AD582SD - 25us Sample-and-Hold Amplifier | Analog Devices
MPN: AD582SD ✗ 停產AD582SD 概覽
A sample-and-hold amplifier is an analog signal-processing IC that captures an input voltage during a sampling interval and maintains that voltage for later processing. In the broader hierarchy, it belongs to the analog amplifier family and supports data acquisition, instrumentation, and closed-loop control systems. The AD582 is especially useful when a rapidly changing analog input must be converted into a stable level for an ADC, comparator, or control loop.
The AD582SD provides separate analog and digital ground connections, improving immunity to ground and switching transients. Its low-leakage analog switch helps preserve the held voltage between acquisition intervals, while the integrated JFET amplifier provides high input impedance. The 3 V/µs slew rate supports acquisition of changing input signals, and the 25 µs acquisition specification gives designers a defined settling interval to work with.
Internally, the operational amplifier provides the active signal path, the analog switch controls acquisition versus hold state, and the JFET integrating amplifier isolates the holding capacitor. These elements are fabricated on a single monolithic chip. An external holding capacitor remains essential, and its capacitance, dielectric type, leakage, and PCB placement directly influence acquisition accuracy, droop, noise, and achievable resolution.
Typical uses include precision data-acquisition systems, laboratory instrumentation, industrial control equipment, analog measurement interfaces, and sample-and-hold stages preceding analog-to-digital conversion. The AD582 can also serve in pulse-width measurement, control loops, and analog signal conditioning where holding a variable waveform level simplifies downstream processing.
PCB design should keep the holding-capacitor connection short, use a clean analog-ground return, and isolate sensitive input routing from switching nodes. Because external capacitor behavior strongly influences accuracy, follow the capacitor selection and layout guidance in the manufacturer datasheet rather than treating the acquisition time as independent of the complete circuit.
This page combines the manufacturer's architecture description with verified package and timing information, practical capacitor-layout guidance, lifecycle considerations, and a strict review of same-footprint alternatives. It is intended to help engineers determine whether the AD582SD fits a legacy precision-analog design before requesting sourcing and assembly support.
直接替換替代品,適用於 AD582SD — 相同封裝,腳位對腳位相容。需重新設計 PCB 的不同封裝零件不列入。
此系列的變體
與下列產品可直接替換的同系列型號: AD582SD (相同外形與佔位) — 差異在於 Holding Capacitor, Package, Product Type, Acquisition Time, Mounting Type.
AD582KD
✅ 直接替換聯絡詢價
查看資料表 →AD582SD 最大額定值與電氣特性
| Product Type | Single-channel sample-and-hold amplifier |
| Number of Circuits | 1 circuit |
| Acquisition Time | 25 µs |
| Slew Rate | 3 V/µs |
| Architecture | Operational amplifier, low-leakage analog switch, and JFET integrating amplifier on one monolithic chip |
| Holding Capacitor | External holding capacitor |
| Ground Configuration | Separate analog and digital grounds |
| 封裝 | 14-CDIP, 0.300 in (7.62 mm) body width |
| 腳位數 | 14 pins |
| 安裝類型 | Through-hole ceramic dual-inline package |
| Shipping Package | Tube |
| MIL-STD-883 Availability | AD582 family versions are compliant; exact AD582SD qualification status requires confirmation |
AD582SD tube 腳位配置指南
AD582SD(tube 封裝)的腳位配置。 此類比元件具有輸入、輸出與電源腳位。偏移歸零、補償與致能腳位配置請參閱製造商資料表。適用於訊號調理與放大器電路。
無詳細腳位定義資料: AD582SD.
請參閱 資料表 以查看完整腳位配置。
典型應用
AD582SD 適用於 6 應用s: Precision ADC Front Ends, Laboratory Measurement Instruments, Industrial Control Signal Conditioning, Pulse and Transient Amplitude Capture, Analog Feedback and Control Loops, Legacy Data-Acquisition Equipment.
Precision ADC Front Ends
The AD582SD is applicable when an ADC input changes too quickly for direct conversion and must first be held at a stable level. Its 25 µs acquisition specification provides the timing reference for capturing the input through the low-leakage analog switch, while the JFET integrating amplifier helps prevent the external holding capacitor from discharging rapidly. The circuit can feed a downstream converter through a carefully designed hold network. Engineers should verify input range, supply rails, logic-control polarity, capacitor charge-back, and acquisition settling in the official data sheet. The 3 V/µs slew rate is relevant when the captured waveform contains meaningful slope, but the complete acquisition time depends on capacitor value and leakage.
推薦
Laboratory Measurement Instruments
The AD582SD can stabilize a variable analog measurement before a meter, display, or control block processes the value. The 25 µs acquisition interval is useful for waveforms whose amplitude must be captured at a defined instant, while the separate analog and digital ground connections help isolate the signal path from switching transients. Its integrated operational amplifier, analog switch, and JFET amplifier reduce the number of discrete active components required around the holding capacitor. For laboratory instrumentation, capacitor dielectric leakage and board contamination become especially important during long hold periods. Confirm the exact temperature grade, supply limits, and qualification status before using the AD582SD in new production instruments.
推薦
Industrial Control Signal Conditioning
The AD582SD can convert a changing control signal into a held level for comparison or process-control decisions. Its 3 V/µs slew rate and 25 µs acquisition specification allow the input to be captured within a defined sampling interval, and the JFET integrating amplifier offers a high-impedance holding path. This arrangement is particularly relevant where a controller must respond to the peak, average, or selected level of an analog waveform rather than its instantaneous value. Because industrial environments can contain switching transients, the separate analog and digital ground pins should be connected according to the manufacturer circuit. Validate the complete input and supply ranges, capacitor selection, and timing budget before integrating the device.
推薦
Pulse and Transient Amplitude Capture
The AD582SD can capture a changing pulse or transient amplitude at the command-controlled sampling instant. Its 25 µs acquisition time and 3 V/µs slew rate are the principal timing values to compare against the pulse shape and trigger delay. The low-leakage analog switch supports the hold interval, and the external capacitor determines whether the captured voltage remains accurate for the required observation period. Designers should include acquisition time in the overall trigger-to-sample budget and account for the time required to settle the output after switching from sample to hold. A shorter acquisition interval, faster slew behavior, or lower-leakage capacitor may be necessary for demanding pulse measurements.
推薦
Analog Feedback and Control Loops
The AD582SD can hold an analog error or command level when a feedback system requires a stable value between update events. The monolithic combination of an operational amplifier, low-leakage switch, and JFET integrating amplifier supports a compact analog-hold stage, while the 3 V/µs slew rate helps the circuit track changing inputs during acquisition. The 25 µs acquisition interval must remain compatible with the control-loop update period. Long hold times can expose capacitor leakage and parasitic leakage paths, so clean PCB assembly and guarding are important. Use the manufacturer application information to determine whether the device's aging, droop, and offset characteristics satisfy the loop's stability and accuracy requirements.
推薦
Legacy Data-Acquisition Equipment
The AD582SD is relevant to repairing or extending legacy data-acquisition equipment whose original design used the AD582 family. The 14-CDIP package and established 25 µs acquisition architecture allow an existing board-level architecture to be maintained when the exact suffix is confirmed. Its monolithic active circuitry reduces the complexity of substituting the sample-and-hold function into an older analog signal chain. However, the external holding capacitor and surrounding timing network remain design-critical: changing capacitor value or dielectric can alter acquisition, droop, offset, and noise behavior. Compare the replacement schematic, pin functions, supply requirements, and qualification markings with the original component before energizing the assembly.
推薦
推薦產品摘要
工程參考資料,適用於 AD582SD — 比較、設計指引及合規資訊。
選型指南
與替代品比較
| 參數 | 本產品 | AD582KD | AD582KH |
|---|---|---|---|
| Package | 14-CDIP (0.300 in, 7.62 mm) | 14-CDIP footprint; exact ceramic construction requires suffix-level verification | 14-CDIP footprint; exact ceramic construction requires suffix-level verification |
| Brand | Analog Devices | Analog Devices | Analog Devices |
| Product Type | Sample-and-hold amplifier | Sample-and-hold amplifier | Sample-and-hold amplifier |
| Number of Channels | 1 channel | 1 channel | 1 channel |
| Acquisition Time | 25 µs | 25 µs | 25 µs |
| Slew Rate | 3 V/µs | 3 V/µs | 3 V/µs |
| Internal Architecture | Operational amplifier, low-leakage analog switch, and JFET integrating amplifier | AD582-family sample-and-hold architecture | AD582-family sample-and-hold architecture |
| Ground Arrangement | Separate analog and digital grounds | Separate analog and digital grounds | Separate analog and digital grounds |
| External Holding Capacitor | Required | Required | Required |
主要差異化特點
- Integrated complete sample-and-hold signal path (對比AD582KD)
- Identical verified acquisition and slew timing (對比AD582KH)
- Separate analog and digital grounding (對比AD582KD)
- Established 14-CDIP legacy integration (對比AD582KH)
設計說明
Do not assume that the 25 µs acquisition specification is independent of the external holding capacitor. The capacitor value, dielectric, leakage, switch resistance, source impedance, and PCB leakage all influence settling and hold accuracy. Reproduce the manufacturer test circuit first, then verify temperature and supply extremes with the intended capacitor and board construction. A substitute capacitor with the same capacitance can still change acquisition time and droop.
Place the external holding capacitor and the AD582SD as close together as practical, and keep the connection between them short and shielded from nearby switching nodes. Route sensitive analog inputs away from digital return currents and clock or pulse edges. Separate analog and digital ground connections according to the manufacturer application circuit; joining them at the wrong point can allow ground and switching transients to appear directly on the held signal.
Include switch transition, acquisition settling, and hold-mode settling in the system timing budget rather than treating acquisition time as the complete sample-to-output delay. The specified 3 V/µs slew rate helps determine how quickly the amplifier can move through a required input change, but the output also depends on the held voltage and external capacitance. Test acquisition accuracy with the intended source impedance and downstream load, and measure droop over the longest required hold interval.
For maintenance and redesign work, compare the complete ordering suffix, ceramic-package construction, temperature range, qualification markings, and pin functions before replacing AD582SD with AD582KD or AD582KH. Matching the 14-pin outline and 25 µs acquisition specification is necessary but does not by itself prove regulatory or environmental equivalence. Review the manufacturer documents and inspect the original assembly markings before energizing the replacement.
合規資訊
Analog Devices states that versions of the AD582 family are available compliant with MIL-STD-883, but the exact AD582SD qualification status must be confirmed from the ordering guide and current military-products documentation. RoHS, REACH, lead-free, halogen-free, and conflict-minerals status are not stated for this exact suffix in the product materials reviewed.