MAX3232EEUP+G1Z - 1Mbps RS-232 Transceiver | Analog Devices
부품 번호: MAX3232EEUP+G1Z ✓ 활성MAX3232EEUP+G1Z 개요
An RS-232 transceiver is an interface IC that bridges the logic-voltage domain of a digital system and the bipolar signal domain used by RS-232 equipment. It combines line drivers, receivers, charge-pump support circuitry, and ESD protection into one device. The MAX3232 belongs to the broader interface IC hierarchy, where it functions as a physical-layer communications component between embedded controllers and an external RS-232 port.
The device provides true RS-232 output levels rather than limited-voltage RS-232 signaling. Its ±15 kV ESD protection helps protect the transceiver pins when a cable is connected or disconnected. Operation from 3.0 V to 5.5 V allows use in both 3.3 V and 5 V systems, while the maximum data rate of 1 Mbps supports communication rates substantially above common legacy serial-port operating speeds. The low-power design is specified for supply current down to 10 nA under applicable low-power conditions.
The MAX3232 family uses integrated charge-pump circuitry to generate the positive and negative voltage rails needed by true RS-232 drivers. Four external capacitors support this operation, while the IC handles signal conditioning and level translation. Its two-driver, two-receiver arrangement suits point-to-point links in which each endpoint can transmit and receive. Because the +G1Z ordering code identifies a specific package and production configuration, engineers should verify the ordering information, tape orientation, and lead-free status before releasing a production order.
Typical uses include programmable-logic-controller serial links, industrial equipment interfaces, test and measurement instruments, barcode readers, security equipment, and embedded control systems. A controller can connect its logic-level UART pins to the MAX3232EEUP+G1Z and communicate through a standard DE-9 connector. Cable length, baud rate, grounding, termination, and connector shield design remain system-level considerations even when the IC supports rates up to 1 Mbps.
Place the charge-pump capacitors close to their associated pins and route the RS-232 traces away from sensitive analog or high-speed digital circuits. Provide a stable ground reference between the two connected systems, and use appropriate transient protection for cables exposed to industrial or outdoor environments. This page combines interface-family positioning, pin-compatible alternatives, and application-oriented design guidance to support component selection and board planning.
드롭인 대체품: MAX3232EEUP+G1Z — 동일 패키지, 핀 호환. PCB 재작업이 필요한 다른 패키지 부품은 제외됩니다.
이 시리즈의 변형
다음과 드롭인 호환되는 동일 시리즈 모델: MAX3232EEUP+G1Z (동일 폼 팩터 및 풋프린트) — 차이점: Package, Supply Voltage Range, ESD Protection, Maximum Data Rate.
MAX3232EEUP+
✅ 드롭인가격 문의
데이터시트 보기 →MAX3232EEAE
✅ 드롭인 ⚠️ 사양 미검증📋 참조 대체품 (카탈로그에 없음)
MAX3232EETT
✅ 드롭인 ⚠️ 사양 미검증📋 참조 대체품 (카탈로그에 없음)
MAX3232ESA
✅ 드롭인 ⚠️ 사양 미검증📋 참조 대체품 (카탈로그에 없음)
MAX3232ESE+TG035
✅ 드롭인 ⚠️ 사양 미검증가격 문의
데이터시트 보기 →MAX3232EEUP+G1Z 사양
| Product Type | RS-232 transceiver |
| Number of Drivers | 2 |
| Number of Receivers | 2 |
| Interface Standard | True RS-232 |
| Supply Voltage Range | 3.0 V to 5.5 V |
| Maximum Data Rate | 1 Mbps |
| ESD Protection | ±15 kV |
| Low-Power Supply Current | Down to 10 nA |
| 패키지 | 20-TSSOP, 0.173 inch (4.40 mm) width |
| 실장 유형 | Surface mount |
MAX3232EEUP+G1Z 20-tssop, 0.173 inch (4.40 mm) width 핀 구성 가이드
MAX3232EEUP+G1Z(20-tssop, 0.173 inch (4.40 mm) width 패키지)의 핀 구성입니다. 핀 번호, 기능, 연결 다이어그램은 제조사 데이터시트에 정의되어 있습니다. 정확한 풋프린트와 솔더링 지침은 해당 문서를 참조하십시오.
다음에 대한 상세 핀아웃 데이터 없음: MAX3232EEUP+G1Z.
다음을 참조하십시오: 데이터시트 전체 핀 구성은 다음을 참조하십시오.
일반적인 애플리케이션
MAX3232EEUP+G1Z 적합 용도: 6 애플리케이션s: Industrial PLC Serial Communication, Data Acquisition and Test Equipment, Embedded Controller Service Port, Security and Access Equipment, Instrumentation and Measurement Systems, Legacy Peripheral Connectivity.
Industrial PLC Serial Communication
The MAX3232EEUP+G1Z connects a 3.3 V or 5 V programmable controller to a legacy RS-232 service port. Its two drivers and two receivers support bidirectional point-to-point communication, while the 3.0 V to 5.5 V operating range aligns with common industrial control logic. The 1 Mbps capability provides substantial baud-rate headroom, and ±15 kV ESD protection strengthens the interface against cable-connected transients. Engineers should still design the enclosure, ground path, connector retention, and cable routing for the installation environment because IC-level protection does not replace industrial surge suppression.
추천
Data Acquisition and Test Equipment
The MAX3232EEUP+G1Z is useful in data-acquisition instruments and laboratory controllers that retain an RS-232 command or download port. A host UART can communicate through the IC's true RS-232 drivers and receivers, eliminating the need for external level translators in many designs. Its operation from 3.0 V to 5.5 V permits use beside both legacy 5 V logic and modern 3.3 V systems, while the 1 Mbps rating supports rapid command traffic. Preserve signal-to-noise margin by keeping the transceiver and its charge-pump capacitors away from analog inputs, clocks, and precision reference circuitry.
추천
Embedded Controller Service Port
The MAX3232EEUP+G1Z can provide a robust service and configuration port on an embedded controller, gateway, or industrial terminal. Its 3.0 V minimum supply voltage suits compact 3.3 V designs, and the true-RS-232 drivers generate the required positive and negative signal levels in one IC. The two-channel receiver arrangement is useful for handshake, status, or acknowledgment signals alongside a primary data channel. For field-service equipment, place a dedicated protection network near the connector and ensure chassis or signal-ground bonding follows the interface specification to avoid ESD-related resets or data corruption.
추천
Security and Access Equipment
The MAX3232EEUP+G1Z can support configuration or diagnostic links in access-control terminals, cameras, and intercom equipment. A compact 20-TSSOP package preserves board area, while ±15 kV ESD protection adds useful resilience for equipment connected to user-accessible cables. The two-driver/two-receiver arrangement permits bidirectional command exchange and hardware handshaking. Design the cable entry and connector shield carefully, because repeated cable handling can generate electrostatic discharge beyond the IC pins; retain short ground-return paths and place any supplementary surge-protection device close to the connector.
추천
Instrumentation and Measurement Systems
The MAX3232EEUP+G1Z suits laboratory instruments that communicate with host computers through RS-232. Its 1 Mbps maximum data rate is suitable for command traffic, calibration data, and moderate measurement-result transfers, while its 3.0 V to 5.5 V supply range allows flexible logic integration. True RS-232 signaling supports compatibility with older host equipment that requires bipolar levels. Keep the serial interface electrically separated from sensitive analog sections where practical, and verify grounding across bench instruments because ground-potential differences can overwhelm receiver margins even when the IC is operating correctly.
추천
Legacy Peripheral Connectivity
The MAX3232EEUP+G1Z provides a compact bridge between modern digital logic and legacy RS-232 peripherals such as printers, scanners, controllers, and service adapters. The +G1Z ordering configuration should be matched to the required production package and assembly process, while the electrical interface supports both 3.3 V and 5 V systems. Its integrated level translation reduces the number of discrete components required around a UART. Confirm connector gender, cable pin assignment, and whether hardware handshaking is required before finalizing the PCB, since software flow control and unsupported handshake pins should not be treated as interchangeable.
추천
추천 제품 요약
엔지니어링 참조 데이터: MAX3232EEUP+G1Z — 비교, 설계 지침 및 규정 준수 정보.
선택 가이드
대체품과의 비교
| 파라미터 | 이 제품 | MAX3232EEUP+ | MAX3232EEAE | MAX3232EETT | MAX3232ESA | MAX3232ESE |
|---|---|---|---|---|---|---|
| Package | 20-TSSOP, 4.40 mm width | 20-TSSOP, same footprint | 20-TSSOP, same footprint | 20-TSSOP, same footprint | 20-TSSOP, same footprint | 20-TSSOP, same footprint |
| Brand | Analog Devices | Analog Devices | Analog Devices | Analog Devices | Analog Devices | Analog Devices |
| Product Type | True RS-232 transceiver | True RS-232 transceiver | MAX3232E RS-232 transceiver family | MAX3232E RS-232 transceiver family | MAX3232E RS-232 transceiver family | MAX3232E RS-232 transceiver family |
| Industry-Standard Compatibility | Pin, package, and functionally compatible with MAX232 | MAX3232 family compatibility with MAX232 | MAX3232E family compatibility with MAX232 | MAX3232E family compatibility with MAX232 | MAX3232E family compatibility with MAX232 | MAX3232E family compatibility with MAX232 |
주요 차별점
- Maintains the documented MAX3232EEUP headline interface ratings (vs MAX3232EEUP+)
- Supports modern and legacy logic supply levels (vs MAX3232ESA)
- Combines bidirectional RS-232 conversion in a compact TSSOP (vs MAX3232EETT)
설계 노트
Place the four charge-pump capacitors close to their designated MAX3232EEUP+G1Z pins, using short traces and a common ground reference. Keep the compact charge-pump loop away from sensitive analog inputs, precision references, and clock circuits. Route the true RS-232 driver and receiver nets directly toward the protection network and connector, and avoid sharing narrow paths with clocks, switching regulators, or isolated communication barriers. This arrangement reduces loop area and limits coupling from the high-energy driver transitions into nearby measurement circuitry.
Do not treat RS-232 logic levels and TTL/CMOS levels as interchangeable. The MAX3232EEUP+G1Z converts between the UART-side logic signals and the bipolar RS-232 port, so the transceiver-side pins must connect to the controller UART while the line-side pins connect through the cable and connector. Verify DE-9 pin numbering, signal-ground selection, and hardware-handshake requirements. Substituting a TTL-level driver or an RS-485 transceiver into the same footprint can fail because the voltage levels, connector wiring, and fault behavior differ.
Connect the interface ground to the appropriate signal ground and keep the return path continuous between communicating systems. Ground-potential differences between two devices can reduce receiver margin or cause data corruption when a long cable ties their grounds together. Use the smallest practical loop area, shield the external cable according to the installation class, and terminate shields to chassis ground at the appropriate boundary. For long or electrically noisy installations, add qualified surge and ESD protection at the connector rather than relying solely on the IC's internal ±15 kV protection.
규정 준수 정보
The +G1Z ordering suffix and manufacturer documentation should be checked for the production configuration and environmental compliance status.