AD549LHZ Présentation

The Analog Devices AD549LHZ is a single-circuit electrometer operational amplifier with very low input bias current, laser-trimmed input offset voltage, and laser-trimmed offset-voltage drift. It is available in an 8-pin TO-99-8 metal-can package and operates at a 1 MHz gain-bandwidth product. The AD549LHZ is designed for precision signal chains in which the current drawn by the input stage can otherwise create unacceptable measurement errors.

An electrometer operational amplifier is a specialized type of operational amplifier optimized for exceptionally low input bias current. Within the signal-chain hierarchy, it provides the gain and input buffering required by high-impedance sensors, charge-measurement circuits, photodetectors, and laboratory instrumentation. Unlike a general-purpose operational amplifier, an electrometer amplifier minimizes current entering its input terminals so that source impedance and leakage effects remain small relative to the measured signal.

The AD549 family combines low input current with precision DC characteristics. Analog Devices identifies Topgate JFET technology as the process responsible for the ultralow input current, while laser trimming of input offset voltage and offset-voltage drift improves precision at the factory level. The result is an amplifier suited to applications where current leakage, offset error, or temperature-dependent drift can obscure a small sensor signal. The LHZ ordering code identifies the 8-pin TO-99 package configuration.

At the circuit level, the AD549LHZ operates as a conventional precision operational amplifier with feedback-defined gain. Its low input current is especially important when the source is a photodiode, ionization chamber, electrochemical sensor, or other high-impedance transducer. The 1 MHz gain-bandwidth product permits useful signal bandwidth, although noise, input capacitance, stability, and output-drive conditions still determine the practical operating bandwidth. Bypass capacitors and careful guarding around sensitive input nodes are therefore more important than treating the wide bandwidth as a reason to omit layout discipline.

Typical uses include pH and ion-selective measurement, photovoltaic and radiation-detection instrumentation, charge-sensitive preamplifiers, low-current sensors, laboratory amplifiers, and precision bridge front ends. In these systems, the amplifier converts a weak current or high-impedance voltage into a usable analog signal while introducing less input-current error than a conventional amplifier. The metal-can package also supports applications where through-hole assembly and a stable industrial component format are preferred.

Designers should evaluate leakage, guarding, connector cleanliness, board contamination, and the bias current flowing through feedback resistors. A practical rule is to keep the highest-impedance node physically small, avoid exposed conductors near the inputs, and route guard structures where appropriate. The amplifier, its resistor network, and the sensor interface should also be checked for temperature gradients because those factors can dominate the final measurement uncertainty.

This page combines the AD549 architecture, package information, replacement analysis, and application guidance into an engineering-focused selection resource. It highlights where the AD549LHZ is appropriate, which same-package alternatives may fit different precision or qualification requirements, and which layout and sourcing details should be confirmed before production release.

Alternatives de remplacement direct pour AD549LHZ — même boîtier, compatible broche à broche. Les références à boîtier différent nécessitant une retouche du PCB sont exclues.

Variantes de cette série

Modèles de la même série directement compatibles avec AD549LHZ (même facteur de forme et même empreinte) — différant par Package Type, Slew Rate, Amplifier Type, Mounting Type, Number of Channels.

Analog Devices
Amplifier Type: Operational Amplifier
Mounting Type: Through-hole wire lead
Comparer avec AD549LHZ →
Analog Devices
Package Type: TO-99-8 hermetic
Slew Rate: 3 V/us
Number of Channels: 1 channel
Comparer avec AD549LHZ →
Analog Devices
Package Type: TO-99-8 hermetic package
Slew Rate: 3 V/μs
Number of Channels: 1 channel
Comparer avec AD549LHZ →
Analog Devices
Package Type: TO-99 hermetic, 8 pins
Slew Rate: 3 V/µs
Number of Channels: 1 amplifier
Comparer avec AD549LHZ →
Analog Devices
Mounting Type: Through-hole
Comparer avec AD549LHZ →

AD549JHZ

✅ Remplacement direct
Analog Devices
📦 TO-99-8
Electrometer operational amplifier · 1 channel · 250 fA for AD549J grade · 1.00 mV for AD549J grade · 15 μV/°C · 1 MHz · 3 V/μs · ±5 V to ±18 V

Contactez-nous pour le prix

Voir la fiche technique →

AD549JH

✅ Remplacement direct
Analog Devices
📦 TO-99-8
Electrometer operational amplifier · 1 channel · 0.15 pA · 1 mV · 1 MHz · 3 V/us · Topgate JFET · Laser trimmed

Contactez-nous pour le prix

Voir la fiche technique →

AD549SH/883B

✅ Remplacement direct
📦 TO-99-8
Same AD549 package and architecture; qualification and ordering-code requirements differ from standard AD549LHZ.

📋 Alternative de référence (hors catalogue)

OPA128KM

✅ Remplacement direct
📦 TO-99-8
Same package and low-input-current application class; manufacturer-specific bias current, offset, drift, supply, and qualification limits differ.

📋 Alternative de référence (hors catalogue)

AD549LHZ Valeurs maximales et caractéristiques électriques

Product Type Single-circuit electrometer operational amplifier
Input Device Technology Topgate JFET
Gain-Bandwidth Product 1 MHz
Number of Circuits 1 circuit
Amplifier Type Electrometer operational amplifier
Boîtier TO-99-8 metal can
Nombre de broches 8 pins
Type de montage Through-hole

Configuration des broches de AD549LHZ

Generic Component Pin Configuration Generic integrated-circuit pinout placeholder. Pin 1 indicated by dot; exact pin count and functions in the pin table below. 1 N 2 N-1 3 N-2 4 N-3 Pin Configuration See pin table below for pin functions Package-specific diagram not available
Broche 1 NC — Not connected
Broche 2 IN- — Inverting input
Broche 3 IN+ — Non-inverting input
Broche 4 V- — Negative supply
Broche 5 NC — Not connected
Broche 6 OUT — Output
Broche 7 V+ — Positive supply
Broche 8 NC — Not connected

Applications typiques

AD549LHZ convient pour 6 applications: Photodiode Signal Conditioning, pH and Ion-Selective Measurement, Ionization Chamber Readout, Electrochemical Sensor Interface, Low-Current Charge Amplifier, Precision Laboratory Instrumentation.

📷

Photodiode Signal Conditioning

The AD549LHZ is appropriate for converting photodiode current into a voltage because its very low input bias current reduces the error introduced at the high-impedance input. It can be configured with a feedback resistor and optional capacitor to provide useful conversion gain and bandwidth. The 1 MHz gain-bandwidth product provides bandwidth for many optical-sensing systems, although the exact response depends on photodiode capacitance and feedback impedance. Keep the input trace short, protect it from contamination, and use guarding where leakage could affect the measurement.

🧪

pH and Ion-Selective Measurement

The AD549LHZ suits pH and ion-selective sensor interfaces because chemical electrodes present extremely high source impedance, where input bias current can create a substantial error voltage. Its laser-trimmed offset characteristics support precision measurement, while the Topgate JFET input stage minimizes current drawn from the sensing electrode. The amplifier should be positioned near the sensor connector, with short input traces, clean insulation, and guarded interconnects. Supply decoupling and grounding must be designed to avoid adding noise directly to the high-impedance measurement node.

🛡️

Ionization Chamber Readout

The AD549LHZ can serve as the first active element in an ionization-chamber or radiation-detector readout because very low input current preserves the small charge signal generated by the detector. Its 1 MHz gain-bandwidth product is sufficient for many charge-sensitive front ends when combined with an appropriate feedback network, but stray capacitance and feedback-resistor noise set practical sensitivity. The TO-99-8 metal can supports through-hole assembly in laboratory and industrial instruments. Guard the input and use low-leakage insulation around connectors and nearby surfaces.

⚗️

Electrochemical Sensor Interface

The AD549LHZ is well matched to electrochemical sensors whose output may be represented as a very small current. Its low input bias current limits the error introduced by high-impedance transducers, while laser trimming improves the amplifier’s DC precision. In a typical transimpedance arrangement, the feedback resistor establishes current-to-voltage conversion and the amplifier supplies a buffered output for an ADC or controller. Select resistor values with both Johnson noise and leakage in mind, and avoid placing moisture, flux residue, or conductive contamination near the input node.

⚡

Low-Current Charge Amplifier

The AD549LHZ can be used in charge-sensitive and capacitive-sensor front ends where the input current is intentionally very small. The amplifier’s electrometer-grade input stage reduces the current drawn from the sensitive node, while its 1 MHz gain-bandwidth product allows the closed-loop response to be tailored with feedback components. Practical performance remains sensitive to input capacitance, feedback capacitor selection, board leakage, and the stability of the chosen noise gain. Use a short, guarded input route and avoid excessive bandwidth when it would amplify unwanted noise.

🔬

Precision Laboratory Instrumentation

The AD549LHZ is appropriate for precision laboratory instruments that measure high-impedance sources, leakage currents, or small sensor voltages. Its laser-trimmed input offset voltage and offset-voltage drift support repeatable bench measurements, while the TO-99-8 package offers a familiar through-hole mechanical format for custom analog boards. A practical implementation should isolate sensitive input wiring from power converters and motors, maintain stable grounding, and include provisions for input biasing or guarding. Confirm supply limits and electrical characteristics in the manufacturer datasheet before selecting operating points.

Récapitulatif des produits recommandés

AD549JHZ Analog Devices Utilisé dans : Photodiode Signal Conditioning, Ionization Chamber Readout, Low-Current Charge Amplifier, Precision Laboratory Instrumentation OPA128KM Same-package low-input-current amplifier alternative Utilisé dans : Photodiode Signal Conditioning, Electrochemical Sensor Interface, Precision Laboratory Instrumentation AD549JH Analog Devices Utilisé dans : pH and Ion-Selective Measurement, Electrochemical Sensor Interface AD549SH/883B Same-family ordering option for qualified designs Utilisé dans : pH and Ion-Selective Measurement, Ionization Chamber Readout, Low-Current Charge Amplifier
What is the AD549LHZ?
The AD549LHZ is a single-circuit electrometer operational amplifier from Analog Devices, optimized for very low input bias current and precision DC operation. It uses Topgate JFET technology and has a 1 MHz gain-bandwidth product. The device is packaged in an 8-pin TO-99-8 metal can for through-hole instrumentation applications.
What applications are suitable for the AD549LHZ?
The AD549LHZ is suitable for high-impedance sensor interfaces, photodetector amplifiers, ionization chambers, electrochemical sensors, charge-sensitive preamplifiers, and laboratory instrumentation. Its very low input bias current reduces the error created when source or feedback resistance draws current from the input node. According to the Analog Devices AD549 datasheet, its input stage is designed specifically for precision current measurements.
Where can I download the AD549LHZ datasheet PDF?
The official AD549LHZ datasheet PDF is available from Analog Devices at https://www.analog.com/media/en/technical-documentation/data-sheets/AD549.pdf. The manufacturer document describes the electrometer operational amplifier, Topgate JFET input stage, electrical characteristics, pin configuration, and typical application information. Use this document to confirm operating limits before final circuit design.
What is the AD549LHZ pinout?
The AD549LHZ uses an 8-pin TO-99-8 metal-can pinout, with the conventional operational-amplifier connections for two inputs, output, positive supply, negative supply, and unused positions. Use the pin-description table and package drawing in the Analog Devices AD549 datasheet when assigning PCB tracks. Keep sensitive input and null terminals short and guard against leakage where applicable.
How does the AD549LHZ differ from AD549JHZ?
The AD549LHZ and AD549JHZ share the same electrometer amplifier architecture, TO-99-8 package, and pinout, but the LHZ offers tighter input offset-voltage and offset-voltage-drift specifications. The AD549LHZ is therefore preferable when the design prioritizes the highest DC precision. Confirm operating-temperature and ordering-code requirements against the Analog Devices datasheet.
What can replace the AD549LHZ?
The AD549JHZ is the closest same-package replacement for the AD549LHZ because it retains the electrometer architecture and TO-99-8 pinout while relaxing offset-voltage and drift limits. AD549JH, AD549SH/883B, and OPA128KM are also same-package candidates identified in cross-reference results, but their temperature grade, qualification, trim level, and exact specifications require individual verification before substitution.
Is AD549LHZ the same as OPA128KM?
The AD549LHZ and OPA128KM are not identical devices, although both are low-input-current precision operational amplifiers associated with the 8-pin TO-99 package class. The AD549LHZ uses Analog Devices Topgate JFET technology, while OPA128KM is a different manufacturer’s product with its own electrical limits, temperature grades, and qualification status. Verify pin functions, supply range, bias current, offset, drift, and stability before substitution.
When should I choose AD549LHZ over AD549JHZ?
Choose the AD549LHZ when input offset voltage and its temperature drift are more important than the looser limits of the AD549JHZ. Both use the same TO-99-8 package and pinout, so the decision is primarily a precision choice rather than a footprint choice. If the application can tolerate less tight trimming, the AD549JHZ may be adequate after its complete limits are checked against the error budget.
Is AD549LHZ suitable for photodiode and pH sensor interfaces?
The AD549LHZ is well suited to photodiode and pH-sensor interfaces because its very low input bias current limits the error introduced by high source impedances. The feedback and bias resistors should still be selected to keep their Johnson noise and thermal leakage compatible with the target resolution. Shielding, guarding, clean connectors, and leakage control are essential in these high-impedance circuits.
What is the gain-bandwidth product of AD549LHZ?
The AD549LHZ has a 1 MHz gain-bandwidth product. This specification describes the relationship between closed-loop gain and bandwidth when the amplifier is operated with suitable feedback and stability conditions. Actual usable bandwidth can be lower because of source capacitance, noise, slew rate, output loading, and the requirement for stable operation with the selected noise gain.
How should I minimize input-leakage errors with AD549LHZ?
Minimize input-leakage errors by keeping the input node physically small, cleaning connectors and boards, avoiding moisture and contamination, and using guard rings where suitable. Keep the optional null connection open unless offset adjustment is required, and avoid routing high-impedance input traces next to noisy or humid surfaces. These layout measures often determine practical performance as strongly as the amplifier’s specified bias current.
Where can I buy AD549LHZ and what is its lead time?
The AD549LHZ can be requested through the “Request a Quote” form on this page for current commercial terms, stock status, and lead time. Commercial conditions can change, so request the exact AD549LHZ ordering code and package rather than relying on a generic AD549 label. The current manufacturer status and quote response should be confirmed before committing the production schedule.
Is AD549LHZ in stock?
Current stock for the exact AD549LHZ ordering code should be confirmed through the “Request a Quote” form on this page. The device is an active catalog product, but availability is a transaction-dependent attribute that can change independently of lifecycle status. Provide the required quantity, packaging preference, and target delivery date when requesting an update.
What are the key specifications of AD549LHZ that engineers should know?
The key AD549LHZ specifications are its very low input bias current, laser-trimmed input offset voltage, laser-trimmed offset-voltage drift, Topgate JFET input technology, 1 MHz gain-bandwidth product, single-circuit construction, and 8-pin TO-99-8 metal-can package. These characteristics place it in the precision electrometer-amplifier category for high-impedance measurement and low-current signal conditioning.
What is the best Analog Devices equivalent for AD549LHZ?
The best same-brand candidate identified for a drop-in review is the AD549JHZ because it shares the AD549 electrometer architecture and TO-99-8 package. Its input offset voltage and offset-voltage drift are less tightly specified than those of the AD549LHZ. Choose it when its electrical limits meet the design requirement and confirm the complete ordering code, temperature range, and lifecycle status before release.

Données de référence d'ingénierie pour AD549LHZ — comparaison, recommandations de conception et informations de conformité.

Guide de sélection

Choose the AD549LHZ for precision, high-impedance measurements where very low input bias current, tightly trimmed input offset voltage, and low offset-voltage drift are important. The AD549JHZ is the closest same-family option when the board can retain the TO-99-8 footprint but does not require the LHZ’s tighter offset specifications. AD549JH may be considered when its exact temperature grade and electrical limits satisfy the design. AD549SH/883B is relevant when the project requires its particular qualified ordering configuration. OPA128KM offers a cross-brand, same-package precision-amplifier alternative, but its bias current, offset, drift, supply range, stability, and qualification must be compared directly. In every case, verify the manufacturer datasheet, check input leakage and guarding, and confirm the complete ordering code before production release.

Comparaison avec les alternatives

Paramètre Ce produit AD549JHZ AD549JH AD549SH/883B OPA128KM
Brand Analog Devices Analog Devices Analog Devices Analog Devices Texas Instruments
Package TO-99-8 TO-99-8 - same package TO-99-8 - same package TO-99-8 - same package TO-99-8 - same package
Product Type Electrometer operational amplifier Electrometer operational amplifier Electrometer operational amplifier Electrometer operational amplifier Low-input-current precision operational amplifier
Circuit Count 1 circuit 1 circuit 1 circuit 1 circuit 1 circuit
Mounting Style Through-hole metal can Through-hole Through-hole Through-hole Through-hole

Principaux différenciateurs

  • Tighter precision trimming than AD549JHZ (vs AD549JHZ)
  • Direct AD549-family continuity (vs AD549SH/883B)
  • Established same-package precision alternative (vs OPA128KM)

Notes de conception

Route the inverting input directly to the feedback resistor and minimize the area of the high-impedance node. Keep connectors, solder mask, and board surfaces clean and dry because contamination can create leakage paths that exceed the AD549LHZ input-current capability. Where practical, surround sensitive input routing with a guard driven by the amplifier’s inverting-input potential.

Do not assume that a low input bias current makes every leakage mechanism negligible. Connector insulation, flux residue, moisture, and contaminated PCB surfaces can produce errors in high-impedance circuits. Use suitable cleaning practices, low-leakage connectors, and a protective enclosure when the measurement environment is humid or dusty. Also confirm the exact pinout and null-terminal treatment in the manufacturer datasheet.

The 1 MHz gain-bandwidth product does not guarantee 1 MHz of useful signal bandwidth in every circuit. Source capacitance, feedback impedance, closed-loop noise gain, slew rate, and output loading influence stability and response. Start with conservative noise gain, evaluate the complete sensor-and-amplifier model, and add compensation components only after confirming the required phase margin.

Informations de conformité

RoHS
Unknown
REACH
Unknown
AEC-Q100
Unknown
Sans plomb
Unknown
Sans halogène
Unknown
Minerais de conflit
Unknown

No explicit RoHS, REACH, AEC-Q100, lead-free, halogen-free, or conflict-minerals status was identified for the exact AD549LHZ ordering code.

Données vérifiées le : 2026-11-25 — données vérifiées et sélectionnées par l'équipe d'ingénierie composants de XAIPART

Recherches associées

AD549LHZ datasheet AD549LHZ datasheet pdf AD549LHZ pinout AD549LHZ specifications AD549LHZ equivalent AD549LHZ replacement AD549LHZ cross reference AD549LHZ vs AD549JHZ AD549LHZ vs OPA128KM AD549LHZ TO-99-8 AD549LHZ electrometer amplifier AD549LHZ low input bias current AD549LHZ photodiode amplifier AD549LHZ price AD549LHZ stock

Composants & termes associés

Analog Devices AD549LHZ AD549JHZ AD549JH AD549SH/883B OPA128KM Texas Instruments electrometer operational amplifier precision operational amplifier operational amplifier amplifier IC semiconductor low input bias current input offset voltage input offset voltage drift Topgate JFET JFET gain-bandwidth product TO-99-8 TO-99 metal can package through-hole package surface-mount package hierarchy RoHS REACH AEC-Q100 photodiode amplifier ionization chamber readout pH sensor interface electrochemical sensor charge-sensitive preamplifier
RFQ de devis rapide
Renseignez tous les détails — notre équipe commerciale vous répondra sous 24 heures
Référence Fabricant Boîtier QTY Prix cible Total
✓
Devis envoyé !

Nous répondrons à votre e-mail sous 24 heures

1
RFQ envoyée
2
Devis reçu
3
Commande passée
4
Paiement
5
Expédié
6
Livré
Voir les détails de la RFQ