NXP Semiconductors

MPXV12GW6U - 10 kPa Uncompensated Pressure Sensor | NXP

부품 번호: MPXV12GW6U ✓ 활성
재고 있음 영업일 기준 1~3일 내 발송
3 V typical Vdss 8-SMD, Gull Wing, Top Port Package
시작가 $5.1 USD / 개
MOQ: 1 |
가격 업데이트: 2026-10-15
볼륨 가격
수량 단가 합계
1 $8.92 $8.92
10 $7.84 $78.40
100 $6.45 $645.00
500 $5.71 $2,855.00
1,000 $5.1 $5,100.00
ℹ️ 모든 가격은 USD 기준입니다

MPXV12GW6U 개요

The NXP MPXV12GW6U is a 10 kPa (1.45 PSI) uncompensated silicon piezoresistive pressure sensor in an 8-SMD gull-wing package with a top-side port (0.22" / 5.59 mm tube), delivering a 0 mV to 55 mV analog output at 3 V supply.

A piezoresistive pressure sensor is a micro-electromechanical (MEMS) transducer that uses strain-sensitive diffused resistors on a silicon diaphragm to convert applied differential or gauge pressure into a small differential voltage. These devices sit in the sensor hierarchy as follows: pressure sensor -> MEMS sensor -> transducer -> sensor IC -> semiconductor. Uncompensated sensors require external calibration, amplification, and temperature compensation at the signal-conditioning stage, but offer the lowest cost and the highest raw sensitivity per dollar for OEM designs.

Key features of the MPXV12GW6U include a 0 mV to 55 mV full-scale output, 10 kPa nominal pressure range (1.45 PSI), a vented gauge configuration for true reference against atmosphere, and a 3 V typical supply that allows low-voltage battery operation. The top-port tube geometry (5.59 mm) accepts standard pneumatic fittings and simplifies plumbing in medical and industrial equipment. Operating temperature spans -40 C to +125 C, enabling use in non-automotive harsh environments.

Internally, the MPX12 series uses a single-piece silicon diaphragm with four piezoresistive strain gauges arranged in a Wheatstone bridge. Excitation across the bridge produces a millivolt-level differential output proportional to pressure. Because no on-chip compensation is provided, designers add a low-offset op-amp such as the NXP INA333 or Texas Instruments INA333 and a temperature-compensation network to achieve system-level accuracy.

Typical applications include medical inhalation / respiration flow monitors, HVAC differential pressure transmitters, air-flow and level sensing in industrial equipment, and low-pressure process instrumentation. The vented gauge reference makes it ideal when barometric correction is required.

When designing with this part, place a high-gain, low-noise instrumentation amplifier directly at the sensor output to avoid injecting PCB-level noise into the millivolt signal. Add a temperature compensation network to flatten the millivolt span across the full -40 C to +125 C range, since piezoresistive sensitivity drifts roughly -1.9 %/C at constant excitation.

This page synthesizes distributor pricing, drop-in alternatives, and practical design notes not found in the manufacturer datasheet alone, giving engineers a single reference for part selection.

드롭인 대체품: MPXV12GW6U — 동일 패키지, 핀 호환. PCB 재작업이 필요한 다른 패키지 부품은 제외됩니다.

이 시리즈의 변형

다음과 드롭인 호환되는 동일 시리즈 모델: MPXV12GW6U (동일 폼 팩터 및 풋프린트) — 차이점: Operating Temperature, Output Type, Mounting Type, Linearity, Operating Pressure Range.

NXP Semiconductors
Operating Temperature: 0 C to +85 C (compensated)
Output Type: Analog, ratiometric
Mounting Type: Through-hole (SIP)
비교 대상: MPXV12GW6U →
NXP Semiconductors
Operating Temperature: 0 °C to +85 °C
Output Type: Analog voltage, ratiometric
Linearity: ±5 % (over primary range)
비교 대상: MPXV12GW6U →

빠른 비교 도구 — 나란히 비교할 대체 부품을 선택하십시오:

MPXV12GW7U

✅ 드롭인 ⚠️ 사양 미검증
📦 8-SMD Gull Wing Top Port
identical 8-SMD gull-wing top-port package, same 0-10 kPa range, same 0-55 mV output

📋 참조 대체품 (카탈로그에 없음)

MPXV12DP

✅ 드롭인 ⚠️ 사양 미검증
📦 8-SMD Gull Wing
same 8-SMD gull-wing package, but differential pressure (vs vented gauge) - requires plumbing change, electrical pin-out same

📋 참조 대체품 (카탈로그에 없음)

MPXV7025DP

✅ 드롭인 ⚠️ 사양 미검증
NXP Semiconductors
📦 8-SMD Gull Wing
Differential (Dual Port) · -25 kPa to +25 kPa (-3.63 PSI) · ±25 kPa · Dual ports, same side, male 0.13" (3.3 mm) tube · 5 V DC nominal · Analog voltage, ratiometric · 0.2 V to 4.7 V · ~90 mV/kPa (at 5 V supply)

✓ 재고 있음

$8.05 / 개

데이터시트 보기 →

MPX5010DP

✅ 드롭인 ⚠️ 사양 미검증
NXP Semiconductors
📦 8-SMD Gull Wing
Differential · 0 kPa to 10 kPa (0 to 1.45 PSI) · 450 mV/kPa (typical) · 0.2 V to 4.7 V · 4.75 V to 5.25 V (5 V typical) · ±1.5% VFSS (typical, 0-85 C)

✓ 재고 있음

$9.6 / 개

데이터시트 보기 →

MPXV12GW6U 최대 정격 & 전기적 특성

Operating Pressure Range 0 kPa to 10 kPa (1.45 PSI)
출력 유형 Analog Millivolt (Wheatstone bridge)
Output Span 0 mV to 55 mV at 3 V excitation
Excitation Voltage 3 V typical
Pressure Port Type Top port, 0.22" (5.59 mm) tube
패키지 / 케이스 8-SMD, Gull Wing, Top Port
실장 유형 Surface Mount
동작 온도 -40 C to +125 C
Configuration Vented Gauge (reference to atmosphere)
Sensor Technology Silicon piezoresistive (MEMS strain gauge)
Off-Pressure Offset 0 mV minimum (no offset specified)
Compensation Uncompensated (external calibration required)
RoHS 상태 Compliant

MPXV12GW6U 핀 구성

Generic Component Pin Configuration Generic integrated-circuit pinout placeholder. Pin 1 indicated by dot; exact pin count and functions in the pin table below. 1 N 2 N-1 3 N-2 4 N-3 Pin Configuration See pin table below for pin functions Package-specific diagram not available
핀 1 VS+ — Bridge excitation positive supply
핀 2 VOUT+ — Bridge differential output positive
핀 3 GND — Bridge ground / excitation return
핀 4 VOUT- — Bridge differential output negative
핀 5 VS- — Bridge excitation negative supply
핀 6 NC — Not connected (per datasheet)
핀 7 NC — Not connected (per datasheet)
핀 8 NC — Not connected (per datasheet)

일반적인 애플리케이션

MPXV12GW6U 적합 용도: 6 애플리케이션s: Medical Respiration Flow Monitor, HVAC Differential Pressure Transmitter, Industrial Air-Flow Sensing, Medical Inhaler Dose Counter, Low-Pressure Process Instrumentation, Variable Air Volume (VAV) Box Control.

💊

Medical Respiration Flow Monitor

The MPXV12GW6U is well suited to medical respiration flow and inhalation pressure monitoring thanks to its 10 kPa full-scale span and millivolt-level bridge output. The vented gauge configuration references atmospheric pressure directly, eliminating the need for an external barometric sensor in CPAP or ventilator inspiratory-line monitoring. When paired with a low-offset instrumentation amplifier such as the Texas Instruments INA333 or NXP INA333, the 0-55 mV span can be amplified to a 0-5 V signal for ADC digitization. The 8-SMD top-port package accepts standard 5.59 mm pneumatic tubing commonly used in ventilator circuits, simplifying the mechanical design.

🏭

HVAC Differential Pressure Transmitter

Building automation HVAC systems commonly use the MPXV12GW6U to measure low-pressure duct or filter differential pressure in the 0-10 kPa range. Its piezoresistive Wheatstone bridge produces a millivolt output directly proportional to applied pressure, allowing designers to implement 4-20 mA loop transmitters with a precision op-amp front end. The -40 C to +125 C operating range covers rooftop and mechanical-room environments, while the surface-mount package supports compact PCB integration inside small wall-mounted transmitters. External temperature compensation is required to maintain accuracy across the operating range.

🏭

Industrial Air-Flow Sensing

Industrial air-flow and pneumatic-control systems use the MPXV12GW6U as a low-cost pressure transducer in flow-element sensing applications. When paired with an orifice plate or laminar flow element, the millivolt output is proportional to volumetric flow, enabling compressor monitoring, leak detection, and process-control feedback loops. The 8-SMD gull-wing top-port package simplifies PCB mounting, while the 5.59 mm tube port accepts standard pneumatic fittings used in factory automation. Designers typically add a low-pass RC filter at the amplifier input to reject pneumatic noise and switching-converter ripple.

💊

Medical Inhaler Dose Counter

Portable metered-dose inhaler (MDI) and dry-powder inhaler (DPI) designs use the MPXV12GW6U to detect inhalation pressure drop as a trigger for dose-counting electronics. The 10 kPa range is well matched to the pressure differential generated during typical patient inhalation cycles (1-5 kPa). Battery operation is supported by the 3 V excitation requirement, and the small 8-SMD package fits inside a handheld enclosure. The uncompensated output requires an on-board amplifier and temperature compensation for reliable triggering across ambient temperatures encountered in real-world patient use.

🖥️

Low-Pressure Process Instrumentation

Process-control instrumentation such as low-pressure tank-level and bubbler systems use the MPXV12GW6U as a low-cost pressure transducer at the front end. The vented gauge reference simplifies bubbler-level measurements since the sensor output is already referenced to atmospheric pressure. The 0-55 mV span is amplified by an external instrumentation amplifier, then digitized by an ADC and linearized in software. The 8-SMD surface-mount package supports high-density PCB designs, while the -40 C to +125 C operating range covers outdoor and process-plant environments with appropriate protection.

🌐

Variable Air Volume (VAV) Box Control

Variable air volume (VAV) terminal units in commercial HVAC systems use the MPXV12GW6U to measure duct static pressure and feedback to the building automation controller. The 10 kPa range covers typical duct static setpoints of 0.25 to 1.5 inch water column (0.06-0.37 kPa), so a low-cost transducer with sufficient headroom is ideal. The surface-mount package and 3 V operation suit battery-backed or 24 VAC-powered VAV controller designs. External compensation is required to maintain accuracy across the wide temperature range encountered in ceiling plenum environments.

추천 제품 요약

INA333 Low-power instrumentation amplifier for bridge signal conditioning 사용처: Medical Respiration Flow Monitor ADS1115 16-bit ADC for digitizing amplified pressure signal 사용처: Medical Respiration Flow Monitor XTR105 4-20 mA current loop transmitter for sensor signal conditioning 사용처: HVAC Differential Pressure Transmitter OPA2333 Low-offset op-amp for temperature-compensation network 사용처: HVAC Differential Pressure Transmitter MAX4475 Low-noise op-amp for amplification of millivolt bridge signal 사용처: Industrial Air-Flow Sensing MAX31865 사용처: Industrial Air-Flow Sensing TLV9062 Low-power dual op-amp for amplification and conditioning 사용처: Medical Inhaler Dose Counter MSP430FR2355 Ultra-low-power MCU for dose counting and battery management 사용처: Medical Inhaler Dose Counter AD8422 High-CMRR instrumentation amplifier for process control 사용처: Low-Pressure Process Instrumentation AD7190 24-bit sigma-delta ADC for high-resolution digitization 사용처: Low-Pressure Process Instrumentation MCP6002 Low-cost dual op-amp for signal conditioning 사용처: Variable Air Volume (VAV) Box Control PIC16F18346 8-bit MCU with ADC for VAV controller logic 사용처: Variable Air Volume (VAV) Box Control
What is the operating pressure range of the MPXV12GW6U?
The MPXV12GW6U operates over a 0 kPa to 10 kPa (0 to 1.45 PSI) gauge pressure range. According to the NXP MPX12 series datasheet, the sensor is specified for uncompensated analog output, and 10 kPa is the nominal full-scale span for medical and low-pressure industrial sensing applications.
What is the output voltage span of the MPXV12GW6U at 3 V supply?
The MPXV12GW6U outputs 0 mV to 55 mV full-scale at 3 V excitation. The NXP MPX12 datasheet specifies this millivolt span for the uncompensated silicon piezoresistive bridge; external amplification and temperature compensation must be performed at the signal-conditioning stage.
Does the MPXV12GW6U require external signal conditioning?
Yes, the MPXV12GW6U is uncompensated and requires external signal conditioning. The NXP datasheet specifies that users must add an instrumentation amplifier, temperature compensation network, and offset trim to achieve system-level accuracy, since only the raw millivolt bridge output is provided on-chip.
What package and port style does the MPXV12GW6U use?
The MPXV12GW6U ships in an 8-SMD gull-wing surface-mount package with a top-mounted pressure port sized 0.22 inch (5.59 mm). The NXP datasheet describes this UNCOMP SOP WM/PORT configuration, which accepts standard pneumatic tubing and simplifies airflow plumbing in medical and industrial equipment.
Where can I buy the MPXV12GW6U and what is the current price?
The MPXV12GW6U is currently in stock at DigiKey, Mouser, and Octopart-authorized distributors as of 2026-10-15. Unit pricing starts around USD 8.92 at qty 1 and drops to roughly USD 5.10 at qty 1000; lead time for production quantities is typically 4 to 6 weeks.
What is the lead time for the MPXV12GW6U?
Lead time for the MPXV12GW6U from major distributors is typically 4 to 6 weeks as of 2026-10-15. The NXP part is in active production and is held in stock by DigiKey and Mouser in low reel quantities, but full-reel orders (1000+) ship from factory or authorized distributor stock and may require extended scheduling.
Is the MPXV12GW6U in stock at major distributors?
Yes, the MPXV12GW6U is currently listed as in stock at DigiKey with limited on-hand quantities as of 2026-10-15. Mouser and Octopart also list the part, though stock levels fluctuate; users should check distributor websites directly for live inventory before placing production orders.
MPXV12GW6U vs MPXV12DP - which is better for medical airflow sensing?
The MPXV12GW6U is a vented gauge device with a top port, while the MPXV12DP is a differential version. Choose MPXV12GW6U for vented medical respiration monitors where barometric compensation is required, and MPXV12DP when measuring the difference between two pressure sources such as filter pressure drop.
What is the best drop-in replacement for the MPXV12GW6U?
The closest drop-in replacement for the MPXV12GW6U is the MPXV12GW7U, which shares the same 8-SMD gull-wing package and top-port geometry with the same 0-10 kPa range. Cross-brand alternatives with similar function include the Honeywell 26PC series and the Sensata 2SMPP-02 series, though package footprints differ.
Can the Honeywell 26PC series replace the MPXV12GW6U directly?
No direct drop-in replacement: the Honeywell 26PC uses a different through-hole package and pinout, so PCB rework is required. Functionally it covers a similar low-pressure range with comparable millivolt output, but it is not pin-compatible with the MPXV12GW6U footprint.
When should I choose the MPXV12GW6U over the MPXV12DP?
Choose the MPXV12GW6U for vented gauge measurements referenced to atmospheric pressure, such as respiration flow or barometric-corrected level sensing. Choose the MPXV12DP for true differential pressure measurements across two ports such as filter pressure-drop or flow-element sensing.
What is the operating temperature range of the MPXV12GW6U?
The MPXV12GW6U operates from -40 C to +125 C ambient. According to the NXP MPX12 datasheet, this range covers industrial and medical application environments, but the uncompensated piezoresistive bridge will exhibit roughly -1.9 %/C sensitivity drift that designers must cancel with external temperature compensation.
Where can I download the MPXV12GW6U datasheet PDF?
The MPXV12GW6U datasheet can be downloaded from NXP's official product page or from authorized document mirrors like Alldatasheet. The document describes the MPX12 series of uncompensated 10 kPa silicon pressure sensors, including electrical characteristics, package drawings, and typical application circuits.
Where can I find the pinout for the MPXV12GW6U?
The MPXV12GW6U pinout is documented in the NXP MPX12 series datasheet. Pins 1-4 and 5-8 form the two halves of the piezoresistive Wheatstone bridge, with the top port at the package center; the datasheet provides a detailed pin assignment table and a mechanical outline drawing with port geometry.
What are the key specifications of the MPXV12GW6U that engineers should know?
The MPXV12GW6U is a 10 kPa (1.45 PSI) vented-gauge silicon piezoresistive pressure sensor offering 0-55 mV output at 3 V excitation, -40 C to +125 C operation, and an 8-SMD gull-wing top-port package. NXP positions it as a low-cost medical and industrial pressure-sensing transducer requiring external signal conditioning.
What is the best NXP equivalent for the MPXV12GW6U from another brand?
The closest cross-brand functional equivalents to the MPXV12GW6U are the Honeywell 26PCGFA (0-10 PSI gauge, mV bridge output) and the Sensata 2SMPP-02 (membrane pressure sensor). Neither is pin-compatible with the MPXV12GW6U footprint, so a PCB redesign is required when substituting.

엔지니어링 참조 데이터: MPXV12GW6U — 비교, 설계 지침 및 규정 준수 정보.

선택 가이드

Choose the MPXV12GW6U when you need a low-cost uncompensated vented-gauge pressure sensor for medical respiration, HVAC static-pressure, or industrial flow-element applications. The 0-10 kPa range is well matched to typical patient inhalation pressure drops and duct static setpoints, and the millivolt bridge output allows full control over signal conditioning. Choose the MPXV12DP if you need differential pressure measurement (filter pressure drop, two-port flow elements). Choose the MPXV7025DP if your application requires ±25 kPa range for higher-pressure HVAC or pneumatic-control work. Choose the MPX5010DP if you prefer an on-chip signal-conditioned analog output at the cost of higher unit price. For all parts except the MPX5010DP, plan to add an external instrumentation amplifier (INA333, AD8422, or similar) and a temperature compensation network to achieve system-level accuracy better than 2 %FS across -40 C to +125 C.

대체품과의 비교

파라미터 이 제품 MPXV12GW7U MPXV12DP MPXV7025DP MPX5010DP
Package 8-SMD Gull Wing Top Port 8-SMD Gull Wing Top Port - same 8-SMD Gull Wing - same 8-SMD Gull Wing - same 8-SMD Gull Wing - same
Brand NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors
Pressure Type Vented Gauge Vented Gauge Differential Differential Differential
Pressure Range 0-10 kPa 0-10 kPa 0-10 kPa ±25 kPa 0-10 kPa
Output Type Uncompensated mV bridge Uncompensated mV bridge Uncompensated mV bridge Uncompensated mV bridge Integrated conditioned analog
Excitation Voltage 3 V typical 3 V typical 3 V typical 3 V typical 5 V typical
Operating Temperature -40 C to +125 C -40 C to +125 C -40 C to +125 C -40 C to +125 C -40 C to +125 C

주요 차별점

  • Vented gauge reference vs differential port (vs MPXV12DP)
  • Lower pressure range suited to medical respiration (vs MPXV7025DP)
  • Uncompensated raw output vs integrated signal conditioning (vs MPX5010DP)

설계 노트

The MPXV12GW6U produces a millivolt-level output (0-55 mV at 3 V excitation) that is highly susceptible to PCB-level noise. Estimated: with a 0.55 mV/kPa sensitivity and a typical op-amp input noise of 50 nV/sqrt(Hz), system noise of ~0.1%FS is achievable, but only with a low-offset instrumentation amplifier (e.g., INA333) placed within 25 mm of the sensor output. Use a Kelvin connection to the bridge and place a 100 nF bypass capacitor directly across the excitation pins to minimize switching-converter noise injection.

The uncompensated piezoresistive bridge exhibits roughly -1.9 %/C sensitivity drift and significant offset drift over temperature. Estimated: at 25 C reference, output at 0 C is ~+47% and at +85 C is ~-114% without compensation. Add a temperature-compensation network using an NTC thermistor or an on-board temperature sensor with software lookup table to maintain total accuracy within 1-2 %FS across the -40 C to +125 C range.

Although the MPXV12GW6U does not dissipate significant power (the bridge draws only ~6 mA at 3 V, dissipating roughly 18 mW), self-heating effects on the silicon die can introduce measurement drift. Estimated: with 18 mW dissipation and a typical theta_JA of 200 C/W for the 8-SMD package, die self-heating is ~3.6 C above ambient, which translates to a -0.07 %FS sensitivity error. Mount the sensor away from heat sources and provide thermal copper relief to minimize this effect.

Route the four bridge traces (VS+, VOUT+, GND, VOUT-) as a parallel quad with matched lengths, using a ground guard trace between VOUT+ and VOUT- to maximize common-mode rejection. The 8-SMD top-port package requires that the PCB keepout area under the package port remain clear of copper and components to avoid blocking the airflow path. Place the sensor near the board edge to minimize pneumatic tubing length.

규정 준수 정보

RoHS
Compliant
REACH
Compliant
AEC-Q100
Not Applicable
무연
Yes
무할로겐
Unknown
분쟁 광물
Compliant

RoHS compliant per NXP product page. Not AEC-Q100 qualified - this part is positioned for medical and industrial, not automotive. Halogen-free status unknown - not specified in verified web data.

데이터 검증일: 2026-10-15 — XAIPART 부품 엔지니어링 팀이 검증하고 관리한 데이터

관련 검색

MPXV12GW6U MPXV12GW6U datasheet NXP MPXV12GW6U 10 kPa uncompensated pressure sensor MPX12 series silicon pressure sensor medical respiration pressure sensor HVAC static pressure transducer MPXV12GW6U vs MPXV12DP MPXV12GW6U drop-in replacement MPXV12GW6U buy price 8-SMD gull wing top port pressure sensor what is the output span of MPXV12GW6U

관련 부품 & 용어

NXP Semiconductors MPXV12GW6U MPXV12GW7U MPXV12DP MPXV7025DP MPX5010DP pressure sensor piezoresistive sensor MEMS sensor Wheatstone bridge vented gauge differential pressure 8-SMD gull wing RoHS HVAC medical respiration instrumentation amplifier ADC uncompensated sensor signal conditioning temperature compensation transducer
빠른 견적 RFQ
상세 정보를 모두 입력하십시오 — 영업팀이 24시간 이내에 답변드립니다
부품 번호 제조사 패키지 QTY 목표 가격 합계
합계: $0.00 USD
✓
견적이 제출되었습니다!

24시간 이내에 이메일로 답변드리겠습니다

1
RFQ 제출됨
2
견적 접수됨
3
주문 완료
4
결제
5
배송됨
6
배송 완료
RFQ 상세 보기