CD4040BM - 12-Bit CMOS Binary Counter | Texas Instruments
MPN: CD4040BM ✓ פעילCD4040BM סקירה
A binary counter is a sequential logic circuit that records the number of applied clock events and presents that count through digital outputs. A ripple-carry counter advances through its stages sequentially, while a divider derives a lower-frequency clock by selecting a corresponding output stage. Within the broader logic hierarchy, the CD4040BM belongs to the CMOS counter family, falls under counter and divider logic, and ultimately operates as a general-purpose digital semiconductor.
The CD4040BM combines a 12-bit counting section with a separate clock input and an asynchronous master reset. Its negative-edge counting behavior means the displayed count changes when the active clock transitions from high to low. The device is designed for a 3 V to 18 V supply, allowing operation from conventional 5 V systems through higher-voltage industrial interfaces. Its 24 MHz maximum operating frequency provides useful timing margin for divide-by-2 through divide-by-4096 clock-generation systems.
Ripple-carry implementation favors a straightforward architecture with 12 available count outputs. At lower division ratios, the delay between adjacent stages can affect timing, so designers should account for cumulative propagation delay when driving multiple clocks from the outputs. The clock inputs also provide a choice between the main clock terminal and an independent clock-input terminal for common counter configurations. An active-high master reset clears the count for initialization and repeatable sequencing.
Typical applications include programmable timers, digital frequency dividers, pulse and delay generation, industrial sequence controllers, and laboratory test equipment. The 12 output stages can divide a periodic input by powers of two, making the part especially useful when a clean, integer-ratio clock is required. The 16-SOIC package supports conventional surface-mount assembly while providing enough pins for the count outputs, supply rails, clock sources, and reset control.
When laying out a circuit, place the reset and clock traces away from the Q0 through Q11 output nets, provide a stable local supply connection, and maintain compatible logic levels between the driver and counter. Designers should check maximum clock frequency at the actual supply voltage because operating speed and supply voltage are related. The counter should also be reset before enabling a new counting sequence when deterministic starting state is required.
This product page consolidates the manufacturer identification, package information, operating limits, functional characteristics, application guidance, cross-reference findings, and practical design considerations into an engineering-focused selection resource for counters and dividers.
חלופות תחליף ישיר עבור CD4040BM — אותו מארז, תואם פין-לפין. חלקים במארז שונה הדורשים עיבוד מחדש של ה-PCB אינם נכללים.
וריאנטים בסדרה זו
דגמים מאותה סדרה התואמים Drop-in עם CD4040BM (אותו גורם צורה וטביעת רגל) — שונים ב Counter Type, Logic Family, Mounting Type, Package.
SN74LV4040AD
✅ Drop-In📋 חלופה להתייחסות (לא בקטלוג)
CD4040BM דירוגים מרביים ומאפיינים חשמליים
| Counter Type | Binary counter and divider |
| Architecture | Ripple-carry |
| Number of Counter Elements | 1 element |
| Number of Stages | 12 stages |
| Counting Width | 12 bit |
| Counting Edge | Negative edge |
| Supply Voltage Range | 3 V to 18 V |
| תדר שעון מקסימלי | 24 MHz |
| Logic Family | CMOS |
| מארז | 16-pin SOIC |
| סוג הרכבה | Surface mount |
| Master Reset | Asynchronous reset |
| Counter Outputs | 12 outputs, Q0 through Q11 |
| Clock Inputs | 2 clock inputs |
תצורת פינים של CD4040BM
| פין 1 | CLK — Main clock input |
| פין 2 | CLK IN — Independent clock input |
| פין 3 | CLR — Asynchronous counter clear input |
| פין 4 | Q0 — Counter output Q0 |
| פין 5 | Q1 — Counter output Q1 |
| פין 6 | Q2 — Counter output Q2 |
| פין 7 | Q3 — Counter output Q3 |
| פין 8 | VSS — Ground reference |
| פין 9 | Q9 — Counter output Q9 |
| פין 10 | Q8 — Counter output Q8 |
| פין 11 | Q7 — Counter output Q7 |
| פין 12 | Q6 — Counter output Q6 |
| פין 13 | Q5 — Counter output Q5 |
| פין 14 | Q4 — Counter output Q4 |
| פין 15 | VDD — Positive power supply |
| פין 16 | MR — Master reset input |
יישומים טיפוסיים
CD4040BM מתאים עבור 6 יישוםs: Programmable Clock Divider, Industrial Sequence Controller, Pulse and Delay Generator, Frequency Measurement Divider, Digital Control State Sequencer, Test and Measurement Timing Base.
Programmable Clock Divider
The CD4040BM is suitable for generating divided clock signals in timer, pulse-generation, and digital-control systems. Its 12 ripple-carry stages provide power-of-two division ratios, allowing Q0 through Q11 to support divide-by-2 through divide-by-4096 outputs from one input clock. With a 3 V to 18 V supply range and operation up to 24 MHz, the device supports both 5 V and higher-voltage logic systems. The counter advances on the negative clock edge and can be initialized with its asynchronous master reset. When using a high-order output, verify the cumulative ripple delay against downstream setup and hold requirements rather than relying only on the 24 MHz input-frequency limit.
מומלץ
Industrial Sequence Controller
The CD4040BM can provide a compact sequential timing element for industrial control boards that divide an incoming event clock and derive multiple time or phase slots. Its 12 count outputs expose successive power-of-two intervals, while asynchronous master reset returns the sequence to a known state. The 3 V to 18 V operating range permits use with systems operating at 5 V and compatible higher-voltage interfaces. For industrial deployment, keep clock and reset traces short, bypass the supply locally, and confirm the exact device temperature rating and qualification status. The ripple-carry architecture is practical for low-to-moderate frequency sequencing but requires timing checks when several stages feed time-critical circuitry.
מומלץ
Pulse and Delay Generator
The CD4040BM can divide a repetitive pulse train into longer intervals for retriggerable timers, delay stages, and periodic event generators. Selecting Q5, for example, creates a substantially longer interval than Q0 while retaining an integer relationship to the source clock. Negative-edge counting and the independent clock-input terminal provide flexibility in how the source clock is connected. The maximum operating frequency of 24 MHz leaves useful headroom below the input limit, but propagation delay through multiple ripple stages determines when the selected output changes. Reset the counter before each intended measurement sequence when an exact zero-count starting state is required, and validate timing across the complete operating supply range.
מומלץ
Frequency Measurement Divider
The CD4040BM is useful as a range-extension divider ahead of slower counting or display circuitry in a frequency-measurement instrument. Dividing the input by a selected power of two reduces the frequency presented to downstream logic, making 12 count outputs available for different measurement ranges. Its CMOS implementation operates from 3 V to 18 V and supports input frequencies up to 24 MHz, covering many low- and mid-frequency signal sources. The main design constraint is accumulated ripple delay: a higher-order output transitions later than lower-order outputs. Use a clean, low-jitter reference clock, provide local supply bypassing, and compare the selected division ratio with the acquisition time required by the downstream measurement system.
מומלץ
Digital Control State Sequencer
The CD4040BM can act as a state counter in control logic that advances through successive binary states on each clock event. The 12 outputs provide visibility into multiple state boundaries, allowing gates or data selectors to produce predictable step sequences. An asynchronous reset gives the controller a defined startup state and supports repeatable test cycles. The device's 16-pin SOIC package is convenient for conventional PCB assembly, while the 3 V to 18 V range supports several logic-voltage environments. Designers should ensure that only one clock-transition path drives the selected input, observe setup and hold timing around reset, and avoid treating simultaneously changing ripple outputs as glitch-free if a downstream latch requires simultaneous data updates.
מומלץ
Test and Measurement Timing Base
The CD4040BM can serve as a divide-down element in bench instruments that require a stable timing reference derived from a higher-frequency oscillator. The 12 available outputs make it possible to select a convenient integer division ratio while keeping the source oscillator isolated from slower measurement logic. Operation up to 24 MHz and a 3 V to 18 V supply range support common laboratory clock architectures. The input oscillator should have low jitter and clean transitions because the divided output inherits timing uncertainty from the source. A local bypass capacitor and short clock route reduce supply noise and reflections. Before using the counter as a precision time base, evaluate propagation delay, reset behavior, and temperature-dependent timing across the complete measurement range.
מומלץ
סיכום מוצרים מומלצים
נתוני עזר הנדסיים עבור CD4040BM — השוואה, הנחיות תכנון ומידע על תאימות.
מדריך בחירה
השוואה עם חלופות
| פרמטר | מוצר זה | SN74LV4040AD |
|---|---|---|
| Brand | Texas Instruments | Texas Instruments |
| Package | SOIC-16 | SOIC-16 |
| Counter Function | 12-stage ripple-carry binary counter and divider | 12-stage ripple-carry binary counter and divider |
| Counting Width | 12 bit | 12 bit |
| Counting Edge | Negative edge | Negative edge |
| Logic Family | CD4000 CMOS | SN74LV low-voltage CMOS |
מבדילים עיקריים
- Broader CD4000-family supply-voltage range (לעומתSN74LV4040AD)
- Twelve individually available division stages (לעומתSN74LV4040AD)
- 24 MHz maximum operating frequency (לעומתSN74LV4040AD)
הערות תכנון
Treat the CD4040BM as a ripple-carry counter rather than a synchronous counter. Each output stage changes after the preceding stage, so Q11 can transition substantially later than Q0. Route clock and reset signals away from the Q0 through Q11 outputs, terminate unused inputs according to the manufacturer truth table, and verify downstream setup and hold timing using the worst-case propagation delay at the selected supply voltage.
Place the device close to its clock source and place a local bypass capacitor between VDD and VSS at the package. Keep the clock path short and free of test pads or long branches that can add capacitance and ringing. The reset net should also be short and driven with a clean logic signal because a slow or noisy reset transition can cause inconsistent clearing in a sequential timing circuit.
Do not assume every output changes at the same instant. The 12-bit ripple structure produces staggered transitions, which can create transient decode errors if multiple outputs feed combinational decoding logic. Use qualified latch or flip-flop stages where decoded states must be atomic, and confirm that the clock waveform meets the required edge shape. Also verify the alternative device's supply range and logic thresholds before replacing CD4040BM.
מידע על תאימות
No explicit environmental or automotive compliance statements were identified. Confirm current compliance and qualification status with the manufacturer before production release.