AD977BRS - 16-Bit 100 kSPS SAR ADC | Analog Devices
Référence : AD977BRS ✓ ActifAD977BRS Présentation
An ADC is a data-conversion IC that transforms an analog voltage into a digital number for processing, storage, transmission, or control. The AD977 belongs to the successive-approximation ADC family, within the broader ADC and data-converter semiconductor hierarchy. Compared with flash and pipelined converters, a successive-approximation ADC can provide useful resolution and speed in a compact, relatively low-power design for precision acquisition systems.
The AD977BRS converts 16-bit samples at up to 100 kSPS while offering selectable input ranges and external-reference capability. Its single 5 V architecture simplifies system power planning, while the internal 2.5 V reference supports applications that do not require a separate reference source. Maximum power dissipation is 100 mW, and serial output reduces the number of signal lines required to transfer conversion results.
Internally, the converter uses a switched-capacitor successive-approximation architecture. This implementation supports a compact 28-pin SSOP package and is suited to instrumentation, industrial control, communications, and embedded data-acquisition systems. External reference and input-range selections allow designers to balance conversion accuracy, signal conditioning, and system flexibility for different analog input conditions.
Typical uses include multichannel process monitoring, transducer signal acquisition, communications-channel digitizing, industrial sensor interfaces, portable measurement equipment, and laboratory instruments. The 100 kSPS rate is especially appropriate for continuous monitoring signals that require more resolution than a low-cost comparator-based system but do not need flash-converter throughput.
Design around the 5 V supply requirement, selected input range, and 100 mW maximum power dissipation. Place bypass capacitance close to the supply pins, route analog inputs away from fast digital transitions, and use the pin-description table in the manufacturer datasheet when assigning tracks and grounding. The power-down function can reduce consumption during inactive intervals, but system timing must account for startup behavior.
This page organizes the AD977BRS specifications, package information, application guidance, and drop-in replacement considerations into one engineering reference. It also identifies the key electrical, timing, power, and selection trade-offs that matter when adapting an existing 28-SSOP data-acquisition design.
Alternatives de remplacement direct pour AD977BRS — même boîtier, compatible broche à broche. Les références à boîtier différent nécessitant une retouche du PCB sont exclues.
Variantes de cette série
Modèles de la même série directement compatibles avec AD977BRS (même facteur de forme et même empreinte) — différant par Package, Operating Temperature, Power-Down Mode, Supply Voltage.
AD977BRSZ
✅ Remplacement directContactez-nous pour le prix
Voir la fiche technique →AD977BRU
✅ Remplacement direct ⚠️ Spécifications non vérifiées📋 Alternative de référence (hors catalogue)
AD977ARU
✅ Remplacement direct ⚠️ Spécifications non vérifiées📋 Alternative de référence (hors catalogue)
AD977BRS Valeurs maximales et caractéristiques électriques
| Résolution | 16 bit |
| Conversion Throughput | 100 kSPS |
| Converter Architecture | Successive-approximation switched-capacitor ADC |
| Tension d'alimentation | 5 V |
| Number of Inputs | 1 input |
| Interface | Serial I/O |
| Unipolar Input Range 1 | 0 V to 5 V |
| Unipolar Input Range 2 | 0 V to 4 V |
| Bipolar Input Range 1 | ±5 V |
| Bipolar Input Range 2 | ±3.3 V |
| Internal Reference Voltage | 2.5 V |
| Reference Selection | Internal or external reference |
| Maximum Power Dissipation | 100 mW |
| Power-Down Current | 50 µW |
| Process Technology | BiCMOS |
| Boîtier | 28-pin SSOP |
| Type de montage | Surface mount |
Guide de configuration des broches du AD977BRS 28-pin ssop
Configuration des broches du AD977BRS (boîtier 28-pin ssop). Ce composant analogique comporte des broches d'entrée, de sortie et d'alimentation. Consultez la fiche technique du fabricant pour les configurations des broches d'annulation d'offset, de compensation et d'activation. Idéal pour le conditionnement de signaux et les circuits amplificateurs.
Aucune donnée de brochage détaillée disponible pour AD977BRS.
Consultez la fiche technique pour la configuration complète des broches.
Applications typiques
AD977BRS convient pour 6 applications: Industrial Process Monitoring, Communications Channel Digitizing, Precision Data-Acquisition Systems, Sensor Signal Conditioning, Portable Measurement Instruments, Medical and Diagnostic Instrumentation.
Industrial Process Monitoring
The AD977BRS suits process-monitoring systems that repeatedly digitize pressure, temperature, position, or level signals. Its 16-bit resolution preserves small analog changes, while the 100 kSPS rate provides more sampling capacity than slow sensor outputs generally require. Use the 0 V to 5 V or 0 V to 4 V unipolar range for conditioned sensor signals, or the ±5 V and ±3.3 V bipolar options when the front end produces centered signals. The single 5 V supply simplifies controller integration, and the 50 µW power-down mode can reduce consumption during inactive intervals. Add input filtering, surge protection, calibration, and grounding appropriate to the industrial environment.
Communications Channel Digitizing
The AD977BRS can digitize communication-channel waveforms in radio, telemetry, and control interfaces when the required bandwidth fits its 100 kSPS conversion rate. The 16-bit output preserves amplitude detail, while serial I/O limits the number of data lines between the converter and a digital controller. Select the input range that matches the receiver or amplifier output, and use the external-reference capability when system-level accuracy must be coordinated across multiple converters. Because the 100 kSPS rate is 50% of the AD977A-family 200 kSPS option, verify acquisition bandwidth and serial-output timing before choosing this device for higher-frequency signals.
Precision Data-Acquisition Systems
The AD977BRS is appropriate for compact, high-resolution data-acquisition modules in laboratory, portable, and embedded measurement equipment. A 100 kSPS rate supports continuous sampling of many instrumentation signals, while the 16-bit ADC resolution captures variation that lower-resolution converters may quantize away. The single 5 V operating supply reduces rail-count requirements, and selectable unipolar and bipolar ranges accommodate both sensor outputs and conditioned laboratory signals. For a new board, follow the manufacturer reference configuration for bypass capacitors, reference selection, and digital-interface implementation. Confirm settling time and acquisition bandwidth against the intended source impedance.
Sensor Signal Conditioning
The AD977BRS can serve as the final conversion stage for bridge, pressure, strain, position, and other analog sensor interfaces. Its 16-bit resolution is valuable when the conditioned sensor signal occupies only part of the selected range, while the 100 kSPS throughput allows oversampling relative to many slow mechanical sensors. The ±3.3 V and ±5 V bipolar options can simplify interface to bipolar front ends, and the internal 2.5 V reference provides a convenient default. Use external-reference operation when multiple channels must share a reference or when calibration accuracy requires a dedicated reference. Protect the analog input path from transients and keep sensor returns separate from digital switching currents.
Portable Measurement Instruments
The AD977BRS fits portable meters and field instruments that need more measurement resolution than a simple comparator or low-resolution converter while remaining limited to a single 5 V supply. At 100 kSPS, it can capture repetitive measurements and waveforms within the acquisition bandwidth of the instrument. The power-down mode, specified at 50 µW, is valuable when the instrument spends substantial time between measurement bursts. Designers should still budget the 100 mW maximum device dissipation during active conversion and use the manufacturer power-down and startup guidance to avoid reading unsettled data. The 28-SSOP package also supports compact layouts compared with larger through-hole converter options.
Medical and Diagnostic Instrumentation
The AD977BRS may be used in diagnostic and monitoring instruments when the signal bandwidth is compatible with 100 kSPS conversion and the system requires 16-bit digital resolution. Suitable examples include slow physiological trend acquisition and controlled laboratory measurement blocks rather than wideband waveform capture. The selectable input ranges allow connection to bipolar front ends with appropriate scaling, while the internal 2.5 V reference or external-reference option supports different calibration architectures. Medical designs must add the required protection, isolation, leakage control, and regulatory validation at the system level. Do not infer medical certification from the ADC specifications, and verify all timing and accuracy limits against the current manufacturer datasheet.
Données de référence d'ingénierie pour AD977BRS — comparaison, recommandations de conception et informations de conformité.
Guide de sélection
Comparaison avec les alternatives
| Paramètre | Ce produit | AD977BRSZ | AD977BRU | AD977ARU |
|---|---|---|---|---|
| Package | 28-pin SSOP | 28-pin SSOP | 28-pin SSOP | 28-pin SSOP |
| Brand | Analog Devices | Analog Devices | Analog Devices | Analog Devices |
| Resolution | 16 bit | 16 bit | 16 bit | 16 bit |
| Conversion Throughput | 100 kSPS | 100 kSPS | 100 kSPS | 200 kSPS |
| Supply Voltage | 5 V | 5 V | 5 V | 5 V |
| Interface | Serial I/O | Serial I/O | Serial I/O | Serial I/O |
Principaux différenciateurs
- Direct 100 kSPS match for moderate-bandwidth acquisition (vs AD977ARU)
- Same-package ordering alternative with identical headline conversion specifications (vs AD977BRSZ)
- Single-supply operation with broad selectable input ranges (vs AD977BRU)
Notes de conception
Assign every connection from the 28-pin SSOP pin-description table and keep analog input traces away from serial clock, data, and supply-switching traces. Place input filtering and the converter as close together as practical to minimize capacitive noise pickup. Use a continuous ground reference beneath and around the device, avoid routing sensitive analog signals over split plane boundaries, and follow the manufacturer reference layout for bypass-capacitor placement and single-ended grounding.
Design the 5 V rail for both transient demand and converter dissipation. The AD977BRS maximum power dissipation is 100 mW, but upstream regulators, reference circuitry, interface drivers, and protection networks can create additional local heating. Place the required bypass capacitance at the supply pins, keep analog and digital return-current paths controlled, and verify the 28-SSOP thermal performance using the manufacturer's junction-temperature guidance and the actual board copper area.
Establish the acquisition time before selecting input-range components and sampling rate. Source impedance, input capacitance, bandwidth, and the 100 kSPS conversion cadence determine whether the input settles accurately between conversions. Use the manufacturer input-impedance and acquisition specifications rather than assuming that every sensor can drive the selected range directly. If source impedance is high, add a low-noise, low-capacitance buffer and include its offset and noise in the system error budget.
Do not treat AD977BRS, AD977BRSZ, and AD977A-family devices as interchangeable solely because they use the same 28-SSOP outline. AD977A-family options can provide 200 kSPS rather than 100 kSPS, while ordering suffixes may change temperature grade, finish, or lifecycle conditions. Confirm the exact ordering code, acquisition timing, serial-interface timing, reference configuration, and production status before releasing a substitution into manufacturing.
Informations de conformité
No explicit compliance declarations were identified in the available manufacturer product description. Confirm RoHS, REACH, lead-free, halogen-free, and conflict-mineral status against the current Analog Devices product documentation and the exact ordering suffix before production release.