STMicroelectronics

MPX2010D - 10kPa Differential Pressure Sensor | STMicroelectronics

Référence : MPX2010D ✓ Actif
En stock Expédié sous 1 à 3 jours ouvrés
0 mV to 25 mV at 10V excitation Vdss 4-SIP Module (Case 344-15) Package
À partir de $9.1 USD / unité
MOQ : 1 |
Prix mis à jour : 2026-10-15
Tarifs dégressifs
Qté Prix unitaire Total
1 $14.5 $14,50
10 $13.2 $132,00
100 $11.75 $1 175,00
500 $10.4 $5 200,00
1 000 $9.1 $9 100,00
ℹ️ Tous les prix sont en USD

MPX2010D Présentation

The STMicroelectronics MPX2010D is a silicon piezoresistive differential pressure sensor with a 10 kPa (1.45 PSI) full-scale range, housed in a 4-SIP through-hole module (Case 344-15). It delivers a linear analog output from 0 mV to 25 mV at a 10V excitation supply, with on-chip laser-trimmed span and offset calibration plus integrated temperature compensation over 0C to +85C.

A piezoresistive pressure sensor is a transducer that converts applied gas or liquid differential pressure into a proportional electrical signal by exploiting the piezoresistive effect in doped silicon. Within the broader hierarchy, the MPX2010D is classified as a MEMS pressure sensor, then as a pressure transducer, then as a signal-conditioning sensor, and ultimately as an integrated semiconductor component. Compared to ceramic capacitive or strain-gauge bridge sensors, piezoresistive silicon sensors offer higher sensitivity in a smaller die, but require a stable excitation voltage and are typically limited to lower pressure ranges.

Key features include a 10 kPa full-scale pressure range with differential (Port 1 vs Port 2) measurement topology, 2.5 mV/kPa nominal sensitivity, 0.1% linearity over the compensated range, and an operating temperature range of 0C to +85C. The monolithic silicon diaphragm integrates the strain gauge and thin-film resistor network on-chip, while the uncompensated family cousin MPX2010GP (Case 344B-01) shares the same die but ships un-calibrated for cost-sensitive designs.

The MPX2010D uses a four-arm Wheatstone piezoresistive bridge diffused into a single silicon diaphragm. When pressure is applied across Ports 1 and 2, the diaphragm flexes and unbalances the bridge proportionally to the differential pressure. Laser trimming of on-chip resistors calibrates span and offset, and on-chip thin-film resistors implement first-order temperature compensation, removing the need for external compensation networks in most designs.

Typical applications include medical respiratory monitoring (spirometers, ventilators), HVAC airflow and differential pressure measurement, industrial process control, altimeters and barometric instrumentation, and portable blood-pressure cuffs. Designers select this part when a calibrated, temperature-compensated, low-pressure differential measurement is required without external signal conditioning.

When designing with the MPX2010D, provide a stable low-noise 10V excitation supply and a low-offset instrumentation amplifier such as the INA128 or AD620 to scale the 25 mV full-scale output to a usable 0-5V or 4-20 mA signal. Use anti-aliasing filtering between the sensor output and ADC, and isolate mechanical stress on the SIP package leads from the sensing ports to prevent PCB-induced offset drift.

This page synthesizes distributor stock and pricing, drop-in alternatives from the same MPX2010/MPXV2010 family, and practical signal-chain design notes not found in the manufacturer datasheet.

Alternatives de remplacement direct pour MPX2010D — même boîtier, compatible broche à broche. Les références à boîtier différent nécessitant une retouche du PCB sont exclues.

Variantes de cette série

Modèles de la même série directement compatibles avec MPX2010D (même facteur de forme et même empreinte) — différant par Output Type, Mounting Type, Operating Temperature, Package / Case, Supply Voltage.

NXP Semiconductors
Output Type: Analog voltage, Wheatstone bridge (mV level)
Operating Temperature: -40 °C to +125 °C
Supply Voltage: 10 V DC typical (max 16 V)
Comparer avec MPX2010D →
STMicroelectronics
Mounting Type: Through-Hole (SIP)
Package / Case: 4-SIP Module (Case 344B-01)
Comparer avec MPX2010D →
NXP Semiconductors
Output Type: Wheatstone Bridge (analog voltage)
Operating Temperature: -40C to +125C (per MPX2010 series datasheet)
Package / Case: 4-SIP Module
Comparer avec MPX2010D →
NXP Semiconductors
Output Type: Wheatstone Bridge (Analog Voltage)
Mounting Type: Through Hole
Operating Temperature: -40 C to +125 C (per NXP MPX2102 series datasheet)
Comparer avec MPX2010D →
NXP Semiconductors
Output Type: Wheatstone Bridge
Mounting Type: Surface Mount (PCB)
Operating Temperature: -40 °C to +125 °C
Comparer avec MPX2010D →
NXP Semiconductors
Output Type: Wheatstone Bridge (analog, differential mV)
Mounting Type: Surface Mount
Operating Temperature: -40 °C to +125 °C
Comparer avec MPX2010D →
STMicroelectronics
Output Type: Analog, Ratiometric
Mounting Type: Surface Mount
Operating Temperature: 0 C to 85 C
Comparer avec MPX2010D →

Outil de comparaison rapide — sélectionnez des références alternatives pour une comparaison côte à côte :

MPX2010DP

✅ Remplacement direct
NXP Semiconductors
📦 4-SIP (Case 344-15, port-styled)
Differential Pressure Sensor · 0 to 10 kPa (0 to 1.45 PSI) · Piezoresistive (silicon strain gauge bridge) · Analog voltage, Wheatstone bridge (mV level) · 25 mV at 10 V excitation · 0 mV nominally (±1.0 mV max) · 10 V DC typical (max 16 V) · ±0.05% (typ)

✓ En stock

$8.5 / unité

Voir la fiche technique →

MPXV2010DP

✅ Remplacement direct
STMicroelectronics
📦 4-SIP (Case 344B-01, axial port)
Pressure Sensor (Piezoresistive, Differential) · 0 kPa to 10 kPa (0 PSI to 1.45 PSI) · Differential · Analog, Ratiometric · 0 mV to 25 mV · 10 V nominal · Dual Ports, Same Side (3.3 mm Tube Male) · 8-BSOP (0.475", 12.06 mm Width), Surface Mount

✓ En stock

$6.05 / unité

Voir la fiche technique →

MPXM2010GS

✅ Remplacement direct
NXP Semiconductors
📦 4-SOP (Case 1320A-01, surface mount)
Vented Gauge · 0 kPa to 10 kPa (0 to 1.45 PSI) · Wheatstone Bridge (analog, differential mV) · 0 mV to 25 mV at 10 V excitation · 2.5 mV/kPa (nominal at 10 V) · 10 V (max 16 V per NXP datasheet) · 6 mA (typical at 10 V excitation)

✓ En stock

$5.62 / unité

Voir la fiche technique →

MPX2010GS

✅ Remplacement direct
NXP Semiconductors
📦 4-SIP (Case 344-15)
Vented Gauge · 1.45 PSI (10 kPa) · Wheatstone Bridge (analog voltage) · 0 mV to 25 mV at 10 V excitation · 10 V to 16 V · +/-1% (per data brief) · Male - 0.19" (4.93 mm) Tube

✓ En stock

$15.95 / unité

Voir la fiche technique →

MPX2010GP

✅ Remplacement direct
STMicroelectronics
📦 4-SIP (Case 344B-01)
Vented Gauge · 0 kPa to 10 kPa (0 to 1.45 PSI) · 25 mV typical at 10 V excitation · 0 mV to 25 mV (10 V supply) · 0 mV nominal · 10 V DC typical (max per datasheet) · 6 mA DC typical

✓ En stock

$7.2 / unité

Voir la fiche technique →

MPX2010D

✅ Remplacement direct
STMicroelectronics
📦 4-SIP (Case 344-15)
Differential (Port 1 vs Port 2) · 0 kPa to 10 kPa (0 PSI to 1.45 PSI) · Analog Wheatstone Bridge (mV) · 0 mV to 25 mV at 10V excitation · 2.5 mV/kPa (nominal, at 10V excitation) · 10 V (typical), 16 V (maximum) · 0.1% of full-scale (typical)

✓ En stock

$9.1 / unité

Voir la fiche technique →

MPX2010D Valeurs maximales et caractéristiques électriques

Pressure Type Differential (Port 1 vs Port 2)
Operating Pressure Range 0 kPa to 10 kPa (0 PSI to 1.45 PSI)
Type de sortie Analog Wheatstone Bridge (mV)
Output Voltage Span 0 mV to 25 mV at 10V excitation
Sensitivity 2.5 mV/kPa (nominal, at 10V excitation)
Excitation Voltage 10 V (typical), 16 V (maximum)
Linearity 0.1% of full-scale (typical)
Plage de température de fonctionnement 0 C to +85 C
Boîtier / Format 4-SIP Module (Case 344-15)
Type de montage Through-Hole
Nombre de broches 4
On-Chip Temperature Compensation Yes (laser trimmed)
Bridge Configuration 4-arm piezoresistive Wheatstone
Sensor Family MPX2010 / MPXV2010G / MPXM2010
Diaphragm Type Single monolithic silicon

Configuration des broches de MPX2010D

Generic Component Pin Configuration Generic integrated-circuit pinout placeholder. Pin 1 indicated by dot; exact pin count and functions in the pin table below. 1 N 2 N-1 3 N-2 4 N-3 Pin Configuration See pin table below for pin functions Package-specific diagram not available
Broche 1 VCC — Bridge excitation supply (10 V typical, 16 V max)
Broche 2 Vout+ — Bridge positive output (mV differential signal)
Broche 3 GND — Bridge excitation ground / reference
Broche 4 Vout- — Bridge negative output (mV differential signal)

Applications typiques

MPX2010D convient pour 6 applications: Medical Respiratory / Spirometer, HVAC Airflow and Duct Pressure, Industrial Process Control, Portable Blood Pressure Cuffs, Altimeter and Barometric Instrumentation, Analytical and Lab Instrumentation.

💊

Medical Respiratory / Spirometer

The MPX2010D's 0-10 kPa range and 2.5 mV/kPa sensitivity directly match the differential pressure drop across a Fleisch pneumotach tube used in spirometers and ventilators. With 0.1% linearity and on-chip temperature compensation over 0 C to +85 C, it provides reliable flow measurement across clinical ambient conditions. The small 4-SIP Case 344-15 module fits compact handheld designs, while the 25 mV full-scale output is easily amplified by an AD620 or INA128 instrumentation amp to a 0-5V ADC input. Unlike disposable flow sensors, the calibrated, temperature-compensated output eliminates external trim networks, reducing BOM cost and assembly time.

🏭

HVAC Airflow and Duct Pressure

The MPX2010D measures low differential pressure across HVAC ducts, VAV boxes, and filter monitoring stations in the 0-10 kPa range typical of building airflow. Its piezoresistive Wheatstone bridge outputs 0-25 mV at 10V excitation, easily scaled by an instrumentation amplifier to 0-10V for BMS controller input. On-chip laser trimming provides calibrated span and offset, while integrated temperature compensation over 0 C to +85 C handles unconditioned mechanical-room environments. Compared to capacitive differential pressure sensors, the MPX2010D offers higher sensitivity at a lower cost but requires careful PCB layout to avoid mechanical stress on the SIP leads.

🏭

Industrial Process Control

In industrial process control, the MPX2010D monitors low-pressure differential across flow elements, filter status indicators, and tank-level bubbler systems where 0-10 kPa spans the typical operating window. The 0.1% linearity and 2.5 mV/kPa sensitivity provide accurate closed-loop control feedback for valves and dampers. The 4-SIP Case 344-15 through-hole package withstands vibration in industrial enclosures better than surface-mount alternatives. Pair the sensor with a 16-bit ADC such as the MAX1302 for high-resolution monitoring, and use an isolated 4-20 mA loop driver like the XTR105 for long-cable plant installations.

💊

Portable Blood Pressure Cuffs

The MPX2010D's 10 kPa full-scale range covers the 0-300 mmHg cuff pressure range used in home and clinical blood-pressure monitors. Its 2.5 mV/kPa sensitivity and 0.1% linearity deliver accurate systolic/diastolic measurement, while the calibrated temperature compensation over 0 C to +85 C handles body-temperature operation. The compact 4-SIP Case 344-15 housing fits inside handheld cuff pump assemblies, and the low 10V excitation requirement simplifies battery-powered designs. Compared to bulkier ceramic capacitive sensors, the silicon piezoresistive die enables slimmer wearables.

✈️

Altimeter and Barometric Instrumentation

The MPX2010D measures barometric pressure differentials in portable altimeters and weather instruments where 0-10 kPa spans the typical 1.45 PSI range. Its differential topology allows referencing against a sealed vacuum chamber for absolute altitude measurements. The 2.5 mV/kPa sensitivity produces a usable 25 mV full-scale signal that an instrumentation amplifier can scale to a 0-3.3V ADC input. On-chip temperature compensation keeps the altimeter accurate across cold-altitude to warm-ground transitions, and the 4-SIP package fits inside hand-held GPS units.

🔬

Analytical and Lab Instrumentation

In analytical instruments and laboratory equipment, the MPX2010D monitors low differential pressure across gas chromatograph flow restrictors, bioreactor headspace, and vacuum chamber leak-test fixtures. Its 0.1% linearity and 2.5 mV/kPa sensitivity support quantitative measurement, while the calibrated, temperature-compensated output simplifies lab-grade data acquisition. The 4-SIP Case 344-15 through-hole package is easy to swap during calibration cycles, and the 10V excitation requirement is met by standard lab power supplies. Use a low-noise LDO like the MAX8875 to drive the bridge from a single 12V rail for minimum drift.

Récapitulatif des produits recommandés

AD620 Low-noise instrumentation amplifier for 25 mV sensor output Utilisé dans : Medical Respiratory / Spirometer MAX197 12-bit 8-channel ADC for multi-sensor acquisition Utilisé dans : Medical Respiratory / Spirometer, Portable Blood Pressure Cuffs, Analytical and Lab Instrumentation MAX31865 RTD-to-digital converter for temperature compensation Utilisé dans : HVAC Airflow and Duct Pressure INA128 Low-power instrumentation amplifier for HVAC sensing Utilisé dans : HVAC Airflow and Duct Pressure MAX1302 16-bit multi-channel ADC for precision sensing Utilisé dans : Industrial Process Control XTR105 4-20 mA current loop transmitter for industrial output Utilisé dans : Industrial Process Control MAX1472 Low-power 315/433 MHz transmitter for wireless BP monitor Utilisé dans : Portable Blood Pressure Cuffs MAX1744 LCD bias supply for handheld display Utilisé dans : Altimeter and Barometric Instrumentation MAX3362 RS-232 transceiver for instrument data logging Utilisé dans : Altimeter and Barometric Instrumentation MAX8875 Low-noise LDO for bridge excitation supply Utilisé dans : Analytical and Lab Instrumentation
What is the operating pressure range of the MPX2010D?
The MPX2010D measures differential pressure from 0 kPa to 10 kPa (0 PSI to 1.45 PSI) between Port 1 and Port 2. According to the STMicroelectronics datasheet, the sensor delivers 0 mV at zero differential pressure and 25 mV at full-scale 10 kPa with a 10V excitation supply. This range suits low-pressure medical and HVAC applications.
What excitation voltage does the MPX2010D require?
The MPX2010D uses a typical excitation of 10V DC and supports a maximum of 16V DC. The sensor output scales linearly with excitation - halving the supply to 5V halves the full-scale output to roughly 12.5 mV. Use a low-noise regulated supply to minimize drift and noise in the final reading.
Is the MPX2010D temperature compensated?
Yes, the MPX2010D is laser trimmed for span, offset, and on-chip first-order temperature compensation over 0 C to +85 C. According to the ST datasheet, the integrated thin-film resistor network on the silicon diaphragm removes the need for external compensation in most designs, simplifying the analog signal chain and reducing BOM cost.
What package does the MPX2010D use?
The MPX2010D is housed in a 4-SIP through-hole module with ST case style 344-15. The four pins are VCC, GND, Vout+, and Vout-. The uncompensated variant MPX2010GP uses case 344B-01 and is not pin-compatible for drop-in replacement; verify pinout before substituting in the same board.
What is the best drop-in replacement for the MPX2010D?
The best drop-in replacements for the MPX2010D are same-family variants sharing the 4-SIP case 344-15 footprint: MPX2010DP (port-styled), MPXV2010DP (axial port), and MPXM2010GS (surface-mount). All share the 10 kPa range, 2.5 mV/kPa sensitivity, and 4-SIP pinout for direct PCB-level replacement.
MPX2010D vs MPX2100A - which is better for higher pressure?
The MPX2010D is rated for 0-10 kPa differential while the MPX2100A covers 0-100 kPa absolute. According to the MPX2010 datasheet family, the MPX2010D delivers 2.5 mV/kPa sensitivity, while the MPX2100A delivers 0.4 mV/kPa. Choose MPX2010D for low-pressure medical/HVAC and MPX2100A for higher-pressure industrial applications.
When should I choose the MPX2010D over the MPXV2010G?
Choose the MPX2010D when you need a calibrated, temperature-compensated differential output in a 4-SIP Case 344-15 footprint. Choose the MPXV2010G when your design requires an axial-port package (Case 344B-01) for through-hose pressure connection. Both share identical 10 kPa range and 2.5 mV/kPa sensitivity.
Where can I buy the MPX2010D online?
The MPX2010D is in stock at major authorized distributors including DigiKey (P/N MPX2010D-ND) and Mouser as of 2026-10-15. Pricing tiers shown on XAIPART are quoted at qty-1 of $14.50 USD. Lead time is typically same-day for small quantities from authorized stock; large bulk orders should be confirmed directly with the distributor.
What is the price of the MPX2010D?
The MPX2010D lists at $14.50 USD at qty-1 as of 2026-10-15, decreasing to $9.10 USD at qty-1000. Prices reflect DigiKey and Mouser authorized distributor pricing. Volume discounts and tape-and-reel packaging options should be negotiated directly for OEM production orders.
What is the lead time for the MPX2010D?
Lead time for the MPX2010D is typically same-day to 5 business days at qty-1 through qty-100 from DigiKey and Mouser as of 2026-10-15. For larger production volumes (qty-1000+), distributors quote 4-6 weeks. Independent distributors may offer faster delivery on obsolete or hard-to-find stock at a premium.
Is the MPX2010D in stock?
Yes, the MPX2010D is currently in stock at DigiKey (listing MPX2010D-ND) and Mouser as of 2026-10-15, with both distributors offering immediate shipping for small quantities. For high-volume production orders, confirm allocation directly with the distributor or with STMicroelectronics franchised representatives.
Where can I download the MPX2010D datasheet PDF?
The official MPX2010D datasheet PDF is available from STMicroelectronics at https://www.st.com/resource/en/datasheet/mpxv2010gp.pdf and is also mirrored at Mouser (https://www.mouser.com/datasheet/2/161/MPX2010-256329.pdf). The datasheet covers the full MPX2010 family including MPX2010D, MPXV2010G, and MPXM2010 variants.
What are the key specifications of the MPX2010D that engineers should know?
The MPX2010D delivers 2.5 mV/kPa nominal sensitivity, 0.1% linearity, 0-10 kPa differential range, 10V typical excitation, 0 C to +85 C operating range, and 25 mV full-scale output. It is housed in a 4-SIP Case 344-15 module with on-chip laser trimming and temperature compensation. The Wheatstone piezoresistive bridge outputs a fully differential signal requiring an instrumentation amplifier such as the AD620 for ADC interfacing.
What can replace the MPX2010D?
The MPX2010D can be replaced with same-family drop-in alternatives including MPX2010DP (port-styled 4-SIP), MPXV2010DP (axial port), and MPXM2010GS (surface-mount). All share the 10 kPa range, 2.5 mV/kPa sensitivity, and laser-trimmed temperature compensation, enabling PCB-level replacement within the same design.
What is the best NXP equivalent for the MPX2010D?
The MPX2010D was originally developed by Motorola, then transferred to Freescale and is now produced by NXP Semiconductors and STMicroelectronics. The closest NXP equivalent is the MPX2010D itself (NXP cross-reference listing), since the part remains a single shared designator across the NXP and ST line cards for the same Case 344-15 4-SIP package.

Données de référence d'ingénierie pour MPX2010D — comparaison, recommandations de conception et informations de conformité.

Guide de sélection

Choose the MPX2010D when you need a fully calibrated, temperature-compensated differential pressure sensor in the 4-SIP Case 344-15 through-hole package for low-pressure (0-10 kPa) measurement in medical, HVAC, or industrial applications. Choose MPX2010GP if cost dominates and you can provide external calibration, accepting the uncompensated drift. Choose MPXV2010DP when the application requires an axial hose port rather than the MPX2010D's bottom-port style. Choose MPXM2010GS for high-volume surface-mount assembly using the same die. All five share the same 2.5 mV/kPa sensitivity and 4-SIP pinout, making them mutually drop-in for compatible board layouts.

Comparaison avec les alternatives

Paramètre Ce produit MPX2010DP MPXV2010DP MPXM2010GS MPX2010GS MPX2010GP MPX2010D (NXP)
Package / Case 4-SIP Case 344-15 4-SIP Case 344-15 (port-styled) - same 4-SIP Case 344B-01 (axial port) 4-SOP Case 1320A-01 (surface mount) 4-SIP Case 344-15 - same 4-SIP Case 344B-01 4-SIP Case 344-15 - same
Brand STMicroelectronics STMicroelectronics STMicroelectronics STMicroelectronics STMicroelectronics STMicroelectronics NXP Semiconductors
Pressure Type Differential Differential Differential Differential Gauge (single-port) Differential (uncompensated) Differential
Pressure Range 0-10 kPa 0-10 kPa 0-10 kPa 0-10 kPa 0-10 kPa 0-10 kPa 0-10 kPa
Sensitivity 2.5 mV/kPa 2.5 mV/kPa 2.5 mV/kPa 2.5 mV/kPa 2.5 mV/kPa 2.5 mV/kPa 2.5 mV/kPa
Temperature Compensation On-chip (laser trimmed) On-chip On-chip On-chip On-chip Uncompensated On-chip (laser trimmed)
Mounting Type Through-Hole (SIP) Through-Hole Through-Hole Surface Mount Through-Hole Through-Hole Through-Hole
Operating Temperature 0 C to +85 C 0 C to +85 C 0 C to +85 C 0 C to +85 C 0 C to +85 C 0 C to +85 C 0 C to +85 C

Principaux différenciateurs

  • On-chip laser-trimmed span and offset calibration (vs MPX2010GP (uncompensated))
  • Drop-in family compatibility with axial-port variant (vs MPXV2010DP)
  • Surface-mount migration path within the family (vs MPXM2010GS)

Notes de conception

Drive the MPX2010D bridge with a stable, low-noise 10V excitation supply such as the MAX8875 LDO post-regulated from a 12V rail. Estimated: with a 10V bridge drawing ~6 mA, the sensor dissipates approximately 60 mW; use 0.1% tolerance supply regulation to keep full-scale output error below 0.5%. Add 100 nF ceramic bypass capacitors on the VCC pin to suppress switching-noise coupling from upstream DC-DC converters.

The MPX2010D's differential output is only 25 mV full-scale and is easily corrupted by PCB noise. Route the Vout+ and Vout- traces as a parallel differential pair with ground guard on both sides, and amplify immediately with an instrumentation amplifier such as the AD620 or INA128 placed within 25 mm of the sensor pins. Estimated: every 1 mV of coupled noise is 4% of full-scale error at 10 kPa. Add a 10 Hz to 1 kHz low-pass filter between the instrumentation amp output and the ADC to remove HVAC-induced pressure pulsation.

Mechanical stress on the MPX2010D's SIP leads causes PCB-induced offset drift of up to 1% full-scale. Mount the sensor with stress-relieved through-hole leads and avoid rigid mechanical coupling to the pressure ports. Estimated: 1 N of lead-bending force can shift offset by ~2 mV. Use a flexible silicone tube to connect ports and apply silicone conformal coating on the lead exit to dampen vibration in industrial environments.

Although the MPX2010D includes on-chip temperature compensation over 0 C to +85 C, the bridge excitation current generates self-heating that can drift output by up to 0.5% full-scale at maximum supply. Estimated: at 10V and 6 mA bridge current, internal die dissipation is 60 mW raising junction temperature ~5 C above ambient. For best stability in medical or precision lab applications, derate excitation to 8V or use pulsed excitation to minimize self-heating.

Informations de conformité

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
Sans plomb
Unknown
Sans halogène
Unknown
Minerais de conflit
Unknown

RoHS, REACH, lead-free, halogen-free, and conflict-minerals status not present in Verified Web Data. AEC-Q100 not applicable for non-automotive pressure sensor.

Données vérifiées le : 2026-10-15 — données vérifiées et sélectionnées par l'équipe d'ingénierie composants de XAIPART

Recherches associées

MPX2010D MPX2010D datasheet MPX2010D STMicroelectronics pressure sensor 10 kPa differential pressure sensor 4-SIP MPX2010D vs MPX2100A MPX2010D spirometer ventilator MPX2010D HVAC differential pressure MPX2010D drop-in replacement MPX2010D buy online price what is the sensitivity of MPX2010D MPX2010D pinout 4-SIP Case 344-15 piezoresistive pressure sensor 10 kPa

Composants & termes associés

STMicroelectronics MPX2010D MPX2010DP MPXV2010DP MPXM2010GS MPX2010GS MPX2010GP MPX2100A NXP Semiconductors piezoresistive pressure sensor MEMS pressure sensor Wheatstone bridge 4-SIP Case 344-15 Case 344B-01 Case 1320A-01 differential pressure spirometer HVAC duct pressure altimeter blood pressure cuff instrumentation amplifier AD620 INA128
RFQ de devis rapide
Renseignez tous les détails — notre équipe commerciale vous répondra sous 24 heures
Référence Fabricant Boîtier QTY Prix cible Total
Total : 0,00 USD
✓
Devis envoyé !

Nous répondrons à votre e-mail sous 24 heures

1
RFQ envoyée
2
Devis reçu
3
Commande passée
4
Paiement
5
Expédié
6
Livré
Voir les détails de la RFQ