MCP3426A2-E/MC - 16-Bit Dual-Channel Delta-Sigma ADC
部品番号: MCP3426A2-E/MC ✓ 生産中MCP3426A2-E/MC 概要
A delta-sigma ADC is a type of analog-to-digital converter that uses oversampling, noise shaping, and digital filtering to convert a differential analog input into a high-resolution digital code. Within the electronics hierarchy, the MCP3426 belongs to the ADC class, the analog-to-digital converter category, and the broader data-converter and semiconductor families. Its differential inputs and integrated reference make it suitable for low-level instrumentation where signal polarity and measurement accuracy are important.
The MCP3426A2-E/MC provides two analog input channels, up to 16-bit resolution, and a differential input range of ±2.048 V when using the internal 2.048 V reference. This 4096 mV differential span allows both positive and negative input voltages to be represented without separate single-ended conversion stages. Two-wire communication reduces the number of interface pins required on compact sensor, industrial, and automotive measurement boards.
The delta-sigma architecture prioritizes low noise and high accuracy rather than the highest continuous conversion rate. Single-conversion operation supports rates up to 240 SPS, while continuous conversion is identified as operating at 15 SPS. A dual-channel implementation can reduce the number of separate converters required when two related sensors must be digitized, although channel multiplexing and acquisition timing should be checked in the system design.
Typical uses include bridge and strain-gauge measurements, battery-cell monitoring, current sensing, industrial process control, portable instrumentation, and automotive sensor acquisition. Differential input architecture helps reject common-mode noise when the sensor output is referenced to a local return rather than the converter ground. The small exposed-pad DFN package also supports compact PCB layouts, but its exposed thermal pad must be connected according to the manufacturer land pattern.
For a robust layout, route the analog inputs away from digital clocks and switching power nodes, place input filtering components close to the ADC pins, and use a quiet ground reference for the measurement path. Verify the acquisition timing, conversion-rate mode, digital filter settling time, and I2C clock timing before choosing the operating mode. The exposed pad should be connected to the appropriate ground plane to improve thermal performance and reduce package-related stress.
This product overview combines the manufacturer’s device specifications with practical guidance for PCB layout, signal conditioning, differential measurement, and source selection. It also organizes compatible same-family options and their factory-programmed I2C-address differences, helping engineers identify the correct replacement before committing a PCB revision.
ドロップイン代替品: MCP3426A2-E/MC — 同一パッケージでピン互換。PCBの作り直しが必要な異なるパッケージの部品は除外されています。
このシリーズのバリエーション
同一シリーズでドロップイン互換のモデル: MCP3426A2-E/MC (同一形状・フットプリント) — 相違点: Package, Differential Input Range, Digital Interface, Resolution, Supply Voltage.
MCP3426A0T-E/MC
✅ ドロップイン ⚠️ 仕様未検証📋 参考代替品(カタログ未掲載)
MCP3426A3T-E/MC
✅ ドロップイン ⚠️ 仕様未検証📋 参考代替品(カタログ未掲載)
MCP3426A6T-E/MC
✅ ドロップイン ⚠️ 仕様未検証📋 参考代替品(カタログ未掲載)
MCP3426A7T-E/MC
✅ ドロップイン📋 参考代替品(カタログ未掲載)
MCP3426A2-E/MC 最大定格&電気的特性
| ADC Type | Delta-sigma (ΣΔ) |
| 分解能 | Up to 16 bit |
| Number of Input Channels | 2 channels |
| Input Architecture | Differential inputs |
| Internal Reference Voltage | 2.048 V |
| Differential Input Range | ±2.048 V |
| Maximum Conversion Rate | 240 SPS |
| Continuous Conversion Rate | 15 SPS |
| Digital Interface | Two-wire I2C |
| 電源電圧 | 3.3 V or 5 V |
| パッケージ | 8-pin DFN with exposed pad, 2 x 3 mm |
| 実装タイプ | Surface mount |
| Automotive Qualification | AEC-Q100 |
MCP3426A2-E/MC 8-pin dfn with exposed pad, 2 x 3 mm ピン配置ガイド
MCP3426A2-E/MC (8-pin dfn with exposed pad, 2 x 3 mm パッケージ) のピン配置。 このアナログコンポーネントは、入力、出力、および電源ピンを備えています。オフセットナル、補償、イネーブルピンの設定については、メーカーのデータシートを参照してください。信号調整やアンプ回路に最適です。
詳細なピン配置データはありません: MCP3426A2-E/MC.
詳細は データシート をご参照ください。
主な用途
MCP3426A2-E/MC の用途: 6 件s: Strain-Gauge and Bridge Sensor Measurement, Battery Cell Voltage Monitoring, Industrial Current and Voltage Sensing, Automotive Sensor Acquisition, Portable Environmental Monitoring, Test and Measurement Instrumentation.
Strain-Gauge and Bridge Sensor Measurement
The MCP3426A2-E/MC fits bridge-based strain and pressure measurements because it combines two differential input channels with up to 16-bit resolution and a 2.048 V internal reference. A bridge output can be measured relative to its excitation return, reducing sensitivity to common-mode voltage in industrial wiring. The 15 SPS continuous mode supports stable low-rate monitoring, while a 240 SPS single conversion can support triggered measurements. Place input protection and filtering close to the pins, and verify excitation settling before the converter samples the bridge.
おすすめ
Battery Cell Voltage Monitoring
The MCP3426A2-E/MC is appropriate for multi-cell battery monitoring when paired with a suitable front end and measurement strategy. Its two differential channels permit measurement of a cell stack relative to a local tap, while the ±2.048 V differential span is useful for scaled battery dividers. The 16-bit resolution supports precise state-of-charge estimation, and the I2C interface supports frequent digital updates. Care must be taken with absolute pin voltage, cell-isolation boundaries, filtering, and ground references because the ADC itself does not provide galvanic isolation.
おすすめ
Industrial Current and Voltage Sensing
The MCP3426A2-E/MC can digitize differential outputs from current shunts, isolated amplifiers, and precision divider networks. Differential inputs help reject ground offsets and common-mode voltage present on industrial wiring, while the 2.048 V internal reference simplifies calibration. Two channels allow related voltage and current measurements to be acquired with one compact converter. The design should use low-thermal-resistance shunt elements, anti-alias filters near the ADC, and a layout that keeps high-current paths separate from the analog input and reference return.
おすすめ
Automotive Sensor Acquisition
The MCP3426A2-E/MC is suitable for compact automotive sensor acquisition where differential input signals, low noise, and AEC-Q100 identification are important. Its two channels can support paired pressure, temperature, or position sensor measurements, and the 240 SPS single-conversion mode suits event-triggered sampling. The 8-pin DFN exposed-pad package limits board area, although exposed-pad soldering and thermal cycling require careful process control. Confirm the exact temperature grade and automotive qualification status for the production design.
おすすめ
Portable Environmental Monitoring
The MCP3426A2-E/MC fits portable environmental instruments that monitor slow-moving signals such as gas, humidity, pressure, or temperature transducers. The 15 SPS continuous mode provides periodic digital updates without the power burden of a fast flash ADC, and the I2C interface allows a microcontroller to retrieve both differential channels efficiently. Its small 2 x 3 mm DFN package supports compact products. Designers should use low-leakage filtering components, maintain a quiet analog ground reference, and account for sensor excitation settling after each conversion cycle.
おすすめ
Test and Measurement Instrumentation
The MCP3426A2-E/MC is useful in laboratory and field instruments requiring two low-level differential measurements with up to 16-bit resolution. The integrated 2.048 V reference provides a defined conversion scale, and single conversions can be triggered when variable throughput is needed. I2C simplifies connection to a controller while leaving pins available for front-end controls. For accurate measurements, derive reference and excitation requirements from the external circuit, calibrate gain and offset, and isolate analog routing from digital activity to preserve the converter’s low-noise performance.
おすすめ
おすすめ製品の概要
エンジニアリング参考データ: MCP3426A2-E/MC — 比較、設計ガイダンス、コンプライアンス情報。
選定ガイド
代替品との比較
| パラメータ | この製品 | MCP3426A0T-E/MC | MCP3426A3T-E/MC | MCP3426A6T-E/MC | MCP3426A7T-E/MC |
|---|---|---|---|---|---|
| Brand | Microchip Technology | Microchip Technology | Microchip Technology | Microchip Technology | Microchip Technology |
| Package | 8-DFN (2x3) with exposed pad | 8-DFN (2x3) with exposed pad | 8-DFN (2x3) with exposed pad | 8-DFN (2x3) with exposed pad | 8-DFN (2x3) with exposed pad |
| Resolution | Up to 16 bit | Up to 16 bit | Up to 16 bit | Up to 16 bit | Up to 16 bit |
| Input Channels | 2 differential channels | 2 differential channels | 2 differential channels | 2 differential channels | 2 differential channels |
| ADC Architecture | Delta-sigma | Delta-sigma | Delta-sigma | Delta-sigma | Delta-sigma |
| Internal Reference | 2.048 V | 2.048 V | 2.048 V | 2.048 V | 2.048 V |
| Differential Input Range | ±2.048 V | ±2.048 V | ±2.048 V | ±2.048 V | ±2.048 V |
| Maximum Conversion Rate | 240 SPS | 240 SPS | 240 SPS | 240 SPS | 240 SPS |
| Continuous Conversion Rate | 15 SPS | 15 SPS | 15 SPS | 15 SPS | 15 SPS |
| Digital Interface | Two-wire I2C | Two-wire I2C | Two-wire I2C | Two-wire I2C | Two-wire I2C |
| Factory-Programmed I2C Address | A2 address code | A0 address code | A3 address code | A6 address code | A7 address code |
主な差別化要因
- Combines two differential channels with up to 16-bit resolution (vs MCP3426A7T-E/MC)
- Uses the A2 factory-programmed I2C address code (vs MCP3426A0T-E/MC)
- Provides a defined differential input span without external reference wiring (vs MCP3426A6T-E/MC)
- Supports 240 SPS triggered measurements and 15 SPS continuous conversion (vs MCP3426A3T-E/MC)
設計ノート
Route the two differential inputs as short, tightly coupled traces and keep them away from I2C clock lines, switching nodes, and high-current return paths. Place input resistors or capacitors at the ADC side of the board so that ESD and surge-current energy is diverted before reaching the pins. Maintain a continuous analog ground reference beneath the measurement section and follow the manufacturer’s exposed-pad land pattern with thermal vias where the PCB process permits.
The MCP3426A2-E/MC can accept differential input voltages of ±2.048 V with the internal reference, but the common-mode voltage and absolute maximum pin limits remain separate constraints. Verify the sensor output during startup, fault, and shutdown states before applying protection components. Use low-leakage protection parts when measuring high-impedance sources, and place filtering close to the ADC rather than beside the sensor.
Do not treat the 240 SPS single-conversion capability as a sustained continuous conversion rate. The continuous mode is identified as 15 SPS, and digital-filter settling must be included in the measurement schedule. Also verify the factory-programmed I2C address before substitution: changing from the A2 code to A0, A3, A6, or A7 can prevent the controller from communicating even when the PCB footprint remains unchanged.
コンプライアンス情報
Distributor product information identifies MCP3426A2-E/MC as an automotive AEC-Q100 device. RoHS, REACH, lead-free, halogen-free, and conflict-minerals declarations were not established from the available manufacturer and distributor information.