INA133UG4 - 1.5MHz Precision Differential Amplifier | Texas Instruments
MPN: INA133UG4 ✓ פעילINA133UG4 סקירה
A precision difference amplifier is an amplifier subtype that subtracts two input voltages and amplifies the resulting differential signal. This measurement-focused category belongs to the hierarchy of instrumentation amplifiers, differential amplifiers, analog amplifiers, and semiconductor signal-conditioning ICs. Unlike a general-purpose operational amplifier configured with external resistors, the INA133 integrates matched internal resistors, reducing component count and improving resistance matching for bridge, shunt, and current-sense measurements.
The INA133UG4 operates from 4.5 V to 36 V and supports output swings of approximately ±2.25 V to ±18 V, depending on supply voltage. Its 5 V/µs slew rate supports accurate reproduction of rapidly changing signals, while low power consumption of 0.95 mA suits battery-powered and portable instrumentation. The manufacturer identifies the device as a precision, low-power, high-performance difference amplifier.
Internally, the INA133 combines four precision resistors with an operational-amplifier core to establish a fixed differential gain of 1. This architecture is useful when the desired output equals the difference between two input voltages, particularly for current measurement across a low-value shunt. Because it is a fixed-gain device, it avoids the gain-setting resistor network and feedback balance adjustments normally required by discrete difference-amplifier implementations.
Typical uses include industrial current sensing, bridge-transducer excitation and readout, battery monitoring, laboratory measurement systems, and instrumentation interfaces that must reject large common-mode voltage. The wide 36 V maximum supply voltage also permits operation from protected industrial rails, although the selected output range must remain within the power-supply limits.
The primary design consideration is common-mode range. Neither input should exceed the supply rails by more than the device permits, and the output must remain within its allowable swing. PCB layout should minimize differential-loop area, use a solid ground reference, and keep input and output return paths separated to reduce errors caused by parasitic resistance or ground gradients.
This page combines manufacturer specifications, package information, application guidance, comparison parameters, and practical design notes to support faster component selection and implementation of the INA133UG4 in precision analog signal chains.
חלופות תחליף ישיר עבור INA133UG4 — אותו מארז, תואם פין-לפין. חלקים במארז שונה הדורשים עיבוד מחדש של ה-PCB אינם נכללים.
וריאנטים בסדרה זו
דגמים מאותה סדרה התואמים Drop-in עם INA133UG4 (אותו גורם צורה וטביעת רגל) — שונים ב Package, Product Type, Operating Temperature Range, RoHS Status, Gain.
INA133U
✅ Drop-In ⚠️ מפרטים לא מאומתיםצור קשר לקבלת מחיר
הצג גיליון נתונים ←INA133UA
✅ Drop-In ⚠️ מפרטים לא מאומתיםצור קשר לקבלת מחיר
הצג גיליון נתונים ←INA132UA
✅ Drop-In ⚠️ מפרטים לא מאומתיםצור קשר לקבלת מחיר
הצג גיליון נתונים ←INA132UG4
✅ Drop-In ⚠️ מפרטים לא מאומתים📋 חלופה להתייחסות (לא בקטלוג)
INA133UG4 דירוגים מרביים ומאפיינים חשמליים
| Product Type | Precision difference amplifier |
| Number of Circuits | 1 circuit |
| -3 dB Bandwidth | 1.5 MHz |
| Slew Rate | 5 V/µs |
| Input Offset Voltage | 150 µV minimum; 450 µV maximum |
| זרם מנוחה | 950 µA |
| Supply Voltage Range | 4.5 V to 36 V |
| טווח מתח פלט | ±2.25 V to ±18 V |
| Differential Gain | 1 V/V |
| מארז | 8-SOIC (0.154 inch, 3.90 mm width) |
| סוג הרכבה | Surface mount |
| סטטוס RoHS | Compliant |
מדריך תצורת פינים של INA133UG4 8-soic (0.154 inch, 3.90 mm width)
תצורת פינים עבור INA133UG4 (מארזת 8-soic (0.154 inch, 3.90 mm width)). רכיב אנלוגי זה כולל פיני כניסה, יציאה ואספקת מתח. יש לעיין בגיליון הנתונים של היצרן לתצורות פיני איפוס היסט, פיצוי והפעלה. אידיאלי למעגלי עיצוב אותות ומגברים.
אין נתוני פריסת פינים מפורטים עבור INA133UG4.
עיינו ב- גיליון נתונים עבור תצורת פינים מלאה.
יישומים טיפוסיים
INA133UG4 מתאים עבור 6 יישוםs: Industrial Shunt Current Sensing, Bridge Transducer Readout, Battery Pack Monitoring, Laboratory Instrumentation, Power Converter Feedback, Portable Sensor Interfaces.
Industrial Shunt Current Sensing
The INA133UG4 fits high-side and low-side shunt-current measurement because its fixed 1 V/V gain converts the differential voltage across a shunt into a single-ended output. Its 450 µV maximum input offset voltage limits the output error attributable to input offset, while the 1.5 MHz bandwidth and 5 V/µs slew rate support changing current waveforms. The 4.5 V to 36 V supply range accommodates industrial rails, but the shunt voltage must remain inside the permitted input common-mode range. Place the amplifier close to the shunt to minimize pickup from adjacent power stages.
מומלץ
Bridge Transducer Readout
For resistive-bridge measurement, the INA133UG4 provides a fixed 1 V/V differential gain and rejects common-mode excitation voltage before the signal reaches the next conversion stage. Its 450 µV maximum input offset and 1.5 MHz bandwidth are useful for medium-speed pressure, load, and position bridges. The 8-SOIC layout also supports compact analog boards. Input filtering should be balanced across both sides of the bridge, and the amplifier must remain within its specified common-mode range as the bridge output changes.
מומלץ
Battery Pack Monitoring
INA133UG4 is suitable for monitoring differential cell or pack voltages when the signal can be observed with a fixed 1 V/V gain. Its low 950 µA quiescent current helps limit continuous overhead in portable or energy-storage monitoring systems, while the 36 V maximum supply voltage accommodates higher-energy cells and protected rails. Its 5 V/µs slew rate also permits measurement of rapid transients. The monitoring architecture must keep the input common-mode voltage within the device limits and avoid placing the amplifier in a measurement path that exceeds its supply rating.
מומלץ
Laboratory Instrumentation
The INA133UG4 can condition differential sensor outputs in compact laboratory instruments where fixed gain, low offset, and fast settling are useful. Its 1.5 MHz bandwidth is sufficient for many pressure, force, strain, and general-purpose analog measurement channels, while the 5 V/µs slew rate limits distortion on larger output steps. The 8-SOIC package simplifies board-level assembly and allows direct replacement within the INA133 family. For best results, use a low-noise reference and ground plane, and verify the input filtering needed to suppress interference at the measured bandwidth.
מומלץ
Power Converter Feedback
INA133UG4 can monitor a differential feedback voltage in a power-conversion or distributed-power system when the operating voltages remain within its 4.5 V to 36 V supply and common-mode limits. Its 1 V/V gain provides a direct representation of the sensed differential voltage, and the 950 µA quiescent current reduces continuous overhead compared with many higher-current instrumentation stages. The 1.5 MHz bandwidth supports feedback paths with moderate dynamics. Designers should compensate the amplifier delay and slew behavior in the control loop and maintain separate power and signal grounds to avoid injecting switching noise into the measurement.
מומלץ
Portable Sensor Interfaces
For portable sensor interfaces, the INA133UG4 combines a 950 µA quiescent current with a precision 150 µV minimum input offset voltage and a 1.5 MHz bandwidth. This combination allows a differential sensor output to be conditioned without the external gain-setting network of a discrete difference amplifier. The compact 8-SOIC package supports space-constrained boards, and the 4.5 V minimum supply supports low-voltage systems. Battery life depends on the complete signal chain, so power-gating or shutdown strategies should be evaluated around the amplifier rather than inferred from its quiescent current alone.
מומלץ
סיכום מוצרים מומלצים
נתוני עזר הנדסיים עבור INA133UG4 — השוואה, הנחיות תכנון ומידע על תאימות.
מדריך בחירה
השוואה עם חלופות
| פרמטר | מוצר זה | INA133U | INA133UA | INA132UA | INA132UG4 |
|---|---|---|---|---|---|
| Brand | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments |
| Package | 8-SOIC | 8-SOIC - same | 8-SOIC - same | 8-SOIC - same | 8-SOIC - same |
| -3 dB Bandwidth | 1.5 MHz | 1.5 MHz | 1.5 MHz | Approximately 1.3 MHz | Approximately 1.3 MHz |
| Differential Gain | 1 V/V | 1 V/V | 1 V/V | 1 V/V | 1 V/V |
| Special Features | Low-power, high-precision fixed-gain difference amplifier | Same INA133 electrical family | Same INA133 electrical family | Related INA132 fixed-gain difference amplifier | Related INA132 fixed-gain difference amplifier |
מבדילים עיקריים
- Higher bandwidth than the directly related INA132 options (לעומתINA132UA)
- Low 950 µA supply current for precision signal conditioning (לעומתINA132UA)
- Exact family compatibility for pin-compatible reuse (לעומתINA133U)
הערות תכנון
Check the input common-mode range and output swing against the actual shunt, bridge, or sensor voltages before committing the circuit. The INA133UG4 accepts a 4.5 V to 36 V supply, but that supply rating does not permit arbitrary input or output excursions. A common design error is to assume that the output can reach a supply rail. Derive the maximum expected input differential voltage, common-mode voltage, and output swing, then include startup and fault-state margin in the design.
Place the INA133UG4 close to the sensed element and route the two input conductors as a compact differential pair over a continuous ground plane. Minimize shared copper in the input path because parasitic resistance in series with the high-impedance inputs can create gain errors. Keep the output route separate from the input pair, use a solid reference plane, and place any input filtering capacitors symmetrically so their tolerances and parasitics do not unbalance the measured signal.
Use the 1.5 MHz -3 dB bandwidth and 5 V/µs slew rate to determine whether the measurement bandwidth is adequate. Avoid excessive low-frequency filtering unless it is required for noise control, because high-value input and filter capacitors can interact with the amplifier's input bias current and introduce errors. Conversely, unfiltered high-frequency pickup can corrupt a low-rate measurement even when the sensor changes slowly. Establish the required signal bandwidth, then design the filter around that bandwidth.
Estimated: with a 5 V supply, 950 µA quiescent current, and no additional output current, the amplifier's nominal supply-power dissipation is 4.75 mW using Pd = VIN × IQ. This estimate excludes load current and regulator-conversion effects. Thermal stress is therefore normally modest in the specified operating region, but the complete board still needs airflow and copper-area checks under maximum ambient temperature, especially when the INA133UG4 drives a nearby load or shares a package region with other heat sources.
מידע על תאימות
The INA133UG4 product record identifies RoHS compliance. Other environmental, automotive, halogen-free, and conflict-minerals declarations require confirmation from the manufacturer or an authoritative compliance document.