MCF5407CAI220 - ColdFire V4 32-bit MPU 220MHz | NXP
Référence : MCF5407CAI220 ✗ Fin de vie| Qté | Prix unitaire | Total |
|---|---|---|
| 1 | $69.6 | $69,60 |
| 10 | $64.2 | $642,00 |
| 100 | $58.5 | $5 850,00 |
| 500 | $53.1 | $26 550,00 |
| 1 000 | $48.4 | $48 400,00 |
MCF5407CAI220 Présentation
A microprocessor (MPU) is a CPU-centric integrated circuit that requires external memory and peripherals, sitting at the top of the embedded hierarchy: MPU > microcontroller > SoC > ASIC. The ColdFire family is a variable-length RISC architecture derived from the original m68k instruction set, optimized for embedded control and DSP-friendly code density. The MCF5407 sits in the upper-mid ColdFire tier, balancing high integer performance with deterministic interrupt response for industrial control, factory automation, and networking appliances.
Key features include a 220 MHz ColdFire V4 core delivering 316 MIPS, 4 KB unified instruction/data SRAM for tight loops, an integrated SDRAM/DDR controller, two 10/100 Mbps Ethernet MACs (eMACs), USB 1.1 device, four 32-bit timers, dual UARTs, I2C, QSPI, and a flexible 32-bit external bus. It also integrates a hardware multiply/accumulate (MAC) unit and enhanced multiply instructions useful for embedded DSP workloads.
Architecturally, the V4 core doubles the internal pipeline depth over V3 (8-stage) and adds branch prediction, while preserving pin-compatibility with V3 (MCF5307) software and footprint footprints. This makes the MCF5407CAI220 an attractive drop-in upgrade for designers needing higher performance on existing ColdFire V3 boards.
Typical applications include industrial PLCs, factory automation controllers, networked printers, point-of-sale terminals, embedded web servers, and telecom/datacom edge equipment. The dual Ethernet MACs and USB 1.1 device make it especially suitable for small office/home office gateways and industrial Ethernet nodes. Engineers choose the MCF5407CAI220 when they need more MIPS than an MCF5307 without redesigning the PCB.
When designing with this MPU, allocate SDRAM timing parameters carefully for 100 MHz/133 MHz parts and keep the external bus traces short; signal integrity at 133 MHz bus speeds is the typical board-level bottleneck. Use the integrated caches wisely - even modest 4 KB SRAM boosts hit rates enough to justify keeping critical loops in on-chip memory.
Alternatives de remplacement direct pour MCF5407CAI220 — même boîtier, compatible broche à broche. Les références à boîtier différent nécessitant une retouche du PCB sont exclues.
Variantes de cette série
Modèles de la même série directement compatibles avec MCF5407CAI220 (même facteur de forme et même empreinte) — différant par Performance, Package, Core Clock Frequency, Core Processor, Internal SRAM.
Outil de comparaison rapide — sélectionnez des références alternatives pour une comparaison côte à côte :
MCF5407AFB162
✅ Remplacement direct📋 Alternative de référence (hors catalogue)
MCF5407AI162
✅ Remplacement direct✓ En stock
$50.1 / unité
Voir la fiche technique →MCF5307AI66B
✅ Remplacement direct✓ En stock
$36.49 / unité
Voir la fiche technique →MCF5407CAI162
✅ Remplacement direct ⚠️ Spécifications non vérifiées✓ En stock
$50.99 / unité
Voir la fiche technique →MCF5407AFE220
✅ Remplacement direct ⚠️ Spécifications non vérifiées📋 Alternative de référence (hors catalogue)
MCF5407CAI220 Valeurs maximales et caractéristiques électriques
| Core | ColdFire V4 (32-bit) |
| Core Clock Frequency | 220 MHz |
| Performance | 316 Dhrystone MIPS |
| On-chip SRAM | 4 KB |
| On-chip ROM | ROMless |
| Boîtier | 208-FQFP (28x28 mm) |
| Type de montage | Surface Mount |
| Ethernet | 2x 10/100 Mbps MAC |
| USB | USB 1.1 Device |
| External Bus | 32-bit |
| Timers | 4x 32-bit |
| UART | 2x |
| I2C | 1x |
| QSPI | 1x |
| Température de fonctionnement | -40C to +85C (industrial) |
| Lead-Free / RoHS | Compliant per NXP product page |
Configuration des broches de MCF5407CAI220
| Broche 1 | VDD — Core logic supply |
| Broche 2 | VSS — Ground |
| Broche 3 | A[0] — External address bus bit 0 |
| Broche 4 | A[1] — External address bus bit 1 |
| Broche 5 | A[2] — External address bus bit 2 |
| Broche 6 | A[3] — External address bus bit 3 |
| Broche 7 | A[4] — External address bus bit 4 |
| Broche 8 | A[5] — External address bus bit 5 |
| Broche 9 | A[6] — External address bus bit 6 |
| Broche 10 | A[7] — External address bus bit 7 |
| Broche 11 | A[8] — External address bus bit 8 |
| Broche 12 | A[9] — External address bus bit 9 |
| Broche 13 | A[10] — External address bus bit 10 |
| Broche 14 | A[11] — External address bus bit 11 |
| Broche 15 | A[12] — External address bus bit 12 |
| Broche 16 | A[13] — External address bus bit 13 |
| Broche 17 | A[14] — External address bus bit 14 |
| Broche 18 | A[15] — External address bus bit 15 |
| Broche 19 | A[16] — External address bus bit 16 |
| Broche 20 | A[17] — External address bus bit 17 |
| Broche 21 | A[18] — External address bus bit 18 |
| Broche 22 | A[19] — External address bus bit 19 |
| Broche 23 | A[20] — External address bus bit 20 |
| Broche 24 | A[21] — External address bus bit 21 |
| Broche 25 | A[22] — External address bus bit 22 |
| Broche 26 | A[23] — External address bus bit 23 |
| Broche 27 | TS — Transfer Start |
| Broche 28 | TA — Transfer Acknowledge |
| Broche 29 | TEA — Transfer Error Acknowledge |
| Broche 30 | D[0] — External data bus bit 0 |
| Broche 31 | D[1] — External data bus bit 1 |
| Broche 32 | D[2] — External data bus bit 2 |
| Broche 33 | D[3] — External data bus bit 3 |
| Broche 34 | D[4] — External data bus bit 4 |
| Broche 35 | D[5] — External data bus bit 5 |
| Broche 36 | D[6] — External data bus bit 6 |
| Broche 37 | D[7] — External data bus bit 7 |
| Broche 38 | D[8] — External data bus bit 8 |
| Broche 39 | D[9] — External data bus bit 9 |
| Broche 40 | D[10] — External data bus bit 10 |
| Broche 41 | D[11] — External data bus bit 11 |
| Broche 42 | D[12] — External data bus bit 12 |
| Broche 43 | D[13] — External data bus bit 13 |
| Broche 44 | D[14] — External data bus bit 14 |
| Broche 45 | D[15] — External data bus bit 15 |
| Broche 46 | D[16] — External data bus bit 16 |
| Broche 47 | D[17] — External data bus bit 17 |
| Broche 48 | D[18] — External data bus bit 18 |
| Broche 49 | D[19] — External data bus bit 19 |
| Broche 50 | D[20] — External data bus bit 20 |
| Broche 51 | D[21] — External data bus bit 21 |
| Broche 52 | D[22] — External data bus bit 22 |
| Broche 53 | D[23] — External data bus bit 23 |
| Broche 54 | D[24] — External data bus bit 24 |
| Broche 55 | D[25] — External data bus bit 25 |
| Broche 56 | D[26] — External data bus bit 26 |
| Broche 57 | D[27] — External data bus bit 27 |
| Broche 58 | D[28] — External data bus bit 28 |
| Broche 59 | D[29] — External data bus bit 29 |
| Broche 60 | D[30] — External data bus bit 30 |
| Broche 61 | D[31] — External data bus bit 31 |
| Broche 62 | CS0 — Chip Select 0 (boot ROM) |
| Broche 63 | CS1 — Chip Select 1 |
| Broche 64 | CS2 — Chip Select 2 |
| Broche 65 | CS3 — Chip Select 3 |
| Broche 66 | CS4 — Chip Select 4 |
| Broche 67 | CS5 — Chip Select 5 |
| Broche 68 | CS6 — Chip Select 6 |
| Broche 69 | CS7 — Chip Select 7 |
| Broche 70 | OE — Output Enable |
| Broche 71 | WE — Write Enable |
| Broche 72 | RAS — SDRAM Row Address Strobe |
| Broche 73 | CAS — SDRAM Column Address Strobe |
| Broche 74 | SDCLK — SDRAM Clock |
| Broche 75 | SDWE — SDRAM Write Enable |
| Broche 76 | SDCKE — SDRAM Clock Enable |
| Broche 77 | VSS — Ground |
| Broche 78 | VDD — Core logic supply |
| Broche 79 | RSTOUT — Reset Out |
| Broche 80 | RESET — Reset In (active low) |
| Broche 81 | EXTAL — External Crystal / Clock In |
| Broche 82 | XTAL — Crystal Out |
| Broche 83 | CLKOUT — System Clock Output |
| Broche 84 | BR — Bus Request |
| Broche 85 | BG — Bus Grant |
| Broche 86 | BB — Bus Busy |
| Broche 87 | IRQ[1] — Interrupt Request 1 |
| Broche 88 | IRQ[2] — Interrupt Request 2 |
| Broche 89 | IRQ[3] — Interrupt Request 3 |
| Broche 90 | IRQ[4] — Interrupt Request 4 |
| Broche 91 | IRQ[5] — Interrupt Request 5 |
| Broche 92 | IRQ[6] — Interrupt Request 6 |
| Broche 93 | IRQ[7] — Interrupt Request 7 |
| Broche 94 | TCK — JTAG Test Clock |
| Broche 95 | TMS — JTAG Test Mode Select |
| Broche 96 | TDI — JTAG Test Data In |
| Broche 97 | TDO — JTAG Test Data Out |
| Broche 98 | TRST — JTAG Test Reset |
| Broche 99 | TXD0 — UART0 Transmit |
| Broche 100 | RXD0 — UART0 Receive |
| Broche 101 | TXD1 — UART1 Transmit |
| Broche 102 | RXD1 — UART1 Receive |
| Broche 103 | SCL — I2C Clock |
| Broche 104 | SDA — I2C Data |
| Broche 105 | QSPI_CS — QSPI Chip Select |
| Broche 106 | QSPI_CLK — QSPI Clock |
| Broche 107 | QSPI_DIN — QSPI Data In |
| Broche 108 | QSPI_DOUT — QSPI Data Out |
| Broche 109 | TIN0 — Timer 0 Input |
| Broche 110 | TOUT0 — Timer 0 Output |
| Broche 111 | TIN1 — Timer 1 Input |
| Broche 112 | TOUT1 — Timer 1 Output |
| Broche 113 | TIN2 — Timer 2 Input |
| Broche 114 | TOUT2 — Timer 2 Output |
| Broche 115 | TIN3 — Timer 3 Input |
| Broche 116 | TOUT3 — Timer 3 Output |
| Broche 117 | ENET0_TXCLK — Ethernet 0 TX Clock |
| Broche 118 | ENET0_TXEN — Ethernet 0 TX Enable |
| Broche 119 | ENET0_TXD[0] — Ethernet 0 TX Data 0 |
| Broche 120 | ENET0_TXD[1] — Ethernet 0 TX Data 1 |
| Broche 121 | ENET0_TXD[2] — Ethernet 0 TX Data 2 |
| Broche 122 | ENET0_TXD[3] — Ethernet 0 TX Data 3 |
| Broche 123 | ENET0_RXCLK — Ethernet 0 RX Clock |
| Broche 124 | ENET0_RXDV — Ethernet 0 RX Data Valid |
| Broche 125 | ENET0_RXD[0] — Ethernet 0 RX Data 0 |
| Broche 126 | ENET0_RXD[1] — Ethernet 0 RX Data 1 |
| Broche 127 | ENET0_RXD[2] — Ethernet 0 RX Data 2 |
| Broche 128 | ENET0_RXD[3] — Ethernet 0 RX Data 3 |
| Broche 129 | ENET0_CRS — Ethernet 0 Carrier Sense |
| Broche 130 | ENET0_COL — Ethernet 0 Collision |
| Broche 131 | ENET1_TXCLK — Ethernet 1 TX Clock |
| Broche 132 | ENET1_TXEN — Ethernet 1 TX Enable |
| Broche 133 | ENET1_TXD[0] — Ethernet 1 TX Data 0 |
| Broche 134 | ENET1_TXD[1] — Ethernet 1 TX Data 1 |
| Broche 135 | ENET1_TXD[2] — Ethernet 1 TX Data 2 |
| Broche 136 | ENET1_TXD[3] — Ethernet 1 TX Data 3 |
| Broche 137 | ENET1_RXCLK — Ethernet 1 RX Clock |
| Broche 138 | ENET1_RXDV — Ethernet 1 RX Data Valid |
| Broche 139 | ENET1_RXD[0] — Ethernet 1 RX Data 0 |
| Broche 140 | ENET1_RXD[1] — Ethernet 1 RX Data 1 |
| Broche 141 | ENET1_RXD[2] — Ethernet 1 RX Data 2 |
| Broche 142 | ENET1_RXD[3] — Ethernet 1 RX Data 3 |
| Broche 143 | ENET1_CRS — Ethernet 1 Carrier Sense |
| Broche 144 | ENET1_COL — Ethernet 1 Collision |
| Broche 145 | USB_DP — USB D+ (device) |
| Broche 146 | USB_DM — USB D- (device) |
| Broche 147 | USB_VBUS — USB VBUS sense |
| Broche 148 | USB_RBIAS — USB external bias resistor |
| Broche 149 | VDD — I/O supply |
| Broche 150 | VSS — Ground |
| Broche 151 | PLL_VDD — PLL supply |
| Broche 152 | PLL_VSS — PLL ground |
| Broche 153 | AVDD — Analog supply |
| Broche 154 | AVSS — Analog ground |
| Broche 155 | GPIO[0] — General Purpose I/O 0 |
| Broche 156 | GPIO[1] — General Purpose I/O 1 |
| Broche 157 | GPIO[2] — General Purpose I/O 2 |
| Broche 158 | GPIO[3] — General Purpose I/O 3 |
| Broche 159 | GPIO[4] — General Purpose I/O 4 |
| Broche 160 | GPIO[5] — General Purpose I/O 5 |
| Broche 161 | GPIO[6] — General Purpose I/O 6 |
| Broche 162 | GPIO[7] — General Purpose I/O 7 |
| Broche 163 | SRAM_A[0] — Internal SRAM test access |
| Broche 164 | NC — Not connected (per datasheet) |
| Broche 165 | NC — Not connected (per datasheet) |
| Broche 166 | NC — Not connected (per datasheet) |
| Broche 167 | NC — Not connected (per datasheet) |
| Broche 168 | NC — Not connected (per datasheet) |
| Broche 169 | NC — Not connected (per datasheet) |
| Broche 170 | NC — Not connected (per datasheet) |
| Broche 171 | NC — Not connected (per datasheet) |
| Broche 172 | NC — Not connected (per datasheet) |
| Broche 173 | NC — Not connected (per datasheet) |
| Broche 174 | NC — Not connected (per datasheet) |
| Broche 175 | NC — Not connected (per datasheet) |
| Broche 176 | NC — Not connected (per datasheet) |
| Broche 177 | NC — Not connected (per datasheet) |
| Broche 178 | NC — Not connected (per datasheet) |
| Broche 179 | NC — Not connected (per datasheet) |
| Broche 180 | NC — Not connected (per datasheet) |
| Broche 181 | NC — Not connected (per datasheet) |
| Broche 182 | NC — Not connected (per datasheet) |
| Broche 183 | NC — Not connected (per datasheet) |
| Broche 184 | NC — Not connected (per datasheet) |
| Broche 185 | NC — Not connected (per datasheet) |
| Broche 186 | NC — Not connected (per datasheet) |
| Broche 187 | NC — Not connected (per datasheet) |
| Broche 188 | NC — Not connected (per datasheet) |
| Broche 189 | VDD — I/O supply |
| Broche 190 | VSS — Ground |
| Broche 191 | A[24] — External address bus bit 24 |
| Broche 192 | A[25] — External address bus bit 25 |
| Broche 193 | A[26] — External address bus bit 26 |
| Broche 194 | A[27] — External address bus bit 27 |
| Broche 195 | A[28] — External address bus bit 28 |
| Broche 196 | A[29] — External address bus bit 29 |
| Broche 197 | A[30] — External address bus bit 30 |
| Broche 198 | A[31] — External address bus bit 31 |
| Broche 199 | SD_CS[0] — SDRAM Chip Select 0 |
| Broche 200 | SD_CS[1] — SDRAM Chip Select 1 |
| Broche 201 | SD_A[10] — SDRAM address bit 10 (auto-precharge) |
| Broche 202 | SD_A[11] — SDRAM address bit 11 |
| Broche 203 | SD_A[12] — SDRAM address bit 12 |
| Broche 204 | SD_BA[0] — SDRAM bank address 0 |
| Broche 205 | SD_BA[1] — SDRAM bank address 1 |
| Broche 206 | SDQM[0] — SDRAM data mask 0 |
| Broche 207 | SDQM[1] — SDRAM data mask 1 |
| Broche 208 | VSS — Ground |
Applications typiques
MCF5407CAI220 convient pour 6 applications: Industrial PLC and Factory Automation Controller, Networked Printer and Multi-function Peripheral Controller, Point-of-Sale (POS) Terminal, Industrial Ethernet Node / Edge Gateway, Embedded Web Server and Remote Telemetry Appliance, Telecom Edge Equipment and Protocol Converter.
Industrial PLC and Factory Automation Controller
The MCF5407CAI220 fits industrial PLC and factory automation controllers because its 316 Dhrystone MIPS at 220 MHz provides the deterministic headroom needed for ladder-logic runtime, PID loops, and Modbus/TCP polling. The 32-bit external bus pairs with external SDRAM for program storage while the 4 KB on-chip SRAM keeps critical ISRs deterministic. Dual 10/100 Ethernet MACs enable redundant ring topologies common in factory networks, and the industrial -40C to +85C temperature range matches IEC 61131-2 environmental specs.
Recommandé
Networked Printer and Multi-function Peripheral Controller
The MCF5407CAI220's dual Ethernet MACs and USB 1.1 device make it well-suited as the main controller in networked printers and MFPs. Its ColdFire V4 core handles PCL/PostScript rasterization at up to 316 MIPS, while the SDRAM controller streams large page buffers to the print engine. Industrial temp grade supports the warm interior of laser printers, and the 32-bit external bus easily drives high-resolution display panels and scanner CCDs in compact MFP designs.
Recommandé
Point-of-Sale (POS) Terminal
The MCF5407CAI220 serves POS terminals where 316 MIPS is sufficient to run encrypted payment processing, thermal printer control, and dual Ethernet MACs to separate payment-network traffic from store LAN. Its industrial temperature range tolerates the warm, sometimes sealed enclosures of retail terminals, and ROMless boot from external flash allows secure firmware updates. ColdFire's deterministic interrupt latency keeps barcode scanner response snappy at checkout speed.
Recommandé
Industrial Ethernet Node / Edge Gateway
The MCF5407CAI220's dual 10/100 Ethernet MACs (with MII/RMII), USB 1.1 device, and 316 MIPS ColdFire V4 core make it ideal for industrial Ethernet nodes and protocol-conversion gateways (EtherNet/IP to Modbus TCP, Profibus to Ethernet). The 4 KB on-chip SRAM is enough for tight protocol-stack inner loops, while the 32-bit bus drives external SDRAM for frame buffers. Industrial temperature grade supports DIN-rail mounted installations in unheated control cabinets.
Recommandé
Embedded Web Server and Remote Telemetry Appliance
The MCF5407CAI220 works well as an embedded web/HTTP server in remote telemetry and SCADA appliances, leveraging its ColdFire V4 integer performance to run lightweight TCP/IP stacks and HTTP servers without an OS. Dual Ethernet supports segregated management and fieldbus networks, while USB 1.1 enables local diagnostics. Industrial temperature and ROMless boot from flash allow secure signed firmware updates for unattended deployments.
Recommandé
Telecom Edge Equipment and Protocol Converter
The MCF5407CAI220 fits telecom edge equipment where 316 MIPS, dual Ethernet, and a 32-bit external bus are needed for protocol conversion (SS7 to SIP, RS-232 to TCP). ColdFire V4's deterministic interrupt latency ensures protocol timing is met under load, while ROMless boot from external flash enables carrier-grade firmware validation. Industrial temperature rating is suitable for outdoor telecom cabinets and remote terminal enclosures.
Recommandé
Récapitulatif des produits recommandés
Données de référence d'ingénierie pour MCF5407CAI220 — comparaison, recommandations de conception et informations de conformité.
Guide de sélection
Comparaison avec les alternatives
| Paramètre | Ce produit | MCF5407AFB162 | MCF5407AI162 | MCF5307AI66B | MCF5407CAI162 | MCF5407AFE220 |
|---|---|---|---|---|---|---|
| Package | 208-FQFP (28x28 mm) | 208-FQFP - same | 208-FQFP - same | 208-FQFP - same | 208-FQFP - same | 208-FQFP - same |
| Brand | NXP Semiconductors | NXP Semiconductors | NXP Semiconductors | NXP Semiconductors | NXP Semiconductors | NXP Semiconductors |
| Core | ColdFire V4 | ColdFire V4 | ColdFire V4 | ColdFire V3 | ColdFire V4 | ColdFire V4 |
| Core Clock | 220 MHz | 162 MHz (-26%) | 162 MHz (-26%) | 66 MHz (-70%) | 162 MHz (-26%) | 220 MHz (same) |
| On-chip SRAM | 4 KB | 4 KB | 4 KB | 4 KB | 4 KB | 4 KB |
| Operating Temperature | -40C to +85C (industrial) | -40C to +85C (industrial) | 0C to +70C (commercial) | 0C to +70C (commercial) | -40C to +85C (industrial) | -40C to +85C (industrial) |
| Ethernet MACs | 2x 10/100 | 2x 10/100 | 2x 10/100 | 2x 10/100 | 2x 10/100 | 2x 10/100 |
| Lifecycle | NRND | NRND | NRND | EOL | NRND | NRND |
Principaux différenciateurs
- Highest core clock in the ColdFire 5407 family (vs MCF5407AFB162)
- Industrial temperature grade at 220 MHz (vs MCF5407AI162)
- ColdFire V4 core with branch prediction (vs MCF5307AI66B)
Notes de conception
The 208-FQFP at 28x28 mm requires a 4-layer PCB with continuous ground plane under the part for SDRAM bus signal integrity. Estimated: with 0.5 mm pitch FQFP, route SDRAM traces with 50 ohm controlled impedance, length-matched within 1 cm across all 32 data lines and 13 address lines. Decouple VDD with at least eight 100 nF ceramic capacitors placed within 5 mm of the supply pins, plus one 10 uF bulk capacitor per supply rail.
ROMless operation means the MCF5407CAI220 cannot boot without an external boot ROM or flash on CS0 - a common gotcha when porting firmware from internal-flash microcontrollers. Per the NXP datasheet, configure CS0 for 16-bit wide boot flash at reset, and ensure the RSTOUT line holds reset on peripherals during the PLL lock time (typically 10 ms) to prevent bus contention on power-up.
Estimated: at 220 MHz with both Ethernet MACs active and SDRAM at 133 MHz, the typical core power dissipation is approximately 1.2 W. The 208-FQFP package has no exposed thermal pad, so all heat must be dissipated through PCB copper. Provide at least 4 square inches of 1 oz copper on both top and bottom layers directly under the part, connected by thermal vias to keep junction temperature within the 125 C maximum.
Informations de conformité
RoHS and lead-free compliant per NXP product page. Not AEC-Q100 qualified - this is an industrial-grade MPU, not automotive. Confirm halogen-free status at order time.