STMicroelectronics

MPXV5050VC6T1 - 50 kPa Vacuum Pressure Sensor, 5V, SOP-8

부품 번호: MPXV5050VC6T1 ✓ 활성
재고 있음 영업일 기준 1~3일 내 발송
4.75 V to 5.25 V (typical 5.0 V) Vdss 5 mA typical Id
시작가 $8.95 USD / 개
MOQ: 1 |
가격 업데이트: 2026-10-15
볼륨 가격
수량 단가 합계
1 $14.5 $14.50
10 $13.05 $130.50
100 $11.55 $1,155.00
500 $10.2 $5,100.00
1,000 $8.95 $8,950.00
ℹ️ 모든 가격은 USD 기준입니다

MPXV5050VC6T1 개요

The STMicroelectronics (formerly NXP/Freescale) MPXV5050VC6T1 is a monolithic, signal-conditioned, silicon piezoresistive pressure sensor in an 8-SMD gull-wing (SOP-8, case 1737-02) package with a top-side vertical tube port. It measures vacuum and gauge pressure from 0 to -50 kPa (-7.25 PSI) and produces a ratiometric analog output of 0.1 V to 4.6 V from a single 5 V supply, calibrated directly by on-chip bipolar op-amp and thin-film resistor networks.

What is a piezoresistive pressure sensor? A piezoresistive pressure sensor is a MEMS device in which four silicon piezoresistors arranged in a Wheatstone bridge on a diaphragm change resistance in proportion to applied strain. As pressure deflects the diaphragm, the bridge output is amplified and conditioned by on-chip circuitry to deliver a high-level, temperature-compensated analog voltage proportional to pressure, eliminating the external instrumentation amplifier and calibration steps normally required for bare bridge sensors.

The MPXV5050VC6T1 family is rated for a pressure range of 0 to -50 kPa (vacuum mode) with a sensitivity of 90 mV/kPa and a 5 V supply span. The integrated signal chain delivers 5% accuracy over 0°C to 85°C, on-chip temperature compensation, and a typical response time suitable for industrial, medical, and HVAC closed-loop control. The SOP-8 surface-mount form factor with top port and 0.13 inch (3.17 mm) tube port allows direct manifold mounting and high-volume pick-and-place assembly.

Typical applications include vacuum pump monitoring, HVAC airflow sensing, respirator and ventilator pressure feedback, barometric altitude estimation, and industrial process control where a conditioned 0.1 V to 4.6 V analog output can be read directly by an MCU ADC.

When designing with this part, decouple VCC with a 100 nF ceramic capacitor placed within 5 mm of the supply pin, and add a 1 µF bulk capacitor on the supply rail. Drive the analog output through an RC low-pass filter if the application samples at less than the sensor's response bandwidth to avoid aliasing.

This page synthesizes distributor pricing, drop-in alternatives, application notes, and pin-level design notes that go beyond the manufacturer datasheet.

드롭인 대체품: MPXV5050VC6T1 — 동일 패키지, 핀 호환. PCB 재작업이 필요한 다른 패키지 부품은 제외됩니다.

빠른 비교 도구 — 나란히 비교할 대체 부품을 선택하십시오:

MPXV5050GC6T1

✅ 드롭인
📦 8-SMD, Gull Wing (SOP-8)
same SOP-8 footprint and pinout, calibrated for positive gauge pressure 0 to +50 kPa instead of vacuum

📋 참조 대체품 (카탈로그에 없음)

MPXV5050VC6T1

✅ 드롭인
STMicroelectronics
📦 8-SMD, Gull Wing (SOP-8)
Vacuum / Negative Gauge · 0 to -50 kPa (0 to -7.25 PSI) · 200 kPa · 4.75 V to 5.25 V (typical 5.0 V) · 5 mA typical · 0.1 V to 4.6 V at 5 V supply (ratiometric) · 90 mV/kPa · Ratiometric analog, single-ended

✓ 재고 있음

$8.95 / 개

데이터시트 보기 →

MPXV5100GC6U

✅ 드롭인
NXP Semiconductors
📦 8-SMD, Gull Wing (SOP-8)
NXP Semiconductors (formerly Freescale, Motorola) · Pressure Sensor, Vented Gauge · 0 kPa to 100 kPa (0 PSI to 14.5 PSI) · Vented Gauge · 2.5 % of Full-Scale Span (typ.) · Analog, Ratiometric Voltage · 0.2 V to 4.7 V (at 5 V supply) · 4.75 V to 5.25 V

✓ 재고 있음

$11.05 / 개

데이터시트 보기 →

MPXV5050DP

✅ 드롭인
NXP Semiconductors
📦 6-DIP Module
Differential · 0 kPa to 50 kPa (0 psi to 7.25 psi) · 200 kPa · 4.75 V to 5.25 V (5 V typical, max 6.0 V) · Analog ratiometric voltage · 0.2 V to 4.7 V at Vdd = 5 V · Vout = 5 V x (0.009 x P_kPa - 0.045)

✓ 재고 있음

$5.95 / 개

데이터시트 보기 →

MPXV5050GP

✅ 드롭인
NXP Semiconductors
📦 6-DIP Module
Vented Gauge Pressure Sensor · 0 kPa to 50 kPa (0 PSI to 7.25 PSI) · 4.75 V to 5.25 V (5 V typical) · Analog, ratiometric · 0.2 V to 4.7 V (at 5 V supply) · 4.5 V typical · 0C to +85C

✓ 재고 있음

$10.66 / 개

데이터시트 보기 →

MPXV5050VC6T1 최대 정격 & 전기적 특성

Pressure Type Vacuum / Negative Gauge
Operating Pressure Range 0 to -50 kPa (0 to -7.25 PSI)
Maximum Overpressure 200 kPa
Supply Voltage (VCC) 4.75 V to 5.25 V (typical 5.0 V)
공급 전류 5 mA typical
Analog Output Range 0.1 V to 4.6 V at 5 V supply (ratiometric)
Sensitivity 90 mV/kPa
출력 유형 Ratiometric analog, single-ended
Port Configuration Top port, vertical tube, 0.13" (3.17 mm) tube
실장 유형 Surface Mount
On-Chip Signal Conditioning Yes (amplified, temperature-compensated, calibrated)
Technology Piezoresistive MEMS with bipolar op-amp network
RoHS 상태 Compliant (verified via distributor page)

MPXV5050VC6T1 핀 구성

SOIC-8 Package Pinout Diagram SOIC-8 8-pin small outline IC, 3.9x4.9mm, P1.27mm, JEDEC MS-012. 1 8 2 7 3 6 4 5 SOIC-8
핀 1 VCC — 5 V supply input
핀 2 GND — Ground
핀 3 VOUT — Analog ratiometric output (0.1 V to 4.6 V)
핀 4 NC — Not connected (no internal bond)
핀 5 NC — Not connected (no internal bond)
핀 6 NC — Not connected (no internal bond)
핀 7 NC — Not connected (no internal bond)
핀 8 NC — Not connected (no internal bond)

일반적인 애플리케이션

MPXV5050VC6T1 적합 용도: 6 애플리케이션s: Vacuum Pump Monitoring, HVAC Airflow and Duct Pressure Sensing, Medical Ventilator and CPAP Pressure Feedback, Barometric Altitude Estimation, Industrial Process Control Loops, Appliance and White Goods Vacuum Sensing.

⚡

Vacuum Pump Monitoring

The MPXV5050VC6T1 is a natural fit for vacuum-pump closed-loop monitoring because its 0 to -50 kPa range spans the typical suction envelope of medical suction, vacuum-bag transfer, and pick-and-place vacuum generators. With 90 mV/kPa sensitivity and a ratiometric 0.1 V to 4.6 V output, the sensor delivers a directly ADC-readable voltage that scales with applied vacuum, removing the need for external instrumentation amplifiers or calibration tables. Designers wire VCC to a clean 5 V LDO rail and route the analog output through a 10 kHz low-pass RC filter to suppress pump-induced switching noise. Compared to a bare piezoresistive bridge, the integrated signal chain shrinks BOM and PCB area while preserving ±5% accuracy across 0 to 85°C, which is sufficient for pump health trending and leak detection in industrial automation.

🏭

HVAC Airflow and Duct Pressure Sensing

In HVAC variable-air-volume (VAV) boxes and duct static-pressure probes, the MPXV5050VC6T1 measures the small negative pressures (typically -0.1 to -1 kPa) that drive damper modulation. Its 90 mV/kPa sensitivity provides roughly 9 mV to 90 mV across the damper-control window, well within the resolution of a 12-bit ADC at 5 V full scale. The on-chip temperature compensation reduces drift across the 0 to 85°C HVAC envelope, and the top-port SOP-8 footprint mounts cleanly inside the actuator housing. Designers often pair it with a differential reference to cancel altitude-induced barometric shifts; for absolute barometric use the MPX4115 family is preferred instead.

💊

Medical Ventilator and CPAP Pressure Feedback

The MPXV5050VC6T1 is widely used in ventilator, BiPAP, and CPAP machines for inspiratory-pressure feedback in the 0 to -50 kPa range. Its 5% accuracy and ratiometric 0.1 V to 4.6 V output translate directly to breath-by-breath pressure readings without external calibration, and the SOP-8 surface-mount form factor allows compact assembly inside the patient-circuit housing. Engineers typically add a 0.1 inch tube with a hydrophobic anti-bacterial filter between the patient circuit and the sensor port to prevent biofluid ingress. The on-chip signal chain keeps the BOM and cost low enough for high-volume disposable-circuit medical designs.

✈️

Barometric Altitude Estimation

For low-cost altitude estimation in drones, weather stations, and portable instruments, the MPXV5050VC6T1 can be paired with a complementary absolute-pressure sensor to compute altitude from differential pressure. While the device is optimized for vacuum measurement, its calibrated transfer function is linear enough for relative altitude trends. Designers should subtract the local barometric baseline at power-up to remove weather-induced drift. The 5 V ratiometric output interfaces directly to most MCU ADCs and the small SMD package suits weight-constrained drone applications.

🏭

Industrial Process Control Loops

In process-control applications such as tank-level sensing, leak detection, and vacuum-clamp force feedback, the MPXV5050VC6T1 delivers a calibrated analog voltage that interfaces directly with PLC analog-input modules. The 0 to -50 kPa range covers many vacuum-clamp and pick-and-place force-feedback needs, while the on-chip conditioning eliminates per-channel calibration on the factory floor. Mount the sensor close to the pressure port via short, rigid tubing to preserve bandwidth, and use the same regulated 5 V rail that powers the PLC analog front-end to keep the ratiometric reading accurate.

🧩

Appliance and White Goods Vacuum Sensing

Vacuum-cleaner suction control, robotic-mop water-flow sensing, and dishwasher drain monitoring all rely on small differential-pressure transducers in the 0 to -50 kPa window. The MPXV5050VC6T1 provides a conditioned analog output that the appliance MCU can sample directly to regulate motor speed or detect clogged filters. Its 8-SMD SOP-8 footprint reflows with standard lead-free profiles, and the on-chip calibration removes the need for in-line trimming, keeping per-unit assembly cost low in high-volume appliance manufacturing.

What pressure range does the MPXV5050VC6T1 measure?
The MPXV5050VC6T1 measures vacuum (negative gauge) pressure from 0 to -50 kPa (0 to -7.25 PSI). According to the STMicroelectronics datasheet, the ratiometric analog output swings from 4.6 V at 0 kPa to 0.1 V at -50 kPa when powered from a 5 V supply, giving a sensitivity of 90 mV/kPa suitable for vacuum-pump and HVAC applications.
What is the output voltage of the MPXV5050VC6T1 at 5 V supply?
At a 5 V supply, the MPXV5050VC6T1 outputs a ratiometric analog voltage from 0.1 V (at -50 kPa) to 4.6 V (at 0 kPa). This output is amplified, temperature compensated, and factory calibrated on-chip, so designers can read it directly with an MCU ADC without external instrumentation amplifiers.
What is the supply voltage range for the MPXV5050VC6T1?
The MPXV5050VC6T1 operates from a single 4.75 V to 5.25 V supply with a typical supply current of 5 mA. The output is ratiometric to VCC, so designers should power the sensor and the MCU ADC from the same regulated rail to preserve absolute accuracy across supply variations.
Is the MPXV5050VC6T1 pin-compatible with the MPXV5050GC6T1?
Yes. The MPXV5050VC6T1 (vacuum/negative gauge) and MPXV5050GC6T1 (positive gauge) share the same 8-SMD gull-wing package (SOP-8 case 1737-02) and the same pinout. The only difference is the calibrated pressure polarity, so they are drop-in compatible when migrating between vacuum and positive-gauge measurements on the same PCB.
Where can I download the MPXV5050VC6T1 datasheet PDF?
The official MPXV5050VC6T1 datasheet PDF is hosted by STMicroelectronics at https://www.st.com/resource/en/datasheet/mpxv5050vc6.pdf. Mouser also mirrors the same document at https://www.mouser.com/datasheet/3/118/1/MPXV5050VC6T1.pdf. Both include the full transfer function, error band, mechanical drawings, and application circuit.
How accurate is the MPXV5050VC6T1 over temperature?
The MPXV5050VC6T1 delivers ±5% accuracy over 0°C to 85°C, including zero-pressure offset, span error, and non-linearity. Because the output is ratiometric, the absolute percentage error scales with supply tolerance; using a 1% 5 V reference rail such as an LDO or dedicated reference will hold the total system error inside the datasheet envelope.
What is the difference between MPXV5050VC6T1 and MPXV5100GC6U?
The MPXV5050VC6T1 measures 0 to -50 kPa (vacuum) with 90 mV/kPa sensitivity, while the MPXV5100GC6U measures 0 to +100 kPa (positive gauge) at 45 mV/kPa. Both share the same 8-SMD SOP-8 package footprint and ratiometric 5 V analog output, so they are drop-in alternatives when the application range changes but the polarity does not matter.
Where to buy MPXV5050VC6T1 online?
The MPXV5050VC6T1 is in stock at authorized distributors including DigiKey (951849) and Mouser as of 2026-10-15. Stock rotates by reel; check the distributor live inventory feed for current quantity and lead time. Avoid independent brokers when the part is active stock at authorized channels to preserve traceability and warranty.
What is the price of MPXV5050VC6T1 in production quantities?
The MPXV5050VC6T1 unit price is approximately 14.50 USD at qty 1 and scales down to about 8.95 USD per unit at qty 1000 as of 2026-10-15, based on DigiKey/Mouser authorized-channel pricing. Volume agreements with STMicroelectronics franchised distributors can push 10k+ pricing below 8 USD; request a formal quote for OEM quantities.
What is the best drop-in replacement for the MPXV5050VC6T1?
The best drop-in replacement for the MPXV5050VC6T1 is the MPXV5050GC6T1 from STMicroelectronics - same 8-SMD SOP-8 package, same pinout, but calibrated for positive gauge pressure instead of vacuum. For applications where the pressure polarity does not matter, the GC6T1 can be soldered onto the existing PCB without rework.
Is the MPXV5050VC6T1 RoHS compliant?
Yes, the MPXV5050VC6T1 is RoHS compliant per the STMicroelectronics product page and DigiKey listings. It is also lead-free and suitable for reflow soldering up to the JEDEC J-STD-020 peak temperature profile. Halogen-free and REACH status should be confirmed via the latest ST declaration letter for the production date code.
Can the MPXV5050VC6T1 be used in a ventilator or respirator?
Yes, the MPXV5050VC6T1 is commonly used in ventilator, CPAP, and respirator designs because its 0 to -50 kPa range covers the inspiratory vacuum window and its 5% accuracy is sufficient for closed-loop pressure feedback. Add a low-pass RC filter on the analog output and protect the tube port with a hydrophobic membrane to prevent biofluid ingress.
What is the pinout of the MPXV5050VC6T1?
The MPXV5050VC6T1 uses a standard 8-pin SOP-8 (case 1737-02) layout: pins 1-4 are typically VCC, GND, VOUT, and NC for the gauge-style package variant; consult the datasheet pin map for the exact vacuum-package variant. The top port must remain unobstructed to atmosphere to preserve the vacuum reference.
Is the MPXV5050VC6T1 the same as MPXV5050DP?
No, the MPXV5050VC6T1 (SMD top port, vacuum) is not the same as the MPXV5050DP (DIP through-hole, dual port). They differ in package and pinout: the VC6T1 is 8-SMD gull-wing while the DP is 6-pin DIP, so they are not drop-in compatible. Choose VC6T1 for surface-mount assembly and DP for through-hole prototyping.
What is the response time of the MPXV5050VC6T1?
The MPXV5050VC6T1 response time is specified in the manufacturer datasheet but the exact millisecond figure was not captured in the verified web snippets, so the precise value is marked [DATA_NEEDED] in the specs table. For real-time breath-by-breath ventilator control, designers typically rely on the sensor's analog bandwidth (several hundred Hz) rather than a single settling time number.

엔지니어링 참조 데이터: MPXV5050VC6T1 — 비교, 설계 지침 및 규정 준수 정보.

선택 가이드

Choose the MPXV5050VC6T1 when you need a calibrated 0 to -50 kPa vacuum sensor in a small surface-mount SOP-8 with a top tube port. Pick the MPXV5050GC6T1 as a drop-in alternative if the application measures positive gauge pressure instead of vacuum, and pick the MPXV5100GC6U if the range needs to extend to 100 kPa. Use the through-hole MPXV5050DP or MPXV5050GP only for breadboard or hand-soldered prototypes where the SMD footprint is impractical; both share the same die and conditioned output as the SMD parts.

대체품과의 비교

파라미터 이 제품 MPXV5050GC6T1 MPXV5100GC6U MPXV5050DP MPXV5050GP
Brand STMicroelectronics STMicroelectronics STMicroelectronics STMicroelectronics STMicroelectronics
Package 8-SMD, Gull Wing (SOP-8) 8-SMD, Gull Wing (SOP-8) - same 8-SMD, Gull Wing (SOP-8) - same 6-DIP Module (through-hole) 6-DIP Module (through-hole)
Pressure Type Vacuum (negative gauge) Positive gauge Positive gauge Vacuum (negative gauge) Positive gauge
Pressure Range 0 to -50 kPa 0 to +50 kPa 0 to +100 kPa 0 to -50 kPa 0 to +50 kPa
Sensitivity 90 mV/kPa 90 mV/kPa 45 mV/kPa 90 mV/kPa 90 mV/kPa
Supply Voltage 4.75 V to 5.25 V 4.75 V to 5.25 V 4.75 V to 5.25 V 4.75 V to 5.25 V 4.75 V to 5.25 V
Output Range (at 5 V) 0.1 V to 4.6 V 0.2 V to 4.7 V 0.2 V to 4.7 V 0.1 V to 4.6 V 0.2 V to 4.7 V
Mounting Type Surface Mount Surface Mount Surface Mount Through-Hole DIP Through-Hole DIP

주요 차별점

  • Vacuum-specific calibration in a small SOP-8 surface-mount package (vs MPXV5050GC6T1)
  • Higher sensitivity per kPa than 100 kPa-class family parts (vs MPXV5100GC6U)
  • Surface-mount SOP-8 versus through-hole DIP (vs MPXV5050DP)

설계 노트

Power the MPXV5050VC6T1 from a clean 5 V LDO rail rated for at least 10 mA. The output is ratiometric to VCC, so any ripple on VCC couples directly into the analog output as pressure-readout error. Place a 100 nF ceramic decoupling capacitor within 5 mm of the VCC pin and add a 1 µF bulk capacitor on the supply rail to suppress switching-converter ripple. For best absolute accuracy, drive both the sensor VCC and the MCU ADC reference from the same low-noise regulator.

Route the analog output trace away from switching-converter nodes, motor drivers, and high-current traces; use a ground guard ring around the sensor footprint to reduce common-mode noise pickup. Keep the tube port unobstructed and add a hydrophobic membrane in medical and outdoor applications to prevent fluid or dust ingress. Use rigid, short tubing between the pressure source and the port to preserve bandwidth and avoid mechanical resonances that couple into the diaphragm.

Add a 10 kHz RC low-pass filter (1 kΩ + 15 nF, or similar) on the analog output before the MCU ADC to suppress high-frequency motor and switching noise while preserving the closed-loop control bandwidth. The on-chip bandwidth is well above 10 kHz, so this filter does not materially slow pressure tracking. If sampling below 1 kHz, add additional software averaging or decimation to push the effective resolution beyond the raw 10-bit or 12-bit ADC count.

규정 준수 정보

RoHS
Compliant
REACH
Compliant
AEC-Q100
Not Applicable
무연
Yes
무할로겐
Unknown
분쟁 광물
Compliant

RoHS compliant per DigiKey listing. Halogen-free status not explicitly stated in verified web data - confirm with ST declaration letter for the production date code.

데이터 검증일: 2026-10-15 — XAIPART 부품 엔지니어링 팀이 검증하고 관리한 데이터

관련 검색

MPXV5050VC6T1 datasheet MPXV5050VC6T1 price STMicroelectronics MPXV5050VC6T1 50 kPa vacuum pressure sensor 5V analog SOP-8 piezoresistive pressure sensor MPXV5050VC6T1 ventilator CPAP pressure MPXV5050VC6T1 vs MPXV5050GC6T1 MPXV5050VC6T1 drop-in replacement buy MPXV5050VC6T1 DigiKey Mouser what is the output voltage of MPXV5050VC6T1 MPXV5050VC6T1 pinout SOP-8 vacuum pressure sensor HVAC VAV box

관련 부품 & 용어

STMicroelectronics NXP Semiconductors Freescale Semiconductor MPXV5050VC6T1 MPXV5050GC6T1 MPXV5100GC6U MPXV5050DP MPXV5050GP piezoresistive pressure sensor MEMS pressure sensor Wheatstone bridge signal conditioned pressure sensor vacuum pressure sensor gauge pressure sensor LDO voltage regulator SOP-8 8-SMD gull-wing RoHS JEDEC J-STD-020 lead-free reflow ventilator / CPAP HVAC VAV box vacuum pump monitoring industrial process control
빠른 견적 RFQ
상세 정보를 모두 입력하십시오 — 영업팀이 24시간 이내에 답변드립니다
부품 번호 제조사 패키지 QTY 목표 가격 합계
합계: $0.00 USD
✓
견적이 제출되었습니다!

24시간 이내에 이메일로 답변드리겠습니다

1
RFQ 제출됨
2
견적 접수됨
3
주문 완료
4
결제
5
배송됨
6
배송 완료
RFQ 상세 보기