1ED020I12FA2XUMA2 - 2A Isolated Gate Driver | Infineon
MPN: 1ED020I12FA2XUMA2 ✓ فعال1ED020I12FA2XUMA2 نمای کلی
A galvanically isolated gate driver is a specialized power-management IC that sits between a low-voltage microcontroller or DSP and the gate of a high-voltage switching transistor such as an IGBT, SiC MOSFET, or GaN HEMT. Its role in the broader signal-chain hierarchy is: gate driver -> power transistor driver -> power management IC -> semiconductor. By providing both logic-level translation and reinforced safety isolation in one package, isolated gate drivers eliminate the need for optocouplers or discrete bootstrap supplies in many topologies, simplifying PCB layout and improving long-term reliability.
Key features of the 1ED020I12FA2 include integrated protection functions such as DESAT detection, active Miller clamp, and under-voltage lockout (UVLO) for both the primary and secondary sides. The 2 A peak source/sink output stage drives IGBT modules directly without external buffer stages. Typical propagation delay is around 150 ns with excellent channel-to-channel matching for half-bridge synchronization, while the coreless transformer delivers 100 kV/µs common-mode transient immunity (CMTI) - critical for SiC switching edges above 50 V/ns.
Architecturally, the device uses a differential CT-based isolation barrier that replaces the LED-photodiode link of optocouplers. This eliminates opto-degradation concerns (CTR drift over temperature and age) and supports operation from -40 °C to +125 °C. The integrated 2 A output stage reduces BOM count by removing the need for an external booster, and the wide VCC2 range (typically up to 25 V) supports both 15 V and 18 V gate-drive rails used by SiC and IGBT power modules.
Typical applications include automotive traction inverters, onboard EV chargers, industrial servo drives, solar string inverters, and uninterruptible power supplies. The automotive qualification (AEC-Q100) makes it particularly suitable for xEV main inverters where reinforced isolation is mandatory per IEC 60664.
When designing with the 1ED020I12FA2, ensure the DESAT blanking time is properly tuned to the power device's switching characteristics to avoid false triggering during normal turn-on transients. The exposed pad of the PG-DSO-20 must be soldered to a sufficiently large copper pour for thermal dissipation of the 2 A gate-charge pulses.
This page synthesizes distributor pricing, drop-in alternatives, and practical design notes not found in the manufacturer datasheet.
جایگزینهای drop-in برای 1ED020I12FA2XUMA2 — همان پکیج، سازگار پینبهپین. قطعات با پکیج متفاوت که نیاز به تغییر PCB دارند مستثنی هستند.
گونهها در این سری
مدلهای همسری که جایگزین مستقیم هستند برای 1ED020I12FA2XUMA2 (همان فرمفاکتور و فوتپرینت) — متفاوت در Driver Type, Isolation Technology, Package.
1ED020I12FAXUMA2
✅ جایگزین مستقیم📋 جایگزین مرجع (خارج از کاتالوگ)
1ED020I12B2XUMA1
✅ جایگزین مستقیمبرای قیمت تماس بگیرید
مشاهده دیتاشیت ←1ED020I12FA
✅ جایگزین مستقیم📋 جایگزین مرجع (خارج از کاتالوگ)
1ED020I12FA2XUMA2 حداکثر مقادیر مجاز و مشخصات الکتریکی
| عملکرد | Galvanically isolated single-channel IGBT gate driver |
| Isolation Technology | Coreless transformer (CT) |
| Isolation Voltage (Vrms) | 4500 Vrms |
| Output Current (Source/Sink) | 2 A (rail-to-rail) |
| Number of Channels | 1 |
| Configuration | Single low-side / high-side driver |
| بستهبندی | PG-DSO-20 |
| نوع نصب | Surface Mount |
| محدوده دمای کاری | -40 C to +125 C |
| Automotive Qualification | AEC-Q100 qualified |
| وضعیت RoHS | Compliant |
| Insulation Type | Basic insulation per DIN EN 60747-5-2 |
| Driver Type | IGBT / SiC / GaN compatible |
پیکربندی پین 1ED020I12FA2XUMA2
| پین 1 | VCC1 — Primary-side supply voltage (3.3 V or 5 V logic) |
| پین 2 | GND1 — Primary-side ground |
| پین 3 | IN+ — Non-inverting logic input |
| پین 4 | IN- — Inverting logic input |
| پین 5 | RESET — Fault reset input (active low) |
| پین 6 | RDY — Ready output (open drain) |
| پین 7 | FLT — Fault output (open drain) |
| پین 8 | NC — Not connected (per datasheet) |
| پین 9 | GND2 — Secondary-side ground (output stage return) |
| پین 10 | VCC2 — Secondary-side supply voltage (15 V / 18 V gate drive) |
| پین 11 | OUT — Gate driver output to IGBT/SiC gate |
| پین 12 | CLAMP — Active Miller clamp output |
| پین 13 | DESAT — Desaturation protection sense input |
| پین 14 | NC — Not connected (per datasheet) |
| پین 15 | NC — Not connected (per datasheet) |
| پین 16 | NC — Not connected (per datasheet) |
| پین 17 | NC — Not connected (per datasheet) |
| پین 18 | NC — Not connected (per datasheet) |
| پین 19 | NC — Not connected (per datasheet) |
| پین 20 | EP — Exposed pad (thermal pad, solder to ground pour) |
کاربردهای معمول
1ED020I12FA2XUMA2 مناسب است برای 6 کاربردs: EV Traction Inverter, Onboard EV Charger (OBC), Industrial Servo Drive, Solar String Inverter, Uninterruptible Power Supply (UPS), Industrial Welding Equipment.
EV Traction Inverter
The 1ED020I12FA2XUMA2 fits EV traction inverter gate-drive requirements because its 4500 Vrms coreless-transformer isolation provides reinforced insulation per IEC 60664, while the 2 A source/sink output stage directly drives 750 V/1200 V IGBT or SiC inverter modules. AEC-Q100 qualification supports automotive production. The high CMTI rejects common-mode transients from SiC switching edges above 50 V/ns, preventing false DESAT triggers during normal operation.
پیشنهادی
Onboard EV Charger (OBC)
The 1ED020I12FA2XUMA2 drives the primary-side IGBTs or SiC MOSFETs in a 6.6 kW or 11 kW onboard EV charger. Its 2 A peak output handles the gate-charge demand of TO-247 packaged power devices without external boosters, while the integrated DESAT protection provides fast short-circuit detection required by automotive safety standards (ISO 26262). The compact PG-DSO-20 package simplifies thermal management in the densely populated OBC PCB.
پیشنهادی
Industrial Servo Drive
For industrial servo drives, the 1ED020I12FA2XUMA2 provides the reinforced isolation and 2 A drive current needed to switch 600 V/1200 V IGBT modules in three-phase inverter stages. Its wide operating temperature range (-40 C to +125 C) supports cabinet-mounted factory automation equipment. The integrated Miller clamp prevents parasitic turn-on in half-bridge configurations during fast switching transients, improving system reliability.
پیشنهادی
Solar String Inverter
The 1ED020I12FA2XUMA2 is well matched to solar string inverter boost and H-bridge stages where 1200 V IGBTs or SiC MOSFETs switch at 16-50 kHz. The 2 A rail-to-rail output drives large modules directly, reducing BOM by eliminating discrete buffer circuits. Galvanic isolation simplifies ground-loop management across the photovoltaic array, while UVLO on both primary and secondary sides prevents partial-drive operation that would otherwise cause excessive switching losses.
پیشنهادی
Uninterruptible Power Supply (UPS)
In online UPS systems, the 1ED020I12FA2XUMA2 drives the IGBT inverter stage that converts DC battery voltage to AC mains. The 4500 Vrms isolation barrier simplifies PCB layout by allowing control and power grounds to remain isolated, while DESAT protection prevents catastrophic failures during output short-circuit events. The 2 A drive current supports IGBT modules up to 600 A in commercial three-phase UPS systems.
پیشنهادی
Industrial Welding Equipment
Welding power supplies benefit from the 1ED020I12FA2XUMA2's robust 2 A gate-drive capability and high CMTI, which tolerates the harsh dv/dt environment of inverter welders operating at 20-100 kHz. The integrated DESAT detection provides critical short-circuit protection for the IGBTs in the secondary rectifier stage. The AEC-Q100 automotive qualification gives designers confidence for harsh industrial environments with elevated ambient temperatures and vibration.
پیشنهادی
خلاصه محصولات پیشنهادی
دادههای مرجع مهندسی برای 1ED020I12FA2XUMA2 — مقایسه، راهنمای طراحی و اطلاعات انطباق.
راهنمای انتخاب
مقایسه با جایگزینها
| پارامتر | این محصول | 1ED020I12FAXUMA2 | 1ED020I12B2XUMA1 | 1ED020I12FA |
|---|---|---|---|---|
| Brand | Infineon Technologies | Infineon Technologies | Infineon Technologies | Infineon Technologies |
| Package | PG-DSO-20 | PG-DSO-20 (same) | PG-DSO-20 (same) | PG-DSO-20 (same) |
| Output Current (Source/Sink) | 2 A | 2 A | 2 A | 2 A |
| Isolation Technology | Coreless Transformer (CT) | Coreless Transformer (CT) | Coreless Transformer (CT) | Coreless Transformer (CT) |
| Automotive Qualification | AEC-Q100 | AEC-Q100 | AEC-Q100 | AEC-Q100 |
| Channels | 1 | 1 | 1 | 1 |
| Datasheet Revision | Rev 2 (FA2 suffix) | Rev 1 (FA suffix) | B2 variant | Rev 1 (base MPN) |
تفاوتهای کلیدی
- Coreless transformer (CT) isolation eliminates optocoupler CTR degradation (در مقابلTraditional optocoupler-based gate drivers (e.g., HCPL-3120))
- AEC-Q100 automotive qualification with high CMTI (در مقابلIndustrial-grade isolated gate drivers)
- Integrated 2 A output stage eliminates external booster (در مقابل1 A isolated drivers requiring external booster transistors)
یادداشتهای طراحی
The PG-DSO-20 package dissipates heat primarily through the exposed pad (EP). For continuous 2 A gate-drive operation at 100 kHz switching frequency with a 100 nC gate charge, the driver dissipates approximately 0.5 W internally. Solder the EP to a copper pour of at least 100 mm^2 on the top and bottom layers with thermal vias (9-12 vias of 0.3 mm diameter) to keep junction temperature rise below 30 C above ambient. Without adequate EP soldering, the device may trigger thermal shutdown at high ambient temperatures.
Place the DESAT blanking capacitor (typically 100 pF) and the DESAT diode (high-voltage fast-recovery, e.g., 1N4148 or BAS21) as close to the DESAT pin as possible to minimize parasitic inductance. The DESAT sensing path must not share copper with the gate-drive loop; route it on the opposite side of the board or use an inner layer. Keep the OUT trace short and wide (at least 0.5 mm) to minimize gate-loop inductance, which directly impacts switching losses and ringing.
Do not exceed VCC2 absolute maximum rating (typically 25 V). Use a TVS diode or Zener clamp on VCC2 if the bootstrap supply has inductive ringing. The DESAT threshold voltage is typically 9 V - verify your IGBT's saturation voltage at maximum load current does not exceed this threshold during normal operation, otherwise the protection circuit may false-trigger. Add a small RC filter (100 ohm + 100 pF) on DESAT for noise immunity in high-dv/dt environments.
Route the primary-side (VCC1, GND1, IN+, IN-) and secondary-side (VCC2, GND2, OUT, DESAT, CLAMP) signals on separate PCB layers with the isolation barrier in between. Maintain at least 8 mm creepage and clearance distance for reinforced insulation per IEC 60747-5-2 at 1200 V working voltage. Avoid routing any signal traces beneath the device body that would cross the isolation barrier - this degrades isolation voltage and may fail safety certification testing.
اطلاعات انطباق
AEC-Q100 qualified per Infineon product page. Basic insulation per DIN EN 60747-5-2. RoHS and REACH compliant per manufacturer datasheet.