Texas Instruments

TCA8424RHAR - 24-Bit I2C Keypad Scanner | Texas Instruments

部品番号: TCA8424RHAR ✗ 生産終了
1.65 V to 3.6 V Vdss 40-pin VQFN Package 1 MHz Speed
MOQ: 1 |

TCA8424RHAR 概要

The Texas Instruments TCA8424RHAR is a low-voltage 8×16 keypad scanner with a 24-bit key-state register, a 1.65 V to 3.6 V supply range, and an I2C/SMBus-compatible interface rated for operation up to 1 MHz. The device is packaged in a 40-pin VQFN measuring 6 mm × 6 mm and supports as many as 128 keys. An interrupt output allows the host processor to be notified when the scanned key matrix changes, reducing unnecessary polling and helping conserve power in portable and embedded systems.

A keypad scanner is an interface integrated circuit that converts the electrical state of a matrix of switches into a compact digital status value. In the system hierarchy, it belongs to the interface-controller family within integrated circuits, alongside I2C and SMBus peripherals, GPIO expanders, and human-interface-device controllers. The TCA8424RHAR is designed to sit between a mechanical keypad matrix and an embedded host such as a microcontroller, leaving the host to interpret recognized key events and perform application-specific actions.

The principal feature is support for an 8×16 matrix, providing 128 scanning positions in a compact physical footprint. Its 24-bit key-state register provides a defined digital representation of the matrix, while the interrupt signal supports event-driven host communication. Operation from 1.65 V to 3.6 V makes the scanner suitable for low-voltage embedded systems, and the 1 MHz interface capability allows it to operate on a faster shared serial bus when host timing and bus capacitance permit.

The device combines matrix scanning with an I2C/SMBus-compliant host interface and HID-oriented keyboard-scanner functionality. These characteristics make it useful where a conventional matrix requires many host GPIO pins or where a dedicated serial keypad controller simplifies firmware. The scanner limits the host interface to the serial bus and interrupt line rather than requiring one GPIO input for every key position. Configuration and status reporting are handled through the serial interface, while the interrupt output indicates that the matrix state requires attention.

Typical applications include consumer keypads, security-access panels, industrial control membranes, portable instruments, and compact human-interface panels. A product with 128 possible switch positions can use the full scanner capacity, while systems with fewer switches can leave unused matrix positions unconnected according to the manufacturer's implementation guidance. The device can also complement a touchscreen controller by providing physical-key input alongside touch input when a product requires both interaction methods.

Layout planning should account for the 40-pin VQFN footprint, exposed thermal pad, decoupling requirements, and signal integrity of the I2C bus. Place the input and interface bypass capacitors close to their corresponding pins, route the interrupt trace away from high-current switching nodes, and confirm pull-up values against the bus voltage, capacitance, and operating speed. Because the 1 MHz rating is a maximum interface capability rather than a requirement for every design, use a conservative bus rate when signal-integrity margins are limited.

This product page combines the manufacturer’s device capabilities with package, sourcing, interface, and design information in one engineering-focused reference. It also identifies the limits of the available substitution evidence: no same-package, pin-to-pin replacement is asserted unless its electrical characteristics and land pattern have been independently confirmed.

ドロップイン代替品: TCA8424RHAR — 同一パッケージでピン互換。PCBの作り直しが必要な異なるパッケージの部品は除外されています。

この製品に利用可能なドロップイン代替品はありません。

代替品をリクエスト

TCA8424RHAR 仕様

Device Type 8×16 keyboard scanner
Key Matrix Capacity 128 keys
Key-State Register Width 24 bits
動作電源電圧 1.65 V to 3.6 V
Maximum I2C/SMBus Interface Frequency 1 MHz
Host Interface I2C/SMBus-compatible
Interrupt Output Present
Package Type 40-pin VQFN
Package Dimensions 6 mm × 6 mm
実装タイプ Surface mount

TCA8424RHAR 6 mm × 6 mm ピン配置ガイド

TCA8424RHAR (6 mm × 6 mm パッケージ) のピン配置。 ピン番号、機能、接続図はメーカーのデータシートで定義されています。正確なフットプリントとはんだ付けのガイドラインについては、データシートを参照してください。

TCA8424RHAR の 6 mm × 6 mm パッケージピン配置図

詳細なピン配置データはありません: TCA8424RHAR.

詳細は データシート をご参照ください。

主な用途

TCA8424RHAR の用途: 6 件s: Consumer Security Keypad, Industrial Control Membrane, Portable Test Instrument, Human-Interface Control Panel, Appliance Control Panel, Portable Medical or Diagnostic Panel.

🔐

Consumer Security Keypad

The TCA8424RHAR fits a numeric access keypad that requires many keys without consuming a separate host pin for every switch position. Its 8×16 architecture supports as many as 128 matrix positions, while the 24-bit key-state register provides a compact serialized representation of the keypad. The 1.65 V to 3.6 V operating range also fits many low-voltage embedded access-control systems. Place the controller beside the keypad connector, use the interrupt output to wake the host after a key event, and keep the I2C route away from motor and relay switching nodes. Firmware should debounce according to the switch characteristics and the scanner behavior described by Texas Instruments.

🏭

Industrial Control Membrane

A membrane keypad in an industrial controller can use the TCA8424RHAR to monitor a large switch field through a compact serial interface. Supporting 128 possible key positions allows the panel to combine function keys, navigation controls, and numeric entry without assigning 128 microcontroller GPIO inputs. The I2C/SMBus-compatible interface operates up to 1 MHz, while the interrupt output supports event-driven host processing and can reduce unnecessary polling in a control panel with infrequent user activity. Designers should verify voltage levels, incorporate bus pull-ups appropriate to the operating frequency, and provide local filtering near long or electrically noisy membrane traces.

🔧

Portable Test Instrument

The TCA8424RHAR is appropriate for a compact measurement instrument whose front panel contains an 8×16 key matrix. The dedicated scanner keeps matrix wiring organized and presents key state to the host over I2C/SMBus, leaving the controller available for measurement and display functions. The 1.65 V to 3.6 V supply range supports low-voltage portable equipment, and the interrupt signal allows the host to suspend active measurement tasks until a control is pressed. For battery-operated instruments, validate standby behavior and leakage against the complete power budget. The 40-pin VQFN also requires careful thermal-pad and trace-layout planning within a densely populated handheld enclosure.

🎛️

Human-Interface Control Panel

A human-interface control panel can use the TCA8424RHAR to consolidate physical navigation and function keys into an 8×16 matrix. This is useful when the product needs more than a handful of buttons but should avoid a large GPIO footprint. The interrupt output provides a direct signal for waking the application processor, while the 24-bit register supplies the scanned state over the serial bus. In mixed display-and-keypad products, the scanner can operate alongside a display interface and touch controller, provided the firmware assigns independent host resources. Firmware should establish a stable key-event model and verify debounce timing under both fast presses and simultaneous key combinations.

🔌

Appliance Control Panel

The TCA8424RHAR can serve as the input controller for an appliance panel containing a dense membrane keypad. Its 128-key matrix capability allows designers to combine numeric entry, mode selection, and dedicated function keys behind one serial peripheral. The 1.65 V to 3.6 V operating range accommodates low-voltage control electronics, while the interrupt capability reduces the need for continuous host scanning. The interface should be isolated from high-current motor-control and switching-supply regions, with the I2C pull-ups placed close to the bus and the keypad traces routed away from noisy power stages. Production testing should include bounce, stuck-key, and intermittent-connector fault coverage.

💊

Portable Medical or Diagnostic Panel

A compact diagnostic instrument can use the TCA8424RHAR for a physical keypad that complements display-based operation. The dedicated scanner supports an 8×16 matrix, giving designers up to 128 switch positions without requiring equivalent GPIO capacity on the main controller. The interrupt output supports prompt host response, and the low 1.65 V to 3.6 V operating range is compatible with embedded power systems. Because medical or diagnostic equipment may combine sensitive analog measurement circuits with touch displays, keypad and I2C routing should remain away from high-impedance inputs. Confirm electromagnetic-immunity requirements, connector debounce behavior, and the risk-control process before using this obsolete catalog part in a new regulated design.

What is the Texas Instruments TCA8424RHAR?
The Texas Instruments TCA8424RHAR is a low-voltage 8×16 keyboard scanner with an I2C/SMBus-compatible interface, a 24-bit key-state register, and support for up to 128 keys. According to the Texas Instruments product page, the device operates from 1.65 V to 3.6 V, supports interface speeds up to 1 MHz, and provides an interrupt output. It is housed in a 40-pin VQFN package measuring 6 mm × 6 mm.
What is the operating voltage range of TCA8424RHAR?
The TCA8424RHAR operates from 1.65 V to 3.6 V according to the Texas Instruments product page. This range supports low-voltage embedded systems and portable products. The serial interface pull-ups and any external host circuitry should be referenced to the same system voltage. For designs using the full 1 MHz interface capability, verify signal-integrity and bus-capacitance requirements rather than treating 1 MHz as a mandatory operating speed.
How many keys can the TCA8424RHAR scan?
The TCA8424RHAR can scan up to 128 keys in an 8×16 matrix. According to the Texas Instruments product information, the scanner presents matrix state through its 24-bit key-state register and communicates with the host through an I2C/SMBus-compatible interface. This capacity allows a compact keypad implementation to replace as many as 128 dedicated host GPIO inputs while retaining a defined event-driven scan function.
Does the TCA8424RHAR support I2C and SMBus?
Yes, the TCA8424RHAR uses an I2C/SMBus-compatible host interface with operation up to 1 MHz. According to the Texas Instruments product page, this serial interface allows the keypad scanner to share a bus with other compatible peripherals. The host can read the 24-bit key-state register and configure scanner behavior, while the interrupt output provides an event-driven indication that the matrix state has changed.
What is the interrupt output used for on the TCA8424RHAR?
The TCA8424RHAR interrupt output notifies the host processor when the scanned key matrix changes, allowing event-driven operation instead of continuous polling. The Texas Instruments product page identifies the interrupt function as a principal feature of the device. This can reduce host processing and improve power efficiency in systems where keypad activity is infrequent, although the exact interrupt behavior and configuration should be confirmed in the manufacturer datasheet.
Where can I find the TCA8424RHAR datasheet?
The authoritative product and support page for the TCA8424RHAR is available at the Texas Instruments TCA8424 product URL, while the device is also listed under the 40-pin VQFN interface category on DigiKey. The manufacturer page provides the official product information and downloadable technical documentation. Use the pin-description and application information from that document when assigning tracks, selecting pull-ups, and determining how unused matrix rows or columns should be handled.
Where is the TCA8424RHAR pinout located?
The TCA8424RHAR pinout is defined by the 40-pin VQFN package data and the pin-description table in the Texas Instruments TCA8424 documentation. The verified package information identifies a 6 mm × 6 mm VQFN with 40 pins. Because individual terminal names and their complete numbering are not reproduced on this page, use the manufacturer diagram directly before assigning PCB nets or checking a replacement for pin-to-pin compatibility.
Where can I buy TCA8424RHAR and check current availability?
The current commercial status of the TCA8424RHAR can be requested through the Request a Quote form on this page. The form is the appropriate route for obtaining a responsive quotation, current availability, minimum order quantity, and lead-time confirmation for this obsolete interface IC. A component can remain available for limited supply or aftermarket procurement while its manufacturer lifecycle status is discontinued.
What is the price of TCA8424RHAR?
The current commercial terms for the TCA8424RHAR are obtained through the Request a Quote form on this page. The structured pricing area on the product page reflects current sourcing conditions and may include different quantities or supply constraints. Because the TCA8424RHAR is an obsolete catalog part, request the exact suffix TCA8424RHAR when seeking a quotation to avoid confusion with other TCA8424 package or ordering variants.
What is the lead time for TCA8424RHAR?
The lead time for TCA8424RHAR should be confirmed through the Request a Quote form on this page. Lead time depends on available factory inventory, authorized-channel allocation, and the requested quantity, all of which can change for an obsolete interface IC. Providing the required quantity and target shipment date in the request allows the sourcing team to return a current commitment rather than an outdated availability statement.
Is TCA8424RHAR in stock?
TCA8424RHAR stock should be checked through the Request a Quote form on this page. The manufacturer product information identifies the device as discontinued, so inventory may be limited and suitable for planned maintenance rather than new long-term production designs. When requesting availability, specify the required quantity, date code preference, traceability requirement, and whether a factory-sealed package is mandatory.
What is the best drop-in replacement for TCA8424RHAR?
No drop-in replacement is established here without verified pin-level and electrical cross-reference data. The available substitute search identifies the TCA8424RHAR as discontinued but does not provide a candidate with a confirmed 40-pin VQFN land pattern, identical pin assignments, and comparable operating characteristics. Do not treat a keyboard scanner with a different package or matrix arrangement as a direct replacement; use the manufacturer cross-reference tools and verify the candidate datasheet.
Can a different keyboard scanner replace TCA8424RHAR?
A different keyboard scanner can replace the TCA8424RHAR only after its package, pin assignments, supply range, key-register format, interrupt behavior, and interface protocol have been checked. The Texas Instruments device scans an 8×16 matrix and supports up to 128 keys at a 1.65 V to 3.6 V supply range. A replacement with a different package or matrix architecture may require a PCB redesign and firmware changes, so it is not a drop-in substitution.
When should I choose TCA8424RHAR instead of a GPIO-based keypad scanner?
Choose the TCA8424RHAR when a compact 8×16 matrix, compact 40-pin VQFN construction, serial host connectivity, and event-driven interrupt handling are more valuable than minimizing the absolute number of external components. A direct microcontroller GPIO scan is simpler for very small matrices, but it consumes many processor pins as the key count increases. The TCA8424RHAR moves matrix scanning into a dedicated interface IC while exposing state through I2C/SMBus.
Is TCA8424RHAR suitable for a 128-key product?
Yes, the TCA8424RHAR is suitable for a design requiring the full 8×16 matrix because it supports up to 128 keys and provides a 24-bit key-state register. The Texas Instruments product page identifies a 1.65 V to 3.6 V operating range and a host interface capable of 1 MHz. Validate switch bounce behavior, interrupt handling, bus loading, and the manufacturer’s guidance for unused matrix positions before releasing the production design.

エンジニアリング参考データ: TCA8424RHAR — 比較、設計ガイダンス、コンプライアンス情報。

選定ガイド

Choose the TCA8424RHAR when the design needs an 8×16 matrix, up to 128 physical keys, a 24-bit key-state register, and an I2C/SMBus host interface in a 40-pin VQFN package. It is particularly useful when conserving microcontroller GPIO pins or implementing event-driven keypad operation matters more than using a newer catalog device. Consider a GPIO-based matrix for small key counts, simpler firmware, or new designs that can use a current active part. Do not select a differently packaged scanner as a drop-in replacement: verify every terminal assignment, the exposed-pad connection, key-register behavior, interrupt polarity, supply range, and interface timing. For new production programs, confirm the Texas Instruments lifecycle status and consider an active successor before committing the PCB.

代替品との比較

パラメータ この製品
Device Type 8×16 keyboard scanner
Brand Texas Instruments
Package 40-pin VQFN, 6 mm × 6 mm
Key Capacity 128 keys
Key-State Register 24 bits
Operating Supply Voltage 1.65 V to 3.6 V
Maximum Interface Frequency 1 MHz
Host Interface I2C/SMBus-compatible
Interrupt Output Present

主な差別化要因

  • Large matrix capacity in a compact interface IC (vs Direct microcontroller GPIO matrix scanning)
  • Event-driven host integration (vs Periodic software key polling)
  • Compact serial interface footprint (vs Discrete GPIO matrix implementation)

設計ノート

Treat the TCA8424RHAR as a 40-pin VQFN rather than a generic QFN. Follow the Texas Instruments land pattern and exposed-pad recommendations for the 6 mm × 6 mm package, including the required via arrangement and solderable thermal area. Place input, interface, and reference decoupling capacitors close to their associated pins to minimize loop area. Confirm the final footprint against the package drawing before releasing PCB artwork.

The interface can operate at up to 1 MHz, but the usable bus rate depends on bus capacitance, pull-up strength, clock stretching, and trace topology. Calculate the pull-up network for the actual voltage and load, keep the I2C route short, and provide a continuous ground reference beneath the pair. Reduce the switching rate or add series damping if edge overshoot or ringing appears on long PCB routes.

Do not interpret the 1 MHz rating as proof that every bus can run at 1 MHz. Verify the host controller, pull-ups, capacitance, and peripheral timing, then select a lower rate when system margin is limited. Also account for switch bounce when interpreting the 24-bit key-state register, and use the interrupt output with a host debounce strategy rather than assuming every electrical transition represents a deliberate user action.

Keep the keypad matrix and I2C traces away from switching regulators, relay drivers, motor outputs, and high-current return paths. A continuous ground plane beneath the controller can reduce coupling, but avoid routing matrix signals directly above a noisy power stage. Where the keypad cable is long or the environment contains an inverter or motor, use the shortest practical connection, provide a solid reference plane, and validate the complete panel for susceptibility and false key events.

コンプライアンス情報

RoHS
Unknown
REACH
Unknown
AEC-Q100
Unknown
鉛フリー
Unknown
ハロゲンフリー
Unknown
紛争鉱物
Unknown

The Texas Instruments product page and package listings do not provide explicit compliance declarations for this MPN. The RHAR ordering suffix identifies the packaged device but does not independently establish RoHS, REACH, AEC-Q100, halogen-free, or conflict-minerals status.

関連検索

TCA8424RHAR datasheet TCA8424RHAR pinout TCA8424RHAR datasheet pdf TCA8424RHAR specifications Texas Instruments TCA8424RHAR TCA8424RHAR equivalent TCA8424RHAR replacement TCA8424RHAR cross reference TCA8424RHAR price TCA8424RHAR stock 40-VQFN keypad scanner 8x16 I2C keypad scanner TCA8424 keyboard controller application TCA8424RHAR schematic TCA8424RHAR footprint

関連部品&用語

Texas Instruments TCA8424 TCA8424RHAR TCA8418RTWR keyboard scanner keypad scanner interface IC integrated circuit semiconductor I2C SMBus HID over I2C 8x16 keypad matrix 24-bit key-state register 128-key support interrupt output 1 MHz I2C 1.65 V to 3.6 V 40-pin VQFN VQFN package family surface-mount package RoHS REACH AEC-Q100
クイック見積RFQ
詳細をすべてご記入ください — 営業チームが24時間以内にご返信いたします
部品番号 メーカー パッケージ QTY 目標価格 小計
✓
見積を送信しました!

24時間以内にメールでご返信いたします

1
RFQ送信済み
2
見積受領
3
注文済み
4
お支払い
5
発送済み
6
配達済み
RFQの詳細を表示