INA116PAG4 개요

The Texas Instruments INA116PAG4 is a precision instrumentation amplifier with extremely low input bias current, a typical value of 3 fA at 25°C, a bandwidth of 800 kHz, and a 16-pin PDIP package. Its gain can be set from 1 to 1000 with one external resistor, while its low input offset voltage supports accurate differential-signal measurement. The device operates from ±4.5 V to ±18 V and is designed for current measurement, sensing, and instrumentation applications.

An instrumentation amplifier is a specialized amplifier that measures a small voltage appearing between two inputs while rejecting common-mode voltage, supply noise, and other signals common to both inputs. The INA116PAG4 belongs to the instrumentation-amplifier hierarchy within precision analog signal-chain ICs. Its FET-input architecture and special input-guarding techniques are particularly useful when measuring high-impedance sources whose charging current could otherwise disturb the measurement.

The principal features include a 3 fA typical input bias current at 25°C, 25 fA at 85°C, 2 mV maximum input offset voltage, 94 dB common-mode rejection, and a 0.08 V/µs slew rate. Buffered guard-drive pins help reduce leakage through board contamination and PCB insulation paths. The 1-to-1000 gain range makes the device useful across sensor interfaces, precision current shunts, bridge amplifiers, and high-impedance measurement systems.

The INA116 uses a three-op-amp instrumentation-amplifier topology, allowing the closed-loop gain to be established with a single gain-setting resistor. Its bandwidth supports accurate static and moderate-frequency measurements, but the usable bandwidth decreases as gain increases according to the gain-bandwidth relationship. Buffered inputs, a low-noise internal design, and the available guard outputs help preserve signal integrity in high-impedance layouts.

Typical uses include photodiode and electrochemical sensor interfaces, precision shunt amplifiers, laboratory instrumentation, and industrial current sensing. The 16-pin PDIP package also supports through-hole assembly and prototyping systems. Because input bias current and leakage dominate many high-impedance designs, the physical implementation around the input and guard pins is as important as the nominal amplifier specifications.

For reliable operation, keep input and gain-resistor connections short, provide the supply and bypass-capacitor arrangement specified by the manufacturer, and route guard outputs as shown in the datasheet. Confirm the maximum input voltage, common-mode range, output swing, and operating-temperature limits for the actual board revision before connecting external sources.

This page combines device specifications, lifecycle information, drop-in alternatives, comparison data, and practical high-impedance layout guidance. It is intended to help engineers evaluate the INA116PAG4 quickly while preserving the leakage, guarding, gain, and supply considerations that determine real measurement performance.

드롭인 대체품: INA116PAG4 — 동일 패키지, 핀 호환. PCB 재작업이 필요한 다른 패키지 부품은 제외됩니다.

이 시리즈의 변형

다음과 드롭인 호환되는 동일 시리즈 모델: INA116PAG4 (동일 폼 팩터 및 풋프린트) — 차이점: Gain Range, Mounting Type, Package.

Texas Instruments
Gain Range: 1 V/V to 1000 V/V
Mounting Type: Through Hole
Package: 16-PDIP (N)
비교 대상: INA116PAG4 →

INA116PA

✅ 드롭인
Texas Instruments
📦 16-pin PDIP
Instrumentation Amplifier · 1 · 3 fA at 25C · 25 fA · 2 mV · 1 V/V to 1000 V/V · 86 dB · 28 nV/sqrt(Hz)

가격 문의

데이터시트 보기 →

INA116PAG4 최대 정격 & 전기적 특성

Product Type Precision instrumentation amplifier
Number of Amplifiers 1 circuit
Typical Input Bias Current at 25°C 3 fA
Input Bias Current at 85°C 25 fA
Maximum Input Offset Voltage 2 mV
Typical Input Offset Voltage 5 mV
Common-Mode Rejection Ratio 94 dB
Bandwidth 800 kHz
Slew Rate 0.08 V/µs
Gain Range 1 to 1000
Supply Voltage Range ±4.5 V to ±18 V
출력 유형 Single-ended
Input Architecture DIFET FET input
Guard Drive Buffered guard-drive pins
패키지 16-pin PDIP
실장 유형 Through-hole
RoHS 상태 Green product
Maximum Input Voltage ±40 V

INA116PAG4 16-pin pdip 핀 구성 가이드

INA116PAG4(16-pin pdip 패키지)의 핀 구성입니다. 이 아날로그 부품에는 입력, 출력, 전원 공급 핀이 있습니다. 오프셋 널, 보상, 인에이블 핀 구성은 제조사 데이터시트를 참조하십시오. 신호 컨디셔닝 및 증폭기 회로에 이상적입니다.

INA116PAG4의 16-pin pdip 패키지 핀아웃 다이어그램

다음에 대한 상세 핀아웃 데이터 없음: INA116PAG4.

다음을 참조하십시오: 데이터시트 전체 핀 구성은 다음을 참조하십시오.

일반적인 애플리케이션

INA116PAG4 적합 용도: 6 애플리케이션s: Precision Current-Shunt Measurement, High-Impedance Sensor Interface, Photodiode Signal Conditioning, Laboratory Bridge Amplifier, Electrochemical Sensor Front End, Industrial Process Measurement.

⚡

Precision Current-Shunt Measurement

The INA116PAG4 suits precision shunt measurements because its 2 mV maximum input offset voltage, 94 dB common-mode rejection, and gain range of 1 to 1000 support accurate extraction of a small differential voltage from a larger common-mode potential. Connect the shunt through a Kelvin route so current does not share the measurement ground path, and place the gain resistor close to the amplifier. The principal trade-off is that usable bandwidth decreases as gain rises, so a high gain chosen for millivolt-level signals may not preserve the device’s full 800 kHz small-signal bandwidth.

🧩

High-Impedance Sensor Interface

The INA116PAG4 is appropriate for sensor nodes where source current must remain extremely low. Its typical input bias current of 3 fA at 25°C limits the loading presented to high-impedance detectors, while the 94 dB common-mode rejection helps suppress supply and ground disturbances shared by both sensor outputs. Use the guarded input layout from the manufacturer datasheet, keep leakage-sensitive nodes clean, and account for the rise to 25 fA at 85°C when calculating the allowable source impedance and temperature-related error.

📷

Photodiode Signal Conditioning

The INA116PAG4 can condition weak photodiode currents because its 3 fA typical input bias current minimizes error contributed by the amplifier itself. The adjustable gain of 1 to 1000 provides room to amplify the photodiode voltage before a downstream converter or controller. Layout remains decisive: route the photodiode input directly to the relevant pins, use the guard-drive structure correctly, and provide stable bypass capacitance. Because the device is optimized for low bias current rather than unlimited bandwidth, photodiode capacitance and settling requirements must be checked against the selected gain.

🔧

Laboratory Bridge Amplifier

The INA116PAG4 is well suited to laboratory bridge measurements where a small sensor-generated differential voltage must be measured in the presence of a substantial common-mode voltage. The 94 dB CMRR suppresses common-mode noise, while the low input bias current avoids disturbing resistive bridges and other high-impedance sources. Use one external gain resistor to establish the required gain, route the bridge return separately from output ground, and verify output headroom before selecting a high gain. The device’s single-ended output simplifies connection to oscilloscopes, data converters, and external ADC front ends.

🧪

Electrochemical Sensor Front End

The INA116PAG4 is suitable for electrochemical and other chemical sensors that produce a small differential signal and have high source impedance. Its 3 fA typical input bias current at 25°C minimizes amplifier-generated error, and the selectable gain from 1 to 1000 accommodates signals spanning widely different concentrations. The buffered guard pins are particularly relevant because contamination and moisture on a PCB can create leakage paths comparable to the sensor current. Follow the recommended guarding layout, protect sensitive nodes from contamination, and include an input protection strategy that respects the ±40 V maximum input rating.

🏭

Industrial Process Measurement

The INA116PAG4 can amplify low-level process signals when the design requires low input bias current and strong rejection of common-mode voltage. Its 94 dB CMRR supports measurements taken above ground, while the adjustable closed-loop gain simplifies scaling from millivolts to a usable analog output. For industrial equipment, include transient protection, verify the common-mode range at the chosen gain, and provide local bypass capacitance close to the supply pins. The instrument-amplifier topology integrates three amplifiers, so PCB symmetry and clean return routing are important for preserving common-mode performance.

What is the INA116PAG4?
The INA116PAG4 is a Texas Instruments precision instrumentation amplifier designed to amplify small differential signals while rejecting common-mode interference. According to the manufacturer datasheet, it uses a DIFET input stage, provides a typical input bias current of 3 fA at 25°C, supports gains from 1 to 1000, and is offered in a 16-pin PDIP package. It is primarily used for high-impedance sensing and precision measurement.
What are the key specifications of INA116PAG4 that engineers should know?
The INA116PAG4 combines a typical 3 fA input bias current at 25°C, 2 mV maximum input offset voltage, 94 dB common-mode rejection, 800 kHz bandwidth, and a 0.08 V/µs slew rate. According to the Texas Instruments datasheet, its differential gain is adjustable from 1 to 1000 using an external gain resistor, while its ±4.5 V to ±18 V supply range supports dual- and single-supply arrangements as permitted by the application.
Where can I download the INA116PAG4 datasheet PDF?
The official INA116PAG4 technical documentation is available through the Texas Instruments INA116 product page linked on this page. The manufacturer datasheet contains the electrical characteristics, gain-selection equation, pin descriptions, guard-drive guidance, typical application circuit, and recommended operating conditions. Use the ordering information associated with the 16-pin PDIP package to identify the correct INA116 variant and confirm its lifecycle status before beginning a new design.
Where can I find the INA116PAG4 pinout?
The INA116PAG4 pin assignment is documented in the pin-configuration section of the Texas Instruments INA116 datasheet. The device uses a 16-pin PDIP package, and its external connections include the differential inputs, gain-setting resistor, power terminals, output, and guard-drive pins. Use the manufacturer pin table when assigning PCB tracks and connecting the gain resistor, because the guard connections are not general-purpose signal inputs and are intended for leakage-control routing.
Why is the low input bias current of INA116PAG4 important?
The 3 fA typical input bias current at 25°C is important because it minimizes the current drawn from high-impedance sources. According to the Texas Instruments datasheet, bias current increases to 25 fA at 85°C, so leakage and PCB cleanliness remain significant at elevated temperatures. This makes the INA116PAG4 suitable for sensor, photodiode, electrochemical-cell, and precision shunt measurements where source resistance is high.
How is the gain set on an INA116PAG4?
The INA116PAG4 gain is set with one external resistor connected between its designated gain-setting terminals. According to the manufacturer datasheet, the device supports gains from 1 to 1000. The practical usable bandwidth falls as gain increases, so the selected resistor must satisfy both the intended gain and the required signal bandwidth. Place the gain resistor close to the amplifier and avoid routing the sensitive input nodes through long traces.
What common-mode voltage can the INA116PAG4 accept?
The INA116PAG4 accepts differential input signals within its specified common-mode range, but the exact usable range depends on the selected gain and supply voltage. According to the Texas Instruments datasheet, the maximum input voltage is ±40 V, while the low-input-bias-current operating region also depends on the input configuration. Use the manufacturer input common-mode versus output-voltage plots to verify the operating point rather than inferring it from the ±40 V maximum alone.
How should the INA116PAG4 guard-drive pins be used?
The INA116PAG4 guard-drive pins should be connected according to the manufacturer guarding layout so they reduce leakage caused by surface contamination or PCB insulation. According to the Texas Instruments datasheet, these pins are buffered guard outputs rather than ordinary amplifier outputs. Route them to the appropriate input-guard structures, keep sensitive input traces short, and avoid using the guard pins as general-purpose shield or signal outputs.
Can the INA116PA replace the INA116PAG4?
The INA116PA is the closest documented option for a same-family replacement because it is also listed as a Texas Instruments single instrumentation amplifier in a 16-pin PDIP package with 800 kHz bandwidth and 94 dB CMRR. A component cross-reference is not a substitute for a manufacturer pinout check, so confirm the exact ordering suffix, pin assignment, electrical limits, and guard-pin implementation before treating it as a drop-in replacement.
What is the best drop-in replacement for INA116PAG4?
No cross-manufacturer drop-in replacement can be confirmed from the available component information. The INA116PA is the nearest same-family candidate because it shares the 16-pin PDIP format and major listed characteristics, including 800 kHz bandwidth and 94 dB CMRR, but every alternative should still be checked against the Texas Instruments pinout and electrical tables. Use the Request a Quote form on this page to ask about exact-fit sourcing and lifecycle options.
When should I choose INA116PAG4 over a conventional operational amplifier?
Choose the INA116PAG4 when the source is high impedance and the measurement requires excellent common-mode rejection, very low input bias current, and simple gain selection. A conventional operational amplifier may require several precision resistors and separate input-bias-current compensation, while the INA116 integrates a three-op-amp instrumentation topology in one package. Its 3 fA typical input bias current is the decisive advantage for sensitive sensors.
Is INA116PAG4 suitable for precision current-shunt measurement?
The INA116PAG4 is suitable for precision current-shunt measurement when the differential signal and common-mode voltage remain within the manufacturer’s operating limits. Its 2 mV maximum input offset voltage, 94 dB CMRR, and adjustable gain support accurate low-level voltage measurement. Because a shunt measurement can be affected by resistor tolerance, Kelvin routing, ground offsets, and amplifier offset, use a four-wire connection and account for offset in the system error budget.
What is the lead time for INA116PAG4?
Current lead time and minimum order quantity for the obsolete INA116PAG4 should be confirmed directly through the Request a Quote form on this page. The product is identified as discontinued in distributor records, so allocation may depend on remaining factory or inventory stock rather than routine production. Provide the required package, quantity, and target date with the request to obtain the most useful supply response.
Where can I buy INA116PAG4 online?
Use the Request a Quote form on this page to request INA116PAG4 pricing, stock, and lead-time information. Because the INA116PAG4 is an obsolete 16-pin PDIP device, its availability may be limited and may change without notice. State the required quantity, tube packaging, target delivery date, and any acceptable alternate sourcing conditions when submitting the request.
What is the price of INA116PAG4?
The current INA116PAG4 price is not shown as a static figure because obsolete-part pricing and availability can change quickly. Use the Request a Quote form on this page to obtain a current quotation for the exact 16-pin PDIP ordering code. Include the required quantity and packaging preference, and ask for allocation and lead-time confirmation in the same request so the quote reflects a usable supply plan.
Is INA116PAG4 the same as INA116PA?
The INA116PAG4 and INA116PA belong to the same INA116 family and are listed in the same 16-pin PDIP format, but their ordering suffixes can encode different qualification, packaging, or terminal-finish details. According to the Texas Instruments ordering information, engineers should compare the exact suffix codes, pinout, operating limits, and lifecycle terms. The available comparison identifies major similarities but does not establish universal interchangeability.

엔지니어링 참조 데이터: INA116PAG4 — 비교, 설계 지침 및 규정 준수 정보.

선택 가이드

Choose the INA116PAG4 for legacy or maintenance designs that specifically require a 16-pin PDIP Texas Instruments instrumentation amplifier with extremely low input bias current, a gain range of 1 to 1000, and buffered guard-drive support. It is especially appropriate for high-impedance sensors, electrochemical cells, photodiode interfaces, and precision shunts where picoampere-to-femtoampere input currents affect accuracy. The INA116PA is the nearest documented same-family alternative because it shares the 16-pin PDIP format and major listed specifications, but engineers must verify its exact suffix details, pin functions, operating limits, and lifecycle terms before substituting it. Do not choose a conventional operational amplifier merely for a lower-cost implementation: building a matched three-amplifier network can increase component count, resistor-tolerance error, and board area. If the design requires newer electrical limits, lower offset, different supply capability, or a package other than PDIP, perform a fresh component selection rather than treating a family similarity as a guaranteed drop-in replacement.

대체품과의 비교

파라미터 이 제품 INA116PA
Brand Texas Instruments Texas Instruments
Package 16-pin PDIP 16-pin PDIP
Product Type Instrumentation amplifier Instrumentation amplifier
Number of Amplifiers 1 circuit 1 circuit
Bandwidth 800 kHz 800 kHz
Common-Mode Rejection Ratio 94 dB 94 dB
Input Offset Voltage 5 mV typical 5 mV
Slew Rate 0.08 V/µs 0.08 V/µs
Supply Voltage Range ±4.5 V to ±18 V ±4.5 V to ±18 V

주요 차별점

  • Exceptionally low input bias current (vs INA116PA)
  • Integrated precision gain setting (vs INA116PA)
  • Common-mode rejection suited to noisy industrial signals (vs INA116PA)

설계 노트

Route the differential inputs and gain resistor as short, guarded traces, with the gain resistor located immediately across the designated pins. For high-impedance sources, reproduce the manufacturer’s guard-drive connection rather than treating the guard pins as ordinary outputs. Contamination, solder residue, and moisture can create leakage comparable to the device’s femtoampere-scale bias current, so clean the board and keep high-impedance nodes away from dirty or condensing areas.

Do not select the gain solely from the maximum value of 1000. The usable bandwidth falls as closed-loop gain increases, so verify the required signal bandwidth and settling behavior against the gain selected. Also distinguish the ±40 V maximum input rating from the operating common-mode range. The input must remain within both the absolute maximum and the functional common-mode limits at the installed gain and supply voltage.

Place the manufacturer-recommended bypass capacitors close to the supply pins and keep supply-current returns compact to prevent parasitic inductance from converting output switching into supply noise. The INA116PAG4 accepts ±4.5 V to ±18 V supplies, but the usable input and output ranges depend on the selected gain. Verify common-mode headroom, output swing, and dual-supply sequencing before applying a bipolar input source.

For low-level shunt or sensor measurements, use a true differential route and separate the Kelvin return from the power ground path. Avoid sharing copper between the shunt return and sensitive output reference where possible. Include offset, bias-current error, resistor mismatch, and common-mode error in the total accuracy calculation; the listed 2 mV maximum input offset voltage alone does not represent the complete measurement uncertainty.

규정 준수 정보

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
무연
Unknown
무할로겐
Unknown
분쟁 광물
Unknown

The component is described as a Green product, but explicit RoHS, REACH, lead-free, halogen-free, conflict-minerals, and automotive qualification statements are not stated in the available product information. AEC-Q100 is not applicable to the listed general-purpose device.

데이터 검증일: 2026-11-14 — XAIPART 부품 엔지니어링 팀이 검증하고 관리한 데이터

관련 검색

INA116PAG4 datasheet INA116PAG4 pinout INA116PAG4 datasheet pdf INA116PAG4 equivalent INA116PAG4 replacement INA116PAG4 vs INA116PA INA116PAG4 DIP-16 pinout INA116PAG4 application circuit INA116PAG4 price INA116PAG4 stock Texas Instruments INA116PAG4 INA116PAG4 3 fA bias current

관련 부품 & 용어

Texas Instruments INA116PAG4 INA116PA INA116 instrumentation amplifier precision analog IC signal-chain IC semiconductor DIFET FET input input bias current common-mode rejection ratio CMRR gain-bandwidth relationship buffered guard drive 16-pin PDIP PDIP package family through-hole mount high-impedance sensor precision current shunt electrochemical sensor photodiode interface RoHS AEC-Q100
빠른 견적 RFQ
상세 정보를 모두 입력하십시오 — 영업팀이 24시간 이내에 답변드립니다
부품 번호 제조사 패키지 QTY 목표 가격 합계
✓
견적이 제출되었습니다!

24시간 이내에 이메일로 답변드리겠습니다

1
RFQ 제출됨
2
견적 접수됨
3
주문 완료
4
결제
5
배송됨
6
배송 완료
RFQ 상세 보기