INA146UAG4 - High-Voltage Programmable Gain Difference Amplifier | Texas Instruments
MPN: INA146UAG4 ✓ فعالINA146UAG4 نمای کلی
A difference amplifier is an amplifier topology that responds to the voltage difference between its differential inputs while rejecting signals common to both inputs. This common-mode rejection improves signal integrity in industrial measurement, sensor-interface, and high-voltage feedback systems. The INA146 belongs to the instrumentation-amplifier and operational-amplifier hierarchy, where precision gain control, low distortion, and accurate differential sensing are primary design considerations.
Key features include programmable gain, high-voltage input handling, a differential input configuration, and operation from a single supply or dual-supply arrangement. The 550 kHz bandwidth supports applications requiring accurate signal amplification without the bandwidth limits of much slower precision instrumentation amplifiers. The INA146UAG4 is identified in distributor listings as a one-circuit differential amplifier in an 8-SOIC package.
The device is used in applications including high-voltage sensor measurement, current-shunt monitoring, industrial process control, data-acquisition systems, and precision analog signal conditioning. Its differential architecture helps reduce errors caused by common-mode noise and ground-potential differences when the measured signal is referenced to a noisy or elevated source.
When designing a circuit around the INA146UAG4, verify the absolute maximum differential and common-mode input voltages, supply limits, gain-resistor network, output swing, and stability requirements in the manufacturer datasheet. Place the gain-setting network and input components close to the device, and use careful routing to minimize parasitic capacitance and noise pickup around the high-impedance amplifier inputs.
جایگزینهای drop-in برای INA146UAG4 — همان پکیج، سازگار پینبهپین. قطعات با پکیج متفاوت که نیاز به تغییر PCB دارند مستثنی هستند.
گونهها در این سری
مدلهای همسری که جایگزین مستقیم هستند برای INA146UAG4 (همان فرمفاکتور و فوتپرینت) — متفاوت در Package, Product Type, Gain Configuration, Input Protection.
INA146UA
✅ جایگزین مستقیمبرای قیمت تماس بگیرید
مشاهده دیتاشیت ←INA148UA
✅ جایگزین مستقیمبرای قیمت تماس بگیرید
مشاهده دیتاشیت ←INA146UAG4 حداکثر مقادیر مجاز و مشخصات الکتریکی
| Product Type | High-Voltage Programmable Gain Difference Amplifier |
| Amplifier Type | Differential amplifier |
| Number of Circuits | 1 circuit |
| Gain-Bandwidth Product | 550 kHz |
| بستهبندی | 8-SOIC, 0.154 inch body width, 3.90 mm width |
| Supply Type | Single or dual supply; exact limits not stated in the verified listings |
| Input Type | Differential input |
| Common-Mode Range | Extends beyond both supply rails |
| Input Protection | High-voltage capability provides inherent input protection |
| نوع خروجی | Single-ended output |
| Gain Configuration | Programmable gain using an external gain-setting resistor |
| Operating Frequency | 550 kHz gain-bandwidth product |
پیکربندی پین INA146UAG4
| پین 1 | RG — Gain-setting resistor connection |
| پین 2 | IN- — Inverting differential input |
| پین 3 | IN+ — Non-inverting differential input |
| پین 4 | VS- — Negative supply connection |
| پین 5 | REF — Reference connection for output and gain configuration |
| پین 6 | OUT — Single-ended amplifier output |
| پین 7 | VS+ — Positive supply connection |
| پین 8 | RG — Gain-setting resistor connection |
کاربردهای معمول
INA146UAG4 مناسب است برای 6 کاربردs: High-Voltage Sensor Interface, Shunt-Based Current Measurement, Industrial Process Control, Data-Acquisition Front End, Bridge and Transducer Measurement, Power and Motor Feedback Monitoring.
High-Voltage Sensor Interface
The INA146UAG4 suits sensor front ends that produce a differential signal riding on a substantial common-mode voltage. Its difference-amplifier architecture rejects common-mode error, while the input common-mode range extending beyond both supply rails allows the input stage to operate with elevated signal levels. Place the amplifier close to the sensor leads, use a differential return path, and verify the maximum differential input voltage against the sensor transients. Program the gain with the resistor network specified in the INA146 datasheet and add filtering where sensor noise dominates.
پیشنهادی
Shunt-Based Current Measurement
The INA146UAG4 can amplify the small differential voltage produced by a current shunt while rejecting the common-mode voltage present on the shunt terminals. The 550 kHz gain-bandwidth product provides useful bandwidth for many industrial and control loops, and the high-voltage capability reduces the need for aggressive input attenuation. Place the shunt close to the amplifier input pins, use paired routing for the differential pair, and check Kelvin connections so trace resistance does not create an offset error.
پیشنهادی
Industrial Process Control
In process-control systems, the INA146UAG4 is useful for conditioning a differential measurement from pressure, temperature, or current transducers. The device combines programmable gain with common-mode rejection, helping preserve the small signal of interest when the transducer is referenced to an elevated or noisy ground. Choose the external gain network and input filtering together, because the bandwidth and phase margin of the complete measurement chain determine loop stability. Verify supply headroom and output swing against the downstream controller input.
پیشنهادی
Data-Acquisition Front End
The INA146UAG4 can serve as the first analog stage of a data-acquisition front end when the source is differential and the common-mode level is high. Its programmable-gain architecture allows the same analog section to cover multiple measurement ranges, while the 550 kHz bandwidth supports moderate-rate acquisition rather than only static instrumentation. Keep the differential pair short and matched, reference the shield or guard structure to the measurement return, and confirm that the programmed gain leaves sufficient bandwidth for the sampling rate.
پیشنهادی
Bridge and Transducer Measurement
The INA146UAG4 is appropriate for bridge or resistive-transducer measurements where the useful output is differential and the bridge excitation creates a substantial common-mode level. Programmable gain allows the amplifier to scale the bridge output while the difference-amplifier function suppresses excitation-related common-mode voltage. Use the manufacturer-specified gain resistor and reference arrangement, and evaluate offset and drift at the intended gain rather than assuming the highest programmable gain is best. Thermal gradients across the bridge and input board can dominate the final accuracy.
پیشنهادی
Power and Motor Feedback Monitoring
The INA146UAG4 can monitor feedback signals in power-conversion and motor-control systems where a small differential voltage appears across a shunt or sense element. Its common-mode handling and differential topology help preserve measurement accuracy in electrically noisy environments, and the 550 kHz bandwidth supports faster feedback loops than a slow precision-only amplifier. Keep the sense-path components close to the device, avoid sharing return traces with switching current, and validate the amplifier against the switching node’s full transient amplitude.
پیشنهادی
خلاصه محصولات پیشنهادی
دادههای مرجع مهندسی برای INA146UAG4 — مقایسه، راهنمای طراحی و اطلاعات انطباق.
راهنمای انتخاب
مقایسه با جایگزینها
| پارامتر | این محصول | INA146UA | INA148UA |
|---|---|---|---|
| Brand | Texas Instruments | Texas Instruments | Texas Instruments |
| Package | 8-SOIC | 8-SOIC | 8-SOIC |
| Amplifier Type | Differential amplifier | High-voltage programmable-gain difference amplifier | High-voltage difference amplifier |
تفاوتهای کلیدی
- Differential high-voltage measurement with programmable gain (در مقابلINA146UA)
- Input common-mode range extends beyond the supply rails (در مقابلINA148UA)
- Eight-pin SOIC implementation with single-ended output (در مقابلINA146UA)
یادداشتهای طراحی
Route IN+ and IN- as a tightly matched differential pair, keep the pair short, and connect the two input returns to the same measurement reference. Place the gain-setting resistor close to the RG pins and keep the REF connection short and quiet. Traces that run alongside switching nodes or high-current power paths can degrade common-mode rejection and create errors that are difficult to distinguish from amplifier offset.
Do not treat the extended input common-mode range as permission to exceed the absolute maximum differential input rating. Check transient voltage during connector insertion, inductive load switching, and sensor faults. Series input resistance can limit fault current, but it also interacts with amplifier input capacitance; select protection components that preserve the intended bandwidth and do not introduce excessive leakage.
Use the resistor values and gain configuration shown in the manufacturer datasheet, and calculate the closed-loop bandwidth at the selected gain rather than assuming the full 550 kHz gain-bandwidth product is available at every gain setting. Add filtering at the input when needed, but place capacitors symmetrically or otherwise account for their tolerance so differential signals remain balanced.
Estimate amplifier dissipation from the actual supply voltage, output voltage, and output current, then add that dissipation to the junction-temperature calculation. The verified listings do not provide a complete thermal-resistance value for this exact orderable, so use the package thermal data in the Texas Instruments datasheet and the final PCB copper area. Do not use the distributor package description as a substitute for thermal specifications.
اطلاعات انطباق
The verified listings identify the INA146UAG4 as a Texas Instruments 8-SOIC differential amplifier but do not provide the detailed RoHS, REACH, halogen-free, lead-free, or conflict-minerals declarations. Confirm the orderable’s compliance documents with the manufacturer.