AD783JR - 250 ns High-Speed Sample-and-Hold | Analog Devices
MPN: AD783JR ✗ پایان تولیدAD783JR نمای کلی
A sample-and-hold amplifier is an analog sampling device that briefly acquires an input signal and then stores its voltage for a longer interval. The sample-and-hold category sits within analog signal-chain ICs and supports high-speed ADC front ends, instrumentation, oscilloscope acquisition circuits, and precision test equipment. By placing an ADC behind a sample-and-hold stage, the system can reduce acquisition-time requirements on the converter while preserving the sampled voltage during conversion.
The AD783's key acquisition characteristic is its typical 250 ns settling time to within 0.01%. The manufacturer also specifies the device for hold-mode total harmonic distortion testing with input frequencies up to 100 kHz. Its specified hold droop rate is 0.02 uV/us, which limits the rate at which the stored output changes during hold mode. These characteristics make the device useful where the sampling aperture and the accuracy of the held voltage both influence overall measurement quality.
The AD783 is a monolithic analog device rather than a switched-capacitor implementation. This architecture allows direct use in precision instrumentation and high-speed sampling systems, but it also requires correct control of the sample-and-hold timing and external hold capacitor. The analog input, reference, control, ground, and supply connections must be routed in accordance with the manufacturer pin-description table to minimize switching transients and acquisition error.
Typical applications include high-speed 12-bit and 14-bit analog-to-digital converter front ends, digital oscilloscope input channels, phase-sensitive measurement systems, and laboratory instrumentation. The manufacturer specifically identifies the AD783 as suitable for 12-bit and 14-bit ADC applications because its acquisition and hold behavior can reduce the effective demand placed on the converter during the sampling interval.
The principal design tradeoff is droop versus hold capacitance. A larger hold capacitor reduces droop in absolute microvolts per microsecond but generally requires more charge for rapid acquisition. Designers should therefore select the capacitor value, control timing, and input impedance together, and verify settling and acquisition performance in the complete analog layout.
This product analysis combines the manufacturer's device information, exact-MPN package identification, operating characteristics, pricing reference, and carefully qualified replacement considerations. It also highlights practical acquisition, droop, thermal, and layout issues engineers must address before using the AD783JR as a drop-in part in new or legacy equipment.
جایگزینهای drop-in برای AD783JR — همان پکیج، سازگار پینبهپین. قطعات با پکیج متفاوت که نیاز به تغییر PCB دارند مستثنی هستند.
هیچ جایگزین مستقیمی برای این محصول موجود نیست.
درخواست جایگزینAD783JR حداکثر مقادیر مجاز و مشخصات الکتریکی
| Product Type | Monolithic sample-and-hold amplifier |
| Channel Count | 1 circuit |
| Typical Acquisition Time | 250 ns to 0.01% |
| Hold-Mode Test Input Frequency | Up to 100 kHz |
| Hold Droop Rate | 0.02 uV/us |
| بستهبندی | 8-pin SOIC |
| نوع نصب | Surface mount |
| J-Grade Availability | 8-pin cerdip and SOIC packages |
| Military Temperature Version Package | 8-pin cerdip package |
| Military Temperature Version Range | -55 C to +125 C |
راهنمای پیکربندی پین AD783JR 8-pin cerdip package
پیکربندی پین برای AD783JR (پکیج 8-pin cerdip package). این قطعه آنالوگ دارای پینهای ورودی، خروجی و تغذیه است. برای پیکربندیهای پین offset null، جبرانسازی و فعالسازی به دیتاشیت سازنده مراجعه کنید. ایدهآل برای مدارهای شرطیسازی سیگنال و تقویتکننده.
داده پینآوت تفصیلی موجود نیست برای AD783JR.
به دیتاشیت برای پیکربندی کامل پینها.
کاربردهای معمول
AD783JR مناسب است برای 6 کاربردs: High-Speed ADC Front Ends, Digital Oscilloscope Acquisition, Precision Instrumentation, Phase-Sensitive Measurement, Legacy Data-Acquisition Systems, Test and Measurement Signal Capture.
High-Speed ADC Front Ends
The AD783JR is suited to the input stage of a 12-bit or 14-bit ADC because its typical acquisition time of 250 ns to 0.01% provides a defined interval for capturing the analog voltage. Placing it ahead of the converter can isolate the ADC input from changes during the conversion period. The design must coordinate the sample command, hold-capacitor value, source impedance, and ADC clock so that acquisition completes before the converter samples the stored value.
پیشنهادی
Digital Oscilloscope Acquisition
The AD783JR can form the acquisition element of an oscilloscope input channel when the required settling interval is compatible with its 250 ns typical acquisition to 0.01%. The hold-mode droop of 0.02 uV/us must be checked against the full digitization interval because it can create a time-dependent measurement error. Input attenuation, protection, bandwidth, and channel isolation remain separate design tasks, while the sample-and-hold timing must be deterministic and repeatable.
پیشنهادی
Precision Instrumentation
In laboratory and industrial instrumentation, the AD783JR provides a dedicated analog hold function between a signal source and a downstream measurement device. Its 250 ns typical acquisition to 0.01% supports systems that need to capture a defined sample rather than follow a continuously changing input. Analog Devices also identifies testing up to 100 kHz in hold mode, making the device relevant to instrumentation requiring characterized dynamic hold-mode behavior.
پیشنهادی
Phase-Sensitive Measurement
The AD783JR can be used when a measurement cycle requires a stable analog value during a later comparison, conversion, or control interval. Its 250 ns acquisition time allows the circuit to settle to within 0.01% under suitable source and hold-capacitor conditions, while the 0.02 uV/us droop defines the expected drift during hold mode. Trigger timing should be arranged so acquisition, hold, and measurement intervals do not overlap unintentionally.
پیشنهادی
Legacy Data-Acquisition Systems
The AD783JR is especially relevant when repairing or replicating a legacy data-acquisition system whose original schematic relies on an AD783-family sample-and-hold amplifier. Retaining the established part can preserve the intended acquisition timing and analog behavior without redesigning the board. Before substitution, compare every SOIC-8 connection, the hold-capacitor value, control polarity, supply arrangement, and acquisition requirements across the full input range.
پیشنهادی
Test and Measurement Signal Capture
The AD783JR can capture a rapidly changing input for subsequent processing in a test system where acquisition must reach 0.01% before the measurement proceeds. Its characterized hold droop of 0.02 uV/us allows the system designer to relate stored-value error to the selected hold duration. Practical implementation requires controlled trigger delay, adequate source drive, carefully placed hold capacitance, and verification of distortion with the intended input frequency and signal amplitude.
پیشنهادی
دادههای مرجع مهندسی برای AD783JR — مقایسه، راهنمای طراحی و اطلاعات انطباق.
راهنمای انتخاب
یادداشتهای طراحی
Do not treat the nominal 250 ns acquisition time as a complete timing specification. Account for the delay of the sample-control signal, source impedance, hold-capacitor charging, comparator or ADC aperture time, and clock-to-control propagation delay. Confirm the circuit reaches the required accuracy at the lowest expected input amplitude and fastest intended acquisition command.
Keep the input, hold-capacitor, and output paths short and place associated high-frequency bypass components close to their pins. Provide a low-impedance return for the reference and supply returns, and avoid routing digital control traces adjacent to sensitive analog nodes. The sample-command transition can inject disturbance into the held charge, so its timing relative to conversion must be reviewed.
Decouple the supply with capacitors selected according to the manufacturer recommendations and place them immediately across the relevant pins. Estimated design checks should use the actual supply voltage, load current, source impedance, and measured switching activity rather than assuming ideal behavior. Verify startup, settling, and temperature performance because a quick acquisition requirement can increase demand on the supply and reference network.
اطلاعات انطباق
No authoritative RoHS, REACH, AEC-Q100, lead-free, halogen-free, or conflict-minerals status was identified for the exact AD783JR MPN.