MCP3426A4-E/MS - 16-Bit Dual-Channel 15 SPS ADC | Microchip
部品番号: MCP3426A4-E/MS ✓ 生産中MCP3426A4-E/MS 概要
A delta-sigma ADC is an analog-to-digital converter category that uses continuous-time oversampling and digital filtering to deliver high resolution from a low-noise analog front end. The MCP3426 belongs to the broader hierarchy of ADC, data-converter IC, signal-conditioning semiconductor, and analog measurement device. Its differential inputs can reject common-mode disturbance when paired with suitable sensor arrangements, while the integrated reference simplifies calibration and reduces the number of external precision components.
The MCP3426A4 provides up to 16-bit resolution, two analog input channels, and a 15 SPS conversion rate. Its differential input range extends to ±2.048 V when the internal 2.048 V reference is selected. The converter is optimized for low-noise measurements rather than high-speed waveform capture. Separate analog and digital supply connections also allow a mixed-signal board to control analog and digital supply paths independently, provided each supply remains within its specified operating range.
The converter uses a one-channel delta-sigma signal chain with digital filtering to achieve accurate results at low sample rates. This architecture is appropriate for temperature, pressure, strain, potentiometer, and slow process-control signals where resolution and input-noise performance matter more than high conversion bandwidth. The integrated reference and two differential-capable input channels reduce the need for external signal-conditioning hardware in many measurement circuits.
Typical uses include industrial process monitoring, laboratory data acquisition, environmental sensors, bridge-based pressure measurement, and battery-powered instrumentation. The 2.7 V to 5.5 V supply range supports both 3.3 V and 5 V systems. For designs operating from a regulated 5 V rail, the converter can also support the 2.048 V differential range around ground when the input and reference configuration permits it.
Designers should pay close attention to input common-mode voltage, source impedance, filtering, grounding, and decoupling. A high-impedance sensor or resistive divider can require a longer sampling interval than the nominal conversion rate. Place the input and reference components close to the associated pins, maintain the analog and digital return paths separately, and follow the manufacturer datasheet for recommended capacitor values and layout.
This page combines the exact MCP3426A4-E/MS configuration, package information, family alternatives, commercial sourcing guidance, and practical analog-design considerations. It also distinguishes true same-package options from wider ADC choices that may require different boards, interfaces, or external circuitry.
ドロップイン代替品: MCP3426A4-E/MS — 同一パッケージでピン互換。PCBの作り直しが必要な異なるパッケージの部品は除外されています。
このシリーズのバリエーション
同一シリーズでドロップイン互換のモデル: MCP3426A4-E/MS (同一形状・フットプリント) — 相違点: Differential Input Range, Package, Input Channels, Input Configuration, Maximum Conversion Rate.
MCP3426A4T-E/MS
✅ ドロップイン📋 参考代替品(カタログ未掲載)
MCP3426A5-E/MS
✅ ドロップイン📋 参考代替品(カタログ未掲載)
MCP3426A1T-E/MS
✅ ドロップイン📋 参考代替品(カタログ未掲載)
MCP3426A0-E/MS
✅ ドロップイン価格はお問い合わせください
データシートを見る →MCP3426A1-E/MS
✅ ドロップイン ⚠️ 仕様未検証価格はお問い合わせください
データシートを見る →MCP3426A4-E/MS 最大定格&電気的特性
| ADC Resolution | 16 bit |
| Input Channel Count | 2 channels |
| Conversion Architecture | 1-channel delta-sigma ADC |
| Maximum Conversion Rate | 15 samples/s |
| Input Type | 2 differential-capable analog inputs |
| Internal Reference Voltage | 2.048 V |
| Differential Input Range | ±2.048 V |
| Minimum Supply Voltage | 2.7 V |
| Maximum Supply Voltage | 5.5 V |
| Minimum Operating Temperature | -55 °C |
| Maximum Operating Temperature | 125 °C |
| パッケージ | 8-MSOP |
| ピン数 | 8 pins |
| 実装タイプ | Surface mount |
MCP3426A4-E/MS 8-msop ピン配置ガイド
MCP3426A4-E/MS (8-msop パッケージ) のピン配置。 このアナログコンポーネントは、入力、出力、および電源ピンを備えています。オフセットナル、補償、イネーブルピンの設定については、メーカーのデータシートを参照してください。信号調整やアンプ回路に最適です。
詳細なピン配置データはありません: MCP3426A4-E/MS.
詳細は データシート をご参照ください。
主な用途
MCP3426A4-E/MS の用途: 6 件s: Industrial Process Monitoring, Pressure and Strain Measurement, Environmental Sensor Acquisition, Laboratory Data Acquisition, Battery-Powered Instrumentation, Precision Potentiometer Measurement.
Industrial Process Monitoring
The MCP3426A4-E/MS fits slow industrial process signals that require more resolution than a conventional low-cost converter but do not need rapid acquisition. Its 16-bit resolution, two analog channels, and 15 samples/s rate support pressure, flow, level, and temperature monitoring. Differential inputs can reduce common-mode pickup when the sensor and return paths are balanced, while the integrated 2.048 V reference simplifies excitation and measurement calibration. The principal design consideration is ensuring that every signal remains inside the converter's common-mode and input limits throughout the process range.
おすすめ
Pressure and Strain Measurement
The MCP3426A4-E/MS is appropriate for bridge-based pressure and strain instrumentation where the useful signal is small relative to the bridge excitation and changes at low frequency. Differential input architecture helps preserve the small differential sensor voltage while rejecting shared supply and ground disturbance. The 16-bit conversion resolution and integrated 2.048 V reference provide a repeatable measurement foundation. Engineers should still calculate bridge sensitivity, verify input common-mode range, apply suitable input filtering, and avoid adding excessive source resistance that could disturb the converter's sampling behavior.
おすすめ
Environmental Sensor Acquisition
The MCP3426A4-E/MS can acquire temperature, humidity, gas, and light signals from slow-changing environmental sensors. Its two channels allow two sensor outputs to be measured sequentially, and the 15 samples/s rate is more than adequate for many seconds- or minutes-scale environmental variations. The integrated 2.048 V reference reduces external precision-component count, while differential inputs can help when the sensor is referenced to the same return as the converter. Calibration should account for sensor offset, gain, reference behavior, and the input network placed at the connector or probe.
おすすめ
Laboratory Data Acquisition
For laboratory measurements such as potentiometers, resistive dividers, and low-frequency transducer outputs, the MCP3426A4-E/MS provides a compact 16-bit conversion stage. Its 8-MSOP package keeps the analog section compact, and the two-input architecture supports a reference channel or differential pairing. A 15 samples/s rate suits recorded variables that change slowly, but it is not intended for audio-band or high-speed transient capture. Use shielded sensor wiring, defined grounding, and post-conversion digital filtering to obtain repeatable results.
おすすめ
Battery-Powered Instrumentation
The MCP3426A4-E/MS can serve as the measurement section of a battery-powered instrument because it supports supply voltages from 2.7 V to 5.5 V and is designed for low-speed precision conversion. The operating current and available shutdown behavior must be confirmed in the manufacturer datasheet for the selected mode. Since the converter's conversion rate is 15 samples/s, the host controller can remain in a low-power state between measurements. Use the internal reference when its accuracy is sufficient, and account for the reference's contribution to the overall measurement uncertainty.
おすすめ
Precision Potentiometer Measurement
The MCP3426A4-E/MS is well suited to high-resolution potentiometer and resistive-divider measurements that require more than 8 to 12 bits but occur at human or machine speed. Its 16-bit resolution can expose subtle position or level changes, while the two-channel architecture can support a second reference or complementary measurement. Input impedance and acquisition time are important because very high source resistance can interact with internal sampling circuitry. Follow the datasheet settling requirements, include input filtering where appropriate, and calibrate endpoint offset and linearity over the mechanical range.
おすすめ
おすすめ製品の概要
エンジニアリング参考データ: MCP3426A4-E/MS — 比較、設計ガイダンス、コンプライアンス情報。
選定ガイド
代替品との比較
| パラメータ | この製品 | MCP3426A4T-E/MS | MCP3426A5-E/MS | MCP3426A1T-E/MS |
|---|---|---|---|---|
| Brand | Microchip Technology | Microchip Technology | Microchip Technology | Microchip Technology |
| Package | 8-MSOP | 8-MSOP - same package | 8-MSOP - same package | 8-MSOP - same package |
| Resolution | 16 bit | 16 bit | 16 bit | 16 bit |
| Conversion Architecture | 1-channel delta-sigma ADC | 1-channel delta-sigma ADC | Delta-sigma ADC family | MCP3426 delta-sigma family |
| Special Configuration | MCP3426A4 family code | A4T family code | A5 family code | A1T family code |
主な差別化要因
- Closest identified package and speed match (vs MCP3426A4T-E/MS)
- Two-channel measurement in a compact package (vs MCP3426A1-E/MS)
- Integrated precision reference (vs MCP3426A5-E/MS)
設計ノート
Treat the analog input and reference paths as sensitive short interconnects. Place the input filtering components, reference components, and their grounding returns close to the MCP3426A4-E/MS instead of routing them around the PCB. Keep the digital interface away from the analog input nodes, use a continuous ground reference, and follow the manufacturer pinout and recommended layout before defining the board footprint.
Do not assume that a resistor divider automatically makes any 0–5 V sensor safe for this converter. Check the signal against both the differential input range and the common-mode limits at the 2.7 V to 5.5 V operating supply. A passive attenuator also changes the available resolution, while protection-diode leakage and input bias current can introduce error. Verify the complete input network under minimum and maximum signal conditions.
Source impedance can be as important as signal amplitude for a delta-sigma ADC. Long sensor wiring, high-value divider resistors, and narrow filtering capacitors can prevent the internal sampling network from settling within the selected conversion interval. Use the manufacturer acquisition guidance to determine suitable resistor and capacitor values, or add a low-noise buffer when the sensor cannot meet the required settling behavior.
Decouple analog and digital supplies independently and keep the supply loop areas small. A stable reference and low-impedance power rail are as important as the ADC's nominal resolution because supply disturbance can appear as measurement error. Start with the manufacturer-recommended capacitor values and placement, then validate noise, startup, and reference settling on the completed board rather than relying only on individual component tolerances.
コンプライアンス情報