AD624ADZ - Precision Instrumentation Amplifier, 25MHz | Analog Devices
部品番号: AD624ADZ ✗ 生産終了AD624ADZ 概要
An instrumentation amplifier is a specialized differential amplifier designed to amplify the difference between two input signals while rejecting common-mode voltage. Within the signal chain hierarchy, it sits between the transducer and the ADC, combining multiple internally matched op-amp stages so that gain is set by a single resistor (or internal trims) rather than four matched resistors. This architecture delivers the high common-mode rejection, high input impedance and precise gain accuracy that general-purpose op-amps cannot achieve in bridge and transducer front ends.
Key features of the AD624 include factory-trimmed gains of 1, 100, 200, 500 and 1000 with no external components, low noise and high linearity, and a 15 us settling time that supports high speed data acquisition. The combination of low noise, high gain accuracy and low gain temperature coefficient makes it suitable for microvolt-level signals.
Architecturally, the AD624 uses a classic three-op-amp instrumentation topology with laser-trimmed input stages. The 25 MHz gain bandwidth product preserves signal fidelity even at moderate gains, while the 5 V/us slew rate prevents slewing-induced distortion on fast transducer outputs.
Typical applications include load cell and strain gauge bridge amplification, pressure transducer signal conditioning, and high speed multi-channel data acquisition systems where low offset and fast settling are both required.
A key design consideration: the 16-CDIP package is through-hole, so PCB footprint, assembly process and thermal environment must be planned around a DIP-style component; gains other than the factory trims require an external gain resistor whose value and drift directly affect accuracy.
This page synthesizes distributor stock data, drop-in family alternatives, and practical design notes not found in the manufacturer datasheet, giving sourcing and design engineers a single quotable reference.
ドロップイン代替品: AD624ADZ — 同一パッケージでピン互換。PCBの作り直しが必要な異なるパッケージの部品は除外されています。
このシリーズのバリエーション
同一シリーズでドロップイン互換のモデル: AD624ADZ (同一形状・フットプリント) — 相違点: Package, Input Offset Voltage, Mounting Type, Settling Time, Slew Rate.
AD624AD/+
✅ ドロップイン ⚠️ 仕様未検証価格はお問い合わせください
データシートを見る →AD624BDZ
✅ ドロップイン ⚠️ 仕様未検証価格はお問い合わせください
データシートを見る →AD624CDZ
✅ ドロップイン ⚠️ 仕様未検証価格はお問い合わせください
データシートを見る →AD624SD/883B
✅ ドロップイン ⚠️ 仕様未検証📋 参考代替品(カタログ未掲載)
AD524AD
✅ ドロップイン ⚠️ 仕様未検証価格はお問い合わせください
データシートを見る →AD624ADZ 最大定格&電気的特性
| Amplifier Type | Instrumentation Amplifier |
| Number of Circuits | 1 |
| Gain Bandwidth Product | 25 MHz |
| Slew Rate | 5 V/us |
| Settling Time | 15 us |
| Input Offset Voltage | 200 uV |
| Supply Voltage Range | +/-6 V to +/-18 V |
| Factory-Trimmed Gains | 1, 100, 200, 500, 1000 |
| パッケージ | 16-CDIP (0.300 inch, 7.62 mm) |
| 実装タイプ | Through Hole |
| External Components for Trimmed Gains | Not required (gains of 1, 100, 200, 500, 1000) |
| Typical Application | Load cells, strain gauges, pressure transducers, data acquisition |
AD624ADZ 16-cdip (0.300 inch, 7.62 mm) ピン配置ガイド
AD624ADZ (16-cdip (0.300 inch, 7.62 mm) パッケージ) のピン配置。 このアナログコンポーネントは、入力、出力、および電源ピンを備えています。オフセットナル、補償、イネーブルピンの設定については、メーカーのデータシートを参照してください。信号調整やアンプ回路に最適です。
詳細なピン配置データはありません: AD624ADZ.
詳細は データシート をご参照ください。
主な用途
AD624ADZ の用途: 6 件s: Load Cell and Weighing Systems, Strain Gauge Measurement, Pressure Transducer Signal Conditioning, High Speed Data Acquisition Front End, Industrial Process Control I/O, Medical and Biomedical Signal Amplification.
Load Cell and Weighing Systems
Load cells output full-scale signals in the low millivolt range, so the front-end amplifier defines the measurement resolution of the entire weighing system. The AD624ADZ fits this role because its 200 uV input offset voltage and factory-trimmed gain of 100 or 1000 turn microvolt-level bridge imbalance into an ADC-friendly signal without external gain-setting components, and its low gain temperature coefficient preserves calibration over temperature. In a typical topology, the bridge output feeds the differential inputs directly, the reference pin is tied to a low-impedance ground or offset voltage, and the 15 us settling time permits fast sample rates in dynamic weighing and checkweigher applications. Because the device operates from +/-6 V to +/-18 V dual supplies, it integrates cleanly with traditional +/-15 V industrial analog backplanes.
おすすめ
Strain Gauge Measurement
Strain gauges produce resistance changes that translate into microvolt-level differential signals on a Wheatstone bridge, demanding an amplifier with high common-mode rejection and stable gain. The AD624ADZ addresses this with its laser-trimmed three-op-amp instrumentation topology, 25 MHz gain bandwidth product and low noise, allowing gains of 100 to 1000 to be selected by pin strapping with no external precision resistor. The 15 us settling time supports high-channel-count multiplexed scanning where each channel must settle before the ADC conversion, and the 200 uV offset keeps zero-balance error small at high gains. Designers should keep the gain pins and input traces short and symmetrical, and use guard rings around the differential input pins to preserve the input stage's noise and leakage performance on a through-hole DIP layout.
おすすめ
Pressure Transducer Signal Conditioning
Piezoresistive pressure transducers typically deliver a compensated span of tens of millivolts superimposed on a large common-mode voltage, which is exactly the condition a precision instrumentation amplifier is built for. The AD624ADZ's high linearity and low gain temperature coefficient maintain calibration accuracy across the transducer's temperature range, while its 5 V/us slew rate handles fast pressure transients in hydraulic and pneumatic monitoring without slewing distortion. The factory-trimmed gain options let one design cover multiple transducer spans by strapping gains of 100, 200 or 500. Running from +/-12 V or +/-15 V supplies, it fits standard industrial sensor interface boards, and the 16-CDIP through-hole package suits high-vibration environments where surface-mount solder joints are a reliability concern.
おすすめ
High Speed Data Acquisition Front End
Multiplexed data acquisition systems require amplifiers that settle quickly after each channel switch, and settling time is often the bottleneck on scan rate. The AD624ADZ's 15 us settling time, 25 MHz gain bandwidth product and 5 V/us slew rate permit high speed data acquisition as stated by Analog Devices, enabling thousands of single-channel conversions per second at high gain without sacrificing the 200 uV offset precision. Placed directly ahead of a 12- to 16-bit ADC, the amplifier's factory-trimmed gain of 1, 100 or 1000 scales the multiplexer output into the converter's full-scale range. Designers must budget the 15 us settling interval into the acquisition timing and verify that source impedance and stray capacitance at the input pins do not degrade the settling behavior.
おすすめ
Industrial Process Control I/O
Process control systems translate thermocouple, RTD and bridge-transmitter signals into scaled voltages for controllers and recorders, and the analog input module's accuracy is set by its front-end amplifier. The AD624ADZ provides the low offset, high gain accuracy and low drift needed for 0.1%-class input modules, while the +/-18 V maximum supply rating gives headroom on industrial +/-15 V rails with transients. The 16-CDIP through-hole package withstands the thermal cycling and vibration typical of control cabinets, and field gain changes between 100 and 1000 can be made by pin strapping without recalibration of external resistors. Its reference pin allows output offset scaling for 4-20 mA transmitter interfaces built around a voltage-to-current converter stage.
おすすめ
Medical and Biomedical Signal Amplification
Biomedical signals such as ECG and sensor-bridge outputs from medical instrumentation are small, differential and ride on large electrode common-mode potentials, requiring an amplifier with excellent common-mode rejection and low noise. The AD624ADZ's precision input stage, 200 uV offset and pin-strapped gains of 100 to 1000 make it suitable for battery- or mains-isolated medical front ends built on dual supplies, and its high linearity preserves waveform fidelity for diagnostic processing. The 25 MHz bandwidth is far in excess of physiological needs, so designers should add external filtering to limit noise bandwidth, and a driven-right-leg or common-mode feedback circuit to exploit the amplifier's CMRR fully. Isolation and patient-safety standards compliance must be addressed at the system level, not by the amplifier itself.
おすすめ
おすすめ製品の概要
エンジニアリング参考データ: AD624ADZ — 比較、設計ガイダンス、コンプライアンス情報。
選定ガイド
代替品との比較
| パラメータ | この製品 | AD624AD | AD624BDZ | AD624CDZ | AD624SD/883B | AD524AD |
|---|---|---|---|---|---|---|
| Package | 16-CDIP (0.300 inch, 7.62 mm) | 16-CDIP - same | 16-CDIP - same | 16-CDIP - same | 16-CDIP - same | 16-CDIP - same |
| Brand | Analog Devices | Analog Devices | Analog Devices | Analog Devices | Analog Devices | Analog Devices |
| Factory-Trimmed Gains | 1, 100, 200, 500, 1000 | 1, 100, 200, 500, 1000 | 1, 100, 200, 500, 1000 | 1, 100, 200, 500, 1000 | 1, 100, 200, 500, 1000 | 1, 100, 200, 500, 1000 |
| RoHS / Lead Finish | RoHS lead-free (Z suffix) | Tin-lead (non-Z) | RoHS lead-free | RoHS lead-free | MIL screening (finish varies) | Tin-lead (non-Z) |
主な差別化要因
- 25 MHz gain bandwidth with 15 us settling (vs AD524AD)
- Tighter precision grades in the identical footprint (vs AD624BDZ / AD624CDZ)
- Military-screened option available (vs AD624SD/883B)
- RoHS lead-free package finish (vs AD624AD)
設計ノート
The AD624ADZ comes in a 16-pin CDIP through-hole package, so plan the land pattern per the datasheet mechanical drawing and confirm wave or selective soldering parameters for the package finish. Keep the differential input traces equal length and as short as possible, and place a guard ring driven at the input common-mode potential around pins 2 and 3 to reduce leakage-induced offset. The gain-programming pins should be routed with minimal loop area to avoid picking up noise that would appear amplified at the output.
For intermediate gains set by an external resistor, the resistor's tolerance and temperature coefficient add directly to the system gain error - use 0.1% 15 ppm/C or better precision resistors for accuracy-critical designs. With 25 MHz gain bandwidth, the device will amplify any stray high-frequency coupling at the inputs; add a small RC low-pass filter at the input pins and keep digital logic physically separated from the analog front end. Decouple both supply pins with 0.1 uF ceramic capacitors placed close to the device, plus 10 uF bulk capacitance per rail.
The most common errors with AD624-class instrumentation amplifiers are (1) leaving the reference pin connected to a high-impedance node, which degrades CMRR - always drive it from a low-impedance source or ground it directly; (2) applying single-supply operation, since the part requires dual supplies of at least +/-6 V; and (3) exceeding the 15 us settling interval in multiplexed systems, which causes inter-channel crosstalk. Verify the common-mode input range in the manufacturer datasheet at your chosen gain and supply combination before finalizing the design.
コンプライアンス情報
The Z suffix denotes Analog Devices' RoHS-compliant lead-free package variant. REACH, halogen-free and conflict-minerals status should be confirmed on the Analog Devices product page.