INA133UG4 - 1.5MHz Precision Differential Amplifier | Texas Instruments
料号: INA133UG4 ✓ 量产中INA133UG4 概述
A precision difference amplifier is an amplifier subtype that subtracts two input voltages and amplifies the resulting differential signal. This measurement-focused category belongs to the hierarchy of instrumentation amplifiers, differential amplifiers, analog amplifiers, and semiconductor signal-conditioning ICs. Unlike a general-purpose operational amplifier configured with external resistors, the INA133 integrates matched internal resistors, reducing component count and improving resistance matching for bridge, shunt, and current-sense measurements.
The INA133UG4 operates from 4.5 V to 36 V and supports output swings of approximately ±2.25 V to ±18 V, depending on supply voltage. Its 5 V/µs slew rate supports accurate reproduction of rapidly changing signals, while low power consumption of 0.95 mA suits battery-powered and portable instrumentation. The manufacturer identifies the device as a precision, low-power, high-performance difference amplifier.
Internally, the INA133 combines four precision resistors with an operational-amplifier core to establish a fixed differential gain of 1. This architecture is useful when the desired output equals the difference between two input voltages, particularly for current measurement across a low-value shunt. Because it is a fixed-gain device, it avoids the gain-setting resistor network and feedback balance adjustments normally required by discrete difference-amplifier implementations.
Typical uses include industrial current sensing, bridge-transducer excitation and readout, battery monitoring, laboratory measurement systems, and instrumentation interfaces that must reject large common-mode voltage. The wide 36 V maximum supply voltage also permits operation from protected industrial rails, although the selected output range must remain within the power-supply limits.
The primary design consideration is common-mode range. Neither input should exceed the supply rails by more than the device permits, and the output must remain within its allowable swing. PCB layout should minimize differential-loop area, use a solid ground reference, and keep input and output return paths separated to reduce errors caused by parasitic resistance or ground gradients.
This page combines manufacturer specifications, package information, application guidance, comparison parameters, and practical design notes to support faster component selection and implementation of the INA133UG4 in precision analog signal chains.
直接替换替代料: INA133UG4 ——相同封装,引脚兼容。需要 PCB 改动的不同封装料号已排除。
本系列中的变体
可与以下型号直接替换的同系列型号: INA133UG4 (相同外形与封装尺寸) ——差异在于 Package, Product Type, Operating Temperature Range, RoHS Status, Gain.
INA133U
✅ 直接替换 ⚠️ 规格未核验联系询价
查看数据手册 →INA133UA
✅ 直接替换 ⚠️ 规格未核验联系询价
查看数据手册 →INA132UA
✅ 直接替换 ⚠️ 规格未核验联系询价
查看数据手册 →INA132UG4
✅ 直接替换 ⚠️ 规格未核验📋 参考替代料(不在目录中)
INA133UG4 最大额定值与电气特性
| Product Type | Precision difference amplifier |
| Number of Circuits | 1 circuit |
| -3 dB Bandwidth | 1.5 MHz |
| Slew Rate | 5 V/µs |
| Input Offset Voltage | 150 µV minimum; 450 µV maximum |
| 静态电流 | 950 µA |
| Supply Voltage Range | 4.5 V to 36 V |
| 输出电压范围 | ±2.25 V to ±18 V |
| Differential Gain | 1 V/V |
| 封装 | 8-SOIC (0.154 inch, 3.90 mm width) |
| 安装类型 | Surface mount |
| RoHS 状态 | Compliant |
INA133UG4 8-soic (0.154 inch, 3.90 mm width) 引脚配置指南
INA133UG4(8-soic (0.154 inch, 3.90 mm width) 封装)的引脚配置。 该模拟元件具有输入、输出和电源引脚。请参阅制造商数据手册以了解失调调零、补偿和使能引脚配置。适用于信号调理和放大器电路。
暂无详细引脚数据: INA133UG4.
请参阅 数据手册 以查看完整引脚配置。
典型应用
INA133UG4 适用于 6 应用s: Industrial Shunt Current Sensing, Bridge Transducer Readout, Battery Pack Monitoring, Laboratory Instrumentation, Power Converter Feedback, Portable Sensor Interfaces.
Industrial Shunt Current Sensing
The INA133UG4 fits high-side and low-side shunt-current measurement because its fixed 1 V/V gain converts the differential voltage across a shunt into a single-ended output. Its 450 µV maximum input offset voltage limits the output error attributable to input offset, while the 1.5 MHz bandwidth and 5 V/µs slew rate support changing current waveforms. The 4.5 V to 36 V supply range accommodates industrial rails, but the shunt voltage must remain inside the permitted input common-mode range. Place the amplifier close to the shunt to minimize pickup from adjacent power stages.
推荐
Bridge Transducer Readout
For resistive-bridge measurement, the INA133UG4 provides a fixed 1 V/V differential gain and rejects common-mode excitation voltage before the signal reaches the next conversion stage. Its 450 µV maximum input offset and 1.5 MHz bandwidth are useful for medium-speed pressure, load, and position bridges. The 8-SOIC layout also supports compact analog boards. Input filtering should be balanced across both sides of the bridge, and the amplifier must remain within its specified common-mode range as the bridge output changes.
推荐
Battery Pack Monitoring
INA133UG4 is suitable for monitoring differential cell or pack voltages when the signal can be observed with a fixed 1 V/V gain. Its low 950 µA quiescent current helps limit continuous overhead in portable or energy-storage monitoring systems, while the 36 V maximum supply voltage accommodates higher-energy cells and protected rails. Its 5 V/µs slew rate also permits measurement of rapid transients. The monitoring architecture must keep the input common-mode voltage within the device limits and avoid placing the amplifier in a measurement path that exceeds its supply rating.
推荐
Laboratory Instrumentation
The INA133UG4 can condition differential sensor outputs in compact laboratory instruments where fixed gain, low offset, and fast settling are useful. Its 1.5 MHz bandwidth is sufficient for many pressure, force, strain, and general-purpose analog measurement channels, while the 5 V/µs slew rate limits distortion on larger output steps. The 8-SOIC package simplifies board-level assembly and allows direct replacement within the INA133 family. For best results, use a low-noise reference and ground plane, and verify the input filtering needed to suppress interference at the measured bandwidth.
推荐
Power Converter Feedback
INA133UG4 can monitor a differential feedback voltage in a power-conversion or distributed-power system when the operating voltages remain within its 4.5 V to 36 V supply and common-mode limits. Its 1 V/V gain provides a direct representation of the sensed differential voltage, and the 950 µA quiescent current reduces continuous overhead compared with many higher-current instrumentation stages. The 1.5 MHz bandwidth supports feedback paths with moderate dynamics. Designers should compensate the amplifier delay and slew behavior in the control loop and maintain separate power and signal grounds to avoid injecting switching noise into the measurement.
推荐
Portable Sensor Interfaces
For portable sensor interfaces, the INA133UG4 combines a 950 µA quiescent current with a precision 150 µV minimum input offset voltage and a 1.5 MHz bandwidth. This combination allows a differential sensor output to be conditioned without the external gain-setting network of a discrete difference amplifier. The compact 8-SOIC package supports space-constrained boards, and the 4.5 V minimum supply supports low-voltage systems. Battery life depends on the complete signal chain, so power-gating or shutdown strategies should be evaluated around the amplifier rather than inferred from its quiescent current alone.
推荐
推荐产品汇总
工程参考数据: INA133UG4 ——对比、设计指导和合规信息。
选型指南
与替代料对比
| 参数 | 本产品 | INA133U | INA133UA | INA132UA | INA132UG4 |
|---|---|---|---|---|---|
| Brand | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments |
| Package | 8-SOIC | 8-SOIC - same | 8-SOIC - same | 8-SOIC - same | 8-SOIC - same |
| -3 dB Bandwidth | 1.5 MHz | 1.5 MHz | 1.5 MHz | Approximately 1.3 MHz | Approximately 1.3 MHz |
| Differential Gain | 1 V/V | 1 V/V | 1 V/V | 1 V/V | 1 V/V |
| Special Features | Low-power, high-precision fixed-gain difference amplifier | Same INA133 electrical family | Same INA133 electrical family | Related INA132 fixed-gain difference amplifier | Related INA132 fixed-gain difference amplifier |
关键差异点
- Higher bandwidth than the directly related INA132 options (对比 INA132UA)
- Low 950 µA supply current for precision signal conditioning (对比 INA132UA)
- Exact family compatibility for pin-compatible reuse (对比 INA133U)
设计说明
Check the input common-mode range and output swing against the actual shunt, bridge, or sensor voltages before committing the circuit. The INA133UG4 accepts a 4.5 V to 36 V supply, but that supply rating does not permit arbitrary input or output excursions. A common design error is to assume that the output can reach a supply rail. Derive the maximum expected input differential voltage, common-mode voltage, and output swing, then include startup and fault-state margin in the design.
Place the INA133UG4 close to the sensed element and route the two input conductors as a compact differential pair over a continuous ground plane. Minimize shared copper in the input path because parasitic resistance in series with the high-impedance inputs can create gain errors. Keep the output route separate from the input pair, use a solid reference plane, and place any input filtering capacitors symmetrically so their tolerances and parasitics do not unbalance the measured signal.
Use the 1.5 MHz -3 dB bandwidth and 5 V/µs slew rate to determine whether the measurement bandwidth is adequate. Avoid excessive low-frequency filtering unless it is required for noise control, because high-value input and filter capacitors can interact with the amplifier's input bias current and introduce errors. Conversely, unfiltered high-frequency pickup can corrupt a low-rate measurement even when the sensor changes slowly. Establish the required signal bandwidth, then design the filter around that bandwidth.
Estimated: with a 5 V supply, 950 µA quiescent current, and no additional output current, the amplifier's nominal supply-power dissipation is 4.75 mW using Pd = VIN × IQ. This estimate excludes load current and regulator-conversion effects. Thermal stress is therefore normally modest in the specified operating region, but the complete board still needs airflow and copper-area checks under maximum ambient temperature, especially when the INA133UG4 drives a nearby load or shares a package region with other heat sources.
合规信息
The INA133UG4 product record identifies RoHS compliance. Other environmental, automotive, halogen-free, and conflict-minerals declarations require confirmation from the manufacturer or an authoritative compliance document.