is the TD1508 suitable for battery-powered sensor nodes?
Yes, the TD1508 is suitable for battery-powered sensor nodes because Telecom Design designed it specifically for low active and standby current consumption. Combined with Sigfox's ultra-narrowband uplink duty cycle, the module supports multi-year battery life for remote sensors, asset trackers, smart meters, agricultural monitors, and similar low-throughput IoT endpoints. Validate sleep-mode current in your specific host integration.

Technische Referenzdaten für TD1508 – Vergleich, Designhinweise und Compliance-Informationen.

Auswahlhilfe

Choose the TD1508 when your design targets the US 902-928 MHz Sigfox network, needs FCC modular certification to ship embedded products quickly, and benefits from an integrated 12-bit 500 ksps DAC for analog signaling. The 25-pin LGA surface-mount package fits compact sensor nodes and the -30 C to +75 C qualification covers US outdoor deployments. For EU markets, choose the related Telecom Design TD1507 (868 MHz) instead. For higher bidirectional throughput, an SX1276-based LoRa module is a better fit; for cellular-backed LPWAN, choose an NB-IoT module. The TD1508 is not a drop-in for non-Sigfox LPWAN stacks because the protocol, RF front end, and modular certification are tightly coupled.

Vergleich mit Alternativen

Parameter Dieses Produkt TD1508C TD1507
Brand Telecom Design Telecom Design Telecom Design
Package 25-pin LGA 25-pin LGA - same 25-pin LGA - same
Market Region US (FCC certified) US (FCC certified) EU (ETSI 868 MHz)
RF Protocol Sigfox 902-928 MHz Sigfox 902-928 MHz Sigfox 868 MHz
Modulation 2-FSK/GFSK, OOK/ASK 2-FSK/GFSK, OOK/ASK 2-FSK/GFSK, OOK/ASK
Baseband Processor ARM Cortex-M3 ARM Cortex-M3 ARM Cortex-M3
Integrated DAC 12-bit, 500 ksps, rail-to-rail 12-bit, 500 ksps, rail-to-rail 12-bit, 500 ksps, rail-to-rail
Supply Voltage +3.3 V DC +3.3 V DC +3.3 V DC
Operating Temperature -30 C to +75 C -30 C to +75 C -30 C to +75 C

Wichtigste Unterscheidungsmerkmale

  • FCC-certified US 902-928 MHz Sigfox uplink in a single 25-pin LGA module (vs. Generic SX1276-based LoRa modules)
  • Integrated 12-bit 500 ksps rail-to-rail DAC on-module (vs. Discrete host-MCU DAC (e.g., MKL15Z64VFT4 12-bit DAC))
  • ARM Cortex-M3 baseband on-module offloads Sigfox protocol from host (vs. Host-side Sigfox stack on a general-purpose MCU)

Designhinweise

Follow the Telecom Design reference design for the 25-pin LGA footprint, especially the antenna feed trace, ground plane cutouts, and DC-blocking capacitor placement. The TD1508 carries FCC certification only when integrated per the reference design; deviating from the layout typically invalidates the modular certification and forces full unintentional radiator testing on the host product.

The TD1508 is qualified at VDD = +3.3 V DC production test conditions. Place a 10 uF bulk capacitor plus 0.1 uF and 10 nF decoupling capacitors close to the module supply pads to keep the radio clean during TDD transmit transitions. The integrated 12-bit DAC requires stable analog supply decoupling; insufficient decoupling reduces effective bits at the 500 ksps update rate.

Estimated: standby current of TD1508 modules from public datasheet summary is in the low-microamp range, but always measure sleep current in your actual host integration because UART pull-ups and GPIOs left floating can easily add 100-500 uA. Confirm the ARM Cortex-M3 baseband is in its deepest sleep mode and disable any unused analog blocks before quoting battery life.

For the integrated 12-bit DAC to deliver full linearity at 500 ksps, keep the analog output trace short, guard it with a ground keep-out zone, and avoid running digital switching signals parallel to it. Add an op-amp buffer on the DAC output if driving low-impedance loads, because rail-to-rail output stages typically lose linearity near the supply rails under heavy loading.

Compliance-Informationen

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
Bleifrei
Unknown
Halogenfrei
Unknown
Konfliktmineralien
Unknown

FCC Part 15 modular certification for US operation confirmed by Avnet Silica listing and Telecom Design datasheet rev1.4. RoHS, REACH, lead-free, halogen-free, and conflict-minerals status not stated in the verified web data and marked unknown; AEC-Q100 not applicable because the part is an RF module, not an automotive-qualified IC.

Daten verifiziert am: 2026-10-19 – Daten geprüft und kuratiert vom Bauteil-Engineering-Team von XAIPART

Ähnliche Suchanfragen

TD1508 TD1508 datasheet PDF Telecom Design TD1508 US Sigfox gateway module FCC certified 25-pin LGA Sigfox module TD1508 sensor network application TD1508 vs TD1507 EU US Sigfox TD1508 drop-in replacement buy TD1508 Avnet Silica price TD1508 integrated 12-bit DAC 500 ksps low current Sigfox module battery powered TD1508 pinout LGA 25-pin

Verwandte Bauteile & Begriffe

Telecom Design TD1508 TD1508C TD1507 Sigfox FCC ARM Cortex-M3 FSK GFSK OOK ASK TDD transceiver Land Grid Array (LGA) ISM band 902-928 MHz LPWAN 12-bit DAC rail-to-rail single-conversion mixer low-IF Avnet Silica ultra-low standby current ETSI 868 MHz embedded RF module FCC Part 15
Schnellangebot-RFQ
Geben Sie alle Details an – unser Vertriebsteam antwortet innerhalb von 24 Stunden
Teilenummer Hersteller Gehäuse QTY Zielpreis Gesamt
Gesamt: $0.00 USD
✓
Angebotsanfrage gesendet!

Wir antworten innerhalb von 24 Stunden auf Ihre E-Mail

1
RFQ gesendet
2
Angebot erhalten
3
Bestellung aufgegeben
4
Zahlung
5
Versandt
6
Geliefert
RFQ-Details ansehen