SP3232EUEA-L/TR - 1 Mbps RS-232 Transceiver | MaxLinear
N.º da peça: SP3232EUEA-L/TR ✓ AtivoSP3232EUEA-L/TR Visão geral
An RS-232 transceiver is an interface IC that converts low-voltage digital logic levels into RS-232-compatible voltage levels and converts incoming RS-232 signals back into logic-compatible levels. Within the interface hierarchy, it is a physical-layer transceiver: logic ICs and microcontrollers generate the data, while the SP3232EUEA-L/TR handles voltage translation, noise margin, and line-driver capability. Two drivers and two receivers support two communication channels or paired full-duplex links.
The SP3232EUEA-L/TR operates at 3.3 V and supports a maximum data transmission rate of 1000 kbps. Its high-efficiency charge-pump supply requires only 0.1 µF capacitors for 3.3 V operation, reducing the external component count compared with conventional RS-232 designs that use larger pump capacitors. The integrated drivers and receivers also reduce board area while preserving separate transmit and receive paths.
The device is packaged in a 16-SSOP and supplied in tape-and-reel packaging for automated assembly. The -L/TR ordering form identifies the leaded 16-pin package and tape-and-reel shipment configuration. Its interface architecture is suitable for compact control panels, portable test equipment, configuration ports, and service interfaces where a legacy RS-232 connector must connect to a modern low-voltage UART.
Typical applications include notebook-style service connections, industrial controller diagnostics, laboratory instrument control, point-of-sale equipment, and embedded debug interfaces. The 1000 kbps capability allows the transceiver to handle substantially faster data than a conventional low-speed RS-232 port, provided that the UART, cable, connector, and system timing are designed for the selected baud rate.
When laying out the circuit, place the charge-pump capacitors and transceiver interface components close to their associated pins. Route the RS-232 driver and receiver traces away from sensitive clock, sensor, and analog inputs. Confirm the logic-side supply level, UART signal polarity, and connector pin assignment before power-up because a wiring error at the RS-232 connector can defeat otherwise correct logic-side communication.
This page organizes the manufacturer specifications, sourcing information, same-package family alternatives, and practical interface-layout guidance into one engineering-focused reference. It also distinguishes verified device facts from parameters that require confirmation against the complete manufacturer datasheet and the specific PCB implementation.
Alternativas drop-in para SP3232EUEA-L/TR — mesmo encapsulamento, compatível pino a pino. Peças de encapsulamento diferente que exigem retrabalho na PCB são excluídas.
Variantes desta série
Modelos da mesma série compatíveis como drop-in com SP3232EUEA-L/TR (mesmo formato e footprint) — diferindo em Package, Mounting Type, Charge-Pump Capacitor Requirement, Maximum Data Rate, Transceiver Configuration.
SP3223EUEA-L/TR
✅ Drop-In📋 Alternativa de referência (fora do catálogo)
SP3232EEA-L
✅ Drop-InConsulte o preço
Ver ficha técnica →SP3232ECY-L/TR
✅ Drop-InConsulte o preço
Ver ficha técnica →SP3232ECA-L/TR
✅ Drop-InConsulte o preço
Ver ficha técnica →SP3232EUEA-L/TR Especificações
| Product Type | RS-232 transceiver |
| Number of Drivers | 2 |
| Number of Receivers | 2 |
| Maximum Data Rate | 1000 kbps |
| Nominal Supply Voltage | 3.3 V |
| Supply Voltage Range | 3 V to 5.5 V |
| Charge-Pump Capacitor Requirement | 0.1 µF at 3.3 V operation |
| Encapsulamento | 16-SSOP |
| Contagem de pinos | 16 pins |
| Tipo de montagem | Surface mount |
| Packaging | Tape & Reel |
Guia de Configuração de Pinos do SP3232EUEA-L/TR 16-ssop
Configuração de pinos para SP3232EUEA-L/TR (pacote 16-ssop). A numeração dos pinos, funções e diagramas de conexão estão definidos no datasheet do fabricante. Consulte-o para o footprint exato e diretrizes de soldagem.
Nenhum dado detalhado de pinagem disponível para SP3232EUEA-L/TR.
Consulte a ficha técnica para a configuração completa dos pinos.
Aplicações típicas
SP3232EUEA-L/TR é adequado para 6 aplicaçãos: Portable Instrument Service Port, Industrial Controller Diagnostics, Laboratory Test Equipment Control, Point-of-Sale Terminal Interface, Embedded Configuration and Debug, Network Equipment Maintenance Console.
Portable Instrument Service Port
The SP3232EUEA-L/TR fits a portable instrument service port that must retain an RS-232 connector while using a modern 3.3 V controller. Its two drivers and two receivers support paired communication paths, while the 1000 kbps maximum data rate supports faster configuration and firmware-transfer procedures. The integrated charge pump needs only 0.1 µF capacitors in 3.3 V operation, reducing board area. Use the logic-side UART connections for firmware updates and the external driver and receiver pins for the DE-9 or equivalent RS-232 connector.
Recomendado
Industrial Controller Diagnostics
The SP3232EUEA-L/TR is appropriate for an industrial controller diagnostic connector where technicians connect a laptop or service terminal to a legacy RS-232 port. The 3 V to 5.5 V supply range supports compact embedded systems, and the 2/2 transceiver arrangement permits two communication paths. At up to 1000 kbps, it can handle status queries and configuration transfers efficiently, while the 16-SSOP package preserves PCB area. Keep the high-voltage RS-232 traces separated from sensitive analog and process-control signals.
Recomendado
Laboratory Test Equipment Control
The SP3232EUEA-L/TR can connect laboratory instruments and automated test systems through an RS-232 control port. Its maximum data rate of 1000 kbps supports command exchange and measurement-result transfers when paired with a suitably configured UART. Two drivers and two receivers provide flexibility for two ports or a full-duplex arrangement, and the small 16-SSOP footprint supports compact instrument electronics. Use shielded cable routing and protected connector placement to reduce noise and ESD exposure at the external interface.
Recomendado
Point-of-Sale Terminal Interface
The SP3232EUEA-L/TR supports a point-of-sale terminal or peripheral that exposes an RS-232 service or receipt interface. The 3.3 V operation is suitable for embedded systems with limited supply headroom, and the charge-pump implementation reduces the external capacitor size to 0.1 µF. Two drivers and two receivers allow more than one external channel when needed. Designers should isolate the logic and connector grounds according to the system grounding strategy and route transceiver outputs away from switching power and display signals.
Recomendado
Embedded Configuration and Debug
The SP3232EUEA-L/TR is useful for an embedded configuration port exposed through a legacy RS-232 connector. It translates between a 3.3 V UART and RS-232 levels while supporting operation at up to 1000 kbps, making it suitable for rapid boot configuration, diagnostics, and field-service access. The 16-SSOP package helps conserve PCB area, and the integrated charge pump simplifies the external power circuit. Add suitable connector-level ESD protection and define unambiguous boot-mode, ground, and signaling conventions.
Recomendado
Network Equipment Maintenance Console
The SP3232EUEA-L/TR can provide a maintenance-console connection in routers, switches, or other network appliances. Two drivers and two receivers support multiple RS-232 paths, and the 1000 kbps rate provides useful headroom for console output, configuration transfer, and management scripts. The device’s 3.3 V operation and compact 16-SSOP package suit space-constrained electronics. Place the external connector near the board edge, control ESD exposure, and maintain separation between RS-232 traces and high-speed Ethernet or switching-node circuitry.
Recomendado
Resumo dos produtos recomendados
Dados de referência de engenharia para SP3232EUEA-L/TR — comparação, orientação de projeto e informações de conformidade.
Guia de seleção
Comparação com alternativas
| Parâmetro | Este produto | SP3223EUEA-L/TR | SP3232EEA-L | SP3232ECY-L/TR | SP3232ECA-L/TR |
|---|---|---|---|---|---|
| Brand | MaxLinear | MaxLinear | MaxLinear | MaxLinear | MaxLinear |
| Package | 16-SSOP | 16-SSOP - same | 16-SSOP - same | 16-SSOP - same | 16-SSOP - same |
| Transceiver Configuration | 2 drivers / 2 receivers | 2 drivers / 2 receivers | 2 drivers / 2 receivers | 2 drivers / 2 receivers | 2 drivers / 2 receivers |
| Nominal Supply Voltage | 3.3 V | 3.3 V | 3.3 V | 3.3 V | 3.3 V |
| Maximum Data Rate | 1000 kbps | 1000 kbps | 1000 kbps | 1000 kbps | 1000 kbps |
| Charge-Pump Capacitor at 3.3 V | 0.1 µF | 0.1 µF | 0.1 µF | 0.1 µF | 0.1 µF |
| Pin Count | 16 pins | 16 pins | 16 pins | 16 pins | 16 pins |
Principais diferenciais
- Two-channel RS-232 interface in a compact 16-SSOP (vs SP232EET-L)
- High-speed operation for compact embedded equipment (vs SP3223EUEA-L/TR)
- Single-supply RS-232 operation (vs SP490EEN-L/TR)
Notas de projeto
Place the 0.1 µF charge-pump capacitors close to the pins designated by the manufacturer pin table, using short traces and an appropriate ground reference. The capacitors convert the single supply into the bipolar voltage required by the RS-232 drivers, so long or high-impedance capacitor connections can degrade charge-pump operation. Follow the datasheet layout pattern for capacitor placement and avoid routing those nodes beneath noisy switching stages.
Keep the external RS-232 driver and receiver traces away from UART clocks, sensor inputs, precision analog signals, and switching-converter loops. The RS-232 interface uses larger voltage swings than the logic side, so unintended capacitive or inductive coupling can create data errors. Route these nets as short as practical, keep the connector near the board edge, and provide a clear chassis or signal-ground return according to the equipment grounding architecture.
Do not assume that any RS-232 transceiver with the same channel count is pin-compatible. Verify the package drawing, pin numbering, charge-pump capacitor connections, driver and receiver pin assignments, and control functions against the manufacturer datasheet. Also distinguish logic-side TX and RX from external driver-output and receiver-input pins; reversing these connections can place an RS-232 voltage level directly onto a microcontroller input.
Use a connector and cable strategy that controls ESD and conducted noise at the exposed RS-232 port. Add the appropriate external protection only after checking its capacitance and clamping behavior, since excessive capacitance can slow edge transitions at the operating data rate. Maintain a controlled ground connection between the equipment and connected host, and avoid long unprotected stubs near the connector.
Informações de conformidade
The retrieved product and datasheet pages did not provide extractable compliance statements for this exact ordering code. Verify RoHS, REACH, lead-free, halogen-free, and conflict-mineral declarations with the manufacturer before regulatory submission.