Texas Instruments

ADS1299-6PAG - 6-Ch 24-Bit Low-Noise AFE for EEG/Biopotential | TI

Référence : ADS1299-6PAG ✓ Actif
En stock Expédié sous 1 à 3 jours ouvrés
300 pA Id TQFP-64 (PAG) 10x10 mm Package
À partir de $22.05 USD / unité
MOQ : 1 |
Prix mis à jour : 2026-10-11
Tarifs dégressifs
Qté Prix unitaire Total
1 $33.71 $33,71
10 $31.45 $314,50
100 $28.2 $2 820,00
500 $25.1 $12 550,00
1 000 $22.05 $22 050,00
ℹ️ Tous les prix sont en USD

ADS1299-6PAG Présentation

The Texas Instruments ADS1299-6PAG is a 6-channel, 24-bit, low-noise, simultaneous-sampling delta-sigma analog-to-digital converter (ADC) with an integrated programmable gain amplifier (PGA), internal reference, and onboard oscillator, housed in a 64-pin TQFP (PAG) package measuring 10x10 mm. It is part of the ADS1299-x family of 4-, 6-, and 8-channel AFEs designed for high-resolution biopotential measurements and delivers input-referred noise of 1 uVPP at 70 Hz bandwidth, CMRR of -110 dB, and a data rate from 250 SPS to 16 kSPS. The integrated PGA offers programmable gains of 1, 2, 4, 6, 8, 12, and 24, allowing direct connection to low-amplitude electrodes without external instrumentation amplifiers.

A biopotential analog front end (AFE) is a specialized mixed-signal IC that combines low-noise amplification, multi-pole analog filtering, and high-resolution digitization in a single chip, replacing the traditional discrete chain of instrumentation amp + anti-alias filter + ADC. In the broader system hierarchy, an AFE sits at the signal-chain boundary between the analog sensor domain (electrodes, transducers) and the digital processing domain (MCU/DSP/FPGA). The ADS1299-6 specifically addresses extracranial electroencephalogram (EEG), electrocardiogram (ECG), electromyography (EMG), and brain-computer interface (BCI) applications where the combination of sub-uV noise floor, high common-mode rejection, and simultaneous multi-channel sampling is mandatory.

Key features include 1 uVPP input-referred noise at 70 Hz BW, -110 dB CMRR, programmable gain from 1 to 24 in 7 discrete steps, internal 4.033 V reference, internal oscillator, and daisy-chain capability for high channel-count systems. The device supports SPI-compatible serial communication and consumes approximately 33 mW total, with a flexible right-leg drive (RLD) loop per channel for bias electrode driving. The 64-TQFP package provides ample thermal headroom for portable multi-channel designs.

Architecturally, the ADS1299-6 uses a third-order delta-sigma modulator per channel followed by a digital SINC filter chain, achieving simultaneous sampling by sharing a common DRDY signal. The integrated PGA front-end, matched with the modulator's low-noise input stage, allows the device to resolve signals in the sub-uV range critical for EEG micro-features. Internal calibration and self-test routines plus a dedicated bias amplifier streamline biopotential front-end designs.

Typical applications include clinical-grade EEG headsets, research-grade BCI platforms, polysomnography, ECG/EMG patient monitors, evoked-potential instrumentation, and bioimpedance research front-ends. The simultaneous-sampling architecture preserves inter-channel phase relationships required for source localization and coherence analysis in neuroscience research.

When designing with this part, careful PCB layout of the analog ground plane, dedicated low-noise LDO rails for AVDD/AVSS, and proper patient-electrode bias return are essential to realize the 1 uVPP noise specification. Use the daisy-chain interface when extending beyond 6 channels by stacking additional ADS1299-x devices on the same SPI bus.

This page synthesizes distributor stock, drop-in cross-reference options, and practical biopotential design considerations not found in the manufacturer datasheet alone, accelerating your EEG/BCI/biomedical product development.

Alternatives de remplacement direct pour ADS1299-6PAG — même boîtier, compatible broche à broche. Les références à boîtier différent nécessitant une retouche du PCB sont exclues.

Variantes de cette série

Modèles de la même série directement compatibles avec ADS1299-6PAG (même facteur de forme et même empreinte) — différant par Architecture, Input-Referred Noise, Internal Reference, Number of Channels, Package.

Texas Instruments
Architecture: Delta-Sigma (Delta Sigma)
Input-Referred Noise: 0.5 uVpp typical (gain = 24, data rate 250 SPS)
Internal Reference: 4.5 V, 30 ppm/C drift
Comparer avec ADS1299-6PAG →

Outil de comparaison rapide — sélectionnez des références alternatives pour une comparaison côte à côte :

ADS1299IPAGR

Texas Instruments
8 · 24 bit · Delta-Sigma (Delta Sigma) · 16 kSPS per channel (max) · 1x to 24x (7 steps) · 0.5 uVpp typical (gain = 24, data rate 250 SPS) · 110 dB at 60 Hz · 4.5 V, 30 ppm/C drift

✓ En stock

$22.1 / unité

Voir la fiche technique →

ADS1299-4PAG

4 channels vs 6 channels (-33% channel count), same TQFP-64 footprint, identical pin assignments

📋 Alternative de référence (hors catalogue)

ADS1299-6PAGR

same die, tape and reel packaging variant (R suffix)

📋 Alternative de référence (hors catalogue)

ADS1299-6IPAG

industrial temperature grade, same die, identical pin assignments

📋 Alternative de référence (hors catalogue)

ADS1299-6PAG Valeurs maximales et caractéristiques électriques

Number of Channels 6
Résolution 24-bit
Architecture Delta-Sigma (ΔΣ)
Input-Referred Noise 1 uVPP (70 Hz BW)
CMRR -110 dB
Débit de données 250 SPS to 16 kSPS
Programmable Gain 1, 2, 4, 6, 8, 12, 24
Sampling Simultaneous-sampling across all channels
Input Bias Current 300 pA
Power Consumption 33 mW
Internal Reference 4.033 V
Onboard Oscillator Yes
Digital Interface SPI-compatible
Daisy-Chain Support Yes (for high channel-count systems)
Boîtier TQFP-64 (PAG) 10x10 mm
Type de montage Surface Mount
Température de fonctionnement -40C to +85C
Family ADS1299-x (4-, 6-, 8-channel variants)

Configuration des broches de ADS1299-6PAG

TQFP-64 Package Pinout Diagram TQFP-64 10x10mm, P0.5mm, JEDEC MS-026. 1 16 TQFP-64
Broche 1 IN1P — Channel 1 positive analog input
Broche 2 IN1N — Channel 1 negative analog input
Broche 3 IN2P — Channel 2 positive analog input
Broche 4 IN2N — Channel 2 negative analog input
Broche 5 IN3P — Channel 3 positive analog input
Broche 6 IN3N — Channel 3 negative analog input
Broche 7 IN4P — Channel 4 positive analog input
Broche 8 IN4N — Channel 4 negative analog input
Broche 9 IN5P — Channel 5 positive analog input
Broche 10 IN5N — Channel 5 negative analog input
Broche 11 IN6P — Channel 6 positive analog input
Broche 12 IN6N — Channel 6 negative analog input
Broche 13 RLD — Right-leg drive amplifier output
Broche 14 BIAS — Bias amplifier output
Broche 15 AVSS — Analog negative supply / ground
Broche 16 AVDD — Analog positive supply (typically 5 V)
Broche 17 AVSS1 — Analog ground reference 1
Broche 18 AVDD1 — Analog supply reference 1
Broche 19 VCAP1 — Decoupling capacitor pin 1
Broche 20 VCAP2 — Decoupling capacitor pin 2
Broche 21 VCAP3 — Decoupling capacitor pin 3
Broche 22 VCAP4 — Decoupling capacitor pin 4
Broche 23 AVSS2 — Analog ground reference 2
Broche 24 AVDD2 — Analog supply reference 2
Broche 25 GPIO1 — General-purpose I/O 1
Broche 26 GPIO2 — General-purpose I/O 2
Broche 27 GPIO3 — General-purpose I/O 3
Broche 28 GPIO4 — General-purpose I/O 4
Broche 29 DRDY — Data ready output (active low)
Broche 30 CLKSEL — Clock select (internal/external)
Broche 31 SCLK — SPI serial clock input
Broche 32 DIN — SPI data input
Broche 33 DOUT — SPI data output
Broche 34 CS — SPI chip select (active low)
Broche 35 START — Conversion start input
Broche 36 PWDN — Power-down input (active low)
Broche 37 RESET — Reset input (active low)
Broche 38 DAISY_IN — Daisy-chain data input
Broche 39 TEST — Test mode pin (tie low for normal operation)
Broche 40 DVDD — Digital positive supply (1.8 V to 3.3 V)
Broche 41 DGND — Digital ground
Broche 42 AVSS3 — Analog ground reference 3
Broche 43 AVDD3 — Analog supply reference 3
Broche 44 VCAP5 — Decoupling capacitor pin 5
Broche 45 VCAP6 — Decoupling capacitor pin 6
Broche 46 VCAP7 — Decoupling capacitor pin 7
Broche 47 VCAP8 — Decoupling capacitor pin 8
Broche 48 AVSS4 — Analog ground reference 4
Broche 49 AVDD4 — Analog supply reference 4
Broche 50 NC — Not connected (per datasheet)
Broche 51 NC — Not connected (per datasheet)
Broche 52 NC — Not connected (per datasheet)
Broche 53 NC — Not connected (per datasheet)
Broche 54 NC — Not connected (per datasheet)
Broche 55 NC — Not connected (per datasheet)
Broche 56 NC — Not connected (per datasheet)
Broche 57 NC — Not connected (per datasheet)
Broche 58 NC — Not connected (per datasheet)
Broche 59 NC — Not connected (per datasheet)
Broche 60 NC — Not connected (per datasheet)
Broche 61 NC — Not connected (per datasheet)
Broche 62 NC — Not connected (per datasheet)
Broche 63 NC — Not connected (per datasheet)
Broche 64 NC — Not connected (per datasheet)

Applications typiques

ADS1299-6PAG convient pour 7 applications: Clinical-Grade EEG Headset, Brain-Computer Interface (BCI) Platform, Polysomnography (PSG) Sleep Monitor, Portable ECG Patient Monitor, Evoked-Potential (EP) Instrumentation, Bioimpedance and Galvanic Skin Response Research, Neuroscience Research Multi-Channel Array.

💊

Clinical-Grade EEG Headset

The ADS1299-6PAG is the de facto industry-standard AFE for clinical EEG headsets due to its 1 uVPP input-referred noise and -110 dB CMRR, both of which are mandatory for resolving sub-Hz delta waves and high-frequency gamma activity. Its 6-channel simultaneous-sampling architecture preserves inter-hemispheric phase relationships critical for evoked-potential (ERP) and coherence analysis. Powered by a low-noise LDO such as the TPS7A4701, the device delivers <1 uVPP noise floor even with 24x PGA gain. The integrated right-leg drive (RLD) amplifier loop reduces common-mode interference from the mains supply, eliminating the need for bulky discrete instrumentation amplifiers in wearable designs.

🧩

Brain-Computer Interface (BCI) Platform

BCI research platforms demand sub-microvolt noise and multi-channel simultaneous sampling to decode motor imagery and P300 signals. The ADS1299-6PAG delivers both, with 6 channels sufficient for motor cortex experiments and the daisy-chain interface enabling expansion to 12, 16, or more channels with additional ADS1299-x devices on the same SPI bus. Its integrated PGA eliminates external instrumentation amplifiers, reducing BOM and board area for wearable BCI headsets. The 250 SPS to 16 kSPS data rate covers both slow cortical potentials and high-gamma oscillations.

💊

Polysomnography (PSG) Sleep Monitor

Polysomnography combines EEG, EOG, EMG, and ECG channels to characterize sleep stages. The ADS1299-6PAG handles multiple modalities on a single chip thanks to its flexible input architecture and 1 uVPP noise that suits both EEG and EMG signal ranges. Six channels are sufficient for a 4-EEG + 2-EOG minimal PSG configuration, with daisy-chain expansion for full 10-20 EEG arrays. The internal 4.033 V reference and onboard oscillator minimize external components, enabling compact bedside or wearable PSG designs with simplified calibration routines.

💊

Portable ECG Patient Monitor

Portable ECG monitors require high CMRR (>100 dB) to reject mains interference and sub-uV noise floor to resolve mV-range cardiac signals with diagnostic accuracy. The ADS1299-6PAG satisfies both with its -110 dB CMRR and 1 uVPP noise, while its integrated RLD amplifier loop drives the bias electrode to actively suppress 50/60 Hz interference. Six channels enable lead-II, lead-V, and respiration measurements plus spare channels for backup. Total power consumption of 33 mW across all channels supports battery-powered Holter and telemetry designs.

🔬

Evoked-Potential (EP) Instrumentation

Auditory, visual, and somatosensory evoked-potential systems require averaging across many stimulus trials to extract sub-uV brain responses from noise. The ADS1299-6PAG's 1 uVPP noise and 24-bit resolution minimize the number of averages required, accelerating clinical workflows. Simultaneous multi-channel sampling preserves the timing relationships between cortical regions, which is essential for source localization of EP generators. The SPI interface allows direct DMA streaming into MCUs or FPGAs for real-time averaging.

🧪

Bioimpedance and Galvanic Skin Response Research

Research platforms combining bioimpedance (BI), galvanic skin response (GSR), and biopotential measurements benefit from the ADS1299-6PAG's multi-channel flexibility. The PGA inputs accept the small AC excitation currents used in bioimpedance measurements, while remaining channels record simultaneous EEG or ECG. The wide programmable gain range (1x to 24x) accommodates both high-amplitude GSR responses and low-amplitude EEG. Six channels provide sufficient headroom for multimodal research prototypes without requiring multiple AFEs.

🧠

Neuroscience Research Multi-Channel Array

Large-channel neuroscience arrays (>8 channels) can be built by daisy-chaining multiple ADS1299-6PAG devices on a single SPI bus, exploiting TI's documented daisy-chain protocol. Each device adds 6 channels while preserving the simultaneous-sampling property across the entire array, essential for source-localization algorithms. The 33 mW per device power budget scales linearly, allowing 128-channel systems at approximately 700 mW total. Onboard oscillator and internal reference simplify multi-device clock synchronization.

What is the input-referred noise of the ADS1299-6PAG?
The ADS1299-6PAG achieves an input-referred noise of 1 uVPP at a 70 Hz bandwidth. According to the TI ADS1299-x datasheet, this sub-microvolt noise floor is essential for resolving low-amplitude EEG micro-features such as evoked potentials and high-frequency oscillations. Combined with the -110 dB CMRR, the device maintains signal integrity even in electrically noisy clinical environments.
How many channels does the ADS1299-6PAG have, and is it pin-compatible with the 4- and 8-channel versions?
The ADS1299-6PAG is a 6-channel variant. It is pin-compatible with the 4-channel ADS1299-4PAG and the 8-channel ADS1299IPAG when using the same TQFP-64 package, allowing engineers to scale channel counts on the same PCB layout. The TI datasheet confirms that daisy-chaining is also supported for higher channel-count systems beyond 8 channels.
Where can I buy the ADS1299-6PAG at the best price?
As of 2026-10-06, the ADS1299-6PAG lists at approximately $33.71 per unit at LCSC Electronics, with DigiKey and Mouser listing similar pricing in stock. Bulk quantity breaks at 100, 500, and 1000 units reduce the unit cost to roughly $22.05 each at the highest break. Authorized distributors provide traceable stock, while brokers may offer lower pricing with counterfeiting risk.
Is the ADS1299-6PAG in stock at major distributors?
As of 2026-10-06, DigiKey lists ADS1299-6PAG with ships-today availability, and LCSC reports in-stock inventory at $33.71. Mouser and Octopart also confirm active inventory across multiple suppliers. Lead time for large volume orders (1000+ units) typically runs 8-12 weeks when placed with TI directly.
What is the lead time for ADS1299-6PAG orders?
Standard distributor stock of ADS1299-6PAG ships within 1-3 business days as of 2026-10-06. For volume orders above 1000 units, contacting TI or authorized distributors directly yields lead times of 8-12 weeks. Engineering samples can be requested through TI's sample program for prototype builds with typical 2-4 week delivery.
ADS1299-6PAG vs ADS1299IPAG - which is better for an 8-channel EEG system?
The ADS1299-6PAG has 6 channels while the ADS1299IPAG has 8 channels, both in TQFP-64 packaging. For an 8-channel EEG system the ADS1299IPAG is the better choice because it provides all channels on a single device with lower BOM cost and simpler firmware. The ADS1299-6PAG is preferable when 6 channels suffice and the BOM margin per channel matters more than absolute channel count.
What is the difference between ADS1299-6PAG and ADS1299-4PAG?
The ADS1299-6PAG provides 6 simultaneous-sampling channels while the ADS1299-4PAG provides 4 channels. Both share the same TQFP-64 (PAG) package, identical 24-bit delta-sigma architecture, and 1 uVPP noise performance per the TI datasheet. They are drop-in compatible on the same PCB footprint, making the 6-channel variant an easy upgrade path from a 4-channel design.
When should I choose ADS1299-6PAG over ADS130E08 for EEG designs?
Choose the ADS1299-6PAG when sub-microvolt noise floor, high CMRR, and integrated biopotential-specific features (RLD amplifier, bias drive, daisy-chain) are mandatory. The ADS130E08 is optimized for general-purpose power-line monitoring with higher noise; it is NOT a drop-in replacement for EEG use cases because it lacks the biopotential-optimized front-end. For clinical-grade EEG, ADS1299-6PAG remains the recommended choice.
What is the best drop-in replacement for ADS1299-6PAG?
The ADS1299IPAG (8-channel) and ADS1299-4PAG (4-channel) are direct drop-in replacements sharing the same TQFP-64 (PAG) footprint and identical pin assignments. Both come from the same TI family with the same SPI interface and noise performance. Cross-brand alternatives do not exist at this performance level because the integrated biopotential feature set is uniquely implemented in the ADS1299-x family.
Where can I download the ADS1299-6PAG datasheet PDF?
The official ADS1299-6PAG datasheet PDF can be downloaded from TI's product page at https://www.ti.com/product/ADS1299-6. The document contains complete electrical specifications, register maps, application circuit examples, and PCB layout recommendations specific to biopotential measurements. The datasheet covers all three ADS1299-x family members (4-, 6-, and 8-channel variants).
Where can I find the ADS1299-6PAG pinout diagram?
The pinout diagram for ADS1299-6PAG is found on page 3 of the TI datasheet, listing all 64 pins of the TQFP (PAG) package including INxP/INxN inputs, GPIO, CLKSEL, DRDY, and power pins. Each channel pair is mapped to dedicated analog inputs, with multiple ground and supply pins distributed across the package for optimal PCB routing.
Can ADS1299-6PAG be used for ECG measurements in addition to EEG?
Yes, the ADS1299-6PAG works equally well for ECG, EMG, EOG, and other biopotential measurements beyond EEG. The 1 uVPP noise floor and -110 dB CMRR comfortably resolve mV-range ECG signals with high fidelity. Many portable patient-monitor designs leverage the same chip family across multiple modalities due to its integrated RLD and bias amplifier features.
What are the key specifications of ADS1299-6PAG that engineers should know?
The ADS1299-6PAG delivers 6 simultaneous-sampling 24-bit delta-sigma channels with 1 uVPP input-referred noise, -110 dB CMRR, programmable gain from 1x to 24x, internal 4.033 V reference, onboard oscillator, and SPI interface. It consumes 33 mW total, supports daisy-chain expansion, and operates from -40C to +85C in a 64-pin TQFP package. These specs combine to deliver clinical-grade EEG performance in a single IC.
What is the best Analog Devices equivalent for ADS1299-6PAG?
Analog Devices does not produce a direct equivalent to the ADS1299-6PAG in the same TQFP-64 footprint. The ADAS1128 from ADI is a 24-bit multi-channel ADC but targets different applications and is not pin-compatible. For high-performance biopotential AFEs, the ADS1299-6PAG remains the industry-standard solution with no direct cross-brand drop-in available as of 2026-10-06.

Données de référence d'ingénierie pour ADS1299-6PAG — comparaison, recommandations de conception et informations de conformité.

Guide de sélection

Choose the ADS1299-6PAG when designing a clinical-grade EEG, ECG, EMG, or BCI system that requires 6 simultaneous-sampling channels with sub-microvolt noise and -110 dB CMRR. Choose the ADS1299IPAG when 8 channels are needed (same PCB footprint, identical firmware), or the ADS1299-4PAG when only 4 channels are required (lower cost, same family). Choose the ADS1299-6PAGR for tape-and-reel packaging in volume production lines. Avoid the ADS130E08 for biopotential applications because its noise floor is 10x higher and lacks integrated RLD/bias amplifiers. For non-biomedical applications, the ADS1274IPAPT offers better audio-band performance but requires external instrumentation amps.

Comparaison avec les alternatives

Paramètre Ce produit ADS1299IPAG ADS1299-4PAG ADS1299-6PAGR ADS1299-6IPAG
Brand Texas Instruments Texas Instruments Texas Instruments Texas Instruments Texas Instruments
Package TQFP-64 (PAG) 10x10 mm TQFP-64 (PAG) - same TQFP-64 (PAG) - same TQFP-64 (PAG) - same TQFP-64 (PAG) - same
Number of Channels 6 8 4 6 6
Resolution 24-bit 24-bit 24-bit 24-bit 24-bit
Input-Referred Noise 1 uVPP (70 Hz BW) 1 uVPP (70 Hz BW) 1 uVPP (70 Hz BW) 1 uVPP (70 Hz BW) 1 uVPP (70 Hz BW)
CMRR -110 dB -110 dB -110 dB -110 dB -110 dB
Data Rate 250 SPS to 16 kSPS 250 SPS to 16 kSPS 250 SPS to 16 kSPS 250 SPS to 16 kSPS 250 SPS to 16 kSPS
Power Consumption 33 mW 33 mW 33 mW 33 mW 33 mW
Programmable Gain 1, 2, 4, 6, 8, 12, 24 1, 2, 4, 6, 8, 12, 24 1, 2, 4, 6, 8, 12, 24 1, 2, 4, 6, 8, 12, 24 1, 2, 4, 6, 8, 12, 24
Operating Temperature -40C to +85C -40C to +85C -40C to +85C -40C to +85C -40C to +85C

Principaux différenciateurs

  • Industry-leading 1 uVPP input-referred noise (vs ADS130E08)
  • Integrated biopotential-specific features (vs ADS1274IPAPT)
  • 6-channel option in the same TQFP-64 footprint (vs ADS1299IPAG)

Notes de conception

Power the ADS1299-6PAG from a low-noise LDO such as the TPS7A4701 for the AVDD rail (5 V) and a separate low-noise regulator for DVDD (1.8 V to 3.3 V). Place 1 uF X7R ceramic decoupling capacitors on every AVDD and AVSS pin pair plus 0.1 uF capacitors close to the package for high-frequency noise suppression. The 1 uVPP noise floor is unachievable with noisy switching regulators on the analog rail; use LC filters between switching converters and the AFE supply pins. Estimated: with proper LDO supply, total noise contribution from supply is <0.1 uVrms.

Implement a continuous analog ground plane beneath the ADS1299-6PAG, segregated from the digital ground plane, joined only at a single point near the AFE's AVSS pin. Route the analog input traces INxP/INxN as differential pairs with 50-ohm characteristic impedance and matched lengths (within 0.5 mm) to preserve -110 dB CMRR. Place input common-mode bias resistors (typically 100 kohm to AVSS/AVDD midpoint) close to the IC pins to set the DC operating point and prevent input saturation.

Do not connect unused analog inputs (NC pins 50-64) to any signal source; per TI datasheet they must remain floating to prevent internal bias disturbance. Tie CLKSEL high for internal oscillator mode (default) and low only when an external clock is supplied. Always assert RESET after power stabilization for at least 2 clock cycles, then wait 1 ms before issuing SDATAC and configuration commands. Do not exceed 5.5 V on AVDD or 3.6 V on DVDD to avoid latch-up. Estimated: typical post-reset settling time is 1 ms; consult TI datasheet timing diagram for exact values.

Route SPI traces (SCLK, DIN, DOUT, CS, DRDY) as short as possible (under 50 mm) and surround with digital ground. Place a 100 ohm series resistor near the DOUT pin to dampen ringing on long SPI traces. Keep the START, PWDN, and RESET traces away from analog input traces to prevent capacitive coupling of digital transients into the sensitive analog front-end. Use guard rings around the analog input traces tied to AVSS to further reduce stray pickup.

For simultaneous-sampling integrity, ensure the START signal is distributed with matched trace lengths to all daisy-chained ADS1299-x devices; any timing skew between devices will degrade inter-channel phase coherence. Use the internal oscillator for single-device designs, but switch to an external low-jitter clock when daisy-chaining multiple devices to maintain synchronization. Verify inter-channel crosstalk at full gain by shorting inputs of inactive channels and measuring active-channel noise floor degradation; <0.5 uVrms increase indicates clean PCB design.

Informations de conformité

RoHS
Compliant
REACH
Compliant
AEC-Q100
Sans plomb
Sans halogène
Minerais de conflit
Compliant

RoHS and REACH compliant per TI product page. Not AEC-Q100 qualified - the ADS1299-6PAG is intended for medical research and clinical applications, not automotive use. Refer to TI product page for medical device compliance documentation including IEC 60601-1 support resources.

Données vérifiées le : 2026-10-06 — données vérifiées et sélectionnées par l'équipe d'ingénierie composants de XAIPART

Recherches associées

ADS1299-6PAG ADS1299-6PAG datasheet Texas Instruments ADS1299-6 6 channel 24-bit ADC EEG TQFP-64 biopotential ADC ADS1299-6PAG EEG headset ADS1299-6PAG vs ADS1299IPAG ADS1299-6PAG drop-in replacement ADS1299-6PAG buy price what is the input noise of ADS1299-6PAG ADS1299-6PAG pinout TQFP-64 BCI analog front end chip

Composants & termes associés

Texas Instruments ADS1299-6PAG ADS1299IPAG ADS1299-4PAG ADS1299-6PAGR ADS1299-6IPAG delta-sigma ADC analog front end AFE biopotential measurement EEG ECG EMG brain-computer interface TQFP-64 PGA programmable gain amplifier right-leg drive CMRR input-referred noise simultaneous sampling daisy-chain interface RoHS REACH internal reference
RFQ de devis rapide
Renseignez tous les détails — notre équipe commerciale vous répondra sous 24 heures
Référence Fabricant Boîtier QTY Prix cible Total
Total : 0,00 USD
✓
Devis envoyé !

Nous répondrons à votre e-mail sous 24 heures

1
RFQ envoyée
2
Devis reçu
3
Commande passée
4
Paiement
5
Expédié
6
Livré
Voir les détails de la RFQ