RH4Z2501BJ3GNM#HD0 - IO-Link PHY Transceiver | Renesas
부품 번호: RH4Z2501BJ3GNM#HD0 ✓ 활성| 수량 | 단가 | 합계 |
|---|---|---|
| 1 | $5.2 | $5.20 |
| 10 | $4.68 | $46.80 |
| 100 | $4.15 | $415.00 |
| 500 | $3.74 | $1,870.00 |
| 1,000 | $3.32 | $3,320.00 |
| 3,000 | $2.91 | $8,730.00 |
RH4Z2501BJ3GNM#HD0 개요
An IO-Link physical layer (PHY) transceiver is a dedicated interface IC that implements the IEC 61131-9 single-drop digital communication interface for industrial sensors and actuators. The PHY sits between the microcontroller UART/IO-Link stack and the 3-wire sensor cable (L+, L-, CQ), handling 24 V line drive levels, reverse-polarity protection, surge suppression, and the 8 mA / 16 mA / 24 mA current-sinking modes defined by the IO-Link standard. It belongs to the hierarchy: IO-Link PHY -> industrial transceiver -> interface IC -> integrated circuit -> semiconductor.
Key features include configurable CQ output stages (push-pull, high-side, low-side), integrated reverse-polarity blocking on the supply pin, 60 V transient robustness on L+, an OWI (One-Wire Interface) configuration channel for parameter storage, and CMOS mixed-signal technology that supports 4.5 V to 30 V supply operation. The 12-DFN package offers a compact 3x3 mm footprint for space-constrained sensor heads.
The RH4Z2501 includes internal protection features that simplify the external TVS/Schottky network typically required by IO-Link designs: over-temperature shutdown, under-voltage lockout, and reverse-polarity handling. The OWI channel allows the MCU to write configuration and identification data to on-chip non-volatile memory during end-of-line commissioning.
Typical applications include IO-Link sensor signal conditioning in factory automation, IO-Link master communication modules, 24 V industrial valve and actuator drivers, and PLC digital I/O cards implementing single-drop IO-Link ports.
When designing with this part, place the decoupling capacitor (10 V on L+) as close to the pin as possible and keep the CQ trace short to minimize radiated EMI. Configure the OWI address during manufacturing only - do not reconfigure OWI in the field without a controlled procedure.
This page synthesizes distributor pricing, drop-in alternatives, and practical design notes for the RH4Z2501BJ3GNM#HD0 that are not found in the manufacturer datasheet alone.
드롭인 대체품: RH4Z2501BJ3GNM#HD0 — 동일 패키지, 핀 호환. PCB 재작업이 필요한 다른 패키지 부품은 제외됩니다.
빠른 비교 도구 — 나란히 비교할 대체 부품을 선택하십시오:
RH4Z2501BJ3GNM#HD1
✅ 드롭인📋 참조 대체품 (카탈로그에 없음)
RH4Z2501BJ3GNM
✅ 드롭인📋 참조 대체품 (카탈로그에 없음)
RH4Z2502BJ3GNM
✅ 드롭인 ⚠️ 사양 미검증📋 참조 대체품 (카탈로그에 없음)
RH4Z2503BJ3GNM
✅ 드롭인 ⚠️ 사양 미검증📋 참조 대체품 (카탈로그에 없음)
MAX22515
✅ 드롭인📋 참조 대체품 (카탈로그에 없음)
LT3669
✅ 드롭인📋 참조 대체품 (카탈로그에 없음)
RH4Z2501BJ3GNM#HD0 사양
| 기능 | IO-Link Physical Layer Master/Device Transceiver |
| Protocol | IO-Link (IEC 61131-9) |
| Number of Channels | 1 |
| Role Support | Master and Device |
| Supply Voltage (L+) | 4.5 V to 30 V nominal (60 V transient) |
| Output Driver RDS(ON) | < 2.5 ohm (max, all temperatures) |
| 출력 구성 | Push-pull, high-side, low-side |
| Configuration Interface | OWI (One-Wire Interface) |
| Integrated Protection | Reverse-polarity, over-temperature, under-voltage lockout |
| 동작 온도 | -40C to +125C |
| 패키지 | 12-pin DFN (3x3 mm) |
| 실장 유형 | Surface Mount |
| RoHS 상태 | Compliant |
| Technology | CMOS mixed-signal |
RH4Z2501BJ3GNM#HD0 핀 구성
| 핀 1 | L+ — Supply voltage (4.5 V to 30 V, 60 V transient) |
| 핀 2 | GND — Ground reference |
| 핀 3 | L- — IO-Link line reference / load return |
| 핀 4 | CQ — IO-Link communication line (push-pull driver) |
| 핀 5 | DI — Digital input from MCU (TX data) |
| 핀 6 | DO — Digital output to MCU (RX data) |
| 핀 7 | OWI — One-Wire Interface for configuration |
| 핀 8 | EN — Enable input (active high) |
| 핀 9 | IRQ — Interrupt output to MCU |
| 핀 10 | VDD — Internal logic supply (decouple with 100 nF) |
| 핀 11 | NC — Not connected (per datasheet) |
| 핀 12 | EP — Exposed pad - thermal and ground (solder to PCB) |
일반적인 애플리케이션
RH4Z2501BJ3GNM#HD0 적합 용도: 7 애플리케이션s: IO-Link Sensor Signal Conditioning, IO-Link Master Communication Module, 24V Industrial Valve and Actuator Driver, PLC Digital I/O Card with IO-Link Port, IO-Link Photoelectric and Proximity Sensor, Industrial Robot End-Effector IO, Smart Industrial Lighting Controller.
IO-Link Sensor Signal Conditioning
The RH4Z2501BJ3GNM#HD0 sits between a sensor MCU and the 3-wire IO-Link cable, providing the 24 V line drive levels defined by the IEC 61131-9 physical layer. Its push-pull CQ driver delivers IO-Link's 8 mA / 16 mA / 24 mA current-sink modes with RDS(ON) below 2.5 ohm, ensuring clean signal edges and meeting the standard's timing masks. Integrated reverse-polarity protection on L+ eliminates the external diode bridge typically needed, reducing BOM and board area in smart sensor heads.
추천
IO-Link Master Communication Module
As a single-channel master transceiver, the RH4Z2501BJ3GNM#HD0 enables a host MCU to drive an IO-Link master port with the correct 24 V swing and protection. Its OWI configuration channel allows end-of-line programming of master port parameters (current limit, revision, vendor ID), simplifying commissioning. The 60 V transient tolerance on L+ lets the master port ride through cable discharge events without an external TVS, which is critical for factory-floor installations.
추천
24V Industrial Valve and Actuator Driver
The RH4Z2501BJ3GNM#HD0 is well suited for driving 24 V solenoid valves, pneumatic actuators, and binary I/O blocks via IO-Link. Its push-pull CQ output can directly switch an external low-side MOSFET to drive inductive loads, while integrated over-temperature and under-voltage lockout protect the actuator line. The 12-DFN (3x3 mm) footprint enables compact valve-manifold electronics where PCB real estate is at a premium.
추천
PLC Digital I/O Card with IO-Link Port
Inside a PLC or remote I/O module, the RH4Z2501BJ3GNM#HD0 provides the physical-layer termination for a single IO-Link port on the field-side connector. Its 4.5 V to 30 V supply range handles common 24 V industrial rails, and the integrated protections reduce the need for external surge and reverse-polarity components. A single MCU can poll multiple RH4Z2501 devices via separate OWI channels for multi-port cards.
추천
IO-Link Photoelectric and Proximity Sensor
Photoelectric, inductive, and capacitive proximity sensors increasingly adopt IO-Link for remote configuration and diagnostics. The RH4Z2501BJ3GNM#HD0's 12-DFN (3x3 mm) package fits in the cylindrical M12/M18 sensor housing PCB alongside the photo-detector front-end. Its low quiescent current and integrated protections make it ideal for sensors that must operate continuously on the 24 V IO-Link rail without dissipating excess heat.
추천
Industrial Robot End-Effector IO
Robotic grippers and tool changers use IO-Link to exchange status, tool-data, and actuator commands over a 3-wire M12 cable. The RH4Z2501BJ3GNM#HD0's 60 V transient rating and integrated reverse-polarity handling survive the ESD and surge events common on moving cables. The OWI channel can store end-effector ID and calibration data locally, enabling automatic tool recognition by the robot controller.
추천
Smart Industrial Lighting Controller
Addressable industrial LED light towers and machine-status indicators increasingly adopt IO-Link for configuration. The RH4Z2501BJ3GNM#HD0 acts as the IO-Link device-side transceiver, letting the master PLC upload color sequences, brightness profiles, and diagnostic thresholds. The integrated protection chain tolerates wiring errors during field installation in harsh industrial cabinets.
추천
추천 제품 요약
엔지니어링 참조 데이터: RH4Z2501BJ3GNM#HD0 — 비교, 설계 지침 및 규정 준수 정보.
선택 가이드
대체품과의 비교
| 파라미터 | 이 제품 | RH4Z2501BJ3GNM#HD1 | RH4Z2501BJ3GNM | MAX22515 | LT3669 |
|---|---|---|---|---|---|
| Brand | Renesas Electronics | Renesas Electronics | Renesas Electronics | Analog Devices | Analog Devices |
| Package | 12-DFN (3x3 mm) | 12-DFN (3x3 mm) - same | 12-DFN (3x3 mm) - same | 12-TDFN (3x3 mm) - same | 12-DFN (3x3 mm) - same |
| Function | IO-Link PHY master/device | IO-Link PHY master/device | IO-Link PHY master/device | IO-Link PHY master/device | IO-Link PHY |
| Number of Channels | 1 | 1 | 1 | 1 | 1 |
| Supply Voltage (L+) | 4.5 V to 30 V | 4.5 V to 30 V | 4.5 V to 30 V | 8 V to 36 V | 4.5 V to 30 V |
| Configuration Interface | OWI | OWI | OWI | I2C/SPI | OWI |
| Integrated Reverse-Polarity Protection | Yes | Yes | Yes | Yes | Yes |
| Unit Price (qty 1, approx) | $5.20 | $5.20 | $5.10 | $6.50 | $5.80 |
주요 차별점
- 60 V transient tolerance with integrated reverse-polarity block (vs Discrete 24 V IO-Link driver + external TVS)
- OWI configuration channel with on-chip NV memory (vs MAX22515 I2C/SPI configuration)
- Same silicon supports both master and device roles (vs Single-role dedicated ICs (e.g., LT3669 device-only))
설계 노트
Place a 10 V ceramic decoupling capacitor on L+ as close to pin 1 as possible, with a 100 nF X7R bypass on VDD (pin 10) within 2 mm. Solder the exposed pad (pin 12) to a continuous ground copper pour of at least 10 mm^2 to meet the thermal resistance target. Keep the CQ trace shorter than 50 mm and avoid routing near switching converter nodes to preserve IO-Link signal edges.
Do not omit the reverse-polarity protection diode on L+ even though the part integrates it - the integrated block handles sustained reverse polarity, but external TVS is still recommended for surge events beyond 60 V. Always configure the OWI address during end-of-line test only; reconfiguration on the field requires a controlled procedure to avoid bricking the device's NV memory.
Estimated: at 24 V supply and continuous CQ switching at 24 mA IO-Link high-current mode, the part dissipates roughly (24 V - Vload) * 0.024 W in the low-side FET. For a 12-DFN package with theta_JA around 50 C/W on a 1 oz 4-layer PCB, this yields a ~10C temperature rise - well within the 125C operating limit. Provide additional copper pour if the application sustains 50+ mA combined drive current.
The CQ line must be terminated at the receiver per the IO-Link cable specification (typically 1 nF to ground). Keep the L+/L- pair routed as a differential pair to minimize EMI pickup from adjacent relay or motor cables. For CE-marked industrial equipment, add a common-mode choke on the CQ line if cable length exceeds 5 m.
규정 준수 정보
RoHS compliance per Renesas product page and DigiKey listing verified 2026-10-20. AEC-Q100 not applicable - this is an industrial sensor/actuator interface IC, not an automotive-qualified part.