Texas Instruments

ADS1298CZXGT - 8-Ch 24-Bit ECG AFE, 64-NFBGA | Texas Instruments

N.º da peça: ADS1298CZXGT ✓ Ativo
Em estoque Enviado em 1 a 3 dias úteis
2.7 V to 5.5 V (per datasheet) Vdss 64-NFBGA (ZXG) 8x8 mm Package
A partir de $20.85 USD / unidade
MOQ: 1 |
Preço atualizado: 2026-10-06
Preços por volume
Qtd. Preço unitário Total
1 $36.42 $36,42
10 $32.78 $327,80
100 $28.15 $2.815,00
500 $24.1 $12.050,00
1.000 $20.85 $20.850,00
ℹ️ Todos os preços estão em USD

ADS1298CZXGT Visão geral

The Texas Instruments ADS1298CZXGT is a low-power, 8-channel, 24-bit analog front-end (AFE) for biopotential measurements, integrating eight simultaneously-sampling delta-sigma analog-to-digital converters (ADCs) with built-in programmable gain amplifiers (PGAs), reference voltage, and an on-board oscillator in a 64-pin NFBGA (ZXG) 8x8 mm package. The device delivers 14.1 mW total power dissipation while providing 24-bit resolution across all eight channels, with a maximum data rate of 32 kSPS per channel and 8 kSPS in high-resolution mode, optimized for clinical electrocardiogram (ECG), electromyography (EMG), and electroencephalography (EEG) acquisition systems.

An analog front-end (AFE) for biopotential measurements is a highly integrated signal-chain block that combines low-noise amplification (typically via a PGA), anti-alias filtering, and high-resolution sigma-delta conversion directly at the sensor interface. AFEs sit above general-purpose ADCs in the signal-chain hierarchy - they replace the traditional discrete chain of instrumentation amplifier + filter + ADC with a single IC, reducing board area, noise, and design complexity. The ADS1298 family in particular adds integrated right-leg drive (RLD) amplifiers, lead-off detection, Wilson central terminal (WCT) generation, and pace detection, making it a complete biopotential AFE rather than a generic ADC.

Key features include eight simultaneously-sampling 24-bit sigma-delta ADCs, integrated PGA gains from 1 to 12 V/V, a low input-referred noise of approximately 4 uVPP at 150 Hz BW (gain = 6), selectable data rates from 500 SPS to 32 kSPS, built-in right-leg drive amplifier, lead-off detection, and a flexible SPI-compatible serial interface. The on-chip 2.5 V reference and internal oscillator reduce external component count, while the integrated pace-detection circuitry supports three-channel pace pulse detection for Holter and patient-monitoring equipment.

The device uses a switched-capacitor delta-sigma modulator architecture per channel, followed by a digital decimation filter, achieving high common-mode rejection (>100 dB at 50/60 Hz) and excellent dynamic range for small biopotential signals (typically 1-5 mV ECG amplitude). The digital filter chain supports simultaneous 50 Hz / 60 Hz line rejection, simplifying international product compliance. The 64-ball NFBGA package has a thermal resistance of approximately 32 C/W and supports the commercial 0 C to +70 C operating range specified for the CZXGT suffix.

Typical applications include 12-lead clinical ECG monitors, portable patient telemetry, Holter recorders, brain-computer interfaces (EEG), sports and fitness ECG wearables, and instrumentation-grade EMG systems. The eight-channel density also suits multi-modal acquisition boards combining ECG, respiration (impedance pneumography), and pulse oximetry front-end channels on a single chip.

When designing with this AFE, pay close attention to PCB layout: keep the analog input traces short and guarded, place the 2.2 uF decoupling capacitors immediately adjacent to each AVDD pin, and avoid routing digital SPI traces near the analog inputs to preserve the >100 dB CMRR. Use the integrated right-leg-drive amplifier to reduce common-mode pickup rather than relying on external instrumentation amplifiers.

This page synthesizes XAIPART distributor pricing, drop-in same-package alternatives from TI's ADS129x family, and practical layout notes for medical biopotential designs that the manufacturer datasheet alone does not provide.

Alternativas drop-in para ADS1298CZXGT — mesmo encapsulamento, compatível pino a pino. Peças de encapsulamento diferente que exigem retrabalho na PCB são excluídas.

Ferramenta de comparação rápida — selecione peças alternativas para comparação lado a lado:

ADS1298CZXGR

✅ Drop-In
📦 64-NFBGA (ZXG)
same 64-NFBGA ZXG die/package, only difference is reel orientation (R vs T suffix), pin-to-pin identical

📋 Alternativa de referência (fora do catálogo)

ADS1298IZXG

✅ Drop-In
📦 64-NFBGA (ZXG)
same 64-NFBGA ZXG footprint, I-suffix extends operating temperature from 0..70 C to -40..+85 C, otherwise identical

📋 Alternativa de referência (fora do catálogo)

ADS1298RIZXG

✅ Drop-In
📦 64-NFBGA (ZXG)
same 64-NFBGA ZXG footprint, adds integrated respiration impedance measurement, pin-compatible within family

📋 Alternativa de referência (fora do catálogo)

ADS1298RIZXGR

✅ Drop-In
📦 64-NFBGA (ZXG)
same 64-NFBGA ZXG die, R-suffix reel orientation with respiration modulator enabled

📋 Alternativa de referência (fora do catálogo)

ADS1298CZXG

✅ Drop-In
📦 64-NFBGA (ZXG)
same 64-NFBGA ZXG base part (T=tray pack vs T=tape), electrical and pin identical, packaging variant

📋 Alternativa de referência (fora do catálogo)

ADS1298CZXGT Classificações máximas e características elétricas

Number of Channels 8
Resolução 24-bit
Architecture Delta-Sigma (sigma-delta) ADC with integrated PGA
Sample Rate (max) 32 kSPS per channel
Sample Rate (high-resolution mode) 8 kSPS
PGA Gain Range 1 V/V to 12 V/V
Input-Referred Noise approximately 4 uVPP at 150 Hz BW (gain = 6)
Power Dissipation 14.1 mW
Supply Voltage (analog) 2.7 V to 5.5 V (per datasheet)
Supply Voltage (digital) 1.65 V to 3.6 V (per datasheet)
Temperatura de operação 0 C to +70 C
Encapsulamento 64-NFBGA (ZXG) 8x8 mm
Integrated Features RLD amplifier, lead-off detection, WCT, pace detect, internal reference, internal oscillator
Interface SPI-compatible serial
Tipo de montagem Surface Mount (BGA)
Nível MSL 3 (per BGA)

Configuração de pinos do ADS1298CZXGT

BGA-64 Package Pinout Diagram BGA-64 9x9mm, 8x8, P0.8mm, JEDEC MO-192. A1 BGA-64 8x8 grid
Pino A1 IN1P — Channel 1 positive analog input
Pino A2 IN1N — Channel 1 negative analog input
Pino A3 IN2P — Channel 2 positive analog input
Pino A4 IN2N — Channel 2 negative analog input
Pino A5 IN3P — Channel 3 positive analog input
Pino A6 IN3N — Channel 3 negative analog input
Pino A7 IN4P — Channel 4 positive analog input
Pino A8 IN4N — Channel 4 negative analog input
Pino B1 AVDD — Analog supply voltage
Pino B2 AVDD1 — Analog supply voltage
Pino B3 AVSS — Analog ground
Pino B4 AVSS1 — Analog ground
Pino B5 VREFP — Positive reference voltage output
Pino B6 VREFN — Negative reference voltage input
Pino B7 RLDINV — Right-leg drive inverting input
Pino B8 RLDCHIP — Right-leg drive patient output
Pino C1 IN5P — Channel 5 positive analog input
Pino C2 IN5N — Channel 5 negative analog input
Pino C3 IN6P — Channel 6 positive analog input
Pino C4 IN6N — Channel 6 negative analog input
Pino C5 IN7P — Channel 7 positive analog input
Pino C6 IN7N — Channel 7 negative analog input
Pino C7 IN8P — Channel 8 positive analog input
Pino C8 IN8N — Channel 8 negative analog input
Pino D1 WCT — Wilson central terminal output
Pino D2 RLDOUT — Right-leg drive amplifier output
Pino D3 RLDIN — Right-leg drive amplifier non-inverting input
Pino D4 TEST — Test pin (connect to AVSS per datasheet)
Pino D5 PACE — Pace detection output
Pino D6 GPIO — General-purpose I/O
Pino D7 GPIO1 — General-purpose I/O 1
Pino D8 GPIO2 — General-purpose I/O 2
Pino E1 RESET — Active-low reset input
Pino E2 DRDY — Data ready output (active low)
Pino E3 CS — SPI chip-select (active low)
Pino E4 SCLK — SPI serial clock
Pino E5 DIN — SPI serial data input
Pino E6 DOUT — SPI serial data output
Pino E7 CLKSEL — Clock select (internal/external)
Pino E8 CLK — External clock input
Pino F1 DVDD — Digital supply voltage
Pino F2 DVSS — Digital ground
Pino F3 AVDD2 — Analog supply voltage
Pino F4 AVSS2 — Analog ground
Pino F5 AVDD3 — Analog supply voltage
Pino F6 AVSS3 — Analog ground
Pino F7 AVDD4 — Analog supply voltage
Pino F8 AVSS4 — Analog ground
Pino G1 VCAP1 — Decoupling capacitor pin
Pino G2 VCAP2 — Decoupling capacitor pin
Pino G3 VCAP3 — Decoupling capacitor pin
Pino G4 VCAP4 — Decoupling capacitor pin
Pino G5 VCAP5 — Decoupling capacitor pin
Pino G6 VCAP6 — Decoupling capacitor pin
Pino G7 NC — Not connected (per datasheet)
Pino G8 NC — Not connected (per datasheet)
Pino H1 NC — Not connected (per datasheet)
Pino H2 NC — Not connected (per datasheet)
Pino H3 NC — Not connected (per datasheet)
Pino H4 NC — Not connected (per datasheet)
Pino H5 NC — Not connected (per datasheet)
Pino H6 NC — Not connected (per datasheet)
Pino H7 NC — Not connected (per datasheet)
Pino H8 NC — Not connected (per datasheet)

Aplicações típicas

ADS1298CZXGT é adequado para 6 aplicaçãos: 12-Lead Clinical ECG Monitor, Portable Holter Patient Recorder, Brain-Computer Interface (EEG) Acquisition, Multi-Modal Wearable ECG + Respiration Patch, Stress-Test / Exercise ECG System, Patient Monitor with SpO2 + ECG Bedside Module.

💊

12-Lead Clinical ECG Monitor

The ADS1298CZXGT's 8-channel simultaneous sampling at 24-bit resolution makes it ideally suited as the core AFE for a 12-lead clinical ECG monitor, where 8 differential chest/limb electrodes provide the 12 standard clinical views via Einthoven and Goldberger derivations. With approximately 4 uVPP input-referred noise at 150 Hz bandwidth (PGA gain = 6) and integrated right-leg-drive (RLD) amplifier for common-mode rejection, it eliminates the need for a discrete instrumentation amp front-end. Designers place the 8 INxP/INxN pairs at the patient lead interface, use the RLD amplifier to actively drive the patient common-mode back to the body, and leverage the digital 50/60 Hz line rejection to meet IEC 60601-1-2 EMI/EMC margins in international deployments. Trade-off: total power is 14.1 mW continuous, so a low-power standby mode using the internal pace-detect wakeup is recommended for battery-powered cart applications.

📱

Portable Holter Patient Recorder

For ambulatory Holter recorders operating on AA or rechargeable Li-ion cells, the ADS1298CZXGT's 14.1 mW dissipation is low enough to support 24-72 hours of continuous multi-channel recording on a compact battery, while the integrated 2.5 V reference and internal oscillator remove external components that would otherwise drain idle current. Engineers typically run the part at 500 SPS to 1 kSPS per channel in high-resolution mode to reduce average current while preserving diagnostic signal quality for the cardiologist's post-event analysis. The pace-detection circuitry is critical for Holter use - it flags pacemaker pulses so the Holter software can distinguish them from intrinsic QRS complexes. Watch the NFBGA-64 footprint for reflow profile: a peak temperature of 245 C with 60 sec above 220 C is typical for the BGA assembly, and conformal coating is recommended for sweat/skin-contact ambulatory housings.

🧩

Brain-Computer Interface (EEG) Acquisition

Multi-channel EEG systems (32-256 electrodes) commonly use multiple ADS1298CZXGT parts synchronized via the daisy-chain SPI interface to acquire dense scalp electrode arrays. The 24-bit dynamic range comfortably captures sub-100 uV EEG microstates (P300, alpha rhythm) while rejecting the larger motion and DC offset artifacts common in scalp recordings. The integrated lead-off detection (both AC and DC modes per the datasheet) is critical for clinical EEG, where a single detached electrode renders the entire acquisition run unusable. Pair each ADS1298CZXGT with a digital isolator (e.g., SI8442AB) on the SPI bus for patient safety compliance under IEC 60601-1. The wide PGA gain range (1-12 V/V) lets the same chip serve both pediatric EEG (higher gain) and adult EMG (lower gain) channels in a multi-modal research system.

⚡

Multi-Modal Wearable ECG + Respiration Patch

In a single adhesive chest patch combining single-lead ECG with respiration impedance pneumography, the ADS1298CZXGT and its 'R'-suffix sibling ADS1298RIZXG (pin-compatible, same 64-NFBGA footprint) provide a unified 8-channel AFE platform. The standard ADS1298CZXGT handles ECG channels while leaving the respiration modulator off; if the design later needs respiration, the 'R' part drops onto the same land pattern without PCB rework. With 14.1 mW dissipation across 8 channels, the device leaves ample power budget for BLE radio and 9-axis IMU on a coin-cell or rechargeable Li-Po. The integrated pace-detection is a bonus for patients with implanted pacemakers, since the patch can flag and time-stamp pacemaker pulses alongside the ECG trace.

🏭

Stress-Test / Exercise ECG System

Stress-test ECG systems must capture clean ECG waveforms during vigorous patient motion, making the ADS1298CZXGT's integrated right-leg-drive amplifier and 50/60 Hz digital line rejection essential for maintaining diagnostic signal quality under sweat and motion artifacts. The 8-channel simultaneous sampling ensures all 12 leads are captured at exactly the same instant, which is critical for accurate ST-segment and arrhythmia analysis during peak exercise. The chip's ability to drive 2 kSPS per channel supports HRV (heart rate variability) time-domain and frequency-domain analysis that cardiologists use to assess autonomic function. For treadmill vibration isolation, mount the ADS1298CZXGT near the patient cable entry on a stiffener section of the PCB with guard rings around the analog input traces per the datasheet layout guide.

🖥️

Patient Monitor with SpO2 + ECG Bedside Module

Bedside patient monitors integrate ECG, SpO2, NIBP, and respiration into a single cart, and the ADS1298CZXGT is often the dedicated ECG subsystem AFE, leaving its 8 channels to handle the standard 5-lead or 12-lead configuration plus a respiration impedance channel. The 14.1 mW power is trivial on mains-powered cart systems, but the integrated pace-detection and lead-off features are mandatory for ICU-grade monitors that must reliably detect pacemaker pulses and instantly alarm on detached leads. Designers should allocate 2.2 uF ceramic decoupling per AVDD pin and add a ferrite bead on the analog supply to keep switching-noise from the cart's other subsystems out of the ECG signal path. Use the device's internal oscillator in production to reduce BOM cost; use an external clock only if the monitor needs synchronized acquisition across multiple AFEs.

What is the ADS1298CZXGT and what is it used for?
The ADS1298CZXGT is a Texas Instruments 8-channel, 24-bit analog front-end (AFE) for biopotential measurements, integrating eight simultaneous-sampling delta-sigma ADCs with PGAs, right-leg-drive amplifier, lead-off detection, and pace detection in a 64-NFBGA (ZXG) 8x8 mm package. It is used primarily in clinical ECG, Holter, patient monitoring, EEG, and EMG designs where a complete per-channel signal chain replaces a discrete instrumentation-amp-plus-ADC approach.
What is the input-referred noise of the ADS1298CZXGT?
The ADS1298CZXGT achieves an input-referred noise of approximately 4 uVPP at a 150 Hz bandwidth with PGA gain set to 6 V/V, according to the TI ADS1298 datasheet. This low noise floor is essential for resolving the small (1-5 mV) ECG waveform amplitudes and is one of the key reasons the family displaced discrete three-op-amp instrumentation amplifier + 24-bit ADC designs in medical instrumentation.
What is the operating temperature range of the ADS1298CZXGT?
The ADS1298CZXGT (commercial-grade, 'C' suffix) operates from 0 C to +70 C ambient temperature. For extended or industrial temperature ranges, the TI 'I' suffix variant (ADS1298IZXG) supports -40 C to +85 C, while the 'R' medical-grade variants target 0 C to +70 C for patient-monitoring applications; always confirm the temperature suffix against your deployment scenario before laying out the BOM.
Where to buy ADS1298CZXGT online?
The ADS1298CZXGT can be purchased from authorized distributors including DigiKey, Mouser, Arrow, and TI.com, with stock levels shown on each distributor's product page. As of 2026-10-06, XAIPART's listed distributor pricing for qty-1 is approximately 36.42 USD, with quantity discounts at 100/500/1000 dropping to 28.15/24.10/20.85 USD respectively.
What is the lead time for ADS1298CZXGT?
Lead time for the ADS1298CZXGT is typically 8-12 weeks from TI authorized distributors as of 2026-10-06, given its NFBGA packaging and medical-grade supply chain. For prototype urgency, Mouser and DigiKey generally maintain small reel stock; for production runs, contacting TI directly or using XAIPART's BOM services is recommended to confirm allocation.
What is the price of ADS1298CZXGT?
The unit price of ADS1298CZXGT starts at approximately 36.42 USD at qty-1 as of 2026-10-06 on distributor channels, falling to 20.85 USD at qty-1000. Pricing reflects its high channel count, NFBGA packaging, and integrated biopotential features; the cost is roughly 3-4x that of a 4-channel ADS1294 in the same family, which is the trade-off for doubling the channel count.
ADS1298CZXGT vs ADS1298IPAG - which is better for portable ECG?
For portable ECG, the ADS1298IPAG (TQFP-64, 'I' industrial temp suffix) is generally preferred over the ADS1298CZXGT because the TQFP-64 package is easier to hand-solder and rework, and the industrial -40 C to +85 C range supports outdoor/ambulatory use. The ADS1298CZXGT in NFBGA is best for high-density production boards where PCB area is constrained and assembly is fully automated.
What is the difference between ADS1298 and ADS1298R?
The ADS1298 and ADS1298R differ in the integrated respiration-impedance measurement feature: the 'R' suffix (ADS1298R) adds built-in respiration modulation circuitry and an AC lead-off option optimized for impedance pneumography, while the standard ADS1298 (which the ADS1298CZXGT is part of) does not include the respiration modulator. Both share identical channel count, sample rate, and pinout; the 'R' is pin-compatible drop-in.
When should I choose ADS1298CZXGT over ADS1294CZXGT?
Choose the ADS1298CZXGT over the ADS1294CZXGT when your design needs 8 channels of simultaneous biopotential acquisition (e.g., full 12-lead ECG derived from 8 differential channels, or multi-modal EEG/EMG). Choose the ADS1294CZXGT when you only need 4 channels (e.g., single-lead wearable ECG or simple EMG); the 4-channel variant has the same NFBGA package but lower cost and power.
What is the best drop-in replacement for ADS1298CZXGT?
The best drop-in replacement for the ADS1298CZXGT (same 64-NFBGA package, same register set) is the ADS1298CZXGR (TI tape-and-reel variant), followed by the ADS1298IZXG for extended-temperature applications. Both share identical pinout and electrical characteristics, differing only in operating temperature grade or reel packaging.
Can ADS1298IPAP replace ADS1298CZXGT?
No, the ADS1298IPAP cannot directly replace the ADS1298CZXGT because the ADS1298IPAP is in a TQFP-64 package while the ADS1298CZXGT is in an NFBGA-64 package; the land patterns are different and PCB rework would be required. If your design is in NFBGA, stay within the ADS1298CZXG-family pin-compatible variants; if TQFP, use ADS1298IPAG-family parts.
Where to download ADS1298CZXGT datasheet PDF?
The official ADS1298CZXGT datasheet PDF can be downloaded from the TI product page at https://www.ti.com/lit/ds/symlink/ads1298.pdf, which is the manufacturer's authoritative document containing the full electrical specifications, register map, application circuit, and pinout for the ADS1298 family including the ADS1298CZXGT variant.
Where to find ADS1298CZXGT pinout?
The complete ADS1298CZXGT pinout is found in the TI datasheet's Pin Configuration and Functions section, where the 64-NFBGA (ZXG) ball map is shown with AVDD/DVDD pins, eight analog input pairs (IN1P/IN1N through IN8P/IN8N), RLDIN/RLDOUT, TEST, CLK, RESET, DRDY, and SPI signals (CS, SCLK, DIN, DOUT) labeled. XAIPART also renders the standard NFBGA-64 ball diagram on its product page for this part.
What are the key specifications of ADS1298CZXGT that engineers should know?
Engineers evaluating the ADS1298CZXGT should focus on these top five specifications: 8 simultaneous-sampling 24-bit channels at up to 32 kSPS per channel, 14.1 mW total power dissipation, integrated PGA with 1-12 V/V gain, approximately 4 uVPP input-referred noise at 150 Hz BW, and built-in right-leg-drive amplifier plus lead-off and pace detection. Combined, these eliminate the need for an external instrumentation amp, dedicated pace detect IC, and lead-off switch matrix in a clinical ECG design.
What is the best Analog Devices equivalent for ADS1298CZXGT?
The closest Analog Devices equivalent to the ADS1298CZXGT (8-channel, 24-bit biopotential AFE) is the ADAS1000 / ADAS1000-1 family, though note that the ADAS1000 is typically offered in a different (LQFP-56) package and has 5-6 ECG channels rather than 8 simultaneous biopotential channels. Designers should evaluate the AD7771, AD7768, or ADI's bioelectric AFE portfolio against specific channel-count and ECG vs. general-biomedical requirements; cross-brand drop-in compatibility in NFBGA-64 is uncommon due to differing pinouts.

Dados de referência de engenharia para ADS1298CZXGT — comparação, orientação de projeto e informações de conformidade.

Guia de seleção

Choose the ADS1298CZXGT for high-density 12-lead clinical ECG, Holter, or multi-channel biopotential designs where 8 simultaneous-sampling 24-bit channels are required in a compact 8x8 mm NFBGA-64 footprint, commercial 0-70 C operating range is acceptable, and respiration impedance pneumography is NOT needed (use the ADS1298RIZXG drop-in if respiration IS required). For hand-rework prototypes or low-density production, switch to the TQFP-64 ADS1298IPAG family (NOT pin-compatible with NFBGA). For industrial or wearable temperature range, select the ADS1298IZXG drop-in. For 4-channel only designs, choose the lower-cost ADS1294 family. Avoid using the ADS1298CZXGT in designs requiring 24 kHz pacemaker detection or external clock synchronization above the internal 512 kHz without first verifying the START and CLK register configuration against the latest TI datasheet errata.

Comparação com alternativas

Parâmetro Este produto ADS1298CZXGR ADS1298IZXG ADS1298RIZXG ADS1298RIZXGR ADS1298CZXG
Brand Texas Instruments Texas Instruments Texas Instruments Texas Instruments Texas Instruments Texas Instruments
Package 64-NFBGA (ZXG) 64-NFBGA (ZXG) - same 64-NFBGA (ZXG) - same 64-NFBGA (ZXG) - same 64-NFBGA (ZXG) - same 64-NFBGA (ZXG) - same
Channels 8 8 8 8 8 8
Resolution 24-bit 24-bit 24-bit 24-bit 24-bit 24-bit
Operating Temperature 0 C to +70 C 0 C to +70 C -40 C to +85 C -40 C to +85 C -40 C to +85 C 0 C to +70 C
Respiration Modulation No No No Yes (respiration-capable) Yes (respiration-capable) No
Sample Rate (max per channel) 32 kSPS 32 kSPS 32 kSPS 32 kSPS 32 kSPS 32 kSPS

Principais diferenciais

  • Only 64-NFBGA option with commercial temperature grade and standard (no respiration) modulator (vs ADS1298RIZXG)
  • Extended -40 C to +85 C range on same NFBGA footprint for ambulatory use (vs ADS1298IZXG)
  • Lower unit cost than respiration-capable variant (vs ADS1298RIZXGR)

Notas de projeto

Place 2.2 uF X7R ceramic decoupling capacitors immediately adjacent to each AVDD1/AVDD2/AVDD3/AVDD4 and DVDD ball, with the ground-side via stitching forming a tight ground-return path. Route analog input traces (IN1P/N through IN8P/N) as differential pairs on the top layer with no via transitions, and surround each pair with a continuous ground guard ring tied to AVSS. Keep SPI traces (CS, SCLK, DIN, DOUT, DRDY) routed on a different layer or far from analog inputs to preserve the >100 dB CMRR at 50/60 Hz. Estimated: with a 4-layer FR4 stackup and the recommended BGA escape routing, the achievable CMRR is typically within 6-10 dB of the datasheet figure.

Power the ADS1298CZXGT's analog rail (AVDD) from a low-noise LDO such as the TI TPS7A4701 (4.17 uVrms noise, 72 dB PSRR at 1 kHz) rather than a switching buck regulator, because high-frequency switching ripple couples directly into the 24-bit ADC and can corrupt ECG baseline. Place a ferrite bead (600-1000 ohm at 100 MHz) in series between the switching pre-regulator output and the LDO input to suppress switching noise. Estimated: at 14.1 mW total dissipation and 3.3 V AVDD, total AVDD current is approximately 4.3 mA, well within the TPS7A4701's 1 A rating with substantial headroom.

A common pitfall is leaving unused analog input channels floating instead of tying them to AVDD via a 10 kohm resistor as the datasheet recommends - floating inputs can pick up ambient EMI and produce spurious codes in adjacent active channels. Another pitfall is forgetting to enable the internal 2.5 V reference (REG register bit) before starting conversions, which results in all-zero output and a confused DRDY signal. Always assert RESET (low pulse) at power-up and wait at least 18 / fCLK (about 1 ms with internal 512 kHz oscillator) before issuing the SDATAC + START sequence per the datasheet's recommended power-up timing.

Informações de conformidade

RoHS
Compliant
REACH
Compliant
AEC-Q100
Not Applicable
Sem chumbo
Yes
Sem halogênios
Unknown
Minerais de conflito
Compliant

RoHS and REACH compliance per TI product page. AEC-Q100 is not applicable - this part is not automotive-qualified (use automotive biopotential AFE portfolio for vehicle ECG). Conflict-minerals compliance per TI standard declaration.

Dados verificados em: 2026-10-06 — dados verificados e curados pela equipe de engenharia de componentes da XAIPART

Buscas relacionadas

ADS1298CZXGT ADS1298CZXGT datasheet PDF Texas Instruments ADS1298 ECG AFE 8 channel 24-bit ECG analog front end NFBGA ADS1298CZXGT buy price stock ADS1298CZXGT vs ADS1298IPAG ADS1298CZXGT drop-in replacement NFBGA-64 ADS1298CZXGT lead time distributor stock ADS1298CZXGT pinout ball map biopotential AFE 24-bit 8 channel simultaneous sampling ADS1298CZXGT Holter patient monitor application what is the input referred noise of ADS1298

Componentes & termos relacionados

Texas Instruments ADS1298CZXGT ADS1298 ADS1298CZXGR ADS1298IZXG ADS1298RIZXG ADS1294 analog front end AFE biopotential measurement electrocardiogram ECG EEG EMG Holter monitor delta-sigma ADC sigma-delta modulator programmable gain amplifier PGA right-leg drive RLD amplifier lead-off detection pace detection Wilson central terminal respiration impedance pneumography NFBGA package 64-ball BGA SPI interface digital isolation IEC 60601-1 RoHS REACH
RFQ de cotação rápida
Preencha todos os detalhes — nossa equipe de vendas responderá em até 24 horas
Part number Fabricante Encapsulamento QTY Preço-alvo Total
Total: $0.00 USD
✓
Cotação enviada!

Responderemos seu e-mail em até 24 horas

1
RFQ enviada
2
Cotação recebida
3
Pedido realizado
4
Pagamento
5
Enviado
6
Entregue