INA116PAG4 - Ultra-Low Bias Instrumentation Amplifier | TI
部品番号: INA116PAG4 ✗ 生産終了INA116PAG4 概要
An instrumentation amplifier is a specialized amplifier that measures a small voltage appearing between two inputs while rejecting common-mode voltage, supply noise, and other signals common to both inputs. The INA116PAG4 belongs to the instrumentation-amplifier hierarchy within precision analog signal-chain ICs. Its FET-input architecture and special input-guarding techniques are particularly useful when measuring high-impedance sources whose charging current could otherwise disturb the measurement.
The principal features include a 3 fA typical input bias current at 25°C, 25 fA at 85°C, 2 mV maximum input offset voltage, 94 dB common-mode rejection, and a 0.08 V/µs slew rate. Buffered guard-drive pins help reduce leakage through board contamination and PCB insulation paths. The 1-to-1000 gain range makes the device useful across sensor interfaces, precision current shunts, bridge amplifiers, and high-impedance measurement systems.
The INA116 uses a three-op-amp instrumentation-amplifier topology, allowing the closed-loop gain to be established with a single gain-setting resistor. Its bandwidth supports accurate static and moderate-frequency measurements, but the usable bandwidth decreases as gain increases according to the gain-bandwidth relationship. Buffered inputs, a low-noise internal design, and the available guard outputs help preserve signal integrity in high-impedance layouts.
Typical uses include photodiode and electrochemical sensor interfaces, precision shunt amplifiers, laboratory instrumentation, and industrial current sensing. The 16-pin PDIP package also supports through-hole assembly and prototyping systems. Because input bias current and leakage dominate many high-impedance designs, the physical implementation around the input and guard pins is as important as the nominal amplifier specifications.
For reliable operation, keep input and gain-resistor connections short, provide the supply and bypass-capacitor arrangement specified by the manufacturer, and route guard outputs as shown in the datasheet. Confirm the maximum input voltage, common-mode range, output swing, and operating-temperature limits for the actual board revision before connecting external sources.
This page combines device specifications, lifecycle information, drop-in alternatives, comparison data, and practical high-impedance layout guidance. It is intended to help engineers evaluate the INA116PAG4 quickly while preserving the leakage, guarding, gain, and supply considerations that determine real measurement performance.
ドロップイン代替品: INA116PAG4 — 同一パッケージでピン互換。PCBの作り直しが必要な異なるパッケージの部品は除外されています。
このシリーズのバリエーション
同一シリーズでドロップイン互換のモデル: INA116PAG4 (同一形状・フットプリント) — 相違点: Gain Range, Mounting Type, Package.
INA116PA
✅ ドロップイン価格はお問い合わせください
データシートを見る →INA116PAG4 最大定格&電気的特性
| Product Type | Precision instrumentation amplifier |
| Number of Amplifiers | 1 circuit |
| Typical Input Bias Current at 25°C | 3 fA |
| Input Bias Current at 85°C | 25 fA |
| Maximum Input Offset Voltage | 2 mV |
| Typical Input Offset Voltage | 5 mV |
| Common-Mode Rejection Ratio | 94 dB |
| Bandwidth | 800 kHz |
| Slew Rate | 0.08 V/µs |
| Gain Range | 1 to 1000 |
| Supply Voltage Range | ±4.5 V to ±18 V |
| 出力タイプ | Single-ended |
| Input Architecture | DIFET FET input |
| Guard Drive | Buffered guard-drive pins |
| パッケージ | 16-pin PDIP |
| 実装タイプ | Through-hole |
| RoHS ステータス | Green product |
| Maximum Input Voltage | ±40 V |
INA116PAG4 16-pin pdip ピン配置ガイド
INA116PAG4 (16-pin pdip パッケージ) のピン配置。 このアナログコンポーネントは、入力、出力、および電源ピンを備えています。オフセットナル、補償、イネーブルピンの設定については、メーカーのデータシートを参照してください。信号調整やアンプ回路に最適です。
詳細なピン配置データはありません: INA116PAG4.
詳細は データシート をご参照ください。
主な用途
INA116PAG4 の用途: 6 件s: Precision Current-Shunt Measurement, High-Impedance Sensor Interface, Photodiode Signal Conditioning, Laboratory Bridge Amplifier, Electrochemical Sensor Front End, Industrial Process Measurement.
Precision Current-Shunt Measurement
The INA116PAG4 suits precision shunt measurements because its 2 mV maximum input offset voltage, 94 dB common-mode rejection, and gain range of 1 to 1000 support accurate extraction of a small differential voltage from a larger common-mode potential. Connect the shunt through a Kelvin route so current does not share the measurement ground path, and place the gain resistor close to the amplifier. The principal trade-off is that usable bandwidth decreases as gain rises, so a high gain chosen for millivolt-level signals may not preserve the device’s full 800 kHz small-signal bandwidth.
おすすめ
High-Impedance Sensor Interface
The INA116PAG4 is appropriate for sensor nodes where source current must remain extremely low. Its typical input bias current of 3 fA at 25°C limits the loading presented to high-impedance detectors, while the 94 dB common-mode rejection helps suppress supply and ground disturbances shared by both sensor outputs. Use the guarded input layout from the manufacturer datasheet, keep leakage-sensitive nodes clean, and account for the rise to 25 fA at 85°C when calculating the allowable source impedance and temperature-related error.
おすすめ
Photodiode Signal Conditioning
The INA116PAG4 can condition weak photodiode currents because its 3 fA typical input bias current minimizes error contributed by the amplifier itself. The adjustable gain of 1 to 1000 provides room to amplify the photodiode voltage before a downstream converter or controller. Layout remains decisive: route the photodiode input directly to the relevant pins, use the guard-drive structure correctly, and provide stable bypass capacitance. Because the device is optimized for low bias current rather than unlimited bandwidth, photodiode capacitance and settling requirements must be checked against the selected gain.
おすすめ
Laboratory Bridge Amplifier
The INA116PAG4 is well suited to laboratory bridge measurements where a small sensor-generated differential voltage must be measured in the presence of a substantial common-mode voltage. The 94 dB CMRR suppresses common-mode noise, while the low input bias current avoids disturbing resistive bridges and other high-impedance sources. Use one external gain resistor to establish the required gain, route the bridge return separately from output ground, and verify output headroom before selecting a high gain. The device’s single-ended output simplifies connection to oscilloscopes, data converters, and external ADC front ends.
おすすめ
Electrochemical Sensor Front End
The INA116PAG4 is suitable for electrochemical and other chemical sensors that produce a small differential signal and have high source impedance. Its 3 fA typical input bias current at 25°C minimizes amplifier-generated error, and the selectable gain from 1 to 1000 accommodates signals spanning widely different concentrations. The buffered guard pins are particularly relevant because contamination and moisture on a PCB can create leakage paths comparable to the sensor current. Follow the recommended guarding layout, protect sensitive nodes from contamination, and include an input protection strategy that respects the ±40 V maximum input rating.
おすすめ
Industrial Process Measurement
The INA116PAG4 can amplify low-level process signals when the design requires low input bias current and strong rejection of common-mode voltage. Its 94 dB CMRR supports measurements taken above ground, while the adjustable closed-loop gain simplifies scaling from millivolts to a usable analog output. For industrial equipment, include transient protection, verify the common-mode range at the chosen gain, and provide local bypass capacitance close to the supply pins. The instrument-amplifier topology integrates three amplifiers, so PCB symmetry and clean return routing are important for preserving common-mode performance.
おすすめ
おすすめ製品の概要
エンジニアリング参考データ: INA116PAG4 — 比較、設計ガイダンス、コンプライアンス情報。
選定ガイド
代替品との比較
| パラメータ | この製品 | INA116PA |
|---|---|---|
| Brand | Texas Instruments | Texas Instruments |
| Package | 16-pin PDIP | 16-pin PDIP |
| Product Type | Instrumentation amplifier | Instrumentation amplifier |
| Number of Amplifiers | 1 circuit | 1 circuit |
| Bandwidth | 800 kHz | 800 kHz |
| Common-Mode Rejection Ratio | 94 dB | 94 dB |
| Input Offset Voltage | 5 mV typical | 5 mV |
| Slew Rate | 0.08 V/µs | 0.08 V/µs |
| Supply Voltage Range | ±4.5 V to ±18 V | ±4.5 V to ±18 V |
主な差別化要因
- Exceptionally low input bias current (vs INA116PA)
- Integrated precision gain setting (vs INA116PA)
- Common-mode rejection suited to noisy industrial signals (vs INA116PA)
設計ノート
Route the differential inputs and gain resistor as short, guarded traces, with the gain resistor located immediately across the designated pins. For high-impedance sources, reproduce the manufacturer’s guard-drive connection rather than treating the guard pins as ordinary outputs. Contamination, solder residue, and moisture can create leakage comparable to the device’s femtoampere-scale bias current, so clean the board and keep high-impedance nodes away from dirty or condensing areas.
Do not select the gain solely from the maximum value of 1000. The usable bandwidth falls as closed-loop gain increases, so verify the required signal bandwidth and settling behavior against the gain selected. Also distinguish the ±40 V maximum input rating from the operating common-mode range. The input must remain within both the absolute maximum and the functional common-mode limits at the installed gain and supply voltage.
Place the manufacturer-recommended bypass capacitors close to the supply pins and keep supply-current returns compact to prevent parasitic inductance from converting output switching into supply noise. The INA116PAG4 accepts ±4.5 V to ±18 V supplies, but the usable input and output ranges depend on the selected gain. Verify common-mode headroom, output swing, and dual-supply sequencing before applying a bipolar input source.
For low-level shunt or sensor measurements, use a true differential route and separate the Kelvin return from the power ground path. Avoid sharing copper between the shunt return and sensitive output reference where possible. Include offset, bias-current error, resistor mismatch, and common-mode error in the total accuracy calculation; the listed 2 mV maximum input offset voltage alone does not represent the complete measurement uncertainty.
コンプライアンス情報
The component is described as a Green product, but explicit RoHS, REACH, lead-free, halogen-free, conflict-minerals, and automotive qualification statements are not stated in the available product information. AEC-Q100 is not applicable to the listed general-purpose device.