ADM213ARSZ - 200kbps RS-232 Transceiver | Analog Devices
MPN: ADM213ARSZ ✓ פעילADM213ARSZ סקירה
An RS-232 transceiver is an interface integrated circuit that combines differential line drivers and receivers for serial data communication. It belongs to the EIA-232-E and V.28 interface hierarchy, translating between CMOS logic levels and the voltage levels used by RS-232 links. The ADM2xx family is intended for equipment where conventional ±12 V supplies are unavailable, making a single 5 V rail practical for modern embedded systems.
Key features include operation with external capacitors from 0.1 µF to 10 µF, a maximum data rate of 200 kbps, low-power shutdown, and receiver operation to ±30 V. Two receivers remain active in shutdown, allowing selected incoming signals to be monitored without keeping every receiver active. The integrated charge-pump converters provide approximately ±9 V transmitter swings, reducing the need for external negative-voltage generation.
The ADM213 combines four transmit channels with five receive channels in one package. Its shutdown and enable controls support systems that need to reduce power consumption when a serial link is inactive. The two shutdown-active receivers are especially useful where a modem, industrial terminal, or data acquisition system must detect an incoming activity or control indication while the main interface is powered down.
Typical uses include industrial serial consoles, instrumentation, point-of-sale equipment, security systems, test systems, and embedded control boards. The ±30 V receiver tolerance provides protection against higher-voltage RS-232 sources, while the integrated converters allow operation from a single 5 V supply. Designers should still protect the physical interface against surge, ESD, and cable transients according to the application environment.
The main design consideration is charge-pump capacitor selection. The ADM213 supports a broad external-capacitor range, but the selected capacitors, wiring, and voltage ratings must satisfy the Analog Devices datasheet requirements. Place the charge-pump and interface capacitors close to their associated pins, preserve a continuous ground return, and validate the implemented layout against the manufacturer's application guidance.
This technical overview combines the device's interface architecture, shutdown behavior, package constraints, and practical RS-232 design considerations into an engineering-focused guide. It also identifies pin-compatible alternatives and highlights the parameter checks required before replacing an existing ADM213ARSZ in production equipment.
חלופות תחליף ישיר עבור ADM213ARSZ — אותו מארז, תואם פין-לפין. חלקים במארז שונה הדורשים עיבוד מחדש של ה-PCB אינם נכללים.
וריאנטים בסדרה זו
דגמים מאותה סדרה התואמים Drop-in עם ADM213ARSZ (אותו גורם צורה וטביעת רגל) — שונים ב Package, Product Type, Supply Voltage, Enable Control, Maximum Data Rate.
ADM211ARSZ
✅ Drop-Inצור קשר לקבלת מחיר
הצג גיליון נתונים ←ADM211EARSZ
✅ Drop-In📋 חלופה להתייחסות (לא בקטלוג)
ADM213EARZ
✅ Drop-Inצור קשר לקבלת מחיר
הצג גיליון נתונים ←MAX213ECAI+T
✅ Drop-In📋 חלופה להתייחסות (לא בקטלוג)
HIN213ECAZ
✅ Drop-In📋 חלופה להתייחסות (לא בקטלוג)
ADM213ARSZ מפרטים
| Product Type | RS-232 line driver/receiver transceiver |
| מתח אספקה | 5 V |
| Maximum Data Rate | 200 kbps |
| Number of Drivers | 4 |
| Number of Receivers | 5 |
| Receivers Active in Shutdown | 2 |
| Transmitter Output Swing | Approximately ±9 V |
| Receiver Input Voltage Tolerance | ±30 V |
| External Capacitor Range | 0.1 µF to 10 µF |
| Low-Power Shutdown Power | ≤5 µW |
| Low-Power Rating | 15 mW |
| Shutdown Control | Yes |
| Enable Control | Yes |
| מארז | 28-pin SSOP |
| סוג הרכבה | Surface mount |
| Device Function | 4 transmitters and 5 receivers |
| Interface Standards | EIA-232-E and V.28 |
| סטטוס RoHS | Compliant |
מדריך תצורת פינים של ADM213ARSZ 28-pin ssop
תצורת פינים עבור ADM213ARSZ (מארזת 28-pin ssop). מספרי פינים, פונקציות ותרשימי חיבורים מוגדרים ב-Datasheet של היצרן. יש לעיין בו לקבלת ה-footprint המדויק והנחיות הלחמה.
אין נתוני פריסת פינים מפורטים עבור ADM213ARSZ.
עיינו ב- גיליון נתונים עבור תצורת פינים מלאה.
יישומים טיפוסיים
ADM213ARSZ מתאים עבור 6 יישוםs: Industrial Serial Console Interface, Point-of-Sale Terminal Equipment, Test and Measurement Equipment, Security and Surveillance Systems, Embedded Data Acquisition Systems, Instrumentation and Process Control.
Industrial Serial Console Interface
The ADM213ARSZ fits industrial consoles and service ports that require a single 5 V supply and four RS-232 transmit channels. Its four drivers, five receivers, and 200 kbps maximum data rate provide adequate margin for configuration transfer, diagnostics, and supervisory commands. The integrated DC-to-DC converters produce approximately ±9 V transmitter swings without requiring a separate negative-voltage rail. In the enclosure, place the charge-pump capacitors close to the IC and keep the connector return path continuous to reduce susceptibility to ground potential differences between connected equipment.
מומלץ
Point-of-Sale Terminal Equipment
The ADM213ARSZ can support point-of-sale terminals, receipt printers, scanners, and payment accessories that exchange data over RS-232. Four transmitters allow a terminal to connect several peripherals while five receivers provide broader input capacity, including monitoring of active signals during shutdown. Operation from one 5 V rail simplifies the power architecture in compact systems. The principal design consideration is ensuring that each transmitter and receiver is assigned to the correct peripheral and that cable transients are controlled through suitable external protection.
מומלץ
Test and Measurement Equipment
The ADM213ARSZ is suitable for laboratory and field-test equipment that must offer several RS-232 ports for legacy instruments. A maximum data rate of 200 kbps covers typical serial command and measurement-data traffic, while receiver tolerance to ±30 V improves compatibility with externally powered equipment. Two receivers active in shutdown can monitor control or alert lines while reducing overall power use. Engineers should evaluate grounding, isolate cable paths where necessary, and include protection appropriate to the maximum expected industrial voltage transient.
מומלץ
Security and Surveillance Systems
The ADM213ARSZ can connect access-control readers, cameras, alarm panels, and configuration tools using RS-232 links. Its shutdown mode and two always-active receivers help systems conserve power while preserving selected status monitoring functions. The 5 V supply, approximately ±9 V output swing, and integrated converters simplify implementation in compact control cabinets. Deployment near outdoor cables requires careful surge and ESD protection; the IC's ±30 V receiver tolerance should not be treated as a substitute for a properly engineered protection network.
מומלץ
Embedded Data Acquisition Systems
The ADM213ARSZ fits embedded acquisition and control units that need multiple legacy RS-232 channels alongside a modern 5 V supply. Four drivers can support multiple command outputs, while five receivers provide additional monitoring inputs and two remain active during shutdown. The 200 kbps capability is useful for sensor-controller traffic and equipment configuration. Layout quality is particularly important because the on-board charge pumps and RS-232 outputs share a compact 28-pin SSOP footprint, so short capacitor connections and controlled ground return paths help maintain predictable behavior.
מומלץ
Instrumentation and Process Control
The ADM213ARSZ can bridge a 5 V control board to RS-232 instruments, analyzers, and programmable laboratory devices. Its four drivers and five receivers support multiple signal paths, while the shutdown function reduces consumption when the instrument is idle. Two receivers active in shutdown allow a controller to detect external status indications without enabling the complete transceiver. For process-control installations, connect the interface reference to the system ground using an appropriate strategy and verify noise, isolation, and surge requirements for the connected cable length.
מומלץ
סיכום מוצרים מומלצים
נתוני עזר הנדסיים עבור ADM213ARSZ — השוואה, הנחיות תכנון ומידע על תאימות.
מדריך בחירה
השוואה עם חלופות
| פרמטר | מוצר זה | ADM211ARSZ | ADM211EARSZ | ADM213EARZ | MAX213ECAI+T | HIN213ECAZ |
|---|---|---|---|---|---|---|
| Package | 28-pin SSOP | 28-pin SSOP | 28-pin SSOP | 28-pin SSOP | 28-pin SSOP | 28-pin SSOP |
| Brand | Analog Devices | Analog Devices | Analog Devices | Analog Devices | Maxim Integrated | Renesas Electronics |
| Shutdown Control | Yes | Yes | Yes | Yes | Yes | Yes |
מבדילים עיקריים
- Two receivers remain active during low-power shutdown (לעומתMAX213ECAI+T)
- Four transmitters and five receivers in one 28-pin SSOP (לעומתHIN213ECAZ)
- Single 5 V rail with integrated approximately ±9 V transmitter swings (לעומתADM211EARSZ)
- RS-232 receiver tolerance extends to ±30 V (לעומתMAX213ECAI+T)
הערות תכנון
Place the ADM213ARSZ charge-pump capacitors close to the pins designated in the manufacturer datasheet. Keep each capacitor's connection to ground short and use a common ground plane that remains continuous beneath the interface section. The permitted external-capacitor range is broad at 0.1 µF to 10 µF, but the exact values, tolerance, dielectric, and voltage rating should follow the datasheet configuration selected for the intended data rate.
Route the RS-232 connector side of the circuit away from sensitive analog and high-speed digital traces. Maintain a low-impedance signal-ground path between the transceiver and connector, and connect the interface reference to the chassis or system ground according to the installation's grounding strategy. A common failure mode in multi-equipment systems is a ground-potential difference that appears as a receiver fault rather than a logic error.
Do not rely on the ADM213ARSZ's ±30 V receiver tolerance as a complete surge-protection solution. External protection may still be required for long cables, outdoor installations, or poorly grounded industrial environments. Also verify shutdown polarity, enable polarity, and which two receivers remain active before replacing the device because a mechanically compatible package does not by itself prove identical control behavior.
Provide a stable 5 V rail and decouple it close to the device supply pins using the capacitance and ESR requirements stated in the manufacturer datasheet. The ADM213 contains charge-pump converters for approximately ±9 V transmitter swings, so bypassing and grounding directly affect the interface's output behavior. Avoid routing charge-pump current through shared narrow traces or split grounds that increase transmitter-to-receiver ground noise.
מידע על תאימות
The LCSC product listing identifies the ADM213ARSZ as RoHS compliant. No additional REACH, lead-free, halogen-free, AEC-Q100, or conflict-minerals status is established.