An analog-to-digital converter (ADC) is a data-conversion integrated circuit that samples continuous analog input signals and converts them into discrete digital codes for downstream digital signal processing. The CDK1307 sits inside the data-converter -> signal-chain -> mixed-signal IC hierarchy and is typically paired with a low-noise operational amplifier front-end and a downstream FPGA, DSP, or microcontroller. The "CILP40" suffix encodes both the temperature grade (-40 C to +85 C industrial range) and the 40-pin LQFP package.
Key features per the manufacturer datasheet include a single 3.3 V analog supply, internal 1.2 V reference, CMOS digital outputs, low standby current of 9 mW typical at 65 MSPS, and an external clock input with duty-cycle stabilizer. The converter accepts single-ended analog inputs typically centered at 1.5 V with a 1 Vpp full-scale range, and provides 12-bit or 13-bit selectable resolution through the configuration register.
Architecturally, the CDK1307CILP40 uses a multi-stage pipelined switched-capacitor core with proprietary digital error correction. This pipeline topology enables high sample rates (up to 80 MSPS) at low power consumption by distributing the conversion work across cascaded stages. The internal bandgap-based reference and integrated clock-receiver circuitry minimize external component count.
Typical applications include portable ultrasound front-ends, handheld industrial instrumentation, low-power imaging pipelines, IF/baseband digitizing for software-defined radio, and battery-powered test equipment. Designers also use the CDK1307 in medical patient-monitoring subsystems and portable oscilloscope front-ends where power budget is critical.
Design tip: route the analog and digital grounds as separate nets that join only at the EP/exposed-pad or at the AGND/DGND pin per the datasheet layout example. Place input coupling capacitors close to the AIN pin and bypass AVDD/DVDD with 0.1 uF ceramic + 10 uF tantalum pairs. Maintain a stable low-jitter clock at ENC+/ENC- to avoid degrading SNR.
This page synthesizes distributor stock data, drop-in alternatives, and practical layout guidance not collected in a single place in the manufacturer datasheet.
Alternativas drop-in para CDK1307CILP40 — mesmo encapsulamento, compatível pino a pino. Peças de encapsulamento diferente que exigem retrabalho na PCB são excluídas.
Variantes desta série
Modelos da mesma série compatíveis como drop-in com CDK1307CILP40 (mesmo formato e footprint) — diferindo em Package, Resolution, Architecture, Manufacturer, Reference.
Ferramenta de comparação rápida — selecione peças alternativas para comparação lado a lado:
CDK1307AILP40
✅ Drop-In ⚠️ Especificações não verificadas✓ Em estoque
$5.21 / unidade
Ver ficha técnica →CDK1307BILP40
✅ Drop-In ⚠️ Especificações não verificadas✓ Em estoque
$3.22 / unidade
Ver ficha técnica →CDK1307DILP40
✅ Drop-In ⚠️ Especificações não verificadas✓ Em estoque
$9.6 / unidade
Ver ficha técnica →CDK1308CILP40
✅ Drop-In ⚠️ Especificações não verificadas✓ Em estoque
$5.7 / unidade
Ver ficha técnica →CDK1307CILP40 Classificações máximas e características elétricas
| Part Number | CDK1307CILP40 |
| Manufacturer | MaxLinear (formerly Exar/Cadeka) |
| Função | Analog-to-Digital Converter (ADC) |
| Resolução | 12-bit / 13-bit selectable |
| Sample Rate | 65 MSPS (family supports 20/40/65/80 MSPS) |
| Architecture | Multi-stage pipeline with digital error correction |
| Input Type | Single-ended analog input |
| Full-Scale Input Range | 1 Vpp typical |
| Supply Voltage (Analog) | 3.3 V |
| Supply Voltage (Digital) | 3.3 V |
| Reference | Internal (1.2 V bandgap) |
| Output Interface | Parallel CMOS |
| Control Interface | CMOS serial configuration |
| Encapsulamento | 40-pin LQFP (LP) |
| Temperatura de operação | -40 C to +85 C (industrial) |
| Status RoHS | Compliant |
Configuração de pinos do CDK1307CILP40
| Pino 1 | AIN — Analog input (single-ended) |
| Pino 2 | AGND — Analog ground return |
| Pino 3 | AVDD — Analog 3.3 V supply |
| Pino 4 | VREF — Internal reference bypass node |
| Pino 5 | AGND — Analog ground |
| Pino 6 | NC — Not connected (per datasheet) |
| Pino 7 | ENC+ — Differential clock input (positive) |
| Pino 8 | ENC- — Differential clock input (negative) |
| Pino 9 | DGND — Digital ground |
| Pino 10 | DVDD — Digital 3.3 V supply |
| Pino 11 | PDWN — Power-down control input |
| Pino 12 | CS — Serial interface chip select |
| Pino 13 | SCLK — Serial configuration clock |
| Pino 14 | SDIO — Serial configuration data I/O |
| Pino 15 | DGND — Digital ground |
| Pino 16 | D0 — CMOS data output bit 0 (LSB) |
| Pino 17 | D1 — CMOS data output bit 1 |
| Pino 18 | D2 — CMOS data output bit 2 |
| Pino 19 | D3 — CMOS data output bit 3 |
| Pino 20 | D4 — CMOS data output bit 4 |
| Pino 21 | D5 — CMOS data output bit 5 |
| Pino 22 | D6 — CMOS data output bit 6 |
| Pino 23 | D7 — CMOS data output bit 7 |
| Pino 24 | D8 — CMOS data output bit 8 |
| Pino 25 | D9 — CMOS data output bit 9 |
| Pino 26 | D10 — CMOS data output bit 10 |
| Pino 27 | D11 — CMOS data output bit 11 |
| Pino 28 | D12 — CMOS data output bit 12 (MSB) |
| Pino 29 | OGND — Output driver ground |
| Pino 30 | OVDD — Output driver supply |
| Pino 31 | NC — Not connected (per datasheet) |
| Pino 32 | AGND — Analog ground |
| Pino 33 | AVDD — Analog 3.3 V supply |
| Pino 34 | NC — Not connected (per datasheet) |
| Pino 35 | NC — Not connected (per datasheet) |
| Pino 36 | NC — Not connected (per datasheet) |
| Pino 37 | NC — Not connected (per datasheet) |
| Pino 38 | NC — Not connected (per datasheet) |
| Pino 39 | NC — Not connected (per datasheet) |
| Pino 40 | EP — Exposed thermal pad - tie to AGND |
Aplicações típicas
CDK1307CILP40 é adequado para 6 aplicaçãos: Portable Ultrasound Front-End, IF Digitizing for Software-Defined Radio, Handheld Industrial Instrumentation, Low-Power Imaging Pipeline, Battery-Powered Test Equipment, Medical Patient Monitoring Subsystem.
Portable Ultrasound Front-End
The CDK1307CILP40 is well suited to portable ultrasound receiver channels. With 65 MSPS it comfortably samples IF frequencies up to 32 MHz while the 12/13-bit selectable resolution captures the dynamic range needed for echo envelopes. The ultra-low-power pipeline architecture keeps total front-end dissipation low enough for handheld probe assemblies. A typical signal chain pairs the CDK1307 with a low-noise op-amp (such as the AD797 family) feeding AIN, then routes parallel CMOS outputs to an FPGA for beamforming.
Recomendado
IF Digitizing for Software-Defined Radio
In SDR receivers the CDK1307CILP40 serves as the IF digitizer after a quadrature mixer. The 65 MSPS rate covers IF bandwidths up to 32 MHz, sufficient for narrowband and many wideband waveforms. The internal 1.2 V reference eliminates an external reference IC and the parallel CMOS outputs drop directly into an FPGA DSP fabric. The CMOS control interface allows mode switching and standby for battery-saving operation in field radios.
Recomendado
Handheld Industrial Instrumentation
Handheld oscilloscopes, vibration analyzers, and process calibrators use the CDK1307CILP40 as the main acquisition ADC. Its 12/13-bit resolution supports general-purpose waveform capture while the 65 MSPS rate provides 32 MHz of analog input bandwidth. The 40-pin LQFP allows compact PCB layouts and the low standby current extends battery life in field-portable products. An external anti-alias LPF precedes AIN to enforce clean Nyquist sampling.
Recomendado
Low-Power Imaging Pipeline
Line-scan and small-area CMOS imaging systems use the CDK1307CILP40 to digitize analog pixel streams. The 65 MSPS rate supports line rates up to several thousand lines per second, while 12/13-bit resolution preserves color depth and dynamic range. The internal reference and single 3.3 V supply minimize external BOM, critical for compact camera modules. CMOS outputs stream directly to an FPGA image-processing pipeline.
Recomendado
Battery-Powered Test Equipment
Portable data loggers, EMI sniffers, and bench instruments benefit from the CDK1307CILP40 ultra-low-power architecture. At 65 MSPS the standby power stays low enough for hours of battery operation between charges. The 12/13-bit resolution covers most field-measurement needs and the 1 Vpp full-scale input accommodates standard sensor signal levels with simple op-amp scaling. Parallel CMOS outputs feed a small MCU or FPGA for FFT and logging.
Recomendado
Medical Patient Monitoring Subsystem
Patient monitors measuring ECG, SpO2, or respiration waveforms use the CDK1307CILP40 as the primary acquisition ADC. The 65 MSPS rate is more than sufficient for physiological signals (typically under 10 kHz bandwidth) and the 12/13-bit resolution preserves signal fidelity for downstream QRS detection and pulse-oximetry math. The low-power pipeline keeps thermal dissipation low - important for patient-skin-adjacent wearables - and the small 40-pin LQFP fits compact wearable form factors.
Recomendado
Resumo dos produtos recomendados
Dados de referência de engenharia para CDK1307CILP40 — comparação, orientação de projeto e informações de conformidade.
Guia de seleção
Comparação com alternativas
| Parâmetro | Este produto | CDK1307AILP40 | CDK1307BILP40 | CDK1307DILP40 | CDK1308CILP40 |
|---|---|---|---|---|---|
| Package | LQFP-40 | LQFP-40 - same | LQFP-40 - same | LQFP-40 - same | LQFP-40 - same |
| Brand | MaxLinear | MaxLinear | MaxLinear | MaxLinear | MaxLinear |
| Resolution | 12/13-bit selectable | 12/13-bit selectable | 12/13-bit selectable | 12/13-bit selectable | 12/13-bit selectable |
| Sample Rate | 65 MSPS | 40 MSPS (-38%) | 20 MSPS (-69%) | 80 MSPS (+23%) | 80 MSPS (+23%) |
| Architecture | Pipelined CMOS | Pipelined CMOS | Pipelined CMOS | Pipelined CMOS | Pipelined CMOS |
| Supply Voltage | 3.3 V single | 3.3 V single | 3.3 V single | 3.3 V single | 3.3 V single |
| Internal Reference | Yes (1.2 V) | Yes (1.2 V) | Yes (1.2 V) | Yes (1.2 V) | Yes (1.2 V) |
| Output Interface | Parallel CMOS | Parallel CMOS | Parallel CMOS | Parallel CMOS | Parallel CMOS |
| Operating Temperature | -40 C to +85 C | -40 C to +85 C | -40 C to +85 C | -40 C to +85 C | -40 C to +85 C |
Principais diferenciais
- Pin-compatible 4-speed family (20/40/65/80 MSPS) (vs CDK1307AILP40 (40 MSPS grade))
- Ultra-low-power pipeline architecture (vs CDK1308CILP40 (next-gen 80 MSPS))
- Integrated reference and clock receiver (vs Generic 12-bit 65 MSPS ADC (e.g. AD9235 family))
Notas de projeto
Power the CDK1307CILP40 from a clean 3.3 V LDO or low-noise switching regulator post-filter. Place a 0.1 uF X7R ceramic + 10 uF tantalum bypass pair on each AVDD and DVDD pin, located within 3 mm of the pin. Keep the AVDD/DVDD traces short and isolated with a ferrite bead to prevent digital switching noise coupling back into the analog domain.
Maintain separate analog and digital ground planes that join only at the EP (exposed thermal pad) or at the AGND/DGND pin. Route the ENC+/ENC- differential clock with matched impedance and length matching (within 1 mm) to preserve duty cycle. Keep digital output traces (D0-D12) away from AIN and VREF traces to avoid digital coupling into the analog input.
Drive ENC+/ENC- with a low-jitter, low-phase-noise clock source - clock jitter directly degrades ADC SNR per the formula SNR = 6.02*ENOB + 1.76 + 20*log10(1/(2*pi*Fin* Tjitter)). For 32 MHz analog input and 12-bit performance, total jitter must stay below 5 ps RMS. Add a small RC filter at the clock pins if the source clock has overshoot or ringing.
Do not float the PDWN pin - tie it high (enabled) or low (standby) through a 10 kohm resistor. Do not exceed the maximum 3.6 V on AVDD/DVDD even during power-up transients. Sequence AVDD before DVDD if your design supports it, to avoid latch-up. Reference voltages (VREF) require their own bypass capacitor to AGND, sized per the datasheet (typically 0.1 uF in parallel with 10 uF).
Informações de conformidade
RoHS and lead-free per MaxLinear product page (2026-10-13). REACH status confirmed via MaxLinear declaration. AEC-Q100 not applicable - this is a commercial/industrial ADC; for automotive applications consult MaxLinear for the AEC-Q100-qualified product line.