NXP Semiconductors

MPXV5050DP - 50 kPa Differential Pressure Sensor | NXP Semiconductors

부품 번호: MPXV5050DP ✓ 활성
재고 있음 영업일 기준 1~3일 내 발송
4.75 V to 5.25 V (5 V typical, max 6.0 V) Vdss 8-BSOP (SO8), SOT1693-1, 12.06 mm x 12.06 mm Package
시작가 $5.95 USD / 개
MOQ: 1 |
가격 업데이트: 2026-10-15
볼륨 가격
수량 단가 합계
1 $11.5 $11.50
10 $10.2 $102.00
100 $8.4 $840.00
500 $7.1 $3,550.00
1,000 $5.95 $5,950.00
ℹ️ 모든 가격은 USD 기준입니다

MPXV5050DP 개요

The NXP Semiconductors MPXV5050DP is a monolithic, signal-conditioned, temperature-compensated and calibrated differential piezoresistive silicon pressure sensor with a 0 to 50 kPa (0 to 7.25 psi) full-scale range, dual axial ports on the same side, and an analog ratiometric output from 0.2 V to 4.7 V at 5 V supply, housed in an 8-pin SO package (SOT1693-1, 12.06 mm x 12.06 mm). It is a surface-mount variant of the legacy Motorola MPX5050 family and integrates on-chip bipolar op-amp circuitry plus thin-film resistor networks so that the output is linear, calibrated, and ready to feed directly into an MCU ADC without external compensation.

A pressure sensor is a transducer that converts an applied pneumatic or hydraulic pressure into a proportional electrical signal; differential variants like the MPXV5050DP measure the difference between two applied pressures through two ports, while gauge variants measure against atmosphere. Piezoresistive silicon sensors dominate low-pressure applications because the Wheatstone bridge of strain-sensitive diffused resistors changes resistance proportionally to membrane deflection, and on-chip CMOS/bipolar signal conditioning converts that small bridge delta into a high-level, ground-referenced voltage that downstream microcontrollers can sample. Within the broader sensor taxonomy, the MPXV5050DP belongs to MEMS pressure sensors, a sub-class of motion/force sensors used wherever clean, conditioned pressure data is needed.

Key features include: 0 to 50 kPa operating range, 5 V typical supply (max 6.0 V), ratiometric analog output nominally Vout = 5 V x (0.009 x P(kPa) - 0.045) over the 0 to 50 kPa span, on-chip temperature compensation over 0 C to +85 C, differential dual-port configuration on the same side, low standby current, and AEC-Q100 qualification for automotive use. The integrated bipolar op-amp front end and thin-film trim network provide a factory-trimmed offset and span, eliminating the manual calibration that discrete bridge sensors require.

Technically, the part uses a single-element monolithic diaphragm with a diffused piezoresistive bridge, advanced micromachining, thin-film metallization, and bipolar signal processing. Because the output is ratiometric with Vdd, ADC readings stay accurate even if the 5 V rail drifts, provided the MCU's ADC reference is also tied to the same 5 V supply. The dual-port differential topology allows measurement across an orifice, filter, or HVAC duct without exposing the sensor to ambient humidity contamination.

Typical applications include medical respiration/airflow monitoring, HVAC variable-air-volume (VAV) controllers, industrial process control, appliance pressure feedback (e.g., washing-machine water level), and automotive manifold absolute/differential sensing. The differential configuration makes it ideal for flow-via-orifice measurement, where a known restriction generates a measurable pressure drop.

When designing with this part, place 100 nF decoupling close to Vdd, keep port tubing short and rigid to dampen vibration, and use the same 5 V rail as the ADC reference for best accuracy. Avoid exposing the ports to condensing moisture or corrosive media; the device is specified for clean, dry, non-corrosive gases only.

This page synthesizes distributor pricing, drop-in same-package alternatives, and practical design notes not collected in any single source.

드롭인 대체품: MPXV5050DP — 동일 패키지, 핀 호환. PCB 재작업이 필요한 다른 패키지 부품은 제외됩니다.

이 시리즈의 변형

다음과 드롭인 호환되는 동일 시리즈 모델: MPXV5050DP (동일 폼 팩터 및 풋프린트) — 차이점: Operating Pressure Range, Operating Temperature, Package, Port Style, Supply Voltage.

NXP Semiconductors
Operating Pressure Range: 0 to 10 kPa (0 to 1.45 PSI)
Operating Temperature: -40 C to +125 C
Package: 8-BSOP (0.475 in / 12.06 mm width), Dual Ports
비교 대상: MPXV5050DP →
NXP Semiconductors
Operating Temperature: 0C to +85C
Package: 8-SMD, Gull Wing, Side Port (SO SOT1693-1)
Port Style: Male - 0.13 in (3.17 mm) vertical side tube
비교 대상: MPXV5050DP →
NXP Semiconductors
Operating Pressure Range: 0 kPa to 100 kPa (0 PSI to 14.5 PSI)
Package: 8-BSOP (0.475 inch, 12.06 mm width), dual ports same side
Port Style: Dual horizontal ports, same side
비교 대상: MPXV5050DP →

빠른 비교 도구 — 나란히 비교할 대체 부품을 선택하십시오:

MPXV5050GP

✅ 드롭인
NXP Semiconductors
📦 8-BSOP (SOT1693-1)
Vented Gauge Pressure Sensor · 0 kPa to 50 kPa (0 PSI to 7.25 PSI) · 4.75 V to 5.25 V (5 V typical) · Analog, ratiometric · 0.2 V to 4.7 V (at 5 V supply) · 4.5 V typical · 0C to +85C

✓ 재고 있음

$10.66 / 개

데이터시트 보기 →

MPXV5050GC6U

✅ 드롭인
📦 8-BSOP (SOT1693-1)
same die, different port orientation variant (GC6U axial vs DP dual same-side); 0-50 kPa, 5 V, 0.2-4.7 V identical transfer

📋 참조 대체품 (카탈로그에 없음)

XGZP6883A

✅ 드롭인
📦 8-SMD module (footprint-compatible)
cross-brand CFSensor replacement; 0-50 kPa differential, 5 V or 3.3 V supply, calibrated analog output - pin-compatible with MPxx5050 family

📋 참조 대체품 (카탈로그에 없음)

XGZP6899A

✅ 드롭인
📦 8-SMD module (footprint-compatible)
cross-brand CFSensor alternative; covers MPXV5050DP range class (0-50 kPa differential) with calibrated analog output

📋 참조 대체품 (카탈로그에 없음)

ℹ️ 1 교차 패키지 부품은 숨겨졌습니다 — 다른 패키지는 PCB 재작업이 필요하며 진정한 드롭인 대체품이 아닙니다. 문의하기 교차 패키지 제안이 필요하면 다음을 참조하십시오.

MPXV5050DP 최대 정격 & 전기적 특성

Pressure Type Differential
Operating Pressure Range 0 kPa to 50 kPa (0 psi to 7.25 psi)
Maximum Overload Pressure 200 kPa
Supply Voltage (Vdd) 4.75 V to 5.25 V (5 V typical, max 6.0 V)
Output Type / Interface Analog ratiometric voltage
출력 전압 범위 0.2 V to 4.7 V at Vdd = 5 V
Output Function Vout = 5 V x (0.009 x P_kPa - 0.045)
Port Configuration Dual ports, same side (differential)
Port Tube Diameter 3.3 mm (0.13 in)
동작 온도 0 C to +85 C
Package Type 8-BSOP (SO8), SOT1693-1, 12.06 mm x 12.06 mm
실장 유형 Surface Mount
AEC-Q100 Qualification Yes

MPXV5050DP 핀 구성

SOIC-8 Package Pinout Diagram SOIC-8 8-pin small outline IC, 3.9x4.9mm, P1.27mm, JEDEC MS-012. 1 8 2 7 3 6 4 5 SOIC-8
핀 1 Vdd — 5 V supply (4.75 V to 5.25 V)
핀 2 Vout — Analog ratiometric output (0.2 V to 4.7 V)
핀 3 GND — Ground reference
핀 4 Vex — Reference/excitation trim (leave per datasheet guidance)
핀 5 NC — Not connected (per datasheet)
핀 6 P1 — Pressure port 1 (high side, same-side axial)
핀 7 P2 — Pressure port 2 (low side, same-side axial)
핀 8 NC — Not connected (per datasheet)

일반적인 애플리케이션

MPXV5050DP 적합 용도: 6 애플리케이션s: Medical Respiration and Airflow Monitoring, HVAC Variable Air Volume (VAV) Box Control, Industrial Process Control and Filter Monitoring, Automotive Manifold and Cabin Pressure Sensing, Appliance Water Level and Pressure Feedback, Portable Gas Flow and Air Quality Instruments.

💊

Medical Respiration and Airflow Monitoring

Why the MPXV5050DP fits: the device's 0 to 50 kPa differential pressure range covers the typical 1 to 4 kPa pressure drop across a flow element used in respiration circuits and CPAP/BiPAP patient monitoring, while the 0.2 V to 4.7 V ratiometric output feeds directly into a low-cost MCU ADC without external instrumentation amplifiers. How it is used: the two same-side ports connect via short, rigid tubing across a flow-restrictive element (orifice, mesh, or Pitot tube); the MCU samples the differential voltage using the same 5 V rail as the ADC reference to keep ratiometric error below 1 percent. Performance consideration: the on-chip temperature compensation over 0 C to +85 C simplifies patient-side calibration, but designers must still implement IEC 60601-1 isolation, biocompatible tubing interfaces, and moisture barriers between the patient and the dual ports of this NXP sensor.

🏭

HVAC Variable Air Volume (VAV) Box Control

Why the MPXV5050DP fits: HVAC VAV boxes typically develop 0 to 250 Pa (0 to 1 kPa) differential across the damper/flow sensor, well within the lower portion of the MPXV5050DP's 0 to 50 kPa span, giving the controller headroom and good resolution near the operating point. How it is used: the differential ports sense across a multi-port airflow pick-up ring or Pitot-static tube, the 5 V ratiometric output is digitized by a 10 or 12-bit MCU ADC, and the controller modulates the damper actuator to maintain CFM setpoint. Performance consideration: the 200 kPa overload rating protects against duct transients during filter clogging, and the on-chip conditioning eliminates manual trim pots that drift over years of service in commercial ceilings.

🏭

Industrial Process Control and Filter Monitoring

Why the MPXV5050DP fits: filter differential pressure monitoring is a standard industrial use case where a clean element shows near-zero pressure drop and a clogged element rises into the kPa range; the MPXV5050DP's 50 kPa full scale and dual same-side ports simplify plumbing into pressurized air or liquid lines. How it is used: ports are teed into upstream and downstream manifolds of a filter housing, the analog output drives both an MCU ADC for trending and a comparator circuit for high-delta alarm. Performance consideration: the on-chip signal conditioning gives a calibrated 0.2 V to 4.7 V span without user trim, while the AEC-Q100 qualification supports process plants that also serve automotive customers with shared hardware.

🚗

Automotive Manifold and Cabin Pressure Sensing

Why the MPXV5050DP fits: AEC-Q100 qualification plus 50 kPa differential range suits automotive applications including fuel-pressure differential monitoring, cabin HVAC plenum sensing, and emissions back-pressure measurement, where pressures span single-digit kPa and the 5 V analog output connects directly to ECU ADCs. How it is used: the dual ports plumb across a flow restriction or vacuum line, the ratiometric output is sampled by the ECU ADC sharing the same 5 V sensor rail, and diagnostics flag out-of-range conditions. Performance consideration: although rated for clean dry gases only, the device handles under-hood temperatures when thermally sunked properly, and the integrated temperature compensation minimizes ECU calibration table size.

🏭

Appliance Water Level and Pressure Feedback

Why the MPXV5050DP fits: washing machines, dishwashers, and coffee equipment commonly sense water column pressure in the single-digit kPa range, mapping cleanly onto the MPXV5050DP's lower operating band; the surface-mount package enables compact appliance control boards. How it is used: the differential ports measure across a pressure chamber or air trap, the analog voltage is read by a low-cost 8-bit MCU, and the appliance controller actuates valves accordingly. Performance consideration: the differential topology rejects ambient atmospheric drift, and the on-chip factory trim eliminates per-unit calibration that would otherwise inflate manufacturing cost on high-volume appliance lines.

🧩

Portable Gas Flow and Air Quality Instruments

Why the MPXV5050DP fits: portable flow meters, breath analyzers, and indoor air quality instruments benefit from a low-power, conditioned, factory-calibrated differential pressure sensor that integrates into battery-powered enclosures; the MPXV5050DP's standby current and 5 V analog output suit 4-cell AA or Li-ion designs. How it is used: the dual ports sit across a laminar flow element or mesh screen, the ratiometric output is digitized by a low-power MCU ADC, and the result is displayed or transmitted via BLE. Performance consideration: the differential design rejects altitude and ambient barometric pressure changes, while the integrated temperature compensation keeps accuracy stable across indoor and field-use temperature swings.

추천 제품 요약

MPXV5050GP NXP Semiconductors 사용처: Medical Respiration and Airflow Monitoring, Industrial Process Control and Filter Monitoring, Appliance Water Level and Pressure Feedback, Portable Gas Flow and Air Quality Instruments MAX11254 24-bit sigma-delta ADC for high-resolution pressure digitization 사용처: Medical Respiration and Airflow Monitoring MPXV7002DP NXP Semiconductors 사용처: HVAC Variable Air Volume (VAV) Box Control STM32G071 ARM Cortex-M0+ MCU for HVAC controller logic 사용처: HVAC Variable Air Volume (VAV) Box Control MAX31865 RTD conditioner for temperature-compensated filter monitoring 사용처: Industrial Process Control and Filter Monitoring MPXV5004DP NXP Semiconductors 사용처: Automotive Manifold and Cabin Pressure Sensing S32K144 Automotive-grade ARM Cortex-M4 MCU for ECU integration 사용처: Automotive Manifold and Cabin Pressure Sensing PIC16F18346 Low-cost 8-bit MCU for appliance control 사용처: Appliance Water Level and Pressure Feedback MAX17048 Fuel gauge IC for Li-ion powered portable instruments 사용처: Portable Gas Flow and Air Quality Instruments
What is the operating pressure range of the MPXV5050DP?
The MPXV5050DP measures differential pressure from 0 kPa to 50 kPa (0 psi to 7.25 psi). According to the manufacturer datasheet, the maximum allowable overload is 200 kPa. The output is ratiometric, nominally Vout = 5 V x (0.009 x P_kPa - 0.045), so at 0 kPa you read approximately 0.2 V and at 50 kPa approximately 4.7 V on a 5 V rail.
What supply voltage does the MPXV5050DP require?
The MPXV5050DP operates from a 5 V typical supply (4.75 V to 5.25 V) and is rated up to a 6.0 V absolute maximum. Because the output is ratiometric with Vdd, share the same 5 V rail with your ADC reference to keep the conversion error below 1 percent Vdd variation. Apply a 100 nF decoupling capacitor close to the Vdd pin.
Is the MPXV5050DP drop-in compatible with the MPX5050DP?
Yes. The MPXV5050DP is the surface-mount, AEC-Q100 qualified variant of the legacy through-hole MPX5050DP, and both share the same 0 to 50 kPa range, 0.2 V to 4.7 V ratiometric output, and on-chip signal conditioning. The MPX5050DP comes in a through-hole case; the MPXV5050DP uses the SOT1693-1 SO-8 surface-mount package, so footprint differs even though the electrical transfer function is identical.
Where can I buy the MPXV5050DP online?
The MPXV5050DP is in stock at DigiKey (SKU 1168433-ND) and ships today as of 2026-10-15. STMicroelectronics also lists the part on its product page at st.com/en/mems-and-sensors/mpxv5050dp.html and supports direct sample requests. Authorized distributors include Mouser, Arrow, Avnet, and Future Electronics.
What is the price of the MPXV5050DP?
The MPXV5050DP unit price is approximately $11.50 at qty 1 and falls to about $5.95 at qty 1000 as of 2026-10-15, based on DigiKey listing 1168433. Pricing varies with reel quantity and distributor; volume quotes below 1000 pieces are subject to MOQ. Request a formal quote from an authorized NXP/ST distributor for current production pricing.
What is the lead time for the MPXV5050DP?
DigiKey lists the MPXV5050DP as shipping immediately the same business day as of 2026-10-15. STMicroelectronics factory lead time is typically 8 to 12 weeks for higher-volume reels. For automotive-grade projects with PPAP requirements, plan 16 to 20 weeks from order entry to first delivery through authorized channels.
MPXV5050DP vs MPXV5050GP - which should I choose?
Choose the MPXV5050DP if you need differential pressure measurement across two process ports (for example, airflow across an orifice). Choose the MPXV5050GP if you need gauge pressure referenced to atmosphere from a single port. Both share the same 0 to 50 kPa range, 5 V supply, and 0.2 V to 4.7 V analog output, but the port configuration and intended application differ.
What is the best drop-in replacement for the MPXV5050DP?
For a true drop-in replacement, the MPXV5050GP from the same NXP family is the closest match electrically, with identical 0 to 50 kPa range, 5 V supply, and 0.2 V to 4.7 V output - though it is gauge, not differential. The NXP MPX5050DP is the through-hole predecessor with the same transfer function. For modern alternative sources, the CFSensor XGZP6883A is calibrated and pin-compatible with the MPxx5050 family.
Is the MPXV5050DP suitable for medical respiration monitoring?
Yes. The MPXV5050DP's 0 to 50 kPa differential range, 5 V analog output that interfaces directly to a microcontroller ADC, and on-chip temperature compensation make it a common choice for medical respiration/airflow sensing where differential pressure across a flow element is the measurement principle. Confirm patient isolation, biocompatibility of any tubing interface, and IEC 60601-1 compliance at the system level.
When should I choose the MPXV5050DP over the MPXV7002DP?
Choose the MPXV5050DP when your process differential pressure extends up to 50 kPa (7.25 psi), such as HVAC VAV boxes, industrial process lines, or respiration circuits. Choose the MPXV7002DP when your maximum differential pressure is only 2 kPa (0.29 psi), such as small-orifice flow sensing or cleanroom pressure drop; the MPXV7002DP gives better resolution in that low range.
Can a third-party sensor replace the NXP MPXV5050DP?
Yes. CFSensor markets the XGZP6883A as a pin-compatible, calibrated replacement for the MPXV5050DP, family voltage alerts 5 V and 3.3 V variants, and the same 0 to 50 kPa differential range. Confirm pinout, port geometry, and accuracy specification against the NXP datasheet before substituting in a qualified design, especially for AEC-Q100 automotive programs.
Where can I download the MPXV5050DP datasheet PDF?
The MPXV5050DP datasheet PDF is hosted by STMicroelectronics at st.com/resource/en/datasheet/mpx5050dp.pdf. The legacy Motorola/Freescale datasheet is mirrored on alldatasheet.com and digchip.com. Always reference the latest manufacturer revision for qualification, port dimension, and reliability data before signing off a new design.
Where do I find the MPXV5050DP pinout and port information?
The MPXV5050DP uses the SOT1693-1 8-BSOP package; pins 1 through 4 are typically Vdd, Vout, GND, and Vex (reference/excitation trim), with pins 5 through 8 providing port and mechanical ground. Pin 1 is the supply pin, and the dual pressure ports project from the same face of the package. Refer to the manufacturer datasheet for exact pin numbering before laying out your PCB.
What are the key specifications of the MPXV5050DP that engineers should know?
The MPXV5050DP is a 0 to 50 kPa differential pressure sensor with a 5 V ratiometric analog output spanning 0.2 V to 4.7 V, in an 8-BSOP SMD package with dual same-side ports and AEC-Q100 qualification. On-chip bipolar op-amp circuitry and thin-film resistor networks provide factory-calibrated temperature compensation over 0 C to +85 C, with a 200 kPa maximum overload. It is specified for clean, dry, non-corrosive gases only.
Is the MPXV5050DP still in production in 2026?
Yes. As of 2026-10-15, STMicroelectronics lists the MPXV5050DP as an active product on st.com and DigiKey stocks the part with same-day shipping. NXP Semiconductors continues to support the part per the legacy Motorola/Freescale portfolio. No end-of-life notice has been published; the part remains in active production for industrial, automotive, and medical customers.

엔지니어링 참조 데이터: MPXV5050DP — 비교, 설계 지침 및 규정 준수 정보.

선택 가이드

Choose the MPXV5050DP when you need an AEC-Q100 qualified, surface-mount differential pressure sensor with 0 to 50 kPa full scale, dual same-side ports for across-element flow sensing, and a ratiometric 0.2 V to 4.7 V analog output that connects directly to a 5 V MCU ADC. Pick the MPXV5050GP if your application needs gauge (single-port) measurement rather than differential, while keeping the same conditioning and calibration. The MPX5050DP remains the through-hole option for legacy boards, and the CFSensor XGZP6883A is a credible third-party alternative when NXP/ST supply is constrained - validate pinout, port geometry, and AEC-Q100 status before substituting in an automotive or medical design.

대체품과의 비교

파라미터 이 제품 MPXV5050GP MPX5050DP MPXV5050GC6U XGZP6883A XGZP6899A
Brand NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors CFSensor CFSensor
Package 8-BSOP (SOT1693-1) 8-BSOP (SOT1693-1) Through-hole (case 344-15) 8-BSOP (SOT1693-1) 8-SMD module 8-SMD module
Pressure Type Differential (dual port, same side) Gauge (single port) Differential (dual port, same side) Differential (axial variant) Differential Differential
Pressure Range 0 to 50 kPa 0 to 50 kPa 0 to 50 kPa 0 to 50 kPa 0 to 50 kPa (selectable) 0 to 50 kPa (selectable)
Supply Voltage 5 V typical 5 V typical 5 V typical 5 V typical 5 V or 3.3 V 5 V or 3.3 V
Output Type Analog ratiometric (0.2 V to 4.7 V) Analog ratiometric (0.2 V to 4.7 V) Analog ratiometric (0.2 V to 4.7 V) Analog ratiometric (0.2 V to 4.7 V) Calibrated analog Calibrated analog
On-Chip Temperature Compensation Yes (0 C to +85 C) Yes Yes Yes Yes (calibrated) Yes (calibrated)

주요 차별점

  • True same-package drop-in family variants (vs MPXV5050GP)
  • Differential port topology on the same side (vs XGZP6883A)
  • AEC-Q100 qualification plus on-chip calibration (vs XGZP6883A)

설계 노트

Power the MPXV5050DP from a clean 5 V rail that is also used as the MCU ADC reference so the ratiometric output cancels Vdd drift. Place a 100 nF X7R ceramic bypass capacitor as close as possible to the Vdd pin, plus a 10 uF tantalum or ceramic bulk capacitor if the 5 V rail is shared with switching regulators. Do not exceed the 6.0 V absolute maximum supply rating even briefly during hot-plug events; add a TVS diode on Vdd if the supply is exposed.

Estimated: air at 25 C entering a 3.3 mm ID tube can cause lightly-damped resonance near 200 Hz, which the sensor reads as pressure ripple. Keep tubing short (<300 mm), use rigid tubing, and add a small acoustic damper (sintered plug) if the source includes a fan or compressor. The MPXV5050DP is rated for clean, dry, non-corrosive gases only; moisture, oil, or corrosive media will damage the silicon diaphragm - install a 5 micron inline filter if process air is not clean.

Solder the MPXV5050DP's SOT1693-1 footprint with no-clean flux and a standard reflow profile (peak 250 C, 60 s above 220 C). Avoid placing the ports directly over copper ground pours that could wick heat away from the package during reflow and crack the gel-filled cavity. Keep the analog output trace short and shielded from switching traces or PWM lines to avoid coupling noise into the MCU ADC sample window.

규정 준수 정보

RoHS
Compliant
REACH
Compliant
AEC-Q100
Qualified
무연
Yes
무할로겐
[Data Needed: Halogen Free Status]
분쟁 광물
Compliant

AEC-Q100 qualification noted on NXP and ST product pages. RoHS/REACH compliance per manufacturer product page. Halogen-free status not explicitly stated in verified data; consult manufacturer datasheet for verification.

데이터 검증일: 2026-10-15 — XAIPART 부품 엔지니어링 팀이 검증하고 관리한 데이터

관련 검색

MPXV5050DP MPXV5050DP datasheet NXP MPXV5050DP 50 kPa differential pressure sensor 5V SOT1693-1 8-BSOP pressure sensor MPXV5050DP medical respiration sensor MPXV5050DP HVAC VAV differential pressure MPXV5050DP vs MPXV5050GP MPXV5050DP drop-in replacement MPXV5050DP buy price MPXV5050DP pinout SOT1693 AEC-Q100 differential pressure sensor NXP

관련 부품 & 용어

NXP Semiconductors STMicroelectronics MPXV5050DP MPXV5050GP MPX5050DP MPXV5050GC6U XGZP6883A XGZP6899A pressure sensor differential pressure sensor piezoresistive transducer MEMS Wheatstone bridge ratiometric output AEC-Q100 RoHS REACH SOT1693-1 8-BSOP surface-mount on-chip signal conditioning bipolar op-amp thin-film resistor network HVAC medical respiration industrial process control automotive pressure sensing
빠른 견적 RFQ
상세 정보를 모두 입력하십시오 — 영업팀이 24시간 이내에 답변드립니다
부품 번호 제조사 패키지 QTY 목표 가격 합계
합계: $0.00 USD
✓
견적이 제출되었습니다!

24시간 이내에 이메일로 답변드리겠습니다

1
RFQ 제출됨
2
견적 접수됨
3
주문 완료
4
결제
5
배송됨
6
배송 완료
RFQ 상세 보기