MCP3426A4-E/MS - 16-Bit Dual-Channel 15 SPS ADC | Microchip
料号: MCP3426A4-E/MS ✓ 量产中MCP3426A4-E/MS 概述
A delta-sigma ADC is an analog-to-digital converter category that uses continuous-time oversampling and digital filtering to deliver high resolution from a low-noise analog front end. The MCP3426 belongs to the broader hierarchy of ADC, data-converter IC, signal-conditioning semiconductor, and analog measurement device. Its differential inputs can reject common-mode disturbance when paired with suitable sensor arrangements, while the integrated reference simplifies calibration and reduces the number of external precision components.
The MCP3426A4 provides up to 16-bit resolution, two analog input channels, and a 15 SPS conversion rate. Its differential input range extends to ±2.048 V when the internal 2.048 V reference is selected. The converter is optimized for low-noise measurements rather than high-speed waveform capture. Separate analog and digital supply connections also allow a mixed-signal board to control analog and digital supply paths independently, provided each supply remains within its specified operating range.
The converter uses a one-channel delta-sigma signal chain with digital filtering to achieve accurate results at low sample rates. This architecture is appropriate for temperature, pressure, strain, potentiometer, and slow process-control signals where resolution and input-noise performance matter more than high conversion bandwidth. The integrated reference and two differential-capable input channels reduce the need for external signal-conditioning hardware in many measurement circuits.
Typical uses include industrial process monitoring, laboratory data acquisition, environmental sensors, bridge-based pressure measurement, and battery-powered instrumentation. The 2.7 V to 5.5 V supply range supports both 3.3 V and 5 V systems. For designs operating from a regulated 5 V rail, the converter can also support the 2.048 V differential range around ground when the input and reference configuration permits it.
Designers should pay close attention to input common-mode voltage, source impedance, filtering, grounding, and decoupling. A high-impedance sensor or resistive divider can require a longer sampling interval than the nominal conversion rate. Place the input and reference components close to the associated pins, maintain the analog and digital return paths separately, and follow the manufacturer datasheet for recommended capacitor values and layout.
This page combines the exact MCP3426A4-E/MS configuration, package information, family alternatives, commercial sourcing guidance, and practical analog-design considerations. It also distinguishes true same-package options from wider ADC choices that may require different boards, interfaces, or external circuitry.
直接替换替代料: MCP3426A4-E/MS ——相同封装,引脚兼容。需要 PCB 改动的不同封装料号已排除。
本系列中的变体
可与以下型号直接替换的同系列型号: MCP3426A4-E/MS (相同外形与封装尺寸) ——差异在于 Differential Input Range, Package, Input Channels, Input Configuration, Maximum Conversion Rate.
MCP3426A4T-E/MS
✅ 直接替换📋 参考替代料(不在目录中)
MCP3426A5-E/MS
✅ 直接替换📋 参考替代料(不在目录中)
MCP3426A1T-E/MS
✅ 直接替换📋 参考替代料(不在目录中)
MCP3426A0-E/MS
✅ 直接替换联系询价
查看数据手册 →MCP3426A1-E/MS
✅ 直接替换 ⚠️ 规格未核验联系询价
查看数据手册 →MCP3426A4-E/MS 最大额定值与电气特性
| ADC Resolution | 16 bit |
| Input Channel Count | 2 channels |
| Conversion Architecture | 1-channel delta-sigma ADC |
| Maximum Conversion Rate | 15 samples/s |
| Input Type | 2 differential-capable analog inputs |
| Internal Reference Voltage | 2.048 V |
| Differential Input Range | ±2.048 V |
| Minimum Supply Voltage | 2.7 V |
| Maximum Supply Voltage | 5.5 V |
| Minimum Operating Temperature | -55 °C |
| Maximum Operating Temperature | 125 °C |
| 封装 | 8-MSOP |
| 引脚数量 | 8 pins |
| 安装类型 | Surface mount |
MCP3426A4-E/MS 8-msop 引脚配置指南
MCP3426A4-E/MS(8-msop 封装)的引脚配置。 该模拟元件具有输入、输出和电源引脚。请参阅制造商数据手册以了解失调调零、补偿和使能引脚配置。适用于信号调理和放大器电路。
暂无详细引脚数据: MCP3426A4-E/MS.
请参阅 数据手册 以查看完整引脚配置。
典型应用
MCP3426A4-E/MS 适用于 6 应用s: Industrial Process Monitoring, Pressure and Strain Measurement, Environmental Sensor Acquisition, Laboratory Data Acquisition, Battery-Powered Instrumentation, Precision Potentiometer Measurement.
Industrial Process Monitoring
The MCP3426A4-E/MS fits slow industrial process signals that require more resolution than a conventional low-cost converter but do not need rapid acquisition. Its 16-bit resolution, two analog channels, and 15 samples/s rate support pressure, flow, level, and temperature monitoring. Differential inputs can reduce common-mode pickup when the sensor and return paths are balanced, while the integrated 2.048 V reference simplifies excitation and measurement calibration. The principal design consideration is ensuring that every signal remains inside the converter's common-mode and input limits throughout the process range.
推荐
Pressure and Strain Measurement
The MCP3426A4-E/MS is appropriate for bridge-based pressure and strain instrumentation where the useful signal is small relative to the bridge excitation and changes at low frequency. Differential input architecture helps preserve the small differential sensor voltage while rejecting shared supply and ground disturbance. The 16-bit conversion resolution and integrated 2.048 V reference provide a repeatable measurement foundation. Engineers should still calculate bridge sensitivity, verify input common-mode range, apply suitable input filtering, and avoid adding excessive source resistance that could disturb the converter's sampling behavior.
推荐
Environmental Sensor Acquisition
The MCP3426A4-E/MS can acquire temperature, humidity, gas, and light signals from slow-changing environmental sensors. Its two channels allow two sensor outputs to be measured sequentially, and the 15 samples/s rate is more than adequate for many seconds- or minutes-scale environmental variations. The integrated 2.048 V reference reduces external precision-component count, while differential inputs can help when the sensor is referenced to the same return as the converter. Calibration should account for sensor offset, gain, reference behavior, and the input network placed at the connector or probe.
推荐
Laboratory Data Acquisition
For laboratory measurements such as potentiometers, resistive dividers, and low-frequency transducer outputs, the MCP3426A4-E/MS provides a compact 16-bit conversion stage. Its 8-MSOP package keeps the analog section compact, and the two-input architecture supports a reference channel or differential pairing. A 15 samples/s rate suits recorded variables that change slowly, but it is not intended for audio-band or high-speed transient capture. Use shielded sensor wiring, defined grounding, and post-conversion digital filtering to obtain repeatable results.
推荐
Battery-Powered Instrumentation
The MCP3426A4-E/MS can serve as the measurement section of a battery-powered instrument because it supports supply voltages from 2.7 V to 5.5 V and is designed for low-speed precision conversion. The operating current and available shutdown behavior must be confirmed in the manufacturer datasheet for the selected mode. Since the converter's conversion rate is 15 samples/s, the host controller can remain in a low-power state between measurements. Use the internal reference when its accuracy is sufficient, and account for the reference's contribution to the overall measurement uncertainty.
推荐
Precision Potentiometer Measurement
The MCP3426A4-E/MS is well suited to high-resolution potentiometer and resistive-divider measurements that require more than 8 to 12 bits but occur at human or machine speed. Its 16-bit resolution can expose subtle position or level changes, while the two-channel architecture can support a second reference or complementary measurement. Input impedance and acquisition time are important because very high source resistance can interact with internal sampling circuitry. Follow the datasheet settling requirements, include input filtering where appropriate, and calibrate endpoint offset and linearity over the mechanical range.
推荐
推荐产品汇总
工程参考数据: MCP3426A4-E/MS ——对比、设计指导和合规信息。
选型指南
与替代料对比
| 参数 | 本产品 | MCP3426A4T-E/MS | MCP3426A5-E/MS | MCP3426A1T-E/MS |
|---|---|---|---|---|
| Brand | Microchip Technology | Microchip Technology | Microchip Technology | Microchip Technology |
| Package | 8-MSOP | 8-MSOP - same package | 8-MSOP - same package | 8-MSOP - same package |
| Resolution | 16 bit | 16 bit | 16 bit | 16 bit |
| Conversion Architecture | 1-channel delta-sigma ADC | 1-channel delta-sigma ADC | Delta-sigma ADC family | MCP3426 delta-sigma family |
| Special Configuration | MCP3426A4 family code | A4T family code | A5 family code | A1T family code |
关键差异点
- Closest identified package and speed match (对比 MCP3426A4T-E/MS)
- Two-channel measurement in a compact package (对比 MCP3426A1-E/MS)
- Integrated precision reference (对比 MCP3426A5-E/MS)
设计说明
Treat the analog input and reference paths as sensitive short interconnects. Place the input filtering components, reference components, and their grounding returns close to the MCP3426A4-E/MS instead of routing them around the PCB. Keep the digital interface away from the analog input nodes, use a continuous ground reference, and follow the manufacturer pinout and recommended layout before defining the board footprint.
Do not assume that a resistor divider automatically makes any 0–5 V sensor safe for this converter. Check the signal against both the differential input range and the common-mode limits at the 2.7 V to 5.5 V operating supply. A passive attenuator also changes the available resolution, while protection-diode leakage and input bias current can introduce error. Verify the complete input network under minimum and maximum signal conditions.
Source impedance can be as important as signal amplitude for a delta-sigma ADC. Long sensor wiring, high-value divider resistors, and narrow filtering capacitors can prevent the internal sampling network from settling within the selected conversion interval. Use the manufacturer acquisition guidance to determine suitable resistor and capacitor values, or add a low-noise buffer when the sensor cannot meet the required settling behavior.
Decouple analog and digital supplies independently and keep the supply loop areas small. A stable reference and low-impedance power rail are as important as the ADC's nominal resolution because supply disturbance can appear as measurement error. Start with the manufacturer-recommended capacitor values and placement, then validate noise, startup, and reference settling on the completed board rather than relying only on individual component tolerances.
合规信息
Compliance status was not established from the product summary. Confirm the exact MCP3426A4-E/MS ordering information and declarations in the Microchip product documentation before using the part in a regulated design.