AD624ADZ - Precision Instrumentation Amplifier, 25MHz | Analog Devices
부품 번호: AD624ADZ ✗ 단종AD624ADZ 개요
An instrumentation amplifier is a specialized differential amplifier designed to amplify the difference between two input signals while rejecting common-mode voltage. Within the signal chain hierarchy, it sits between the transducer and the ADC, combining multiple internally matched op-amp stages so that gain is set by a single resistor (or internal trims) rather than four matched resistors. This architecture delivers the high common-mode rejection, high input impedance and precise gain accuracy that general-purpose op-amps cannot achieve in bridge and transducer front ends.
Key features of the AD624 include factory-trimmed gains of 1, 100, 200, 500 and 1000 with no external components, low noise and high linearity, and a 15 us settling time that supports high speed data acquisition. The combination of low noise, high gain accuracy and low gain temperature coefficient makes it suitable for microvolt-level signals.
Architecturally, the AD624 uses a classic three-op-amp instrumentation topology with laser-trimmed input stages. The 25 MHz gain bandwidth product preserves signal fidelity even at moderate gains, while the 5 V/us slew rate prevents slewing-induced distortion on fast transducer outputs.
Typical applications include load cell and strain gauge bridge amplification, pressure transducer signal conditioning, and high speed multi-channel data acquisition systems where low offset and fast settling are both required.
A key design consideration: the 16-CDIP package is through-hole, so PCB footprint, assembly process and thermal environment must be planned around a DIP-style component; gains other than the factory trims require an external gain resistor whose value and drift directly affect accuracy.
This page synthesizes distributor stock data, drop-in family alternatives, and practical design notes not found in the manufacturer datasheet, giving sourcing and design engineers a single quotable reference.
드롭인 대체품: AD624ADZ — 동일 패키지, 핀 호환. PCB 재작업이 필요한 다른 패키지 부품은 제외됩니다.
이 시리즈의 변형
다음과 드롭인 호환되는 동일 시리즈 모델: AD624ADZ (동일 폼 팩터 및 풋프린트) — 차이점: Package, Input Offset Voltage, Mounting Type, Settling Time, Slew Rate.
AD624AD/+
✅ 드롭인 ⚠️ 사양 미검증가격 문의
데이터시트 보기 →AD624BDZ
✅ 드롭인 ⚠️ 사양 미검증가격 문의
데이터시트 보기 →AD624CDZ
✅ 드롭인 ⚠️ 사양 미검증가격 문의
데이터시트 보기 →AD624SD/883B
✅ 드롭인 ⚠️ 사양 미검증📋 참조 대체품 (카탈로그에 없음)
AD524AD
✅ 드롭인 ⚠️ 사양 미검증가격 문의
데이터시트 보기 →AD624ADZ 최대 정격 & 전기적 특성
| Amplifier Type | Instrumentation Amplifier |
| Number of Circuits | 1 |
| Gain Bandwidth Product | 25 MHz |
| Slew Rate | 5 V/us |
| Settling Time | 15 us |
| Input Offset Voltage | 200 uV |
| Supply Voltage Range | +/-6 V to +/-18 V |
| Factory-Trimmed Gains | 1, 100, 200, 500, 1000 |
| 패키지 | 16-CDIP (0.300 inch, 7.62 mm) |
| 실장 유형 | Through Hole |
| External Components for Trimmed Gains | Not required (gains of 1, 100, 200, 500, 1000) |
| Typical Application | Load cells, strain gauges, pressure transducers, data acquisition |
AD624ADZ 16-cdip (0.300 inch, 7.62 mm) 핀 구성 가이드
AD624ADZ(16-cdip (0.300 inch, 7.62 mm) 패키지)의 핀 구성입니다. 이 아날로그 부품에는 입력, 출력, 전원 공급 핀이 있습니다. 오프셋 널, 보상, 인에이블 핀 구성은 제조사 데이터시트를 참조하십시오. 신호 컨디셔닝 및 증폭기 회로에 이상적입니다.
다음에 대한 상세 핀아웃 데이터 없음: AD624ADZ.
다음을 참조하십시오: 데이터시트 전체 핀 구성은 다음을 참조하십시오.
일반적인 애플리케이션
AD624ADZ 적합 용도: 6 애플리케이션s: Load Cell and Weighing Systems, Strain Gauge Measurement, Pressure Transducer Signal Conditioning, High Speed Data Acquisition Front End, Industrial Process Control I/O, Medical and Biomedical Signal Amplification.
Load Cell and Weighing Systems
Load cells output full-scale signals in the low millivolt range, so the front-end amplifier defines the measurement resolution of the entire weighing system. The AD624ADZ fits this role because its 200 uV input offset voltage and factory-trimmed gain of 100 or 1000 turn microvolt-level bridge imbalance into an ADC-friendly signal without external gain-setting components, and its low gain temperature coefficient preserves calibration over temperature. In a typical topology, the bridge output feeds the differential inputs directly, the reference pin is tied to a low-impedance ground or offset voltage, and the 15 us settling time permits fast sample rates in dynamic weighing and checkweigher applications. Because the device operates from +/-6 V to +/-18 V dual supplies, it integrates cleanly with traditional +/-15 V industrial analog backplanes.
추천
Strain Gauge Measurement
Strain gauges produce resistance changes that translate into microvolt-level differential signals on a Wheatstone bridge, demanding an amplifier with high common-mode rejection and stable gain. The AD624ADZ addresses this with its laser-trimmed three-op-amp instrumentation topology, 25 MHz gain bandwidth product and low noise, allowing gains of 100 to 1000 to be selected by pin strapping with no external precision resistor. The 15 us settling time supports high-channel-count multiplexed scanning where each channel must settle before the ADC conversion, and the 200 uV offset keeps zero-balance error small at high gains. Designers should keep the gain pins and input traces short and symmetrical, and use guard rings around the differential input pins to preserve the input stage's noise and leakage performance on a through-hole DIP layout.
추천
Pressure Transducer Signal Conditioning
Piezoresistive pressure transducers typically deliver a compensated span of tens of millivolts superimposed on a large common-mode voltage, which is exactly the condition a precision instrumentation amplifier is built for. The AD624ADZ's high linearity and low gain temperature coefficient maintain calibration accuracy across the transducer's temperature range, while its 5 V/us slew rate handles fast pressure transients in hydraulic and pneumatic monitoring without slewing distortion. The factory-trimmed gain options let one design cover multiple transducer spans by strapping gains of 100, 200 or 500. Running from +/-12 V or +/-15 V supplies, it fits standard industrial sensor interface boards, and the 16-CDIP through-hole package suits high-vibration environments where surface-mount solder joints are a reliability concern.
추천
High Speed Data Acquisition Front End
Multiplexed data acquisition systems require amplifiers that settle quickly after each channel switch, and settling time is often the bottleneck on scan rate. The AD624ADZ's 15 us settling time, 25 MHz gain bandwidth product and 5 V/us slew rate permit high speed data acquisition as stated by Analog Devices, enabling thousands of single-channel conversions per second at high gain without sacrificing the 200 uV offset precision. Placed directly ahead of a 12- to 16-bit ADC, the amplifier's factory-trimmed gain of 1, 100 or 1000 scales the multiplexer output into the converter's full-scale range. Designers must budget the 15 us settling interval into the acquisition timing and verify that source impedance and stray capacitance at the input pins do not degrade the settling behavior.
추천
Industrial Process Control I/O
Process control systems translate thermocouple, RTD and bridge-transmitter signals into scaled voltages for controllers and recorders, and the analog input module's accuracy is set by its front-end amplifier. The AD624ADZ provides the low offset, high gain accuracy and low drift needed for 0.1%-class input modules, while the +/-18 V maximum supply rating gives headroom on industrial +/-15 V rails with transients. The 16-CDIP through-hole package withstands the thermal cycling and vibration typical of control cabinets, and field gain changes between 100 and 1000 can be made by pin strapping without recalibration of external resistors. Its reference pin allows output offset scaling for 4-20 mA transmitter interfaces built around a voltage-to-current converter stage.
추천
Medical and Biomedical Signal Amplification
Biomedical signals such as ECG and sensor-bridge outputs from medical instrumentation are small, differential and ride on large electrode common-mode potentials, requiring an amplifier with excellent common-mode rejection and low noise. The AD624ADZ's precision input stage, 200 uV offset and pin-strapped gains of 100 to 1000 make it suitable for battery- or mains-isolated medical front ends built on dual supplies, and its high linearity preserves waveform fidelity for diagnostic processing. The 25 MHz bandwidth is far in excess of physiological needs, so designers should add external filtering to limit noise bandwidth, and a driven-right-leg or common-mode feedback circuit to exploit the amplifier's CMRR fully. Isolation and patient-safety standards compliance must be addressed at the system level, not by the amplifier itself.
추천
추천 제품 요약
엔지니어링 참조 데이터: AD624ADZ — 비교, 설계 지침 및 규정 준수 정보.
선택 가이드
대체품과의 비교
| 파라미터 | 이 제품 | AD624AD | AD624BDZ | AD624CDZ | AD624SD/883B | AD524AD |
|---|---|---|---|---|---|---|
| Package | 16-CDIP (0.300 inch, 7.62 mm) | 16-CDIP - same | 16-CDIP - same | 16-CDIP - same | 16-CDIP - same | 16-CDIP - same |
| Brand | Analog Devices | Analog Devices | Analog Devices | Analog Devices | Analog Devices | Analog Devices |
| Factory-Trimmed Gains | 1, 100, 200, 500, 1000 | 1, 100, 200, 500, 1000 | 1, 100, 200, 500, 1000 | 1, 100, 200, 500, 1000 | 1, 100, 200, 500, 1000 | 1, 100, 200, 500, 1000 |
| RoHS / Lead Finish | RoHS lead-free (Z suffix) | Tin-lead (non-Z) | RoHS lead-free | RoHS lead-free | MIL screening (finish varies) | Tin-lead (non-Z) |
주요 차별점
- 25 MHz gain bandwidth with 15 us settling (vs AD524AD)
- Tighter precision grades in the identical footprint (vs AD624BDZ / AD624CDZ)
- Military-screened option available (vs AD624SD/883B)
- RoHS lead-free package finish (vs AD624AD)
설계 노트
The AD624ADZ comes in a 16-pin CDIP through-hole package, so plan the land pattern per the datasheet mechanical drawing and confirm wave or selective soldering parameters for the package finish. Keep the differential input traces equal length and as short as possible, and place a guard ring driven at the input common-mode potential around pins 2 and 3 to reduce leakage-induced offset. The gain-programming pins should be routed with minimal loop area to avoid picking up noise that would appear amplified at the output.
For intermediate gains set by an external resistor, the resistor's tolerance and temperature coefficient add directly to the system gain error - use 0.1% 15 ppm/C or better precision resistors for accuracy-critical designs. With 25 MHz gain bandwidth, the device will amplify any stray high-frequency coupling at the inputs; add a small RC low-pass filter at the input pins and keep digital logic physically separated from the analog front end. Decouple both supply pins with 0.1 uF ceramic capacitors placed close to the device, plus 10 uF bulk capacitance per rail.
The most common errors with AD624-class instrumentation amplifiers are (1) leaving the reference pin connected to a high-impedance node, which degrades CMRR - always drive it from a low-impedance source or ground it directly; (2) applying single-supply operation, since the part requires dual supplies of at least +/-6 V; and (3) exceeding the 15 us settling interval in multiplexed systems, which causes inter-channel crosstalk. Verify the common-mode input range in the manufacturer datasheet at your chosen gain and supply combination before finalizing the design.
규정 준수 정보
The Z suffix denotes Analog Devices' RoHS-compliant lead-free package variant. REACH, halogen-free and conflict-minerals status should be confirmed on the Analog Devices product page.