AD582SD - 25us Sample-and-Hold Amplifier | Analog Devices
부품 번호: AD582SD ✗ 단종AD582SD 개요
A sample-and-hold amplifier is an analog signal-processing IC that captures an input voltage during a sampling interval and maintains that voltage for later processing. In the broader hierarchy, it belongs to the analog amplifier family and supports data acquisition, instrumentation, and closed-loop control systems. The AD582 is especially useful when a rapidly changing analog input must be converted into a stable level for an ADC, comparator, or control loop.
The AD582SD provides separate analog and digital ground connections, improving immunity to ground and switching transients. Its low-leakage analog switch helps preserve the held voltage between acquisition intervals, while the integrated JFET amplifier provides high input impedance. The 3 V/µs slew rate supports acquisition of changing input signals, and the 25 µs acquisition specification gives designers a defined settling interval to work with.
Internally, the operational amplifier provides the active signal path, the analog switch controls acquisition versus hold state, and the JFET integrating amplifier isolates the holding capacitor. These elements are fabricated on a single monolithic chip. An external holding capacitor remains essential, and its capacitance, dielectric type, leakage, and PCB placement directly influence acquisition accuracy, droop, noise, and achievable resolution.
Typical uses include precision data-acquisition systems, laboratory instrumentation, industrial control equipment, analog measurement interfaces, and sample-and-hold stages preceding analog-to-digital conversion. The AD582 can also serve in pulse-width measurement, control loops, and analog signal conditioning where holding a variable waveform level simplifies downstream processing.
PCB design should keep the holding-capacitor connection short, use a clean analog-ground return, and isolate sensitive input routing from switching nodes. Because external capacitor behavior strongly influences accuracy, follow the capacitor selection and layout guidance in the manufacturer datasheet rather than treating the acquisition time as independent of the complete circuit.
This page combines the manufacturer's architecture description with verified package and timing information, practical capacitor-layout guidance, lifecycle considerations, and a strict review of same-footprint alternatives. It is intended to help engineers determine whether the AD582SD fits a legacy precision-analog design before requesting sourcing and assembly support.
드롭인 대체품: AD582SD — 동일 패키지, 핀 호환. PCB 재작업이 필요한 다른 패키지 부품은 제외됩니다.
이 시리즈의 변형
다음과 드롭인 호환되는 동일 시리즈 모델: AD582SD (동일 폼 팩터 및 풋프린트) — 차이점: Holding Capacitor, Package, Product Type, Acquisition Time, Mounting Type.
AD582KD
✅ 드롭인가격 문의
데이터시트 보기 →AD582KH
✅ 드롭인가격 문의
데이터시트 보기 →AD582SD 최대 정격 & 전기적 특성
| Product Type | Single-channel sample-and-hold amplifier |
| Number of Circuits | 1 circuit |
| Acquisition Time | 25 µs |
| Slew Rate | 3 V/µs |
| Architecture | Operational amplifier, low-leakage analog switch, and JFET integrating amplifier on one monolithic chip |
| Holding Capacitor | External holding capacitor |
| Ground Configuration | Separate analog and digital grounds |
| 패키지 | 14-CDIP, 0.300 in (7.62 mm) body width |
| 핀 수 | 14 pins |
| 실장 유형 | Through-hole ceramic dual-inline package |
| Shipping Package | Tube |
| MIL-STD-883 Availability | AD582 family versions are compliant; exact AD582SD qualification status requires confirmation |
AD582SD tube 핀 구성 가이드
AD582SD(tube 패키지)의 핀 구성입니다. 이 아날로그 부품에는 입력, 출력, 전원 공급 핀이 있습니다. 오프셋 널, 보상, 인에이블 핀 구성은 제조사 데이터시트를 참조하십시오. 신호 컨디셔닝 및 증폭기 회로에 이상적입니다.
다음에 대한 상세 핀아웃 데이터 없음: AD582SD.
다음을 참조하십시오: 데이터시트 전체 핀 구성은 다음을 참조하십시오.
일반적인 애플리케이션
AD582SD 적합 용도: 6 애플리케이션s: Precision ADC Front Ends, Laboratory Measurement Instruments, Industrial Control Signal Conditioning, Pulse and Transient Amplitude Capture, Analog Feedback and Control Loops, Legacy Data-Acquisition Equipment.
Precision ADC Front Ends
The AD582SD is applicable when an ADC input changes too quickly for direct conversion and must first be held at a stable level. Its 25 µs acquisition specification provides the timing reference for capturing the input through the low-leakage analog switch, while the JFET integrating amplifier helps prevent the external holding capacitor from discharging rapidly. The circuit can feed a downstream converter through a carefully designed hold network. Engineers should verify input range, supply rails, logic-control polarity, capacitor charge-back, and acquisition settling in the official data sheet. The 3 V/µs slew rate is relevant when the captured waveform contains meaningful slope, but the complete acquisition time depends on capacitor value and leakage.
추천
Laboratory Measurement Instruments
The AD582SD can stabilize a variable analog measurement before a meter, display, or control block processes the value. The 25 µs acquisition interval is useful for waveforms whose amplitude must be captured at a defined instant, while the separate analog and digital ground connections help isolate the signal path from switching transients. Its integrated operational amplifier, analog switch, and JFET amplifier reduce the number of discrete active components required around the holding capacitor. For laboratory instrumentation, capacitor dielectric leakage and board contamination become especially important during long hold periods. Confirm the exact temperature grade, supply limits, and qualification status before using the AD582SD in new production instruments.
추천
Industrial Control Signal Conditioning
The AD582SD can convert a changing control signal into a held level for comparison or process-control decisions. Its 3 V/µs slew rate and 25 µs acquisition specification allow the input to be captured within a defined sampling interval, and the JFET integrating amplifier offers a high-impedance holding path. This arrangement is particularly relevant where a controller must respond to the peak, average, or selected level of an analog waveform rather than its instantaneous value. Because industrial environments can contain switching transients, the separate analog and digital ground pins should be connected according to the manufacturer circuit. Validate the complete input and supply ranges, capacitor selection, and timing budget before integrating the device.
추천
Pulse and Transient Amplitude Capture
The AD582SD can capture a changing pulse or transient amplitude at the command-controlled sampling instant. Its 25 µs acquisition time and 3 V/µs slew rate are the principal timing values to compare against the pulse shape and trigger delay. The low-leakage analog switch supports the hold interval, and the external capacitor determines whether the captured voltage remains accurate for the required observation period. Designers should include acquisition time in the overall trigger-to-sample budget and account for the time required to settle the output after switching from sample to hold. A shorter acquisition interval, faster slew behavior, or lower-leakage capacitor may be necessary for demanding pulse measurements.
추천
Analog Feedback and Control Loops
The AD582SD can hold an analog error or command level when a feedback system requires a stable value between update events. The monolithic combination of an operational amplifier, low-leakage switch, and JFET integrating amplifier supports a compact analog-hold stage, while the 3 V/µs slew rate helps the circuit track changing inputs during acquisition. The 25 µs acquisition interval must remain compatible with the control-loop update period. Long hold times can expose capacitor leakage and parasitic leakage paths, so clean PCB assembly and guarding are important. Use the manufacturer application information to determine whether the device's aging, droop, and offset characteristics satisfy the loop's stability and accuracy requirements.
추천
Legacy Data-Acquisition Equipment
The AD582SD is relevant to repairing or extending legacy data-acquisition equipment whose original design used the AD582 family. The 14-CDIP package and established 25 µs acquisition architecture allow an existing board-level architecture to be maintained when the exact suffix is confirmed. Its monolithic active circuitry reduces the complexity of substituting the sample-and-hold function into an older analog signal chain. However, the external holding capacitor and surrounding timing network remain design-critical: changing capacitor value or dielectric can alter acquisition, droop, offset, and noise behavior. Compare the replacement schematic, pin functions, supply requirements, and qualification markings with the original component before energizing the assembly.
추천
추천 제품 요약
엔지니어링 참조 데이터: AD582SD — 비교, 설계 지침 및 규정 준수 정보.
선택 가이드
대체품과의 비교
| 파라미터 | 이 제품 | AD582KD | AD582KH |
|---|---|---|---|
| Package | 14-CDIP (0.300 in, 7.62 mm) | 14-CDIP footprint; exact ceramic construction requires suffix-level verification | 14-CDIP footprint; exact ceramic construction requires suffix-level verification |
| Brand | Analog Devices | Analog Devices | Analog Devices |
| Product Type | Sample-and-hold amplifier | Sample-and-hold amplifier | Sample-and-hold amplifier |
| Number of Channels | 1 channel | 1 channel | 1 channel |
| Acquisition Time | 25 µs | 25 µs | 25 µs |
| Slew Rate | 3 V/µs | 3 V/µs | 3 V/µs |
| Internal Architecture | Operational amplifier, low-leakage analog switch, and JFET integrating amplifier | AD582-family sample-and-hold architecture | AD582-family sample-and-hold architecture |
| Ground Arrangement | Separate analog and digital grounds | Separate analog and digital grounds | Separate analog and digital grounds |
| External Holding Capacitor | Required | Required | Required |
주요 차별점
- Integrated complete sample-and-hold signal path (vs AD582KD)
- Identical verified acquisition and slew timing (vs AD582KH)
- Separate analog and digital grounding (vs AD582KD)
- Established 14-CDIP legacy integration (vs AD582KH)
설계 노트
Do not assume that the 25 µs acquisition specification is independent of the external holding capacitor. The capacitor value, dielectric, leakage, switch resistance, source impedance, and PCB leakage all influence settling and hold accuracy. Reproduce the manufacturer test circuit first, then verify temperature and supply extremes with the intended capacitor and board construction. A substitute capacitor with the same capacitance can still change acquisition time and droop.
Place the external holding capacitor and the AD582SD as close together as practical, and keep the connection between them short and shielded from nearby switching nodes. Route sensitive analog inputs away from digital return currents and clock or pulse edges. Separate analog and digital ground connections according to the manufacturer application circuit; joining them at the wrong point can allow ground and switching transients to appear directly on the held signal.
Include switch transition, acquisition settling, and hold-mode settling in the system timing budget rather than treating acquisition time as the complete sample-to-output delay. The specified 3 V/µs slew rate helps determine how quickly the amplifier can move through a required input change, but the output also depends on the held voltage and external capacitance. Test acquisition accuracy with the intended source impedance and downstream load, and measure droop over the longest required hold interval.
For maintenance and redesign work, compare the complete ordering suffix, ceramic-package construction, temperature range, qualification markings, and pin functions before replacing AD582SD with AD582KD or AD582KH. Matching the 14-pin outline and 25 µs acquisition specification is necessary but does not by itself prove regulatory or environmental equivalence. Review the manufacturer documents and inspect the original assembly markings before energizing the replacement.
규정 준수 정보
Analog Devices states that versions of the AD582 family are available compliant with MIL-STD-883, but the exact AD582SD qualification status must be confirmed from the ordering guide and current military-products documentation. RoHS, REACH, lead-free, halogen-free, and conflict-minerals status are not stated for this exact suffix in the product materials reviewed.