TCAN1051VDRQ1 - CAN FD Transceiver, Fault Protected | TI
Référence : TCAN1051VDRQ1 ✓ Actif| Qté | Prix unitaire | Total |
|---|---|---|
| 1 | $0.51 | $0,51 |
| 10 | $0.46 | $4,60 |
| 100 | $0.4 | $40,00 |
| 500 | $0.35 | $175,00 |
| 1 000 | $0.31 | $310,00 |
TCAN1051VDRQ1 Présentation
A CAN (Controller Area Network) transceiver is an interface IC that translates the logic-level TXD and RXD signals of a CAN controller into the differential CANH and CANL bus levels. It sits at the physical layer of the CAN hierarchy - below the CAN controller and microcontroller - and is a critical element of automotive and industrial networking. The "V" suffix in the TCAN1051 family denotes the secondary supply input, allowing direct interfacing with 1.8V, 3.3V, or 5V microcontroller I/O.
Key features include CAN FD support for fast data-phase bit rates, integrated fault protection on the CANH and CANL bus pins, low-power standby mode with wake-up capability, and AEC-Q100 automotive qualification for demanding environments.
On the technical side, the transceiver provides a half-duplex, 1-driver/1-receiver interface to the two-wire CAN bus. The VIO pin thresholds level-shift TXD inputs and RXD outputs, while the STB pin enables silent (listen-only) standby operation, reducing system power in partially-networked nodes. Ground-loss, loss-of-supply, and short-circuit protection keep the device from damaging the bus in fault conditions.
Typical applications include automotive body and powertrain ECUs, electric vehicle battery management systems, industrial automation field buses, and building control networks. In BMS designs the fault protection and wide temperature rating are especially valuable.
Design-wise, place a 100nF decoupling capacitor close to the VCC and VIO pins and terminate the bus with its characteristic impedance (typically 120 ohms) at both ends.
This page adds value beyond the TI datasheet by consolidating distributor pricing, drop-in alternatives from TI and competing vendors, and practical design notes.
Alternatives de remplacement direct pour TCAN1051VDRQ1 — même boîtier, compatible broche à broche. Les références à boîtier différent nécessitant une retouche du PCB sont exclues.
Variantes de cette série
Modèles de la même série directement compatibles avec TCAN1051VDRQ1 (même facteur de forme et même empreinte) — différant par Package, Product Type, Data Rate, Protocol, Operating Temperature.
Outil de comparaison rapide — sélectionnez des références alternatives pour une comparaison côte à côte :
TCAN1051GVDRQ1
✅ Remplacement direct ⚠️ Spécifications non vérifiées✓ En stock
$1.28 / unité
Voir la fiche technique →TCAN1051HVDRQ1
✅ Remplacement direct📋 Alternative de référence (hors catalogue)
TCAN1051GDRQ1
✅ Remplacement direct ⚠️ Spécifications non vérifiées📋 Alternative de référence (hors catalogue)
TJA1051T/3/1
✅ Remplacement direct✓ En stock
$0.4102 / unité
Voir la fiche technique →MCP2561-E/SN
✅ Remplacement direct📋 Alternative de référence (hors catalogue)
TLE7251VSJ
✅ Remplacement direct📋 Alternative de référence (hors catalogue)
TCAN1051VDRQ1 Spécifications
| Product Type | Automotive fault protected CAN FD transceiver |
| Protocol | CAN with Flexible Data-Rate (CAN FD) |
| Number of Drivers/Receivers | 1/1 |
| Duplex | Half duplex |
| I/O Level Shifting | Yes (VIO secondary supply input) |
| Silent Mode | Yes (STB pin, listen-only standby) |
| Fault Protection | Bus fault protected (CANH/CANL) |
| Température de fonctionnement | -55C to +125C |
| Boîtier | SOIC (D), 8 pins |
| Type de montage | Surface Mount |
| Automotive Qualification | AEC-Q100 qualified (Q1) |
| Statut RoHS | Compliant |
| Application Domain | Automotive, industrial CAN networking |
Configuration des broches de TCAN1051VDRQ1
| Broche 1 | TXD — Transmit data input from CAN controller (VIO-referenced levels) |
| Broche 2 | GND — Ground reference |
| Broche 3 | VCC — Transceiver supply voltage |
| Broche 4 | RXD — Receive data output to CAN controller (VIO-referenced levels) |
| Broche 5 | VIO — Secondary supply for I/O level shifting of TXD/RXD |
| Broche 6 | CANL — CAN bus low-level line |
| Broche 7 | CANH — CAN bus high-level line |
| Broche 8 | STB — Standby (silent mode) control input |
Applications typiques
TCAN1051VDRQ1 convient pour 6 applications: Automotive Body and Powertrain ECUs, EV Battery Management Systems (BMS), Industrial Automation Field Bus, CAN Diagnostic Gateways and Data Loggers, Building Control and Elevator Networks, Agricultural and Off-Highway Vehicles.
Automotive Body and Powertrain ECUs
Body control modules, door zones, and powertrain controllers communicate over 500 kbps Classical CAN or CAN FD networks where the TCAN1051VDRQ1 excels. Its AEC-Q100 qualification across -55C to +125C covers under-hood and exterior mounting locations, while integrated fault protection on CANH/CANL keeps a single shorted or grounded node from dragging down the whole bus - a common field failure in harness-damaged vehicles. The VIO supply lets a single transceiver footprint serve both 3.3V and 5V MCU platforms, and the STB pin enables listen-only operation for diagnostic gateways that must observe traffic without driving the bus.
Recommandé
EV Battery Management Systems (BMS)
In electric vehicle battery packs, the TCAN1051VDRQ1 provides the communication link between battery management controllers and cell-monitoring slaves. The high-voltage TCAN1051H variants are preferred at 24V/48V rails, while the standard V version serves 12V-domain BMS masters. Its bus fault protection is essential in packs where wiring harness faults, coolant leaks, or connector corrosion can short the CAN pair to pack potential. The wide -55C to +125C rating covers cell-adjacent mounting, and CAN FD's higher data-phase rate accelerates cell-voltage and temperature polling cycles across dozens of daisy-chained modules, reducing worst-case fault detection latency.
Recommandé
Industrial Automation Field Bus
Factory automation nodes - drives, I/O modules, and sensors - rely on CANopen and similar CAN-based field buses. The TCAN1051VDRQ1's fault protection survives the miswiring and ground-potential differences common in industrial cabinets, and its standby mode helps meet energy-efficiency targets for nodes parked in an idle machine section. The VIO level-shifting supply allows direct connection to modern 3.3V industrial MCUs without level translators, saving board area and BOM cost. CAN FD capability future-proofs the design for higher-throughput motion control traffic where Classical CAN's 8-byte frames and 1 Mbps ceiling become the bottleneck.
Recommandé
CAN Diagnostic Gateways and Data Loggers
Diagnostic gateways and fleet data loggers connect to vehicle CAN buses and must tolerate electrically hostile ports. The TCAN1051VDRQ1's integrated bus fault protection guards against shorted OBD-II cables and aftermarket accessory faults. In listen-only logging applications, the STB pin provides silent mode so the logger never ACKs or disturbs production traffic. The VIO input allows direct interface to 1.8V-3.3V edge-computing loggers, and the wide temperature rating suits loggers taped inside engine bays for extended durability testing campaigns across hot and cold climates.
Recommandé
Building Control and Elevator Networks
Elevator controllers, HVAC controllers, and fire-alarm panels use CAN-based networking over long building runs where the TCAN1051VDRQ1's robust receivers and fault protection maintain communication despite ground potential shifts between floors. Its standby mode suits intermittently powered nodes such as door controllers on standby power. The VIO input simplifies design when panel MCUs range from legacy 5V parts to modern 3.3V controllers on the same PCB platform. CAN FD support accommodates growing telemetry traffic in smart-building retrofits where video and sensor data increasingly share the controller network backbone.
Recommandé
Agricultural and Off-Highway Vehicles
Tractors, harvesters, and construction equipment implement ISOBUS over CAN, exposing connectors to mud, moisture, and implement misconnection. The TCAN1051VDRQ1's fault tolerance handles implement-side shorts and intermittent connector faults that frequently damage unprotected transceivers. The -55C to +125C AEC-Q100 rating survives cold-soak starts and engine-bay heat. Its CAN FD capability aligns with the industry migration toward ISOBUS extensions requiring higher bandwidth for camera and guidance data. The VIO supply eases integration across the mixed 3.3V/5V controller generations found in agricultural electronics platforms.
Recommandé
Récapitulatif des produits recommandés
Données de référence d'ingénierie pour TCAN1051VDRQ1 — comparaison, recommandations de conception et informations de conformité.
Guide de sélection
Comparaison avec les alternatives
| Paramètre | Ce produit | TCAN1051GVDRQ1 | TCAN1051HVDRQ1 | TJA1051T/3 | MCP2561-E/SN |
|---|---|---|---|---|---|
| Package | SOIC-8 (D) | SOIC-8 (D) - same | SOIC-8 (D) - same | SOIC-8 - same footprint | SOIC-8 - same footprint |
| Brand | Texas Instruments | Texas Instruments | Texas Instruments | NXP Semiconductors | Microchip Technology |
| CAN FD Support | Yes (Flexible Data-Rate) | Yes, up to 5 Mbps | Yes (CAN FD) | No (Classical CAN only) | No (Classical CAN only) |
| VIO Level-Shifting Supply | Yes (pin 5) | Yes (pin 5) | Yes (pin 5) | No dedicated VIO pin | Yes (VIO pin) |
| Silent / Standby Mode | Yes (STB pin) | Yes (STB pin) | Yes (STB pin) | No standby pin | STBY pin (standby) |
| Operating Temperature | -55C to +125C | -55C to +125C | -55C to +125C | -40C to +125C | -40C to +125C |
Principaux différenciateurs
- Full CAN FD support with fault protection (vs TJA1051T/3)
- Dedicated VIO level-shifting supply (vs TCAN1051GDRQ1)
- Wider temperature range (vs MCP2561-E/SN)
- Automotive Q1 ordering pedigree (vs TLE7251VSJ)
Notes de conception
Place a 100nF ceramic decoupling capacitor within 2 mm of each supply pin (VCC and VIO) with a solid ground return via to the ground plane. The CANH/CANL traces should be routed as a closely-coupled differential pair with matched lengths, kept away from switching regulator nodes and ignition transients. Terminate the bus at both physical ends with a resistor equal to the cable characteristic impedance (typically 120 ohms); stub length from the transceiver to the trunk should be minimized to preserve signal integrity at CAN FD data-phase rates.
Do not substitute the non-V TCAN1051GDRQ1 on a board where TXD/RXD are driven below 5V logic levels - the G variant lacks the VIO level-shifting supply and its input thresholds are referenced to VCC, causing unreliable TXD recognition with 3.3V or 1.8V controllers. Similarly, when replacing with the NXP TJA1051 or Microchip MCP2561, note that pin 8 functions differ (STB vs STBY vs N.C.) and CAN FD frames are not supported by these Classical CAN parts, which will fail on FD networks.
The transceiver draws load current proportional to bus traffic because the dominant-state driver current flows through the 60-ohm effective termination load. Estimated: with a 5V VCC and typical dominant driver current in the tens-of-mA range, average supply current in a heavily loaded network is dominated by bus activity, not the IC quiescent current. Use standby mode (STB) in nodes that are logically idle to cut system-level consumption; wake-up behavior should be validated against your CAN controller's wake pattern configuration.
Informations de conformité
AEC-Q100 automotive qualification confirmed via TI TCAN1051V-Q1 product page (-55 to 125C, SOIC D package). RoHS/lead-free per standard TI automotive Q1 portfolio; formal certificates available from TI.com.