AD582SD Обзор

The Analog Devices AD582SD is a single-channel sample-and-hold amplifier with 25 microsecond acquisition time, 3 V/µs slew rate, and a 14-pin ceramic dual-inline package. It combines a high-performance operational amplifier, a low-leakage analog switch, and a JFET integrating amplifier on one monolithic chip, while an external holding capacitor completes the sample-and-hold function.

A sample-and-hold amplifier is an analog signal-processing IC that captures an input voltage during a sampling interval and maintains that voltage for later processing. In the broader hierarchy, it belongs to the analog amplifier family and supports data acquisition, instrumentation, and closed-loop control systems. The AD582 is especially useful when a rapidly changing analog input must be converted into a stable level for an ADC, comparator, or control loop.

The AD582SD provides separate analog and digital ground connections, improving immunity to ground and switching transients. Its low-leakage analog switch helps preserve the held voltage between acquisition intervals, while the integrated JFET amplifier provides high input impedance. The 3 V/µs slew rate supports acquisition of changing input signals, and the 25 µs acquisition specification gives designers a defined settling interval to work with.

Internally, the operational amplifier provides the active signal path, the analog switch controls acquisition versus hold state, and the JFET integrating amplifier isolates the holding capacitor. These elements are fabricated on a single monolithic chip. An external holding capacitor remains essential, and its capacitance, dielectric type, leakage, and PCB placement directly influence acquisition accuracy, droop, noise, and achievable resolution.

Typical uses include precision data-acquisition systems, laboratory instrumentation, industrial control equipment, analog measurement interfaces, and sample-and-hold stages preceding analog-to-digital conversion. The AD582 can also serve in pulse-width measurement, control loops, and analog signal conditioning where holding a variable waveform level simplifies downstream processing.

PCB design should keep the holding-capacitor connection short, use a clean analog-ground return, and isolate sensitive input routing from switching nodes. Because external capacitor behavior strongly influences accuracy, follow the capacitor selection and layout guidance in the manufacturer datasheet rather than treating the acquisition time as independent of the complete circuit.

This page combines the manufacturer's architecture description with verified package and timing information, practical capacitor-layout guidance, lifecycle considerations, and a strict review of same-footprint alternatives. It is intended to help engineers determine whether the AD582SD fits a legacy precision-analog design before requesting sourcing and assembly support.

Аналоги без доработки для AD582SD — тот же корпус, pin-to-pin совместимость. Компоненты в других корпусах, требующие переработки PCB, исключены.

Варианты в этой серии

Модели той же серии, совместимые без доработки с AD582SD (тот же форм-фактор и посадочное место) — отличается по Holding Capacitor, Package, Product Type, Acquisition Time, Mounting Type.

Analog Devices
Holding Capacitor: External holding capacitor required
Package: 14-CDIP, 0.300 inch (7.62 mm) body width
Product Type: 1 circuit sample-and-hold amplifier
Сравнить с AD582SD →
Analog Devices
Holding Capacitor: External
Package: TO-100-10
Product Type: Sample-and-hold amplifier
Сравнить с AD582SD →

AD582KD

✅ Прямая замена
Analog Devices
📦 14-CDIP (0.300 in, 7.62 mm)
1 circuit sample-and-hold amplifier · 1 circuit · 14-CDIP, 0.300 inch (7.62 mm) body width · 3 V/us · Operational amplifier, low-leakage analog switch, and JFET integrating amplifier on one monolithic chip · Separate analog and digital grounds · External holding capacitor required · Versions available compliant with MIL-STD-883

Уточнить цену

Открыть даташит →

AD582KH

✅ Прямая замена
Analog Devices
📦 14-CDIP (0.300 in, 7.62 mm)
Sample-and-hold amplifier · 1 channel · 1 amplifier · 1.5 MHz · 6 us · 25 us · 2 mV · 500 ns

Уточнить цену

Открыть даташит →

AD582SD Максимальные параметры и электрические характеристики

Product Type Single-channel sample-and-hold amplifier
Number of Circuits 1 circuit
Acquisition Time 25 µs
Slew Rate 3 V/µs
Architecture Operational amplifier, low-leakage analog switch, and JFET integrating amplifier on one monolithic chip
Holding Capacitor External holding capacitor
Ground Configuration Separate analog and digital grounds
Корпус 14-CDIP, 0.300 in (7.62 mm) body width
Число выводов 14 pins
Тип монтажа Through-hole ceramic dual-inline package
Shipping Package Tube
MIL-STD-883 Availability AD582 family versions are compliant; exact AD582SD qualification status requires confirmation

Руководство по цоколевке AD582SD в корпусе tube

Цоколевка для AD582SD (корпус tube). Этот аналоговый компонент имеет выводы входа, выхода и питания. Обратитесь к техническому описанию производителя для конфигураций выводов балансировки нуля, коррекции и разрешения. Идеально подходит для схем обработки сигналов и усилителей.

Схема цоколевки корпуса tube для AD582SD

Нет подробных данных о распиновке для AD582SD.

Обратитесь к даташиту для полной конфигурации выводов.

Типичное применение

AD582SD подходит для 6 применениеs: Precision ADC Front Ends, Laboratory Measurement Instruments, Industrial Control Signal Conditioning, Pulse and Transient Amplitude Capture, Analog Feedback and Control Loops, Legacy Data-Acquisition Equipment.

🖥️

Precision ADC Front Ends

The AD582SD is applicable when an ADC input changes too quickly for direct conversion and must first be held at a stable level. Its 25 µs acquisition specification provides the timing reference for capturing the input through the low-leakage analog switch, while the JFET integrating amplifier helps prevent the external holding capacitor from discharging rapidly. The circuit can feed a downstream converter through a carefully designed hold network. Engineers should verify input range, supply rails, logic-control polarity, capacitor charge-back, and acquisition settling in the official data sheet. The 3 V/µs slew rate is relevant when the captured waveform contains meaningful slope, but the complete acquisition time depends on capacitor value and leakage.

🧩

Laboratory Measurement Instruments

The AD582SD can stabilize a variable analog measurement before a meter, display, or control block processes the value. The 25 µs acquisition interval is useful for waveforms whose amplitude must be captured at a defined instant, while the separate analog and digital ground connections help isolate the signal path from switching transients. Its integrated operational amplifier, analog switch, and JFET amplifier reduce the number of discrete active components required around the holding capacitor. For laboratory instrumentation, capacitor dielectric leakage and board contamination become especially important during long hold periods. Confirm the exact temperature grade, supply limits, and qualification status before using the AD582SD in new production instruments.

🏭

Industrial Control Signal Conditioning

The AD582SD can convert a changing control signal into a held level for comparison or process-control decisions. Its 3 V/µs slew rate and 25 µs acquisition specification allow the input to be captured within a defined sampling interval, and the JFET integrating amplifier offers a high-impedance holding path. This arrangement is particularly relevant where a controller must respond to the peak, average, or selected level of an analog waveform rather than its instantaneous value. Because industrial environments can contain switching transients, the separate analog and digital ground pins should be connected according to the manufacturer circuit. Validate the complete input and supply ranges, capacitor selection, and timing budget before integrating the device.

📺

Pulse and Transient Amplitude Capture

The AD582SD can capture a changing pulse or transient amplitude at the command-controlled sampling instant. Its 25 µs acquisition time and 3 V/µs slew rate are the principal timing values to compare against the pulse shape and trigger delay. The low-leakage analog switch supports the hold interval, and the external capacitor determines whether the captured voltage remains accurate for the required observation period. Designers should include acquisition time in the overall trigger-to-sample budget and account for the time required to settle the output after switching from sample to hold. A shorter acquisition interval, faster slew behavior, or lower-leakage capacitor may be necessary for demanding pulse measurements.

⚡

Analog Feedback and Control Loops

The AD582SD can hold an analog error or command level when a feedback system requires a stable value between update events. The monolithic combination of an operational amplifier, low-leakage switch, and JFET integrating amplifier supports a compact analog-hold stage, while the 3 V/µs slew rate helps the circuit track changing inputs during acquisition. The 25 µs acquisition interval must remain compatible with the control-loop update period. Long hold times can expose capacitor leakage and parasitic leakage paths, so clean PCB assembly and guarding are important. Use the manufacturer application information to determine whether the device's aging, droop, and offset characteristics satisfy the loop's stability and accuracy requirements.

🔧

Legacy Data-Acquisition Equipment

The AD582SD is relevant to repairing or extending legacy data-acquisition equipment whose original design used the AD582 family. The 14-CDIP package and established 25 µs acquisition architecture allow an existing board-level architecture to be maintained when the exact suffix is confirmed. Its monolithic active circuitry reduces the complexity of substituting the sample-and-hold function into an older analog signal chain. However, the external holding capacitor and surrounding timing network remain design-critical: changing capacitor value or dielectric can alter acquisition, droop, offset, and noise behavior. Compare the replacement schematic, pin functions, supply requirements, and qualification markings with the original component before energizing the assembly.

What is the AD582SD?
The AD582SD is a single-channel sample-and-hold amplifier with a 25 µs acquisition time, a 3 V/µs slew rate, and a 14-pin ceramic DIP package. According to the Analog Devices AD582 datasheet, it combines a high-performance operational amplifier, a low-leakage analog switch, and a JFET integrating amplifier on one monolithic chip. An external holding capacitor completes the sampling function and is essential to the final circuit performance.
Where can I download the AD582SD datasheet PDF?
The official AD582SD datasheet is available from Analog Devices through the AD582 data-sheet link on this page. The manufacturer document describes the internal operational amplifier, analog switch, and JFET integrating amplifier, along with external holding-capacitor requirements and application details. Use the manufacturer PDF for electrical characteristics, pin descriptions, test circuits, and cautions before adapting the circuit.
Where can I find the AD582SD pinout?
The AD582SD pin assignment should be taken from the pin-description table and package drawing in the official Analog Devices AD582 data sheet. The device is supplied in a 14-pin ceramic DIP, so the package diagram contains 14 numbered positions. Do not assign PCB nets from a generic sample-and-hold pinout because logic-control polarity, offset adjustment, and analog or digital ground locations are device-specific.
What are the key specifications of AD582SD that engineers should know?
The AD582SD combines a 25 µs acquisition time with a 3 V/µs slew rate in a 14-CDIP package. According to the Analog Devices AD582 data sheet, its monolithic implementation contains an operational amplifier, low-leakage analog switch, and JFET integrating amplifier. Separate analog and digital grounds improve transient immunity, while the external holding capacitor determines practical droop, noise, and acquisition behavior.
How long does the AD582SD take to acquire a signal?
The specified acquisition time for the AD582SD is 25 µs. This is the interval available to charge the external holding capacitor and acquire the input voltage accurately enough for the intended downstream circuit. Actual system settling also depends on input amplitude, capacitor value and dielectric, switch resistance, leakage, and PCB layout. Consult the manufacturer test circuit and recommended capacitor guidance when defining a system timing budget.
What external components does the AD582SD require?
The AD582SD requires an external holding capacitor to complete its sample-and-hold function. The capacitor is charged through the internal analog switch during acquisition and then holds the captured voltage while the JFET integrating amplifier isolates the output. According to the Analog Devices AD582 data sheet, capacitor leakage and dielectric behavior affect hold accuracy. Select the value and type using the manufacturer's recommended circuit and application guidance.
Where can I buy the AD582SD online?
Use the Request a Quote form on this page to request the AD582SD and discuss quantity, tube packaging, assembly requirements, and current availability. Because this is a mature legacy device, procurement status can vary by lot and package variant. The form lets the buyer request a current quotation without relying on an outdated catalog listing or assuming that an inactive distributor page reflects live inventory.
What is the price of the AD582SD?
The current AD582SD quotation is generated through the Request a Quote form on this page. Pricing for a legacy ceramic-DIP sample-and-hold amplifier can depend on quantity, remaining lot traceability, test or inspection requirements, and packaging. Submit the desired quantity and any assembly or traceability needs so the quotation can reflect the exact AD582SD configuration rather than a generic sample-and-hold amplifier.
What is the lead time for the AD582SD?
Request the current AD582SD lead time and minimum order quantity through the Request a Quote form on this page. Lead time for an obsolete or mature device depends on available inventory, lot traceability, and whether the assembly requires inspection, screening, or a programmed configuration. Provide the required quantity and target delivery date so sourcing can confirm the most relevant schedule.
Is the AD582SD in stock?
Current AD582SD inventory should be confirmed through the Request a Quote form on this page. The AD582 is a mature product family, and a distributor category page or archived stock record does not guarantee that the exact AD582SD suffix is immediately available. State the required quantity, tube-packaging preference, and traceability requirements when requesting a quotation and current availability confirmation.
What is the difference between AD582SD and AD582KD?
The AD582SD and AD582KD belong to the same AD582 sample-and-hold amplifier family, and the listed comparison identifies both as one-channel devices. The verified family specifications give a 25 µs acquisition time and a 3 V/µs slew rate, so the measurable timing difference shown here is 0 µs and 0 V/µs. Their ordering suffixes must still be checked for temperature grade, package construction, and qualification before substitution.
AD582SD vs AD582KH - which is better for a legacy instrument?
Choose the AD582SD or AD582KH according to the original instrument schematic, bill of materials, and environmental qualification requirements rather than timing alone. Both are AD582-family one-channel sample-and-hold devices with a 25 µs acquisition time and 3 V/µs slew rate, a 0 µs and 0 V/µs timing difference. The critical selection point is exact suffix-level qualification and package compatibility, which should be verified in the manufacturer documentation.
When should I choose the AD582SD over another AD582-family device?
Choose the AD582SD when the original design specifies that exact suffix and requires a 14-CDIP sample-and-hold stage with 25 µs acquisition. The AD582 family is suited to precision measurement and signal conditioning because it provides a low-leakage switch and JFET integrating amplifier, but this legacy architecture should not be selected for new designs without checking lifecycle, availability, and competing modern solutions.
Is the AD582SD suitable for an ADC front end?
The AD582SD can be suitable for an ADC front end when the required sampling interval accommodates its 25 µs acquisition time and the selected external capacitor meets the required resolution and droop limits. Its low-leakage switch and JFET integrating amplifier help preserve the sampled level. Confirm input range, supply requirements, logic-control polarity, settling, and charge-back behavior against the official data sheet before implementation.
What can replace the AD582SD?
The closest documented same-family candidates are the AD582KD and AD582KH, but a true drop-in substitution must preserve the 14-pin footprint, pin functions, control polarity, supply arrangement, acquisition behavior, and environmental qualification. The verified comparison confirms that all three are AD582 one-channel sample-and-hold devices with 25 µs acquisition and a 3 V/µs slew rate. Validate the exact suffix and manufacturer data sheet before replacing AD582SD in production equipment.
Is there a drop-in replacement for the AD582SD from another manufacturer?
No verified cross-brand drop-in replacement for the AD582SD was identified. A functional sample-and-hold amplifier from another manufacturer is not automatically pin-compatible, because control polarity, offset-null arrangements, ground connections, acquisition timing, and supply rails can differ. If sourcing an AD582KD or AD582KH, use the Request a Quote form on this page and request confirmation of exact-package and qualification details.

Справочные инженерные данные для AD582SD — сравнение, рекомендации по проектированию и информация о соответствии.

Руководство по выбору

Choose the AD582SD when maintaining an existing system that specifically calls for that suffix, a 14-CDIP footprint, a 25 µs acquisition stage, and the documented AD582 monolithic sample-and-hold architecture. AD582KD may be considered when its suffix-level temperature, package, qualification, and sourcing conditions are acceptable because its verified acquisition and slew timing are the same. AD582KH is another same-family candidate when its qualification and environmental requirements satisfy the equipment. No cross-brand drop-in replacement was verified; a modern sample-and-hold amplifier should be treated as a redesign unless its pinout, supply rails, control polarity, timing, accuracy, and output behavior are proven equivalent. For new designs, assess lifecycle availability and contemporary data-acquisition alternatives before committing to this mature architecture.

Сравнение с аналогами

Параметр Этот товар AD582KD AD582KH
Package 14-CDIP (0.300 in, 7.62 mm) 14-CDIP footprint; exact ceramic construction requires suffix-level verification 14-CDIP footprint; exact ceramic construction requires suffix-level verification
Brand Analog Devices Analog Devices Analog Devices
Product Type Sample-and-hold amplifier Sample-and-hold amplifier Sample-and-hold amplifier
Number of Channels 1 channel 1 channel 1 channel
Acquisition Time 25 µs 25 µs 25 µs
Slew Rate 3 V/µs 3 V/µs 3 V/µs
Internal Architecture Operational amplifier, low-leakage analog switch, and JFET integrating amplifier AD582-family sample-and-hold architecture AD582-family sample-and-hold architecture
Ground Arrangement Separate analog and digital grounds Separate analog and digital grounds Separate analog and digital grounds
External Holding Capacitor Required Required Required

Ключевые отличия

  • Integrated complete sample-and-hold signal path (против AD582KD)
  • Identical verified acquisition and slew timing (против AD582KH)
  • Separate analog and digital grounding (против AD582KD)
  • Established 14-CDIP legacy integration (против AD582KH)

Заметки по проектированию

Do not assume that the 25 µs acquisition specification is independent of the external holding capacitor. The capacitor value, dielectric, leakage, switch resistance, source impedance, and PCB leakage all influence settling and hold accuracy. Reproduce the manufacturer test circuit first, then verify temperature and supply extremes with the intended capacitor and board construction. A substitute capacitor with the same capacitance can still change acquisition time and droop.

Place the external holding capacitor and the AD582SD as close together as practical, and keep the connection between them short and shielded from nearby switching nodes. Route sensitive analog inputs away from digital return currents and clock or pulse edges. Separate analog and digital ground connections according to the manufacturer application circuit; joining them at the wrong point can allow ground and switching transients to appear directly on the held signal.

Include switch transition, acquisition settling, and hold-mode settling in the system timing budget rather than treating acquisition time as the complete sample-to-output delay. The specified 3 V/µs slew rate helps determine how quickly the amplifier can move through a required input change, but the output also depends on the held voltage and external capacitance. Test acquisition accuracy with the intended source impedance and downstream load, and measure droop over the longest required hold interval.

For maintenance and redesign work, compare the complete ordering suffix, ceramic-package construction, temperature range, qualification markings, and pin functions before replacing AD582SD with AD582KD or AD582KH. Matching the 14-pin outline and 25 µs acquisition specification is necessary but does not by itself prove regulatory or environmental equivalence. Review the manufacturer documents and inspect the original assembly markings before energizing the replacement.

Информация о соответствии

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
Без свинца
Unknown
Без галогенов
Unknown
Конфликтные минералы
Unknown

Analog Devices states that versions of the AD582 family are available compliant with MIL-STD-883, but the exact AD582SD qualification status must be confirmed from the ordering guide and current military-products documentation. RoHS, REACH, lead-free, halogen-free, and conflict-minerals status are not stated for this exact suffix in the product materials reviewed.

Данные проверены: 2026-11-18 — данные проверены и курируются командой компонентной инженерии XAIPART

Похожие запросы

ad582 nsdl AD582SD datasheet AD582SD datasheet pdf AD582SD pinout AD582SD specifications AD582SD acquisition time AD582SD slew rate AD582SD equivalent AD582SD replacement AD582SD vs AD582KD AD582SD vs AD582KH AD582SD 14-CDIP AD582SD sample and hold AD582SD price AD582SD stock

Связанные компоненты & термины

Analog Devices AD582SD AD582KD AD582KH sample-and-hold amplifier analog amplifier signal-processing IC data acquisition precision measurement operational amplifier low-leakage analog switch JFET integrating amplifier external holding capacitor acquisition time slew rate hold droop separate analog ground separate digital ground 14-CDIP ceramic dual-inline package through-hole package monolithic IC MIL-STD-883 switching transients instrumentation
Быстрый запрос цены (RFQ)
Заполните все данные — наша команда продаж ответит в течение 24 часов
Артикул Производитель Корпус QTY Целевая цена Итого
✓
Запрос цены отправлен!

Мы ответим на ваш email в течение 24 часов

1
RFQ отправлен
2
Предложение получено
3
Заказ оформлен
4
Оплата
5
Отправлено
6
Доставлено
Просмотреть детали RFQ