MAX3243CAI+G1Z - 3/5 RS-232 Transceiver | Analog Devices
部品番号: MAX3243CAI+G1Z ✓ 生産中MAX3243CAI+G1Z 概要
An RS-232 transceiver is an interface IC that converts logic-level digital signals into RS-232 voltage levels and converts incoming RS-232 signals back into logic-compatible levels. The MAX3243 belongs to the broader interface IC hierarchy, where line drivers and receivers bridge modern digital systems with older RS-232 equipment. Its multi-channel arrangement supports equipment needing more drivers or receivers than a simple two-channel RS-232 implementation.
The MAX3243 family includes integrated charge-pump circuitry for level translation, allowing operation from a single low-voltage supply rather than the traditional positive and negative RS-232 supplies. Low-power operation is important in portable equipment, industrial control systems, and instrument panels where an idle RS-232 port should not consume significant power. AutoShutdown provides automatic supply reduction when valid receiver activity is absent, supporting efficient power management without requiring a dedicated GPIO control signal.
The MAX3243 is suitable for industrial control equipment, test and measurement instruments, data acquisition systems, security equipment, and service interfaces. Its always-active receiver channels can monitor external RS-232 activity even while the principal receiver channels are shut down, which is useful for detecting connection or activity status. The 28-pin SSOP package also supports compact board layouts in legacy and industrial communication products.
When designing around the MAX3243CAI+G1Z, verify the 3 V to 5.5 V supply range, connector protection requirements, and the voltage levels present at each interface. RS-232 is a single-ended, unbalanced standard, so cable routing and grounding can affect signal integrity. Keep connector-side transient protection close to the connector and use the pin-description table in the manufacturer datasheet when assigning PCB tracks. AutoShutdown behavior should also be checked against the system’s expected idle state and remote-device signaling.
This page combines the family-level electrical characteristics, package information, sourcing context, drop-in alternatives, and practical RS-232 design guidance to support component selection and PCB implementation.
ドロップイン代替品: MAX3243CAI+G1Z — 同一パッケージでピン互換。PCBの作り直しが必要な異なるパッケージの部品は除外されています。
このシリーズのバリエーション
同一シリーズでドロップイン互換のモデル: MAX3243CAI+G1Z (同一形状・フットプリント) — 相違点: ESD Protection, Product Type, Maximum Data Rate, Package, Supply Voltage Range.
MAX3243CAI+
✅ ドロップイン📋 参考代替品(カタログ未掲載)
MAX3243EEUI+T
✅ ドロップイン価格はお問い合わせください
データシートを見る →MAX3243EAI+T
✅ ドロップイン ⚠️ 仕様未検証📋 参考代替品(カタログ未掲載)
MAX3243ECAI+T
✅ ドロップイン ⚠️ 仕様未検証価格はお問い合わせください
データシートを見る →MAX3237CAI+T
✅ ドロップイン📋 参考代替品(カタログ未掲載)
MAX3243CAI+G1Z 仕様
| Product Type | RS-232 interface transceiver |
| Driver Count | 3 drivers |
| Receiver Count | 5 receivers |
| Supply Voltage Range | 3 V to 5.5 V |
| AutoShutdown Supply Current | 1 uA |
| Maximum Data Rate | 250 kbps |
| ESD Protection | +/-15 kV |
| Always-Active Receiver Channels | 1 complementary receiver |
| パッケージ | 28-pin SSOP |
| 実装タイプ | Surface mount |
| Supply Type | Single supply |
| Transceiver Configuration | 3/5 full RS-232 |
MAX3243CAI+G1Z 28-pin ssop ピン配置ガイド
MAX3243CAI+G1Z (28-pin ssop パッケージ) のピン配置。 ピン番号、機能、接続図はメーカーのデータシートで定義されています。正確なフットプリントとはんだ付けのガイドラインについては、データシートを参照してください。
詳細なピン配置データはありません: MAX3243CAI+G1Z.
詳細は データシート をご参照ください。
主な用途
MAX3243CAI+G1Z の用途: 6 件s: Industrial Control Interfaces, Test and Measurement Equipment, Data Acquisition Systems, Security and Access Equipment, Portable Service and Diagnostic Tools, Embedded Service and Configuration Ports.
Industrial Control Interfaces
The MAX3243CAI+G1Z fits legacy RS-232 control ports used by industrial machinery, programmable controllers, and service equipment. Its single 3 V to 5.5 V supply simplifies interface design in systems that no longer provide separate positive and negative RS-232 rails. Three drivers support command or control outputs, while five receivers can accept status, acknowledgment, and sensor information. The 1 uA AutoShutdown state reduces idle consumption when no valid receiver activity is present, which is particularly useful in continuously powered but intermittently connected equipment. Designers should verify logic-level compatibility, line thresholds, and exact receiver functions in the manufacturer pin description table.
おすすめ
Test and Measurement Equipment
Instrumentation using RS-232 for remote control and status reporting can use the MAX3243CAI+G1Z as a compact multi-channel interface. The 250 kbps maximum data rate suits conventional serial-control protocols, while the three drivers and five receivers provide more channel flexibility than a two-driver transceiver. AutoShutdown helps maintain low power during idle intervals between commands, and the complementary always-active receiver can monitor a connection or external RS-232 activity. The 28-pin SSOP package also supports dense control-panel layouts. Confirm the instrument’s logic thresholds, handshake requirements, and connector-side transient protection against the complete family datasheet.
おすすめ
Data Acquisition Systems
The MAX3243CAI+G1Z can connect a data-acquisition controller to external RS-232 instruments or legacy sensors. Five receiver channels allow multiple status or measurement signals to be monitored, while three driver channels provide command and handshake outputs. Its single-supply operation and integrated charge-pump circuitry eliminate the need for a separate bipolar RS-232 supply generator. When the system spends substantial time waiting for data, AutoShutdown can reduce supply current to 1 uA after the receiver inputs stop showing valid activity. Preserve the intended idle behavior, particularly if a remote device requires a continuously asserted output or uses unusual line levels.
おすすめ
Security and Access Equipment
Access-control panels, readers, and alarm interfaces that retain an RS-232 diagnostic port can benefit from the MAX3243CAI+G1Z’s combination of multiple drivers, multiple receivers, and automatic low-power operation. The extra receiver channels can monitor door contacts, controller responses, or peripheral status without requiring identical channels. A 3.3 V system can operate the interface from the same supply domain, reducing level-conversion complexity. ESD protection of +/-15 kV adds useful transient immunity at the device level, although the external connector still requires suitable protection and proper chassis grounding. Verify the security equipment’s isolation, surge, and grounding requirements before deployment.
おすすめ
Portable Service and Diagnostic Tools
A portable diagnostic tool powered from a single low-voltage source can use the MAX3243CAI+G1Z to communicate with legacy RS-232 service ports. The device operates from 3 V to 5.5 V, which supports both 3.3 V and 5 V portable designs, and its 1 uA AutoShutdown current helps conserve energy between diagnostic sessions. The always-active complementary receiver can provide a wake or activity indication without keeping every transmitter powered. Designers should evaluate whether AutoShutdown thresholds match the target equipment’s valid RS-232 levels and add cable transients or protection networks where a long external cable creates additional risk.
おすすめ
Embedded Service and Configuration Ports
Embedded systems often require a service port that remains compatible with older configuration tools. The MAX3243CAI+G1Z provides three transmit channels and five receive channels within a 28-pin SSOP, allowing command, acknowledgement, and diagnostic signals to share one device. Its integrated charge-pump circuit supports RS-232 levels from one supply, reducing the number of external support components. The additional receiver capacity can support boot-mode detection, status polling, or a permanently monitored external signal. Confirm the host UART logic levels and timing, and follow the manufacturer datasheet for charge-pump capacitor selection and pin placement.
おすすめ
おすすめ製品の概要
エンジニアリング参考データ: MAX3243CAI+G1Z — 比較、設計ガイダンス、コンプライアンス情報。
選定ガイド
代替品との比較
| パラメータ | この製品 | MAX3243CAI+ | MAX3243EEUI+T | MAX3243EAI+T | MAX3243ECAI+T | MAX3237CAI+T |
|---|---|---|---|---|---|---|
| Package | 28-pin SSOP | 28-pin SSOP | 28-pin SSOP | 28-pin SSOP | 28-pin SSOP | 28-pin SSOP |
| Brand | Analog Devices | Analog Devices | Analog Devices | Analog Devices | Analog Devices | Analog Devices |
| Transceiver Family | MAX3243 | MAX3243 | MAX3243 | MAX3243 | MAX3243 | MAX3237 |
主な差別化要因
- Higher receiver count than a basic two-channel RS-232 interface (vs MAX3237CAI+T)
- Direct same-family ordering alternative (vs MAX3243EEUI+T)
- Automatic low-power operation with monitoring capability (vs MAX3237CAI+T)
設計ノート
Route the three driver outputs and five receiver inputs according to the manufacturer pin-description table, and place the required charge-pump capacitors close to their designated pins. Keep the RS-232 connector-side protection network close to the connector so surge current is diverted before it reaches the transceiver. Preserve the 28-pin SSOP footprint and avoid changing package or temperature-grade suffix codes during PCB release.
Decouple the 3 V to 5.5 V supply locally with the capacitor values and placement specified by the manufacturer datasheet. Confirm that the host UART operates at a logic level compatible with the MAX3243 input and output thresholds. AutoShutdown can reduce quiescent current to 1 uA, but verify that valid receiver levels and the always-active complementary receiver behave as required during system idle periods.
Do not treat the MAX3243CAI, MAX3243CAI+G1Z, and MAX3243CAI+TG1Z identifiers as interchangeable without checking the order code and packaging suffix. Also avoid assuming that every 28-pin SSOP RS-232 transceiver is interchangeable: MAX3237-family channel assignments and shutdown behavior can differ. Validate pin functions, temperature grade, logic thresholds, and AutoShutdown timing before approving a substitution.
コンプライアンス情報
The +G1Z ordering suffix denotes a lead-free commercial variant. RoHS, REACH, halogen-free, and conflict-minerals status require confirmation from the current manufacturer product documentation.