ams OSRAM

AS7030B-EVALKIT - PPG/ECG Biometric Sensor Eval Kit | ams OSRAM

N.º da peça: AS7030B-EVALKIT ✓ Ativo
Em estoque Enviado em 1 a 3 dias úteis
Contato para preços
MOQ: 1 |
Preço atualizado: 2026-10-11
Preços por volume
Qtd. Preço unitário Total
1 $0 $0,00
10 $0 $0,00
100 $0 $0,00
500 $0 $0,00
1.000 $0 $0,00
ℹ️ Todos os preços estão em USD

AS7030B-EVALKIT Visão geral

The ams OSRAM AS7030B-EVALKIT is a biometric sensor evaluation kit for the AS7030B vital-sign sensor, enabling full evaluation of embedded ECG and photoplethysmography (PPG) functions through a USB-connected Windows PC platform.

A biometric sensor evaluation kit is a complete hardware and software development platform that lets engineers characterize a sensor before committing it to a wearable or medical product design. In the sensor development hierarchy, it sits above the bare sensor IC and below end-product integration: sensor IC -> sensor module -> evaluation board -> development kit -> production design. The AS7030B-EVALKIT family includes USB and Bluetooth variants that isolate the wearer from mains power via an IEC 60601-1 compliant RECOM DC/DC converter (R0.25S-0505/H or R0.25S-0505/HP) and signal isolators.

Key capabilities include simultaneous ECG and PPG acquisition, an integrated low-noise analog front end, a synchronous demodulator, and on-board temperature sensor and accelerometer on a detachable break-out board connected via FPC cable. According to the AS7030B datasheet, the sensor includes an I2C slave at 7-bit address 0x30 (60h write / 61h read) and an interrupt output pin INT for host signaling.

Architecturally, the kit splits functions between a motherboard (USB or Bluetooth host interface, isolation, power) and a biosensor break-out board carrying the AS7030B, electrodes, and auxiliary sensors. The AS7030B itself combines optical PPG channels with an ECG channel and galvanic skin response sensing in one device, targeting low-power, small-footprint fitness bands, smart watches, sports watches, and smart patches requiring multi-day battery life.

Typical applications include heart-rate and HRV algorithm prototyping, ECG signal-chain validation, GSR (galvanic skin response) stress monitoring studies, and early firmware development for medical and consumer wearables.

A key design consideration: always power the kit through the supplied isolation stage when attaching electrodes to a human subject, since the on-board IEC 60601-1 compliant RECOM converter exists specifically to prevent direct galvanic connection to the power grid.

This page synthesizes distributor availability data, the official ams OSRAM user guide, and drop-in kit-variant comparisons not consolidated in the manufacturer datasheet.

Alternativas drop-in para AS7030B-EVALKIT — mesmo encapsulamento, compatível pino a pino. Peças de encapsulamento diferente que exigem retrabalho na PCB são excluídas.

Ferramenta de comparação rápida — selecione peças alternativas para comparação lado a lado:

AS7030B_EVALKIT_USB

✅ Drop-In
📦 Evaluation Kit (motherboard + break-out board)
USB host connection instead of Bluetooth; identical AS7030B sensor silicon, same isolation and break-out board

📋 Alternativa de referência (fora do catálogo)

AS7030B_EVALKIT_BT

✅ Drop-In
📦 Evaluation Kit (motherboard + break-out board)
Bluetooth host connection for untethered measurement; identical AS7030B sensor silicon and break-out board

📋 Alternativa de referência (fora do catálogo)

AS703x_EVM_SN

✅ Drop-In
📦 Evaluation Kit (motherboard + break-out board)
same kit platform per ams product page; evaluates AS7030B/AS7038GB/AS7038RB with FPC-coupled biosensor break-out board

📋 Alternativa de referência (fora do catálogo)

AS7038GB-EVALKIT

✅ Drop-In
📦 Evaluation Kit (motherboard + break-out board)
evaluates AS7038GB biosensor variant on the same kit family platform; different sensor channel configuration

📋 Alternativa de referência (fora do catálogo)

AS7038RB-EVALKIT

✅ Drop-In
📦 Evaluation Kit (motherboard + break-out board)
evaluates AS7038RB biosensor variant on the same kit family platform; different sensor channel configuration

📋 Alternativa de referência (fora do catálogo)

AS7030B-EVALKIT Especificações (publicadas pelo fabricante)

Product Type Biometric Sensor Evaluation Kit
Target Sensor AS7030B biosensor (ECG, PPG, GSR)
Sensed Parameters ECG, photoplethysmography (PPG), galvanic skin response (GSR)
Communication Interface I2C slave (7-bit address 0x30, 60h write / 61h read)
Interrupt Output INT pin for host interrupt
Host Connection USB or Bluetooth (variant dependent)
Supported OS Windows
Isolation IEC 60601-1 compliant RECOM DC/DC converter R0.25S-0505/H or R0.25S-0505/HP
On-Board Sensors Temperature sensor, accelerometer, electrodes on break-out board
Board Architecture Motherboard + detachable biosensor break-out board via FPC cable
Auxiliary Sensor Option Supports AS7038GB and AS7038RB biosensor variants
Analog Front End Low-noise AFE with synchronous demodulator
Typical Applications Fitness bands, smart watches, sports watches, smart patches

Interfaces e Conectores do AS7030B-EVALKIT

Não há lista de interfaces publicada pelo fabricante disponível para AS7030B-EVALKIT. Consulte a documentação do fabricante para detalhes de conectores e headers.

Consulte a documentação do fabricante para a pinagem completa do conector de expansão e a numeração dos pinos do conector.

Aplicações típicas

AS7030B-EVALKIT é adequado para 6 aplicaçãos: Fitness Band and Smart Watch Development, ECG Signal Chain Validation, GSR Stress and Hydration Monitoring Research, Smart Patch and Multi-Day Battery Wearables, Medical Wearable Prototyping and Algorithm Development, Optical Sensor Education and Lab Training.

📱

Fitness Band and Smart Watch Development

The AS7030B-EVALKIT directly supports wearable heart-rate product development because the AS7030B's low-power design and small form factor are explicitly targeted at fitness bands, smart watches, and sports watches per the ams OSRAM datasheet. Engineers use the kit's detachable break-out board to test optical PPG placement on a wrist or chest form factor while streaming data over USB or Bluetooth to the PC GUI. The synchronous demodulator in the low-noise analog front end suppresses ambient light interference, and the INT interrupt pin maps naturally to motion-triggered sampling in firmware. Validated register configurations transfer directly from kit evaluation to production PCB, reducing design risk before layout commitment.

💊

ECG Signal Chain Validation

For ECG algorithm and analog-front-end validation, the kit provides an embedded ECG channel with a low-noise AFE, electrodes on the break-out board, and a safety isolation stage using the IEC 60601-1 compliant RECOM R0.25S-0505/H DC/DC converter. According to the ams OSRAM user guide, isolator ICs on all signals guarantee no physical connection between subject electrodes and the power grid, enabling safe on-body capture over USB power. Engineers can validate lead-off handling, noise floor, and sampling behavior in the PC GUI before porting the register map to a production microcontroller such as an XMC series MCU over the documented I2C address 0x30.

🧩

GSR Stress and Hydration Monitoring Research

The AS7030B integrates galvanic skin response (GSR) sensing, and the evaluation kit exposes this channel alongside ECG and PPG so researchers can study stress, hydration, and electrodermal activity with a single instrument. MIKROE's ECG/GSR Click confirms the AS7030B is positioned by the manufacturer as a vital-sign sensor covering both ECG and GSR operations. Using the kit's PC software, investigators log simultaneous GSR and heart-rate waveforms during controlled stimulus protocols, using the temperature sensor and accelerometer on the break-out board as contextual channels. This multi-modal capture shortens study cycles compared with discrete GSR plus PPG instrumentation, while the USB isolation stage maintains subject safety.

⚡

Smart Patch and Multi-Day Battery Wearables

Smart patches impose strict energy budgets, and the ams OSRAM datasheet states the AS7030B's low-power design suits applications where users expect extended, multi-day intervals between battery recharges. The evaluation kit lets designers quantify this claim empirically: by configuring LED duty cycles, ECG sampling rates, and interrupt-driven operation through the INT pin, firmware teams measure actual average current on the kit before committing a battery. The detachable break-out board emulates a patch's flexible substrate placement, and the Bluetooth variant enables realistic motion testing untethered from the bench. Results feed directly into battery sizing and duty-cycle decisions for the final patch product.

🎥

Medical Wearable Prototyping and Algorithm Development

Medical device teams use the AS7030B-EVALKIT to prototype vital-sign algorithms ahead of formal design controls. The kit delivers synchronized ECG and PPG streams plus contextual temperature and motion data through a documented interface (I2C address 0x30, INT interrupt), letting algorithm engineers develop heart-rate variability, pulse transit time, or arrhythmia-detection prototypes against real captured data. The IEC 60601-1 compliant isolation, implemented with the RECOM R0.25S-0505/H converter and signal isolators, means subject recordings can be gathered under essentially the same safety architecture that a production device will require, per the ams OSRAM user guide. This reduces the gap between feasibility studies and design-verification testing.

🖥️

Optical Sensor Education and Lab Training

Universities and training labs adopt the AS7030B-EVALKIT as a hands-on platform for biomedical instrumentation courses because it exposes a complete photoplethysmography, ECG, and GSR signal chain with professional isolation practice built in. Students observe the synchronous demodulator's effect on motion artifact, configure the I2C register map at address 0x30, and capture their own physiological signals safely thanks to the IEC 60601-1 compliant RECOM isolation converter documented in the user guide. The AS7030B USB EVALUATION KIT is listed by DigiKey as an optical sensor evaluation board and ships same-day when stocked, making it practical for semester lab setups. The Windows GUI requires no embedded programming for first experiments.

Resumo dos produtos recomendados

AS7030B ams-OSRAM Usado em: Fitness Band and Smart Watch Development, GSR Stress and Hydration Monitoring Research XMC1404-F064X0128 Infineon Usado em: Fitness Band and Smart Watch Development XMC4500F100F1024AC Infineon Usado em: ECG Signal Chain Validation RECOM R0.25S-0505/H IEC 60601-1 isolation converter used on the kit Usado em: ECG Signal Chain Validation AS703x_EVM_SN Alternate kit platform for the same study Usado em: GSR Stress and Hydration Monitoring Research AS7030B_EVALKIT_BT Bluetooth variant for untethered battery-life testing Usado em: Smart Patch and Multi-Day Battery Wearables XMC1404Q064X0200AAXUMA1 Infineon Usado em: Smart Patch and Multi-Day Battery Wearables XMC4300-F100F256 Infineon Usado em: Medical Wearable Prototyping and Algorithm Development ZSSC4151AE2R Renesas Electronics Usado em: Medical Wearable Prototyping and Algorithm Development AS7030B_EVALKIT_USB USB variant used in bench lab settings Usado em: Optical Sensor Education and Lab Training XMC1301Q040F0008ABXUMA1 Infineon Usado em: Optical Sensor Education and Lab Training
What is the AS7030B-EVALKIT and what does it measure?
The AS7030B-EVALKIT is an ams OSRAM evaluation kit for the AS7030B biometric sensor that measures ECG, photoplethysmography (PPG), and galvanic skin response (GSR). According to the AS7030B product document PD000544, the sensor embeds an ECG channel with a low-noise analog front end and a synchronous demodulator. The kit ships as a motherboard plus a detachable biosensor break-out board with electrodes, a temperature sensor, and an accelerometer, connected via FPC cable for flexible placement.
Where can I buy the AS7030B-EVALKIT online?
The AS7030B-EVALKIT family is available from Mouser Electronics (AS7030B_EVALKIT_USB and AS7030B_EVALKIT_BT), DigiKey Electronics (listed as AS7030B USB EVALUATION KIT, ships same day), Arrow.com, and Ampheo. Pricing and stock vary by variant; XAIPART provides quote-based sourcing for the kit. Always confirm the exact variant (USB vs Bluetooth) before ordering, as they serve different host-connection workflows but evaluate the identical AS7030B sensor silicon.
How much does the AS7030B-EVALKIT cost?
Exact unit pricing for the AS7030B-EVALKIT was not confirmed in the latest verified distributor data as of 2026-10-11, so this page does not publish a fixed price. Evaluation kits of this class typically range from approximately 100 to 300 USD at distributors such as Mouser and DigiKey, but you should request a current quote, since ams OSRAM kit pricing fluctuates with stock and regional distributor policies. Contact XAIPART sales for a live quotation with lead time.
What is the lead time and stock status for the AS7030B-EVALKIT?
DigiKey lists the AS7030B USB EVALUATION KIT with same-day shipping when in stock, indicating normal availability through major distribution as of 2026-10-11. Mouser and Arrow also stock the USB and Bluetooth variants. Lead times for stocked kits are typically 1-3 business days for standard shipping; if a distributor shows zero stock, factory lead time from ams OSRAM may extend several weeks. Request a quote from XAIPART for confirmed availability.
What is the difference between AS7030B_EVALKIT_USB and AS7030B_EVALKIT_BT?
The two kits evaluate the identical AS7030B biosensor but differ in host connectivity. The AS7030B_EVALKIT_USB connects to a Windows PC via USB for bench-top evaluation, while the AS7030B_EVALKIT_BT uses Bluetooth for untethered, mobile measurements such as during exercise. Both use the same isolation scheme (IEC 60601-1 compliant RECOM R0.25S-0505/H converter) and the same detachable biosensor break-out board, so firmware and algorithm work transfers directly between them.
AS7030B-EVALKIT vs MAX30003 evaluation kit - which is better for wearables?
The AS7030B-EVALKIT is better when you need combined ECG, PPG, and GSR in one platform, while Maxim/ADI MAX30003-based kits excel at single-channel, ultra-low-power ECG only. The AS7030B integrates optical PPG with an embedded ECG channel and a synchronous demodulator, letting one kit prototype multi-modal vital-sign algorithms. If your product only needs ECG and you prioritize minimal power, the MAX30003 route may fit; for combined heart-rate plus ECG wearables, choose the AS7030B kit.
When should I choose the AS7030B-EVALKIT over the AS7038GB or AS7038RB kits?
Choose the AS7030B-EVALKIT when your target application requires the standard AS7030B sensor configuration with ECG, PPG, and GSR capability. The same evaluation platform also supports AS7038GB and AS7038RB biosensor variants, which differ in LED/channel configuration, so pick those kits only if your production part is an AS7038 device. Because the user guide (AS703xxB UG) covers all three sensors on one kit family, software investment is shared across variants.
Is the AS7030B-EVALKIT suitable for medical product development?
Yes, with caveats. The kit is an evaluation tool, not a certified medical device, but it incorporates patient-safety provisions: an IEC 60601-1 compliant RECOM DC/DC converter (R0.25S-0505/H or R0.25S-0505/HP) and isolator ICs on all signals ensure no direct galvanic connection between the subject and mains power, per the ams OSRAM user guide. Use it to validate algorithms and signal chains, then design a production AFE based on the AS7030B IC for the certified end product.
What is the best drop-in replacement for the AS7030B-EVALKIT?
The closest same-manufacturer replacement is the ams AS703x_EVM_SN evaluation kit, which evaluates all functions of the AS7030B/AS7038GB/AS7038RB biosensors on the same motherboard plus break-out-board architecture. Within the kit family, AS7030B_EVALKIT_USB and AS7030B_EVALKIT_BT are interchangeable evaluation platforms for the same silicon. No competing vendor kit is pin-compatible with a complete evaluation platform, so the practical equivalent is another AS703x-family kit from ams OSRAM.
What is the best ams OSRAM alternative kit if AS7030B-EVALKIT is unavailable?
Order the AS703x_EVM_SN evaluation kit from ams OSRAM; according to the manufacturer product page it is designed to evaluate all functions of the AS7030B, AS7038GB, and AS7038RB biosensors with the biosensor, temperature sensor, accelerometer, and electrodes on a detachable break-out board reconnected via FPC cable. It is functionally the same evaluation platform and uses the same PC software toolchain, so results and firmware developed on either kit remain applicable.
Where can I download the AS7030B datasheet PDF?
Download the official AS7030B datasheet PDF from the ams OSRAM website at ams-osram.com (product document PD000544); the 129-page document is also mirrored on Alldatasheet and SparkFun's CDN. For kit-specific setup instructions, download the AS7030B Evaluation Kit User Guide from Mouser (document UG000493/UG001014 family), which covers USB connection, the isolation scheme, and the GUI software workflow.
Where do I connect electrodes on the AS7030B evaluation kit?
Electrodes attach to the detachable biosensor break-out board, which carries the AS7030B sensor, the electrode connectors, the temperature sensor, and the accelerometer. Per the ams OSRAM user guide, this break-out board can be used in any application and reconnected to the main board via an FPC cable, allowing electrode placement on a subject while the USB or Bluetooth motherboard remains isolated. Signals passing to the sensor board pass through isolator ICs for subject safety.
Is the AS7030B-EVALKIT safe to connect to a human subject?
Yes, the kit is designed for on-body measurement. According to the ams OSRAM AS7030B user guide, an IEC 60601-1 compliant RECOM DC/DC converter (R0.25S-0505/H or R0.25S-0505/HP) and isolator ICs on all signals ensure there is no physical connection between the electrodes and the power grid when the kit is supplied over USB. Always use the kit as delivered with its isolation stage intact; never bypass the RECOM converter when attaching electrodes.
What are the key specifications of the AS7030B-EVALKIT that engineers should know?
Key facts: the kit evaluates the AS7030B biosensor integrating ECG, PPG, and GSR sensing with a low-noise analog front end and synchronous demodulator. Host interface is USB or Bluetooth (Windows software). The sensor communicates via I2C at 7-bit address 0x30 with an INT interrupt output. Safety isolation uses an IEC 60601-1 compliant RECOM R0.25S-0505/H converter. The platform targets fitness bands, smart watches, and smart patches requiring multi-day battery life. (Sources: ams OSRAM datasheet PD000544 and Evaluation Kit User Guide.)
Is the AS7030B the same as the AS7038GB?
No, they are related but distinct biosensor variants in the AS703x family. The AS7030B, AS7038GB, and AS7038RB share the same evaluation kit platform and user guide, meaning the software and board architecture are common, but each variant has its own datasheet section covering its channel and LED configuration. Verify your production sensor part number against the correct datasheet section; the kit itself supports evaluating all three variants by swapping the biosensor break-out board.
Does the AS7030B support I2C communication and what is its address?
Yes, the AS7030B includes an I2C slave interface. According to the AS7030B product document PD000544, the 7-bit I2C address is 0x30, which corresponds to 60h for writing and 61h for reading in 8-bit format (the R/W bit is appended to the 7-bit address). The device also provides an interrupt output pin INT that can signal the host on measurement-ready or event conditions, simplifying polling-free firmware design on the evaluation kit and in production.

Dados de referência de engenharia para AS7030B-EVALKIT — comparação, orientação de projeto e informações de conformidade.

Guia de seleção

Choose the AS7030B-EVALKIT when your product roadmap targets the AS7030B biosensor for combined ECG, PPG, and GSR measurement in a wearable. Pick the USB variant for bench-top signal-chain characterization and algorithm debugging under the Windows GUI; pick the Bluetooth variant (AS7030B_EVALKIT_BT) for untethered exercise, motion-artifact, and battery-life testing. If your production sensor might be an AS7038GB or AS7038RB instead, select the AS703x_EVM_SN platform, which covers all three AS703x devices on the same motherboard-plus-break-out-board architecture and shares the software investment. If you only need the bare AS7030B silicon on a compact carrier for an existing host board, MIKROE's ECG/GSR Click is a lower-cost route, but it forgoes the kit's IEC 60601-1 isolation and complete PC toolchain. For any human-subject measurement, insist on the isolated ams OSRAM kit hardware.

Comparação com alternativas

Parâmetro Este produto AS7030B_EVALKIT_USB AS7030B_EVALKIT_BT AS703x_EVM_SN
Package Evaluation Kit (motherboard + break-out board) Evaluation Kit (motherboard + break-out board) - same Evaluation Kit (motherboard + break-out board) - same Evaluation Kit (motherboard + break-out board) - same
Brand ams OSRAM ams OSRAM ams OSRAM ams OSRAM
Target Sensor AS7030B AS7030B AS7030B AS7030B / AS7038GB / AS7038RB
Measured Signals ECG, PPG, GSR ECG, PPG, GSR ECG, PPG, GSR ECG, PPG (per sensor variant)
Detach Break-Out Board Yes (FPC cable) Yes (FPC cable) Yes (FPC cable) Yes (FPC cable)
I2C Sensor Address 0x30 (7-bit) 0x30 (7-bit) 0x30 (7-bit) 0x30 (7-bit, AS7030B)

Principais diferenciais

  • Multi-modal sensing on one platform (vs AS7030B_EVALKIT_USB)
  • Untethered evaluation option (vs AS7030B_EVALKIT_USB)
  • Broader sensor coverage in one kit family (vs AS703x_EVM_SN)
  • Patient-safety isolation built in (vs AS7038GB-EVALKIT)

Notas de projeto

Never bypass or remove the on-board isolation when attaching electrodes. The kit deliberately includes an IEC 60601-1 compliant RECOM DC/DC converter (R0.25S-0505/H or R0.25S-0505/HP) plus isolator ICs on all signals so that, per the ams OSRAM user guide, there is no physical connection between the electrodes and the power grid when USB-powered. Powering the motherboard from an external supply or substituting a non-isolated converter defeats this protection and creates a patient-safety hazard.

Use the FPC cable between motherboard and biosensor break-out board to explore real mechanical placement before finalizing a wearable PCB. The manufacturer deliberately placed the AS7030B, temperature sensor, accelerometer, and electrodes on the detachable board so it can be used in any application. During PPG evaluation, shield the optical window from ambient light; the synchronous demodulator rejects interference best when LED current and sampling settings in the GUI are tuned together rather than independently.

When porting from the kit to a production board, respect the AS7030B's I2C timing at 7-bit address 0x30 (60h write / 61h read per datasheet PD000544) and use the INT interrupt output rather than polling to reduce bus traffic and average power. Keep the analog front end's supply clean: the kit's low-noise AFE performance depends on the isolated 5 V rail, so replicate the local decoupling shown on the evaluation board in your own layout.

Informações de conformidade

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
Sem chumbo
Unknown
Sem halogênios
Unknown
Minerais de conflito
Unknown

The evaluation kit integrates an IEC 60601-1 compliant RECOM DC/DC converter (R0.25S-0505/H or R0.25S-0505/HP) for patient isolation, per the ams OSRAM user guide. Kit-level RoHS/REACH status not stated in verified data.

Dados verificados em: 2026-10-11 — dados verificados e curados pela equipe de engenharia de componentes da XAIPART

Buscas relacionadas

AS7030B-EVALKIT AS7030B evaluation kit datasheet ams OSRAM AS7030B-EVALKIT AS7030B EVALKIT USB vs BT difference AS7030B ECG PPG sensor development kit price AS7030B biometric sensor evaluation kit buy AS7030B I2C address 0x30 wearable heart rate ECG PPG evaluation board AS7030B drop-in replacement evaluation kit what is the AS7030B sensor IEC 60601-1 isolated biometric eval kit AS7030B smartwatch GSR sensor kit

Componentes & termos relacionados

ams OSRAM AS7030B-EVALKIT AS7030B AS7030B_EVALKIT_USB AS7030B_EVALKIT_BT AS703x_EVM_SN AS7038GB AS7038RB evaluation kit development board biosensor photoplethysmography (PPG) electrocardiogram (ECG) galvanic skin response (GSR) I2C IEC 60601-1 RECOM R0.25S-0505/H MIKROE ECG/GSR Click DigiKey Mouser Electronics Arrow Electronics synchronous demodulator wearable health monitoring
RFQ de cotação rápida
Preencha todos os detalhes — nossa equipe de vendas responderá em até 24 horas
Part number Fabricante Encapsulamento QTY Preço-alvo Total
Total: $0.00 USD
✓
Cotação enviada!

Responderemos seu e-mail em até 24 horas

1
RFQ enviada
2
Cotação recebida
3
Pedido realizado
4
Pagamento
5
Enviado
6
Entregue