AD624BDZ - 25 MHz Low-Noise Instrumentation Amplifier | Analog Devices
部品番号: AD624BDZ ✗ 生産終了AD624BDZ 概要
An instrumentation amplifier is a precision analog signal-conditioning device built to amplify small differential sensor signals while rejecting common-mode noise and interference. The AD624 family is commonly used with load cells, strain gauges, and pressure transducers because it combines differential input handling, high gain accuracy, low noise, and fast settling performance in one integrated circuit. In a typical measurement chain, the sensor converts a physical quantity into a small differential voltage, the AD624BDZ amplifies that voltage, and a downstream ADC or data-acquisition system performs digitization.
The AD624 offers several features suited to precision measurement systems. Its internal trimmed gain options eliminate the need for precision external feedback resistors for common gain settings, while its high bandwidth supports faster acquisition cycles than a conventional slow instrumentation amplifier. The 5 V/µs slew rate helps preserve signal fidelity during large transient responses, and the 15 µs settling time allows the amplifier output to stabilize rapidly between measurements. Low noise makes the device suitable for sensors whose useful signal amplitude is close to the measurement system’s noise floor.
The AD624BDZ uses a three-op-amp instrumentation-amplifier architecture to provide high input impedance and accurate differential gain. Its internal resistors and trim circuitry establish accurate gain without requiring external calibration resistors for the predefined gains. The device is intended for systems operating from dual positive and negative supplies, allowing bipolar sensor signals to remain centered around ground. The manufacturer identifies the AD624 as a precision, low-noise instrumentation amplifier with strong DC and AC performance.
Typical applications include industrial load-cell measurement, strain-gauge bridges, pressure-transducer interfaces, laboratory instrumentation, biomedical signal acquisition, and high-speed data-acquisition systems. The 16-lead ceramic-DIP package makes it suitable for equipment requiring a through-hole component and a conventional industrial or laboratory instrumentation architecture.
When using the AD624BDZ, confirm the supply voltage, gain configuration, input common-mode range, and output swing against the sensor and ADC interface. Place the device close to the transducer to minimize interference pickup on high-impedance sensor lines, and use suitable bypassing capacitors around the power pins. The ceramic DIP package also requires attention to socket or PCB through-hole alignment and thermal management during system assembly.
This page combines manufacturer specifications, package information, pricing references, and practical selection guidance for engineers evaluating the AD624BDZ in precision sensor-conditioning and data-acquisition designs.
ドロップイン代替品: AD624BDZ — 同一パッケージでピン互換。PCBの作り直しが必要な異なるパッケージの部品は除外されています。
このシリーズのバリエーション
同一シリーズでドロップイン互換のモデル: AD624BDZ (同一形状・フットプリント) — 相違点: Package, Mounting Type, Input Offset Voltage, Settling Time, Slew Rate.
AD624BD
✅ ドロップイン価格はお問い合わせください
データシートを見る →AD624CDZ
✅ ドロップイン価格はお問い合わせください
データシートを見る →AD624SD/883B
✅ ドロップイン📋 参考代替品(カタログ未掲載)
AD624BDZ 最大定格&電気的特性
| Product Type | Precision instrumentation amplifier |
| Number of Amplifiers | 1 circuit |
| Gain-Bandwidth Product | 25 MHz |
| Slew Rate | 5 V/µs |
| Settling Time | 15 µs |
| Input Offset Voltage | 75 µV |
| Supply Voltage Range | ±6 V to ±18 V |
| Trimmed Gain Settings | 1, 100, 200, 500, and 1000 |
| External Gain-Setting Components | Not required for trimmed gains |
| Input Signal Type | Differential |
| パッケージ | 16-lead ceramic DIP |
| 実装タイプ | Through-hole |
| RoHS ステータス | unknown |
| REACH Status | unknown |
| Automotive Qualification | not_applicable |
AD624BDZ 16-lead ceramic dip ピン配置ガイド
AD624BDZ (16-lead ceramic dip パッケージ) のピン配置。 このアナログコンポーネントは、入力、出力、および電源ピンを備えています。オフセットナル、補償、イネーブルピンの設定については、メーカーのデータシートを参照してください。信号調整やアンプ回路に最適です。
詳細なピン配置データはありません: AD624BDZ.
詳細は データシート をご参照ください。
主な用途
AD624BDZ の用途: 6 件s: Load-Cell Measurement, Strain-Gauge Signal Conditioning, Pressure Transducer Interface, High-Speed Data Acquisition, Biomedical Sensor Signal, Laboratory Instrumentation.
Load-Cell Measurement
The AD624BDZ suits load-cell front ends that produce small differential voltages from a bridge sensor. Its precision instrumentation-amplifier architecture provides high common-mode rejection while the low-noise, 25 MHz gain-bandwidth product supports fast measurement acquisition. Internal trimmed gains of 1, 100, 200, 500, and 1000 simplify calibration for common bridge sensitivities. The 5 V/µs slew rate and 15 µs settling time help the system settle quickly between successive readings.
おすすめ
Strain-Gauge Signal Conditioning
The AD624BDZ is appropriate for strain-gauge bridge conditioning where the useful differential signal is small and susceptible to interference. The device combines a 75 µV input offset specification with low noise, helping preserve measurement integrity in precision strain systems. Its selectable internal gains reduce external resistor requirements for common gain values, while the 16-lead ceramic DIP package fits through-hole instrumentation and test equipment.
おすすめ
Pressure Transducer Interface
The AD624BDZ can condition the millivolt-level output of a bridge-based pressure transducer while rejecting common-mode voltage present on the sensor lines. Its 25 MHz gain-bandwidth product and 15 µs settling time support fast data-acquisition sequences, and the 5 V/µs slew rate improves response to transient events. Internal trimmed gains from 1 through 1000 provide several sensitivity ranges without requiring a full external gain network.
おすすめ
High-Speed Data Acquisition
The AD624BDZ fits high-speed acquisition channels that need more bandwidth than a slow precision instrumentation amplifier. Its 25 MHz gain-bandwidth product, 5 V/µs slew rate, and 15 µs settling time allow output settling between measurements. The part is useful where sensor signals must be amplified before ADC sampling while preserving low noise and accurate differential behavior.
おすすめ
Biomedical Sensor Signal
The AD624BDZ can amplify small differential biomedical sensor signals when the circuit requires accurate offset control and low-noise amplification. The 75 µV input offset specification and internal trimmed gains help establish repeatable measurement conditions, while the fast settling behavior supports rapid signal sampling. Designers should still verify patient-safety isolation requirements, input protection, and applicable medical standards before connecting the amplifier to a clinical system.
おすすめ
Laboratory Instrumentation
The AD624BDZ is well suited to precision laboratory instruments that combine selectable gain, low noise, and rapid settling. The internal gain choices support repeatable setup for different sensor sensitivities, and the 25 MHz bandwidth allows acquisition systems to sample transient or time-varying inputs. Its through-hole ceramic-DIP package is convenient for laboratory electronics, modular instruments, and serviceable measurement platforms.
おすすめ
おすすめ製品の概要
エンジニアリング参考データ: AD624BDZ — 比較、設計ガイダンス、コンプライアンス情報。
選定ガイド
代替品との比較
| パラメータ | この製品 | AD624BD | AD624CDZ | AD624SD/883B |
|---|---|---|---|---|
| Package | 16-lead ceramic DIP | 16-lead ceramic DIP | 16-lead ceramic DIP | 16-lead ceramic DIP |
| Brand | Analog Devices | Analog Devices | Analog Devices | Analog Devices |
| Product Type | Precision instrumentation amplifier | AD624-family instrumentation amplifier | AD624-family instrumentation amplifier | AD624-family instrumentation amplifier |
主な差別化要因
- Fast measurement settling (vs AD624BD)
- Internal gain programming without external resistors (vs AD624CDZ)
- Precision input offset specification (vs AD624SD/883B)
設計ノート
Place the AD624BDZ close to the sensor input connector and route the differential input pair as a short, tightly coupled pair. High-impedance transducer lines should be kept away from switching nodes and digital timing signals. The manufacturer’s application guidance and pin-description table should be used to identify the input and supply pins on the 16-lead ceramic-DIP footprint.
The AD624BDZ requires positive and negative supplies in the ±6 V to ±18 V range. Confirm that both rails remain within limits under startup, load transients, and supply ripple. Use local decoupling close to the supply pins, with capacitor values and stability requirements selected from the manufacturer datasheet.
Do not assume that every AD624 suffix is an automatic drop-in replacement. Confirm the ceramic-DIP lead count, pin names, temperature grade, gain implementation, and required external components for AD624BD, AD624CDZ, or AD624SD/883B. For custom gains, follow the manufacturer’s resistor values and layout guidance rather than changing feedback components without stability checks.
The 25 MHz gain-bandwidth product, 5 V/µs slew rate, and 15 µs settling time make bandwidth and settling time important in acquisition systems. Account for the complete signal chain, including sensor capacitance, cable capacitance, output loading, and ADC acquisition time. Provide a defined settling interval before taking a measurement when the source changes rapidly.
コンプライアンス情報
Compliance attributes are not specified for the AD624BDZ in the available product information. The 16-lead ceramic-DIP package and ±6 V to ±18 V supply range are identified, while detailed package drawing and ordering-grade information should be checked in the manufacturer datasheet.