AD624CDZ - 25 MHz Precision Instrumentation Amplifier | Analog Devices
부품 번호: AD624CDZ ✓ 활성AD624CDZ 개요
An instrumentation amplifier is a specialized amplifier category optimized for differential signals originating from sensors such as load cells, strain gauges, and pressure transducers. Its internal three-amplifier architecture provides high input impedance, common-mode rejection, and precise gain setting without requiring matched external resistors. Within the signal-chain hierarchy, an instrumentation amplifier belongs to the amplifier family and ultimately to the broader category of analog signal-conditioning integrated circuits.
The AD624CDZ combines a 25 MHz gain-bandwidth product with internal trim networks for gains of 1, 100, 200, 500, and 1000. The manufacturer identifies the device as a high-precision, low-noise instrumentation amplifier with an outstanding combination of noise performance, gain accuracy, low gain temperature coefficient, and linearity. These characteristics support high-resolution data-acquisition systems in which the transducer output is small and the useful signal occupies only a small portion of the amplifier's full-scale capability.
Fast analog performance makes the AD624 useful beyond slow process-control loops. The 5 V/us slew rate allows large input steps to be followed without excessive settling delay, and the 15 us settling specification supports high-speed measurement systems. Because the AD624 uses internal trim resistors, its factory-calibrated gain behavior avoids the resistor-matching errors that normally appear in discrete instrumentation-amplifier implementations. Users can still select intermediate gains with an external resistor placed across the gain-set terminals.
Typical applications include load-cell and strain-gauge measurement bridges, industrial pressure transducers, high-resolution data acquisition, medical instrumentation, and instrumentation-amplifier input stages for precision converters. The 16-lead ceramic DIP package supports conventional through-hole assembly and is appropriate where long service life and temperature stability are more important than surface-mount area reduction.
When laying out the circuit, place the AD624 close to the sensor bridge and route the differential sensor inputs as a short, symmetric pair to minimize pickup from switching nodes. Avoid long parallel runs beneath high-current or high-voltage traces, and use a shield or guard strategy when the transducer leads are long. Verify the input common-mode range, supply voltage, output swing, and gain-set resistor value against the manufacturer datasheet before finalizing the circuit.
This page combines manufacturer performance data, package information, application engineering guidance, and a structured comparison of compatible AD624 family members. It is intended to help engineers select a suitable gain setting, plan the layout, and evaluate replacement options without relying on a distributor summary alone.
드롭인 대체품: AD624CDZ — 동일 패키지, 핀 호환. PCB 재작업이 필요한 다른 패키지 부품은 제외됩니다.
이 시리즈의 변형
다음과 드롭인 호환되는 동일 시리즈 모델: AD624CDZ (동일 폼 팩터 및 풋프린트) — 차이점: Package, Input Offset Voltage, Mounting Type, Settling Time, Slew Rate.
AD624CZ
✅ 드롭인 ⚠️ 사양 미검증📋 참조 대체품 (카탈로그에 없음)
AD624BDZ
✅ 드롭인가격 문의
데이터시트 보기 →AD624ARZ
✅ 드롭인 ⚠️ 사양 미검증📋 참조 대체품 (카탈로그에 없음)
AD624SDZ
✅ 드롭인📋 참조 대체품 (카탈로그에 없음)
AD624CD
✅ 드롭인가격 문의
데이터시트 보기 →AD624CDZ 최대 정격 & 전기적 특성
| Amplifier Type | Precision instrumentation amplifier |
| Number of Circuits | 1 circuit |
| Gain-Bandwidth Product | 25 MHz |
| Slew Rate | 5 V/us |
| Settling Time | 15 us |
| Factory-Trimmed Gains | 1, 100, 200, 500, and 1000 |
| Internal Gain-Set Resistor | Present; external resistor supported for other gains |
| Input Bias Current | 15 nA |
| Offset Voltage | 25 uV |
| Noise Bandwidth | 1 MHz |
| 패키지 | 16-CDIP (0.300 in, 7.62 mm) |
| 실장 유형 | Through-hole ceramic DIP |
| 핀 수 | 16 pins |
| RoHS 상태 | Compliant |
AD624CDZ 16-cdip (0.300 in, 7.62 mm) 핀 구성 가이드
AD624CDZ(16-cdip (0.300 in, 7.62 mm) 패키지)의 핀 구성입니다. 이 아날로그 부품에는 입력, 출력, 전원 공급 핀이 있습니다. 오프셋 널, 보상, 인에이블 핀 구성은 제조사 데이터시트를 참조하십시오. 신호 컨디셔닝 및 증폭기 회로에 이상적입니다.
다음에 대한 상세 핀아웃 데이터 없음: AD624CDZ.
다음을 참조하십시오: 데이터시트 전체 핀 구성은 다음을 참조하십시오.
일반적인 애플리케이션
AD624CDZ 적합 용도: 6 애플리케이션s: Load-Cell Weighing Systems, Strain-Gage Transducer Front Ends, Industrial Pressure Transducer Measurement, High-Resolution Data Acquisition, Medical Instrumentation Signal Conditioning, Laboratory Sensor Instrumentation.
Load-Cell Weighing Systems
The AD624CDZ fits the input stage of a precision weighing system because its differential architecture can amplify the small bridge imbalance produced by a load cell. Its factory-trimmed gains of 1, 100, 200, 500, and 1000 cover common transducer sensitivities while limiting gain-setting errors. The 25 MHz gain-bandwidth product and 15 us settling time allow rapid acquisition, although practical weighing systems are usually limited by mechanical resonance and sensor noise rather than amplifier speed. Place the amplifier close to the bridge, keep input traces paired and away from motor and switching circuits, and confirm that the bridge excitation voltage remains within the amplifier's input common-mode range.
추천
Strain-Gage Transducer Front Ends
The AD624CDZ is well suited to strain-gage bridges because it combines low input bias current, precise internal gain settings, and high linearity for extracting small resistance changes from a differential sensor output. A gain of 100 or 500 can amplify a millivolt-level bridge signal while retaining useful bandwidth within the AD624's 25 MHz gain-bandwidth product. Use a regulated bridge excitation source and route the two bridge returns as a tightly coupled differential pair. The design should also include sensor-lead protection and shielding when the gauge is physically separated from the amplifier.
추천
Industrial Pressure Transducer Measurement
A resistive pressure bridge feeding the AD624CDZ benefits from the amplifier's high input impedance and internal gain trim networks. The 1, 100, 200, 500, and 1000 gain options allow the signal chain to be scaled without closely matched external resistors, improving consistency across production units. The 5 V/us slew rate supports recovery from sensor or input-connection transients, but the output must remain within the device's specified swing. Apply input clamping for long external sensor cables and place filtering close to the AD624 so that common-mode transients do not reach the input terminals.
추천
High-Resolution Data Acquisition
The AD624CDZ can serve as the analog front end of a high-resolution acquisition channel when the source produces a low-level differential voltage. Its 25 MHz gain-bandwidth product and 15 us settling time provide ample margin for sampling systems operating below the amplifier's small-signal bandwidth limit. The instrumentation-amplifier configuration simplifies the input stage by providing high impedance and accurate gain in one package. For a complete acquisition design, select an ADC with an input range matched to the AD624 output, keep the analog trace short between amplifier and converter, and evaluate settling against the required sampling interval.
추천
Medical Instrumentation Signal Conditioning
The AD624CDZ can amplify differential bioelectrical or resistive-sensor signals when the design requires a precise, high-impedance input and a selectable factory-trimmed gain. Gain settings of 1, 100, 200, 500, and 1000 provide useful scaling for millivolt-level sources, while the 15 nA input bias current helps limit loading of high-source-impedance sensors. Because the AD624CDZ is a general-purpose amplifier rather than a medical-certified component, compliance must be established at the finished-system level. Use patient-protection networks, isolation requirements, and electromagnetic-compliance measures appropriate to the intended equipment.
추천
Laboratory Sensor Instrumentation
The AD624CDZ is appropriate for laboratory measurement systems that combine interchangeable sensors with accurate gain settings. The internal trimmed-resistor options reduce calibration drift caused by external resistor mismatch, and the 1 V to 1000 V gain selections cover both large and small sensor outputs. Its 25 MHz bandwidth also makes it useful in pulsed or dynamic experiments where the measured signal must settle quickly. Configure the gain for the smallest value that keeps the output within the converter range, and use a warm-up period when high-resolution measurements depend on temperature stability.
추천
추천 제품 요약
엔지니어링 참조 데이터: AD624CDZ — 비교, 설계 지침 및 규정 준수 정보.
선택 가이드
대체품과의 비교
| 파라미터 | 이 제품 | AD624CZ | AD624BDZ | AD624ARZ | AD624SDZ | AD624CD |
|---|---|---|---|---|---|---|
| Package | 16-CDIP (0.300 in, 7.62 mm) | 16-CDIP (0.300 in, 7.62 mm) - same footprint | 16-CDIP (0.300 in, 7.62 mm) - same footprint | 16-CDIP (0.300 in, 7.62 mm) - same footprint | 16-CDIP (0.300 in, 7.62 mm) - same footprint | 16-CDIP (0.300 in, 7.62 mm) - same footprint |
| Brand | Analog Devices | Analog Devices | Analog Devices | Analog Devices | Analog Devices | Analog Devices |
| Amplifier Type | Precision instrumentation amplifier | Precision instrumentation amplifier | Precision instrumentation amplifier | Precision instrumentation amplifier | Precision instrumentation amplifier | Precision instrumentation amplifier |
| Number of Circuits | 1 circuit | 1 circuit | 1 circuit | 1 circuit | 1 circuit | 1 circuit |
| Gain-Bandwidth Product | 25 MHz | 25 MHz | 25 MHz | 25 MHz | 25 MHz | 25 MHz |
| Slew Rate | 5 V/us | 5 V/us | 5 V/us | 5 V/us | 5 V/us | 5 V/us |
| Factory-Trimmed Gains | 1, 100, 200, 500, and 1000 | 1, 100, 200, 500, and 1000 | 1, 100, 200, 500, and 1000 | 1, 100, 200, 500, and 1000 | 1, 100, 200, 500, and 1000 | 1, 100, 200, 500, and 1000 |
| Settling Time | 15 us | 15 us | 15 us | 15 us | 15 us | 15 us |
주요 차별점
- Factory-calibrated high-gain options eliminate external resistor matching (vs AD624BDZ)
- High-speed performance for dynamic sensor signals (vs AD624CZ)
- Single-package differential conditioning (vs AD624ARZ)
설계 노트
Route the two sensor inputs as a short, symmetric differential pair and connect the sensor-side return directly to the amplifier input reference. Keep the AD624 close to the transducer or bridge so that the high-impedance input node is not exposed to long traces that can pickup switching noise. Avoid placing the input pair beneath motor, relay, clock, or high-current power routing. For cables longer than a few centimeters, use twisted sensor wiring and evaluate the input common-mode range before adding protection components.
Select the lowest gain that keeps the expected signal within the AD624 output range. Each decade of gain reduces closed-loop bandwidth in proportion to the 25 MHz gain-bandwidth product, so the 15 us settling specification should be checked against the system's acquisition interval. Decouple the supply pins at the device and preserve a short return path to the circuit reference. If the gain-set terminals are exposed on the board, keep them clean and away from high-voltage switching nodes because the internal resistor provides the precision gain path.
Do not treat every AD624 suffix as electrically identical. The AD624CDZ ordering code identifies a particular package and device grade, while related AD624 variants may use a different package material, temperature grade, or accuracy grade. Before substitution, compare the manufacturer ordering table for pinout, supply voltage, common-mode range, gain accuracy, and temperature rating. Also verify the external gain resistor value against the AD624 gain equation; an incorrect resistor can place the circuit far from the intended gain and reduce usable headroom.
규정 준수 정보
RoHS compliance is indicated in the LCSC product listing. No AEC-Q100 qualification is indicated for this general-purpose instrumentation amplifier.