LTC486ISW - Quad RS485 Driver, 5V, 16-SOIC | Analog Devices
MPN: LTC486ISW ✓ ActiveLTC486ISW Overview
An RS485 driver is a physical-layer interface component that converts a digital logic signal into a balanced differential signal suitable for reliable communication over long or electrically noisy cables. It belongs to the interface IC hierarchy, alongside RS422 line drivers, transceivers, and isolators. Balanced differential signaling improves common-mode noise rejection and enables multiple devices to share a bus when their outputs are tri-stated.
The LTC486 uses a low-power CMOS implementation with a typical supply current of 110 µA. It meets RS485 and RS422 applications, supports extended common-mode operation, and provides three-state outputs for multipoint networks. Its ruggedness against overload and electrostatic-discharge damage makes it suitable for industrial equipment where driver outputs may encounter noisy or fault-prone bus wiring.
The four independent channels reduce the component count on systems that require multiple communication links, instrumentation buses, or distributed I/O. Thermal shutdown protects the device if an output is accidentally shorted to a supply or low-impedance source. Depending on the fault condition, the manufacturer notes that up to 250 mA can flow through the affected output before shutdown behavior intervenes.
Typical uses include industrial measurement systems, instrumentation buses, data acquisition equipment, factory automation interfaces, and embedded control systems. The LTC486 is especially useful where multiple nodes must share one bus and only one transmitter should be active at a time. Its extended common-mode range can improve interoperability in systems using longer cables or grounds at different potentials.
PCB design should keep the driver close to the bus connector, provide a solid ground-plane connection, and include appropriate protection against external transients. Verify output rise and fall times, bus loading, cable length, termination, and grounding before treating a laboratory connection as production-ready. The 16-pin SOIC also leaves adequate board area for routing and surge-protection components.
This product page combines the LTC486 family specifications with orderable package information, focused application guidance, design checks, and verified same-footprint alternatives. It helps engineers distinguish the basic LTC486ISW ordering code from lead-free and tape-and-reel production variants without overlooking common-mode, thermal, and bus-integration constraints.
Drop-in alternatives for LTC486ISW — same package, pin-to-pin compatible. Different-package parts requiring PCB rework are excluded.
LTC486ISW#PBF
✅ Drop-In📋 Reference alternative (not in catalog)
LTC486ISW Specifications
| Device Type | Quad differential bus/line driver |
| Supported Standards | RS485 and RS422 |
| Number of Drivers | 4 channels |
| Supply Voltage | 5 V |
| Typical Supply Current | 110 µA |
| Common-Mode Range | -7 V to +12 V |
| Output State Control | Three-state outputs |
| Technology | CMOS |
| Operating Temperature | -40 °C to +85 °C |
| Package | 16-pin SOIC (SOL-16) |
| Pin Count | 16 pins |
| Mounting Type | Surface mount |
| Thermal Shutdown Temperature | 150 °C |
| Maximum Fault Current per Output | Up to 250 mA |
| Overload and ESD Ruggedness | Designed for overload and ESD damage resistance |
LTC486ISW 16-pin soic (sol-16) Pin Configuration Guide
Pin configuration for LTC486ISW (16-pin soic (sol-16) package). Pin numbering, functions, and connection diagrams are defined in the manufacturer datasheet. Refer to it for the exact footprint and soldering guidelines.
No detailed pinout data available for LTC486ISW.
Refer to the datasheet for full pin configuration.
Typical Applications
LTC486ISW is suitable for 6 applications: Industrial Instrumentation Bus, Data Acquisition Equipment, Factory Automation Control, Building and HVAC Networks, Remote Sensor Interface, Embedded Communication Gateway.
Industrial Instrumentation Bus
The LTC486ISW fits industrial instrumentation buses that require multiple differential driver channels from one 5 V interface circuit. Its four channels can connect separate nodes to a shared RS485 pair, while three-state control prevents simultaneous active drivers from fighting each other. The manufacturer-rated -7 V to +12 V common-mode range provides additional tolerance for ground-potential differences across a multi-node installation. With a typical supply current of 110 µA, the device also suits distributed field equipment where long idle periods make supply efficiency important. The design should still include connector-level surge protection, controlled grounding, and logic timing that disables all but the intended bus transmitter.
Recommended
Data Acquisition Equipment
The LTC486ISW is suitable for laboratory and process data-acquisition equipment that must place control or measurement information onto an RS485 or RS422 network. Four differential driver channels allow one package to support several bus segments, reducing board area compared with separate single-channel drivers. The 5 V supply operation integrates naturally with modern mixed-signal equipment, while the CMOS implementation provides a typical supply current of 110 µA. For reliable acquisition systems, use separate driver and receiver circuitry where full duplex is required, and verify that each cable, terminator, and grounding arrangement is compatible with the intended RS485 topology.
Recommended
Factory Automation Control
The LTC486ISW supports factory automation interfaces where controllers, sensors, remote I/O modules, and operator panels communicate over a multipoint bus. Four independently enabled channels can serve multiple cable ports or support bus segmentation, and the three-state outputs allow inactive channels to release the bus. Its -40 °C to +85 °C operating range covers industrial environments, while overload resistance and thermal shutdown help manage accidental output faults. A production design should add appropriate transient protection at exposed connectors because the IC's internal ruggedness does not determine the surge withstand rating of the complete interface path.
Recommended
Building and HVAC Networks
The LTC486ISW can be used in building-control and HVAC equipment for reliable communication with distributed sensors, actuators, and supervisory controllers. RS485 differential signaling suits longer cable runs and installations where electrical noise is present, while the extended common-mode range helps accommodate potential differences between powered nodes. Four channels provide flexibility when a controller must communicate with several bus segments or isolated device groups. Because HVAC equipment may experience temperature changes and wiring faults, maintain the specified -40 °C to +85 °C range and use thermal shutdown as a secondary protection layer rather than the sole safeguard against a shorted bus.
Recommended
Remote Sensor Interface
The LTC486ISW is appropriate for remote sensor interfaces that transmit commands or collected information over an RS485 network. Its low typical supply current of 110 µA helps limit consumption in remotely powered or duty-cycled equipment, and the three-state outputs support multiple nodes attached to the same bus when only one is transmitting. The -7 V to +12 V common-mode capability offers useful margin where the sensor ground and controller ground are not identical. Engineering validation should include cable-length and capacitance checks, termination at the physical ends of the bus, and verification that the chosen protection components preserve the driver's intended signaling behavior.
Recommended
Embedded Communication Gateway
The LTC486ISW suits embedded gateways that bridge processor-based systems to legacy RS485 or RS422 equipment. Four driver channels can support multiple external buses without allocating a separate package for every port, and operation from a single 5 V rail simplifies integration with digital controllers. The low-power CMOS design is particularly helpful in compact gateways where standby consumption matters. Layout should keep the SOIC close to the external connector, route differential outputs as a tightly coupled pair, and provide a direct return-path connection to the connector ground. Firmware must also enforce exclusive bus enable timing so that two nodes cannot drive the network simultaneously.
Recommended
Recommended Products Summary
Engineering reference data for LTC486ISW — comparison, design guidance, and compliance information.
Selection Guide
Comparison with Alternatives
| Parameter | This Product | LTC486ISW#PBF |
|---|---|---|
| Brand | Analog Devices | Analog Devices |
| Package | SOIC-16 (SOL-16) | SOIC-16 (SOL-16), same footprint |
| Device Type | Quad differential bus/line driver | Quad differential bus/line driver |
| Supported Standards | RS485 and RS422 | RS485 and RS422 |
| Number of Drivers | 4 channels | 4 channels |
| Supply Voltage | 5 V | 5 V |
| Typical Supply Current | 110 µA | 110 µA |
| Common-Mode Range | -7 V to +12 V | -7 V to +12 V |
| Output Control | Three-state outputs | Three-state outputs |
| Operating Temperature | -40 °C to +85 °C | -40 °C to +85 °C |
Key Differentiators
- Four-channel differential driver integration (vs A single-channel RS485 driver)
- Extended RS485 common-mode range (vs A conventional limited common-mode RS485 driver)
- Low-power CMOS implementation (vs A typical bipolar RS485 line driver)
Design Notes
Route each differential driver output as a tightly coupled pair from the LTC486ISW to the connector. Keep the pair geometry consistent and avoid splitting its return path, because mismatched impedances can degrade signal integrity and increase radiated emissions. Place the IC near the connector and place protection devices close to the entry point. Maintain a continuous ground reference beneath the interface area and avoid sharing narrow return-current paths with high-current switching stages.
Do not enable more than one driver on the same RS485 bus segment at a time. The LTC486ISW provides three-state outputs for multipoint communication, but the firmware or hardware control logic must prevent overlapping enable intervals. Review propagation delay and enable timing from the manufacturer datasheet, include suitable holding time around disable, and test every power-up, reset, and fault-recovery sequence for bus contention.
Calculate the worst-case driver dissipation rather than relying only on the 110 µA typical supply current. A shorted output can draw up to 250 mA according to the Analog Devices LTC486 manufacturer datasheet, and thermal shutdown engages at 150 °C. Use the datasheet electrical limits for worst-case design calculations, provide connector protection where necessary, and ensure that the exposed copper and surrounding airflow can dissipate normal switching and fault-related heat.
Confirm the complete orderable suffix before releasing production documents. LTC486ISW, LTC486ISW#PBF, and LTC486ISW#TR identify different purchasing or packaging conditions for the LTC486 family. Use the manufacturer ordering guide to confirm temperature grade, lead-free status, shipping format, and quantity limits. A component marked with a functionally similar family name is not automatically approved for substitution without a complete electrical, timing, pinout, and footprint review.
Compliance Information
The verified product information identifies LTC486ISW#PBF as a lead-free ordering designation, but the manufacturer pages do not explicitly state the compliance status of the base LTC486ISW ordering code. RoHS, REACH, AEC-Q100, halogen-free, and conflict-minerals status therefore remain unconfirmed.